PR rtl-optimization/82913
[official-gcc.git] / gcc / ada / gnatlink.adb
blob5e290eb639f77274871b3c22cb818af914ace4ac
1 ------------------------------------------------------------------------------
2 -- --
3 -- GNAT COMPILER COMPONENTS --
4 -- --
5 -- G N A T L I N K --
6 -- --
7 -- B o d y --
8 -- --
9 -- Copyright (C) 1996-2017, Free Software Foundation, Inc. --
10 -- --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License --
17 -- for more details. You should have received a copy of the GNU General --
18 -- Public License distributed with GNAT; see file COPYING3. If not, go to --
19 -- http://www.gnu.org/licenses for a complete copy of the license. --
20 -- --
21 -- GNAT was originally developed by the GNAT team at New York University. --
22 -- Extensive contributions were provided by Ada Core Technologies Inc. --
23 -- --
24 ------------------------------------------------------------------------------
26 -- Gnatlink usage: please consult the gnat documentation
28 with ALI; use ALI;
29 with Csets;
30 with Gnatvsn; use Gnatvsn;
31 with Indepsw; use Indepsw;
32 with Namet; use Namet;
33 with Opt;
34 with Osint; use Osint;
35 with Output; use Output;
36 with Snames;
37 with Switch; use Switch;
38 with System; use System;
39 with Table;
40 with Targparm;
41 with Types;
43 with Ada.Command_Line; use Ada.Command_Line;
44 with Ada.Exceptions; use Ada.Exceptions;
46 with System.OS_Lib; use System.OS_Lib;
47 with System.CRTL;
49 with Interfaces.C_Streams; use Interfaces.C_Streams;
50 with Interfaces.C.Strings; use Interfaces.C.Strings;
52 procedure Gnatlink is
53 pragma Ident (Gnatvsn.Gnat_Static_Version_String);
55 Shared_Libgcc_String : constant String := "-shared-libgcc";
56 Shared_Libgcc : constant String_Access :=
57 new String'(Shared_Libgcc_String);
58 -- Used to invoke gcc when the binder is invoked with -shared
60 Static_Libgcc_String : constant String := "-static-libgcc";
61 Static_Libgcc : constant String_Access :=
62 new String'(Static_Libgcc_String);
63 -- Used to invoke gcc when shared libs are not used
65 package Gcc_Linker_Options is new Table.Table (
66 Table_Component_Type => String_Access,
67 Table_Index_Type => Integer,
68 Table_Low_Bound => 1,
69 Table_Initial => 20,
70 Table_Increment => 100,
71 Table_Name => "Gnatlink.Gcc_Linker_Options");
72 -- Comments needed ???
74 package Libpath is new Table.Table (
75 Table_Component_Type => Character,
76 Table_Index_Type => Integer,
77 Table_Low_Bound => 1,
78 Table_Initial => 4096,
79 Table_Increment => 100,
80 Table_Name => "Gnatlink.Libpath");
81 -- Comments needed ???
83 package Linker_Options is new Table.Table (
84 Table_Component_Type => String_Access,
85 Table_Index_Type => Integer,
86 Table_Low_Bound => 1,
87 Table_Initial => 20,
88 Table_Increment => 100,
89 Table_Name => "Gnatlink.Linker_Options");
90 -- Comments needed ???
92 package Linker_Objects is new Table.Table (
93 Table_Component_Type => String_Access,
94 Table_Index_Type => Integer,
95 Table_Low_Bound => 1,
96 Table_Initial => 20,
97 Table_Increment => 100,
98 Table_Name => "Gnatlink.Linker_Objects");
99 -- This table collects the objects file to be passed to the linker. In the
100 -- case where the linker command line is too long then programs objects
101 -- are put on the Response_File_Objects table. Note that the binder object
102 -- file and the user's objects remain in this table. This is very
103 -- important because on the GNU linker command line the -L switch is not
104 -- used to look for objects files but -L switch is used to look for
105 -- objects listed in the response file. This is not a problem with the
106 -- applications objects as they are specified with a full name.
108 package Response_File_Objects is new Table.Table (
109 Table_Component_Type => String_Access,
110 Table_Index_Type => Integer,
111 Table_Low_Bound => 1,
112 Table_Initial => 20,
113 Table_Increment => 100,
114 Table_Name => "Gnatlink.Response_File_Objects");
115 -- This table collects the objects file that are to be put in the response
116 -- file. Only application objects are collected there (see details in
117 -- Linker_Objects table comments)
119 package Binder_Options_From_ALI is new Table.Table (
120 Table_Component_Type => String_Access,
121 Table_Index_Type => Integer,
122 Table_Low_Bound => 1, -- equals low bound of Argument_List for Spawn
123 Table_Initial => 20,
124 Table_Increment => 100,
125 Table_Name => "Gnatlink.Binder_Options_From_ALI");
126 -- This table collects the switches from the ALI file of the main
127 -- subprogram.
129 package Binder_Options is new Table.Table (
130 Table_Component_Type => String_Access,
131 Table_Index_Type => Integer,
132 Table_Low_Bound => 1, -- equals low bound of Argument_List for Spawn
133 Table_Initial => 20,
134 Table_Increment => 100,
135 Table_Name => "Gnatlink.Binder_Options");
136 -- This table collects the arguments to be passed to compile the binder
137 -- generated file.
139 Gcc : String_Access := Program_Name ("gcc", "gnatlink");
141 Read_Mode : constant String := "r" & ASCII.NUL;
143 Begin_Info : constant String := "-- BEGIN Object file/option list";
144 End_Info : constant String := "-- END Object file/option list ";
146 Gcc_Path : String_Access;
147 Linker_Path : String_Access;
148 Output_File_Name : String_Access;
149 Ali_File_Name : String_Access;
150 Binder_Spec_Src_File : String_Access;
151 Binder_Body_Src_File : String_Access;
152 Binder_Ali_File : String_Access;
153 Binder_Obj_File : String_Access;
155 Base_Command_Name : String_Access;
157 Target_Debuggable_Suffix : String_Access;
159 Tname : Temp_File_Name;
160 Tname_FD : File_Descriptor := Invalid_FD;
161 -- Temporary file used by linker to pass list of object files on
162 -- certain systems with limitations on size of arguments.
164 Debug_Flag_Present : Boolean := False;
165 Verbose_Mode : Boolean := False;
166 Very_Verbose_Mode : Boolean := False;
168 Standard_Gcc : Boolean := True;
170 Compile_Bind_File : Boolean := True;
171 -- Set to False if bind file is not to be compiled
173 Create_Map_File : Boolean := False;
174 -- Set to True by switch -M. The map file name is derived from
175 -- the ALI file name (mainprog.ali => mainprog.map).
177 Object_List_File_Supported : Boolean;
178 for Object_List_File_Supported'Size use Character'Size;
179 pragma Import
180 (C, Object_List_File_Supported, "__gnat_objlist_file_supported");
181 -- Predicate indicating whether the linker has an option whereby the
182 -- names of object files can be passed to the linker in a file.
184 Object_File_Option_Ptr : Interfaces.C.Strings.chars_ptr;
185 pragma Import (C, Object_File_Option_Ptr, "__gnat_object_file_option");
186 -- Pointer to a string representing the linker option which specifies
187 -- the response file.
189 Object_File_Option : constant String := Value (Object_File_Option_Ptr);
190 -- The linker option which specifies the response file as a string
192 Using_GNU_response_file : constant Boolean :=
193 Object_File_Option'Length > 0
194 and then Object_File_Option (Object_File_Option'Last) = '@';
195 -- Whether a GNU response file is used
197 Object_List_File_Required : Boolean := False;
198 -- Set to True to force generation of a response file
200 Shared_Libgcc_Default : Character;
201 for Shared_Libgcc_Default'Size use Character'Size;
202 pragma Import
203 (C, Shared_Libgcc_Default, "__gnat_shared_libgcc_default");
204 -- Indicates wether libgcc should be statically linked (use 'T') or
205 -- dynamically linked (use 'H') by default.
207 function Base_Name (File_Name : String) return String;
208 -- Return just the file name part without the extension (if present)
210 procedure Check_Existing_Executable (File_Name : String);
211 -- Delete any existing executable to avoid accidentally updating the target
212 -- of a symbolic link, but produce a Fatail_Error if File_Name matches any
213 -- of the source file names. This avoids overwriting of extensionless
214 -- source files by accident on systems where executables do not have
215 -- extensions.
217 procedure Delete (Name : String);
218 -- Wrapper to unlink as status is ignored by this application
220 procedure Error_Msg (Message : String);
221 -- Output the error or warning Message
223 procedure Exit_With_Error (Error : String);
224 -- Output Error and exit program with a fatal condition
226 procedure Process_Args;
227 -- Go through all the arguments and build option tables
229 procedure Process_Binder_File (Name : String);
230 -- Reads the binder file and extracts linker arguments
232 procedure Usage;
233 -- Display usage
235 procedure Write_Header;
236 -- Show user the program name, version and copyright
238 procedure Write_Usage;
239 -- Show user the program options
241 ---------------
242 -- Base_Name --
243 ---------------
245 function Base_Name (File_Name : String) return String is
246 Findex1 : Natural;
247 Findex2 : Natural;
249 begin
250 Findex1 := File_Name'First;
252 -- The file might be specified by a full path name. However,
253 -- we want the path to be stripped away.
255 for J in reverse File_Name'Range loop
256 if Is_Directory_Separator (File_Name (J)) then
257 Findex1 := J + 1;
258 exit;
259 end if;
260 end loop;
262 Findex2 := File_Name'Last;
263 while Findex2 > Findex1 and then File_Name (Findex2) /= '.' loop
264 Findex2 := Findex2 - 1;
265 end loop;
267 if Findex2 = Findex1 then
268 Findex2 := File_Name'Last + 1;
269 end if;
271 return File_Name (Findex1 .. Findex2 - 1);
272 end Base_Name;
274 -------------------------------
275 -- Check_Existing_Executable --
276 -------------------------------
278 procedure Check_Existing_Executable (File_Name : String) is
279 Ename : String := File_Name;
280 Efile : File_Name_Type;
281 Sfile : File_Name_Type;
283 begin
284 Canonical_Case_File_Name (Ename);
285 Name_Len := 0;
286 Add_Str_To_Name_Buffer (Ename);
287 Efile := Name_Find;
289 for J in Units.Table'First .. Units.Last loop
290 Sfile := Units.Table (J).Sfile;
291 if Sfile = Efile then
292 Exit_With_Error
293 ("executable name """ & File_Name & """ matches "
294 & "source file name """ & Get_Name_String (Sfile) & """");
295 end if;
296 end loop;
298 Delete (File_Name);
299 end Check_Existing_Executable;
301 ------------
302 -- Delete --
303 ------------
305 procedure Delete (Name : String) is
306 Status : int;
307 pragma Unreferenced (Status);
308 begin
309 Status := unlink (Name'Address);
310 -- Is it really right to ignore an error here ???
311 end Delete;
313 ---------------
314 -- Error_Msg --
315 ---------------
317 procedure Error_Msg (Message : String) is
318 begin
319 Write_Str (Base_Command_Name.all);
320 Write_Str (": ");
321 Write_Str (Message);
322 Write_Eol;
323 end Error_Msg;
325 ---------------------
326 -- Exit_With_Error --
327 ---------------------
329 procedure Exit_With_Error (Error : String) is
330 begin
331 Error_Msg (Error);
332 Exit_Program (E_Fatal);
333 end Exit_With_Error;
335 ------------------
336 -- Process_Args --
337 ------------------
339 procedure Process_Args is
340 Next_Arg : Integer;
342 Skip_Next : Boolean := False;
343 -- Set to true if the next argument is to be added into the list of
344 -- linker's argument without parsing it.
346 procedure Check_Version_And_Help is new Check_Version_And_Help_G (Usage);
348 -- Start of processing for Process_Args
350 begin
351 -- First, check for --version and --help
353 Check_Version_And_Help ("GNATLINK", "1996");
355 -- Loop through arguments of gnatlink command
357 Next_Arg := 1;
358 loop
359 exit when Next_Arg > Argument_Count;
361 Process_One_Arg : declare
362 Arg : constant String := Argument (Next_Arg);
364 begin
365 -- Case of argument which is a switch
367 -- We definitely need section by section comments here ???
369 if Skip_Next then
371 -- This argument must not be parsed, just add it to the
372 -- list of linker's options.
374 Skip_Next := False;
376 Linker_Options.Increment_Last;
377 Linker_Options.Table (Linker_Options.Last) :=
378 new String'(Arg);
380 elsif Arg'Length /= 0 and then Arg (1) = '-' then
381 if Arg'Length > 4 and then Arg (2 .. 5) = "gnat" then
382 Exit_With_Error
383 ("invalid switch: """ & Arg & """ (gnat not needed here)");
384 end if;
386 if Arg = "-Xlinker" then
388 -- Next argument should be sent directly to the linker.
389 -- We do not want to parse it here.
391 Skip_Next := True;
393 Linker_Options.Increment_Last;
394 Linker_Options.Table (Linker_Options.Last) :=
395 new String'(Arg);
397 elsif Arg (2) = 'g'
398 and then (Arg'Length < 5 or else Arg (2 .. 5) /= "gnat")
399 then
400 Debug_Flag_Present := True;
402 Linker_Options.Increment_Last;
403 Linker_Options.Table (Linker_Options.Last) :=
404 new String'(Arg);
406 Binder_Options.Increment_Last;
407 Binder_Options.Table (Binder_Options.Last) :=
408 Linker_Options.Table (Linker_Options.Last);
410 elsif Arg'Length >= 3 and then Arg (2) = 'M' then
411 declare
412 Switches : String_List_Access;
414 begin
415 Convert (Map_File, Arg (3 .. Arg'Last), Switches);
417 if Switches /= null then
418 for J in Switches'Range loop
419 Linker_Options.Increment_Last;
420 Linker_Options.Table (Linker_Options.Last) :=
421 Switches (J);
422 end loop;
423 end if;
424 end;
426 elsif Arg'Length = 2 then
427 case Arg (2) is
428 when 'b' =>
429 Linker_Options.Increment_Last;
430 Linker_Options.Table (Linker_Options.Last) :=
431 new String'(Arg);
433 Binder_Options.Increment_Last;
434 Binder_Options.Table (Binder_Options.Last) :=
435 Linker_Options.Table (Linker_Options.Last);
437 Next_Arg := Next_Arg + 1;
439 if Next_Arg > Argument_Count then
440 Exit_With_Error ("Missing argument for -b");
441 end if;
443 Get_Machine_Name : declare
444 Name_Arg : constant String_Access :=
445 new String'(Argument (Next_Arg));
447 begin
448 Linker_Options.Increment_Last;
449 Linker_Options.Table (Linker_Options.Last) :=
450 Name_Arg;
452 Binder_Options.Increment_Last;
453 Binder_Options.Table (Binder_Options.Last) :=
454 Name_Arg;
456 end Get_Machine_Name;
458 when 'f' =>
459 if Object_List_File_Supported then
460 Object_List_File_Required := True;
461 else
462 Exit_With_Error
463 ("Object list file not supported on this target");
464 end if;
466 when 'M' =>
467 Create_Map_File := True;
469 when 'n' =>
470 Compile_Bind_File := False;
472 when 'o' =>
473 Next_Arg := Next_Arg + 1;
475 if Next_Arg > Argument_Count then
476 Exit_With_Error ("Missing argument for -o");
477 end if;
479 Output_File_Name :=
480 new String'(Executable_Name
481 (Argument (Next_Arg),
482 Only_If_No_Suffix => True));
484 when 'P' =>
485 Opt.CodePeer_Mode := True;
487 when 'R' =>
488 Opt.Run_Path_Option := False;
490 when 'v' =>
492 -- Support "double" verbose mode. Second -v
493 -- gets sent to the linker and binder phases.
495 if Verbose_Mode then
496 Very_Verbose_Mode := True;
498 Linker_Options.Increment_Last;
499 Linker_Options.Table (Linker_Options.Last) :=
500 new String'(Arg);
502 Binder_Options.Increment_Last;
503 Binder_Options.Table (Binder_Options.Last) :=
504 Linker_Options.Table (Linker_Options.Last);
506 else
507 Verbose_Mode := True;
509 end if;
511 when others =>
512 Linker_Options.Increment_Last;
513 Linker_Options.Table (Linker_Options.Last) :=
514 new String'(Arg);
516 end case;
518 elsif Arg (2) = 'B' then
519 Linker_Options.Increment_Last;
520 Linker_Options.Table (Linker_Options.Last) :=
521 new String'(Arg);
523 Binder_Options.Increment_Last;
524 Binder_Options.Table (Binder_Options.Last) :=
525 Linker_Options.Table (Linker_Options.Last);
527 elsif Arg'Length >= 7 and then Arg (1 .. 7) = "--LINK=" then
528 if Arg'Length = 7 then
529 Exit_With_Error ("Missing argument for --LINK=");
530 end if;
532 Linker_Path :=
533 System.OS_Lib.Locate_Exec_On_Path (Arg (8 .. Arg'Last));
535 if Linker_Path = null then
536 Exit_With_Error
537 ("Could not locate linker: " & Arg (8 .. Arg'Last));
538 end if;
540 elsif Arg'Length > 6 and then Arg (1 .. 6) = "--GCC=" then
541 declare
542 Program_Args : constant Argument_List_Access :=
543 Argument_String_To_List
544 (Arg (7 .. Arg'Last));
546 begin
547 if Program_Args.all (1).all /= Gcc.all then
548 Gcc := new String'(Program_Args.all (1).all);
549 Standard_Gcc := False;
550 end if;
552 -- Set appropriate flags for switches passed
554 for J in 2 .. Program_Args.all'Last loop
555 declare
556 Arg : constant String := Program_Args.all (J).all;
557 AF : constant Integer := Arg'First;
559 begin
560 if Arg'Length /= 0 and then Arg (AF) = '-' then
561 if Arg (AF + 1) = 'g'
562 and then (Arg'Length = 2
563 or else Arg (AF + 2) in '0' .. '3'
564 or else Arg (AF + 2 .. Arg'Last) = "coff")
565 then
566 Debug_Flag_Present := True;
567 end if;
568 end if;
570 -- Add directory to source search dirs so that
571 -- Get_Target_Parameters can find system.ads
573 if Arg (AF .. AF + 1) = "-I"
574 and then Arg'Length > 2
575 then
576 Add_Src_Search_Dir (Arg (AF + 2 .. Arg'Last));
577 end if;
579 -- Pass to gcc for compiling binder generated file
580 -- No use passing libraries, it will just generate
581 -- a warning
583 if not (Arg (AF .. AF + 1) = "-l"
584 or else Arg (AF .. AF + 1) = "-L")
585 then
586 Binder_Options.Increment_Last;
587 Binder_Options.Table (Binder_Options.Last) :=
588 new String'(Arg);
589 end if;
591 -- Pass to gcc for linking program
593 Gcc_Linker_Options.Increment_Last;
594 Gcc_Linker_Options.Table
595 (Gcc_Linker_Options.Last) := new String'(Arg);
596 end;
597 end loop;
598 end;
600 -- Send all multi-character switches not recognized as
601 -- a special case by gnatlink to the linker/loader stage.
603 else
604 Linker_Options.Increment_Last;
605 Linker_Options.Table (Linker_Options.Last) :=
606 new String'(Arg);
607 end if;
609 -- Here if argument is a file name rather than a switch
611 else
612 -- If explicit ali file, capture it
614 if Arg'Length > 4
615 and then Arg (Arg'Last - 3 .. Arg'Last) = ".ali"
616 then
617 if Ali_File_Name = null then
618 Ali_File_Name := new String'(Arg);
619 else
620 Exit_With_Error ("cannot handle more than one ALI file");
621 end if;
623 -- If target object file, record object file
625 elsif Arg'Length > Get_Target_Object_Suffix.all'Length
626 and then Arg
627 (Arg'Last -
628 Get_Target_Object_Suffix.all'Length + 1 .. Arg'Last)
629 = Get_Target_Object_Suffix.all
630 then
631 Linker_Objects.Increment_Last;
632 Linker_Objects.Table (Linker_Objects.Last) :=
633 new String'(Arg);
635 -- If host object file, record object file
637 elsif Arg'Length > Get_Object_Suffix.all'Length
638 and then Arg
639 (Arg'Last - Get_Object_Suffix.all'Length + 1 .. Arg'Last)
640 = Get_Object_Suffix.all
641 then
642 Linker_Objects.Increment_Last;
643 Linker_Objects.Table (Linker_Objects.Last) :=
644 new String'(Arg);
646 -- If corresponding ali file exists, capture it
648 elsif Ali_File_Name = null
649 and then Is_Regular_File (Arg & ".ali")
650 then
651 Ali_File_Name := new String'(Arg & ".ali");
653 -- Otherwise assume this is a linker options entry, but
654 -- see below for interesting adjustment to this assumption.
656 else
657 Linker_Options.Increment_Last;
658 Linker_Options.Table (Linker_Options.Last) :=
659 new String'(Arg);
660 end if;
661 end if;
662 end Process_One_Arg;
664 Next_Arg := Next_Arg + 1;
665 end loop;
667 -- Compile the bind file with warnings suppressed, because
668 -- otherwise the with of the main program may cause junk warnings.
670 Binder_Options.Increment_Last;
671 Binder_Options.Table (Binder_Options.Last) := new String'("-gnatws");
673 -- If we did not get an ali file at all, and we had at least one
674 -- linker option, then assume that was the intended ali file after
675 -- all, so that we get a nicer message later on.
677 if Ali_File_Name = null
678 and then Linker_Options.Last >= Linker_Options.First
679 then
680 Ali_File_Name :=
681 new String'(Linker_Options.Table (Linker_Options.First).all
682 & ".ali");
683 end if;
684 end Process_Args;
686 -------------------------
687 -- Process_Binder_File --
688 -------------------------
690 procedure Process_Binder_File (Name : String) is
691 Fd : FILEs;
692 -- Binder file's descriptor
694 Link_Bytes : Integer := 0;
695 -- Projected number of bytes for the linker command line
697 Link_Max : Integer;
698 pragma Import (C, Link_Max, "__gnat_link_max");
699 -- Maximum number of bytes on the command line supported by the OS
700 -- linker. Passed this limit the response file mechanism must be used
701 -- if supported.
703 Next_Line : String (1 .. 1000);
704 -- Current line value
706 Nlast : Integer;
707 Nfirst : Integer;
708 -- Current line slice (the slice does not contain line terminator)
710 Last : Integer;
711 -- Current line last character for shared libraries (without version)
713 Objs_Begin : Integer := 0;
714 -- First object file index in Linker_Objects table
716 Objs_End : Integer := 0;
717 -- Last object file index in Linker_Objects table
719 Status : int;
720 pragma Warnings (Off, Status);
721 -- Used for various Interfaces.C_Streams calls
723 Closing_Status : Boolean;
724 pragma Warnings (Off, Closing_Status);
725 -- For call to Close
727 GNAT_Static : Boolean := False;
728 -- Save state of -static option
730 GNAT_Shared : Boolean := False;
731 -- Save state of -shared option
733 Xlinker_Was_Previous : Boolean := False;
734 -- Indicate that "-Xlinker" was the option preceding the current option.
735 -- If True, then the current option is never suppressed.
737 -- Rollback data
739 -- These data items are used to store current binder file context. The
740 -- context is composed of the file descriptor position and the current
741 -- line together with the slice indexes (first and last position) for
742 -- this line. The rollback data are used by the Store_File_Context and
743 -- Rollback_File_Context routines below. The file context mechanism
744 -- interact only with the Get_Next_Line call. For example:
746 -- Store_File_Context;
747 -- Get_Next_Line;
748 -- Rollback_File_Context;
749 -- Get_Next_Line;
751 -- Both Get_Next_Line calls above will read the exact same data from
752 -- the file. In other words, Next_Line, Nfirst and Nlast variables
753 -- will be set with the exact same values.
755 RB_File_Pos : long; -- File position
756 RB_Next_Line : String (1 .. 1000); -- Current line content
757 RB_Nlast : Integer; -- Slice last index
758 RB_Nfirst : Integer; -- Slice first index
760 Run_Path_Option_Ptr : Interfaces.C.Strings.chars_ptr;
761 pragma Import (C, Run_Path_Option_Ptr, "__gnat_run_path_option");
762 -- Pointer to string representing the native linker option which
763 -- specifies the path where the dynamic loader should find shared
764 -- libraries. Equal to null string if this system doesn't support it.
766 Libgcc_Subdir_Ptr : Interfaces.C.Strings.chars_ptr;
767 pragma Import (C, Libgcc_Subdir_Ptr, "__gnat_default_libgcc_subdir");
768 -- Pointer to string indicating the installation subdirectory where
769 -- a default shared libgcc might be found.
771 Object_Library_Ext_Ptr : Interfaces.C.Strings.chars_ptr;
772 pragma Import
773 (C, Object_Library_Ext_Ptr, "__gnat_object_library_extension");
774 -- Pointer to string specifying the default extension for
775 -- object libraries, e.g. Unix uses ".a".
777 Separate_Run_Path_Options : Boolean;
778 for Separate_Run_Path_Options'Size use Character'Size;
779 pragma Import
780 (C, Separate_Run_Path_Options, "__gnat_separate_run_path_options");
781 -- Whether separate rpath options should be emitted for each directory
783 procedure Get_Next_Line;
784 -- Read the next line from the binder file without the line
785 -- terminator.
787 function Index (S, Pattern : String) return Natural;
788 -- Return the last occurrence of Pattern in S, or 0 if none
790 procedure Store_File_Context;
791 -- Store current file context, Fd position and current line data.
792 -- The file context is stored into the rollback data above (RB_*).
793 -- Store_File_Context can be called at any time, only the last call
794 -- will be used (i.e. this routine overwrites the file context).
796 procedure Rollback_File_Context;
797 -- Restore file context from rollback data. This routine must be called
798 -- after Store_File_Context. The binder file context will be restored
799 -- with the data stored by the last Store_File_Context call.
801 procedure Write_RF (S : String);
802 -- Write a string to the response file and check if it was successful.
803 -- Fail the program if it was not successful (disk full).
805 -------------------
806 -- Get_Next_Line --
807 -------------------
809 procedure Get_Next_Line is
810 Fchars : chars;
812 begin
813 Fchars := fgets (Next_Line'Address, Next_Line'Length, Fd);
815 if Fchars = System.Null_Address then
816 Exit_With_Error ("Error reading binder output");
817 end if;
819 Nfirst := Next_Line'First;
820 Nlast := Nfirst;
821 while Nlast <= Next_Line'Last
822 and then Next_Line (Nlast) /= ASCII.LF
823 and then Next_Line (Nlast) /= ASCII.CR
824 loop
825 Nlast := Nlast + 1;
826 end loop;
828 Nlast := Nlast - 1;
829 end Get_Next_Line;
831 -----------
832 -- Index --
833 -----------
835 function Index (S, Pattern : String) return Natural is
836 Len : constant Natural := Pattern'Length;
838 begin
839 for J in reverse S'First .. S'Last - Len + 1 loop
840 if Pattern = S (J .. J + Len - 1) then
841 return J;
842 end if;
843 end loop;
845 return 0;
846 end Index;
848 ---------------------------
849 -- Rollback_File_Context --
850 ---------------------------
852 procedure Rollback_File_Context is
853 begin
854 Next_Line := RB_Next_Line;
855 Nfirst := RB_Nfirst;
856 Nlast := RB_Nlast;
857 Status := fseek (Fd, RB_File_Pos, Interfaces.C_Streams.SEEK_SET);
859 if Status = -1 then
860 Exit_With_Error ("Error setting file position");
861 end if;
862 end Rollback_File_Context;
864 ------------------------
865 -- Store_File_Context --
866 ------------------------
868 procedure Store_File_Context is
869 use type System.CRTL.long;
871 begin
872 RB_Next_Line := Next_Line;
873 RB_Nfirst := Nfirst;
874 RB_Nlast := Nlast;
875 RB_File_Pos := ftell (Fd);
877 if RB_File_Pos = -1 then
878 Exit_With_Error ("Error getting file position");
879 end if;
880 end Store_File_Context;
882 --------------
883 -- Write_RF --
884 --------------
886 procedure Write_RF (S : String) is
887 Success : Boolean := True;
888 Back_Slash : constant Character := '\';
890 begin
891 -- If a GNU response file is used, space and backslash need to be
892 -- escaped because they are interpreted as a string separator and
893 -- an escape character respectively by the underlying mechanism.
894 -- On the other hand, quote and double-quote are not escaped since
895 -- they are interpreted as string delimiters on both sides.
897 if Using_GNU_response_file then
898 for J in S'Range loop
899 if S (J) = ' ' or else S (J) = '\' then
900 if Write (Tname_FD, Back_Slash'Address, 1) /= 1 then
901 Success := False;
902 end if;
903 end if;
905 if Write (Tname_FD, S (J)'Address, 1) /= 1 then
906 Success := False;
907 end if;
908 end loop;
910 else
911 if Write (Tname_FD, S'Address, S'Length) /= S'Length then
912 Success := False;
913 end if;
914 end if;
916 if Write (Tname_FD, ASCII.LF'Address, 1) /= 1 then
917 Success := False;
918 end if;
920 if not Success then
921 Exit_With_Error ("Error generating response file: disk full");
922 end if;
923 end Write_RF;
925 -- Start of processing for Process_Binder_File
927 begin
928 Fd := fopen (Name'Address, Read_Mode'Address);
930 if Fd = NULL_Stream then
931 Exit_With_Error ("Failed to open binder output");
932 end if;
934 -- Skip up to the Begin Info line
936 loop
937 Get_Next_Line;
938 exit when Next_Line (Nfirst .. Nlast) = Begin_Info;
939 end loop;
941 loop
942 Get_Next_Line;
944 -- Go to end when end line is reached (this will happen in
945 -- High_Integrity_Mode where no -L switches are generated)
947 exit when Next_Line (Nfirst .. Nlast) = End_Info;
949 Next_Line (Nfirst .. Nlast - 8) := Next_Line (Nfirst + 8 .. Nlast);
950 Nlast := Nlast - 8;
952 -- Go to next section when switches are reached
954 exit when Next_Line (1) = '-';
956 -- Otherwise we have another object file to collect
958 Linker_Objects.Increment_Last;
960 -- Mark the positions of first and last object files in case they
961 -- need to be placed with a named file on systems having linker
962 -- line limitations.
964 if Objs_Begin = 0 then
965 Objs_Begin := Linker_Objects.Last;
966 end if;
968 Linker_Objects.Table (Linker_Objects.Last) :=
969 new String'(Next_Line (Nfirst .. Nlast));
971 -- Nlast - Nfirst + 1, for the size, plus one for the space between
972 -- each arguments.
974 Link_Bytes := Link_Bytes + Nlast - Nfirst + 2;
975 end loop;
977 Objs_End := Linker_Objects.Last;
979 -- Continue to compute the Link_Bytes, the linker options are part of
980 -- command line length.
982 Store_File_Context;
984 while Next_Line (Nfirst .. Nlast) /= End_Info loop
985 Link_Bytes := Link_Bytes + Nlast - Nfirst + 2;
986 Get_Next_Line;
987 end loop;
989 Rollback_File_Context;
991 -- On systems that have limitations on handling very long linker lines
992 -- we make use of the system linker option which takes a list of object
993 -- file names from a file instead of the command line itself. What we do
994 -- is to replace the list of object files by the special linker option
995 -- which then reads the object file list from a file instead. The option
996 -- to read from a file instead of the command line is only triggered if
997 -- a conservative threshold is passed.
999 if Object_List_File_Required
1000 or else (Object_List_File_Supported
1001 and then Link_Bytes > Link_Max)
1002 then
1003 -- Create a temporary file containing the Ada user object files
1004 -- needed by the link. This list is taken from the bind file and is
1005 -- output one object per line for maximal compatibility with linkers
1006 -- supporting this option.
1008 Create_Temp_File (Tname_FD, Tname);
1010 -- ??? File descriptor should be checked to not be Invalid_FD.
1011 -- ??? Status of Write and Close operations should be checked, and
1012 -- failure should occur if a status is wrong.
1014 for J in Objs_Begin .. Objs_End loop
1015 Write_RF (Linker_Objects.Table (J).all);
1017 Response_File_Objects.Increment_Last;
1018 Response_File_Objects.Table (Response_File_Objects.Last) :=
1019 Linker_Objects.Table (J);
1020 end loop;
1022 Close (Tname_FD, Closing_Status);
1024 -- Add the special objects list file option together with the name
1025 -- of the temporary file (removing the null character) to the objects
1026 -- file table.
1028 Linker_Objects.Table (Objs_Begin) :=
1029 new String'(Object_File_Option &
1030 Tname (Tname'First .. Tname'Last - 1));
1032 -- The slots containing these object file names are then removed
1033 -- from the objects table so they do not appear in the link. They are
1034 -- removed by moving up the linker options and non-Ada object files
1035 -- appearing after the Ada object list in the table.
1037 declare
1038 N : Integer;
1040 begin
1041 N := Objs_End - Objs_Begin + 1;
1043 for J in Objs_End + 1 .. Linker_Objects.Last loop
1044 Linker_Objects.Table (J - N + 1) := Linker_Objects.Table (J);
1045 end loop;
1047 Linker_Objects.Set_Last (Linker_Objects.Last - N + 1);
1048 end;
1049 end if;
1051 -- Process switches and options
1053 if Next_Line (Nfirst .. Nlast) /= End_Info then
1054 Xlinker_Was_Previous := False;
1056 loop
1057 if Xlinker_Was_Previous
1058 or else Next_Line (Nfirst .. Nlast) = "-Xlinker"
1059 then
1060 Linker_Options.Increment_Last;
1061 Linker_Options.Table (Linker_Options.Last) :=
1062 new String'(Next_Line (Nfirst .. Nlast));
1064 elsif Next_Line (Nfirst .. Nlast) = "-static" then
1065 GNAT_Static := True;
1067 elsif Next_Line (Nfirst .. Nlast) = "-shared" then
1068 GNAT_Shared := True;
1070 -- Add binder options only if not already set on the command line.
1071 -- This rule is a way to control the linker options order.
1073 else
1074 if Nlast > Nfirst + 2 and then
1075 Next_Line (Nfirst .. Nfirst + 1) = "-L"
1076 then
1077 -- Construct a library search path for use later to locate
1078 -- static gnatlib libraries.
1080 if Libpath.Last > 1 then
1081 Libpath.Increment_Last;
1082 Libpath.Table (Libpath.Last) := Path_Separator;
1083 end if;
1085 for I in Nfirst + 2 .. Nlast loop
1086 Libpath.Increment_Last;
1087 Libpath.Table (Libpath.Last) := Next_Line (I);
1088 end loop;
1090 Linker_Options.Increment_Last;
1092 Linker_Options.Table (Linker_Options.Last) :=
1093 new String'(Next_Line (Nfirst .. Nlast));
1095 elsif Next_Line (Nfirst .. Nlast) = "-lgnarl"
1096 or else Next_Line (Nfirst .. Nlast) = "-lgnat"
1097 or else
1098 Next_Line
1099 (1 .. Natural'Min (Nlast, 8 + Library_Version'Length)) =
1100 Shared_Lib ("gnarl")
1101 or else
1102 Next_Line
1103 (1 .. Natural'Min (Nlast, 7 + Library_Version'Length)) =
1104 Shared_Lib ("gnat")
1105 then
1106 -- If it is a shared library, remove the library version.
1107 -- We will be looking for the static version of the library
1108 -- as it is in the same directory as the shared version.
1110 if Next_Line (Nlast - Library_Version'Length + 1 .. Nlast) =
1111 Library_Version
1112 then
1113 -- Set Last to point to last character before the
1114 -- library version.
1116 Last := Nlast - Library_Version'Length - 1;
1117 else
1118 Last := Nlast;
1119 end if;
1121 -- Given a Gnat standard library, search the library path to
1122 -- find the library location.
1124 -- Shouldn't we abstract a proc here, we are getting awfully
1125 -- heavily nested ???
1127 declare
1128 File_Path : String_Access;
1130 Object_Lib_Extension : constant String :=
1131 Value (Object_Library_Ext_Ptr);
1133 File_Name : constant String := "lib" &
1134 Next_Line (Nfirst + 2 .. Last) & Object_Lib_Extension;
1136 Run_Path_Opt : constant String :=
1137 Value (Run_Path_Option_Ptr);
1139 GCC_Index : Natural;
1140 Run_Path_Opt_Index : Natural := 0;
1142 begin
1143 File_Path :=
1144 Locate_Regular_File (File_Name,
1145 String (Libpath.Table (1 .. Libpath.Last)));
1147 if File_Path /= null then
1148 if GNAT_Static then
1150 -- If static gnatlib found, explicitly specify to
1151 -- overcome possible linker default usage of shared
1152 -- version.
1154 Linker_Options.Increment_Last;
1156 Linker_Options.Table (Linker_Options.Last) :=
1157 new String'(File_Path.all);
1159 elsif GNAT_Shared then
1160 if Opt.Run_Path_Option then
1162 -- If shared gnatlib desired, add appropriate
1163 -- system specific switch so that it can be
1164 -- located at runtime.
1166 if Run_Path_Opt'Length /= 0 then
1168 -- Output the system specific linker command
1169 -- that allows the image activator to find
1170 -- the shared library at runtime. Also add
1171 -- path to find libgcc_s.so, if relevant.
1173 declare
1174 Path : String (1 .. File_Path'Length + 15);
1176 Path_Last : constant Natural :=
1177 File_Path'Length;
1179 begin
1180 Path (1 .. File_Path'Length) :=
1181 File_Path.all;
1183 -- To find the location of the shared version
1184 -- of libgcc, we look for "gcc-lib" in the
1185 -- path of the library. However, this
1186 -- subdirectory is no longer present in
1187 -- recent versions of GCC. So, we look for
1188 -- the last subdirectory "lib" in the path.
1190 GCC_Index :=
1191 Index (Path (1 .. Path_Last), "gcc-lib");
1193 if GCC_Index /= 0 then
1195 -- The shared version of libgcc is
1196 -- located in the parent directory.
1198 GCC_Index := GCC_Index - 1;
1200 else
1201 GCC_Index :=
1202 Index
1203 (Path (1 .. Path_Last),
1204 "/lib/");
1206 if GCC_Index = 0 then
1207 GCC_Index :=
1208 Index (Path (1 .. Path_Last),
1209 Directory_Separator & "lib"
1210 & Directory_Separator);
1211 end if;
1213 -- If we have found a "lib" subdir in
1214 -- the path to libgnat, the possible
1215 -- shared libgcc of interest by default
1216 -- is in libgcc_subdir at the same
1217 -- level.
1219 if GCC_Index /= 0 then
1220 declare
1221 Subdir : constant String :=
1222 Value (Libgcc_Subdir_Ptr);
1223 begin
1224 Path
1225 (GCC_Index + 1 ..
1226 GCC_Index + Subdir'Length) :=
1227 Subdir;
1228 GCC_Index :=
1229 GCC_Index + Subdir'Length;
1230 end;
1231 end if;
1232 end if;
1234 -- Look for an eventual run_path_option in
1235 -- the linker switches.
1237 if Separate_Run_Path_Options then
1238 Linker_Options.Increment_Last;
1239 Linker_Options.Table
1240 (Linker_Options.Last) :=
1241 new String'
1242 (Run_Path_Opt
1243 & File_Path
1244 (1 .. File_Path'Length
1245 - File_Name'Length));
1247 if GCC_Index /= 0 then
1248 Linker_Options.Increment_Last;
1249 Linker_Options.Table
1250 (Linker_Options.Last) :=
1251 new String'
1252 (Run_Path_Opt
1253 & Path (1 .. GCC_Index));
1254 end if;
1256 else
1257 for J in reverse
1258 1 .. Linker_Options.Last
1259 loop
1260 if Linker_Options.Table (J) /= null
1261 and then
1262 Linker_Options.Table (J)'Length
1263 > Run_Path_Opt'Length
1264 and then
1265 Linker_Options.Table (J)
1266 (1 .. Run_Path_Opt'Length) =
1267 Run_Path_Opt
1268 then
1269 -- We have found an already
1270 -- specified run_path_option:
1271 -- we will add to this
1272 -- switch, because only one
1273 -- run_path_option should be
1274 -- specified.
1276 Run_Path_Opt_Index := J;
1277 exit;
1278 end if;
1279 end loop;
1281 -- If there is no run_path_option, we
1282 -- need to add one.
1284 if Run_Path_Opt_Index = 0 then
1285 Linker_Options.Increment_Last;
1286 end if;
1288 if GCC_Index = 0 then
1289 if Run_Path_Opt_Index = 0 then
1290 Linker_Options.Table
1291 (Linker_Options.Last) :=
1292 new String'
1293 (Run_Path_Opt
1294 & File_Path
1295 (1 .. File_Path'Length
1296 - File_Name'Length));
1298 else
1299 Linker_Options.Table
1300 (Run_Path_Opt_Index) :=
1301 new String'
1302 (Linker_Options.Table
1303 (Run_Path_Opt_Index).all
1304 & Path_Separator
1305 & File_Path
1306 (1 .. File_Path'Length
1307 - File_Name'Length));
1308 end if;
1310 else
1311 if Run_Path_Opt_Index = 0 then
1312 Linker_Options.Table
1313 (Linker_Options.Last) :=
1314 new String'
1315 (Run_Path_Opt
1316 & File_Path
1317 (1 .. File_Path'Length
1318 - File_Name'Length)
1319 & Path_Separator
1320 & Path (1 .. GCC_Index));
1322 else
1323 Linker_Options.Table
1324 (Run_Path_Opt_Index) :=
1325 new String'
1326 (Linker_Options.Table
1327 (Run_Path_Opt_Index).all
1328 & Path_Separator
1329 & File_Path
1330 (1 .. File_Path'Length
1331 - File_Name'Length)
1332 & Path_Separator
1333 & Path (1 .. GCC_Index));
1334 end if;
1335 end if;
1336 end if;
1337 end;
1338 end if;
1339 end if;
1341 -- Then we add the appropriate -l switch
1343 Linker_Options.Increment_Last;
1344 Linker_Options.Table (Linker_Options.Last) :=
1345 new String'(Next_Line (Nfirst .. Nlast));
1346 end if;
1348 else
1349 -- If gnatlib library not found, then add it anyway in
1350 -- case some other mechanism may find it.
1352 Linker_Options.Increment_Last;
1353 Linker_Options.Table (Linker_Options.Last) :=
1354 new String'(Next_Line (Nfirst .. Nlast));
1355 end if;
1356 end;
1357 else
1358 Linker_Options.Increment_Last;
1359 Linker_Options.Table (Linker_Options.Last) :=
1360 new String'(Next_Line (Nfirst .. Nlast));
1361 end if;
1362 end if;
1364 Xlinker_Was_Previous := Next_Line (Nfirst .. Nlast) = "-Xlinker";
1366 Get_Next_Line;
1367 exit when Next_Line (Nfirst .. Nlast) = End_Info;
1369 Next_Line (Nfirst .. Nlast - 8) := Next_Line (Nfirst + 8 .. Nlast);
1370 Nlast := Nlast - 8;
1371 end loop;
1372 end if;
1374 -- If -shared was specified, invoke gcc with -shared-libgcc
1376 if GNAT_Shared then
1377 Linker_Options.Increment_Last;
1378 Linker_Options.Table (Linker_Options.Last) := Shared_Libgcc;
1379 end if;
1381 Status := fclose (Fd);
1382 end Process_Binder_File;
1384 -----------
1385 -- Usage --
1386 -----------
1388 procedure Usage is
1389 begin
1390 Write_Str ("Usage: ");
1391 Write_Str (Base_Command_Name.all);
1392 Write_Str (" switches mainprog.ali [non-Ada-objects] [linker-options]");
1393 Write_Eol;
1394 Write_Eol;
1395 Write_Line (" mainprog.ali the ALI file of the main program");
1396 Write_Eol;
1397 Write_Eol;
1398 Display_Usage_Version_And_Help;
1399 Write_Line (" -f Force object file list to be generated");
1400 Write_Line (" -g Compile binder source file with debug information");
1401 Write_Line (" -n Do not compile the binder source file");
1402 Write_Line (" -P Process files for use by CodePeer");
1403 Write_Line (" -R Do not use a run_path_option");
1404 Write_Line (" -v Verbose mode");
1405 Write_Line (" -v -v Very verbose mode");
1406 Write_Eol;
1407 Write_Line (" -o nam Use 'nam' as the name of the executable");
1408 Write_Line (" -b target Compile the binder source to run on target");
1409 Write_Line (" -Bdir Load compiler executables from dir");
1411 if Is_Supported (Map_File) then
1412 Write_Line (" -Mmap Create map file map");
1413 Write_Line (" -M Create map file mainprog.map");
1414 end if;
1416 Write_Line (" --GCC=comp Use comp as the compiler");
1417 Write_Line (" --LINK=nam Use 'nam' for the linking rather than 'gcc'");
1418 Write_Eol;
1419 Write_Line (" [non-Ada-objects] list of non Ada object files");
1420 Write_Line (" [linker-options] other options for the linker");
1421 end Usage;
1423 ------------------
1424 -- Write_Header --
1425 ------------------
1427 procedure Write_Header is
1428 begin
1429 if Verbose_Mode then
1430 Write_Eol;
1431 Display_Version ("GNATLINK", "1995");
1432 end if;
1433 end Write_Header;
1435 -----------------
1436 -- Write_Usage --
1437 -----------------
1439 procedure Write_Usage is
1440 begin
1441 Write_Header;
1442 Usage;
1443 end Write_Usage;
1445 -- Start of processing for Gnatlink
1447 begin
1448 -- Add the directory where gnatlink is invoked in front of the path, if
1449 -- gnatlink is invoked with directory information.
1451 declare
1452 Command : constant String := Command_Name;
1453 begin
1454 for Index in reverse Command'Range loop
1455 if Command (Index) = Directory_Separator then
1456 declare
1457 Absolute_Dir : constant String :=
1458 Normalize_Pathname
1459 (Command (Command'First .. Index));
1461 PATH : constant String :=
1462 Absolute_Dir &
1463 Path_Separator &
1464 Getenv ("PATH").all;
1466 begin
1467 Setenv ("PATH", PATH);
1468 end;
1470 exit;
1471 end if;
1472 end loop;
1473 end;
1475 Base_Command_Name := new String'(Base_Name (Command_Name));
1476 Process_Args;
1478 if Argument_Count = 0
1479 or else (Verbose_Mode and then Argument_Count = 1)
1480 then
1481 Write_Usage;
1482 Exit_Program (E_Fatal);
1483 end if;
1485 -- Initialize packages to be used
1487 Csets.Initialize;
1488 Snames.Initialize;
1490 -- We always compile with -c
1492 Binder_Options_From_ALI.Increment_Last;
1493 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1494 new String'("-c");
1496 if Ali_File_Name = null then
1497 Exit_With_Error ("no ali file given for link");
1498 end if;
1500 if not Is_Regular_File (Ali_File_Name.all) then
1501 Exit_With_Error (Ali_File_Name.all & " not found");
1502 end if;
1504 -- Read the ALI file of the main subprogram if the binder generated file
1505 -- needs to be compiled and no --GCC= switch has been specified. Fetch the
1506 -- back end switches from this ALI file and use these switches to compile
1507 -- the binder generated file
1509 if Compile_Bind_File and then Standard_Gcc then
1510 Initialize_ALI;
1511 Name_Len := Ali_File_Name'Length;
1512 Name_Buffer (1 .. Name_Len) := Ali_File_Name.all;
1514 declare
1515 use Types;
1516 F : constant File_Name_Type := Name_Find;
1517 T : Text_Buffer_Ptr;
1518 A : ALI_Id;
1520 begin
1521 -- Load the ALI file
1523 T := Read_Library_Info (F, True);
1525 -- Read it. Note that we ignore errors, since we only want very
1526 -- limited information from the ali file, and likely a slightly
1527 -- wrong version will be just fine, though in normal operation
1528 -- we don't expect this to happen.
1530 A := Scan_ALI
1533 Ignore_ED => False,
1534 Err => False,
1535 Ignore_Errors => True);
1537 if A /= No_ALI_Id then
1539 Index in Units.Table (ALIs.Table (A).First_Unit).First_Arg ..
1540 Units.Table (ALIs.Table (A).First_Unit).Last_Arg
1541 loop
1542 -- Do not compile with the front end switches. However, --RTS
1543 -- is to be dealt with specially because it needs to be passed
1544 -- to compile the file generated by the binder.
1546 declare
1547 Arg : String_Ptr renames Args.Table (Index);
1548 begin
1549 if not Is_Front_End_Switch (Arg.all) then
1550 Binder_Options_From_ALI.Increment_Last;
1551 Binder_Options_From_ALI.Table
1552 (Binder_Options_From_ALI.Last) := String_Access (Arg);
1554 -- GNAT doesn't support GCC's multilib mechanism when it
1555 -- is configured with --disable-libada. This means that,
1556 -- when a multilib switch is used to request a particular
1557 -- compilation mode, the corresponding --RTS switch must
1558 -- also be specified. It is convenient to eliminate the
1559 -- redundancy by keying the compilation mode on a single
1560 -- switch, namely --RTS, and have the compiler reinstate
1561 -- the multilib switch (see gcc-interface/lang-specs.h).
1562 -- This switch must be passed to the driver at link time.
1564 if Arg'Length = 5
1565 and then Arg (Arg'First + 1 .. Arg'First + 4) = "mrtp"
1566 then
1567 Linker_Options.Increment_Last;
1568 Linker_Options.Table
1569 (Linker_Options.Last) := String_Access (Arg);
1570 end if;
1572 elsif Arg'Length > 5
1573 and then Arg (Arg'First + 2 .. Arg'First + 5) = "RTS="
1574 then
1575 Binder_Options_From_ALI.Increment_Last;
1576 Binder_Options_From_ALI.Table
1577 (Binder_Options_From_ALI.Last) := String_Access (Arg);
1579 -- Set the RTS_*_Path_Name variables, so that
1580 -- the correct directories will be set when
1581 -- Osint.Add_Default_Search_Dirs will be called later.
1583 Opt.RTS_Src_Path_Name :=
1584 Get_RTS_Search_Dir
1585 (Arg (Arg'First + 6 .. Arg'Last), Include);
1587 Opt.RTS_Lib_Path_Name :=
1588 Get_RTS_Search_Dir
1589 (Arg (Arg'First + 6 .. Arg'Last), Objects);
1590 end if;
1591 end;
1592 end loop;
1593 end if;
1594 end;
1595 end if;
1597 -- Get target parameters
1599 Osint.Add_Default_Search_Dirs;
1600 Targparm.Get_Target_Parameters;
1602 -- Compile the bind file with the following switches:
1604 -- -gnatA stops reading gnat.adc, since we don't know what
1605 -- pragmas would work, and we do not need it anyway.
1607 -- -gnatWb allows brackets coding for wide characters
1609 -- -gnatiw allows wide characters in identifiers. This is needed
1610 -- because bindgen uses brackets encoding for all upper
1611 -- half and wide characters in identifier names.
1613 -- In addition, in CodePeer mode compile with -x adascil -gnatcC
1615 Binder_Options_From_ALI.Increment_Last;
1616 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1617 new String'("-gnatA");
1618 Binder_Options_From_ALI.Increment_Last;
1619 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1620 new String'("-gnatWb");
1621 Binder_Options_From_ALI.Increment_Last;
1622 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1623 new String'("-gnatiw");
1625 if Opt.CodePeer_Mode then
1626 Binder_Options_From_ALI.Increment_Last;
1627 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1628 new String'("-x");
1629 Binder_Options_From_ALI.Increment_Last;
1630 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1631 new String'("adascil");
1632 Binder_Options_From_ALI.Increment_Last;
1633 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1634 new String'("-gnatcC");
1635 end if;
1637 -- Locate all the necessary programs and verify required files are present
1639 Gcc_Path := System.OS_Lib.Locate_Exec_On_Path (Gcc.all);
1641 if Gcc_Path = null then
1642 Exit_With_Error ("Couldn't locate " & Gcc.all);
1643 end if;
1645 if Linker_Path = null then
1646 Linker_Path := Gcc_Path;
1647 end if;
1649 Write_Header;
1651 Target_Debuggable_Suffix := Get_Target_Debuggable_Suffix;
1653 -- If no output name specified, then use the base name of .ali file name
1655 if Output_File_Name = null then
1656 Output_File_Name :=
1657 new String'(Base_Name (Ali_File_Name.all)
1658 & Target_Debuggable_Suffix.all);
1659 end if;
1661 Linker_Options.Increment_Last;
1662 Linker_Options.Table (Linker_Options.Last) := new String'("-o");
1664 Linker_Options.Increment_Last;
1665 Linker_Options.Table (Linker_Options.Last) :=
1666 new String'(Output_File_Name.all);
1668 Check_Existing_Executable (Output_File_Name.all);
1670 -- Warn if main program is called "test", as that may be a built-in command
1671 -- on Unix. On non-Unix systems executables have a suffix, so the warning
1672 -- will not appear. However, do not warn in the case of a cross compiler.
1674 -- Assume this is a cross tool if the executable name is not gnatlink.
1675 -- Note that the executable name is also gnatlink on windows, but in that
1676 -- case the output file name will be test.exe rather than test.
1678 if Base_Command_Name.all = "gnatlink"
1679 and then Output_File_Name.all = "test"
1680 then
1681 Error_Msg ("warning: executable name """ & Output_File_Name.all
1682 & """ may conflict with shell command");
1683 end if;
1685 -- Special warnings for worrisome file names on windows
1687 -- Recent versions of Windows by default cause privilege escalation if an
1688 -- executable file name contains substrings "install", "setup", "update"
1689 -- or "patch". A console application will typically fail to load as a
1690 -- result, so we should warn the user.
1692 Bad_File_Names_On_Windows : declare
1693 FN : String := Output_File_Name.all;
1695 procedure Check_File_Name (S : String);
1696 -- Warn if file name has the substring S
1698 procedure Check_File_Name (S : String) is
1699 begin
1700 for J in 1 .. FN'Length - (S'Length - 1) loop
1701 if FN (J .. J + (S'Length - 1)) = S then
1702 Error_Msg
1703 ("warning: executable file name """ & Output_File_Name.all
1704 & """ contains substring """ & S & '"');
1705 Error_Msg
1706 ("admin privileges may be required to run this file");
1707 end if;
1708 end loop;
1709 end Check_File_Name;
1711 -- Start of processing for Bad_File_Names_On_Windows
1713 begin
1714 for J in FN'Range loop
1715 FN (J) := Csets.Fold_Lower (FN (J));
1716 end loop;
1718 -- For now we detect Windows by its executable suffix of .exe
1720 if Target_Debuggable_Suffix.all = ".exe" then
1721 Check_File_Name ("install");
1722 Check_File_Name ("setup");
1723 Check_File_Name ("update");
1724 Check_File_Name ("patch");
1725 end if;
1726 end Bad_File_Names_On_Windows;
1728 -- If -M switch was specified, add the switches to create the map file
1730 if Create_Map_File then
1731 declare
1732 Map_Name : constant String := Base_Name (Ali_File_Name.all) & ".map";
1733 Switches : String_List_Access;
1735 begin
1736 Convert (Map_File, Map_Name, Switches);
1738 if Switches /= null then
1739 for J in Switches'Range loop
1740 Linker_Options.Increment_Last;
1741 Linker_Options.Table (Linker_Options.Last) := Switches (J);
1742 end loop;
1743 end if;
1744 end;
1745 end if;
1747 -- Perform consistency checks
1749 -- Transform the .ali file name into the binder output file name
1751 Make_Binder_File_Names : declare
1752 Fname : constant String := Base_Name (Ali_File_Name.all);
1753 Fname_Len : Integer := Fname'Length;
1755 function Get_Maximum_File_Name_Length return Integer;
1756 pragma Import (C, Get_Maximum_File_Name_Length,
1757 "__gnat_get_maximum_file_name_length");
1759 Maximum_File_Name_Length : constant Integer :=
1760 Get_Maximum_File_Name_Length;
1762 Bind_File_Prefix : Types.String_Ptr;
1763 -- Contains prefix used for bind files
1765 begin
1766 -- Set prefix
1768 Bind_File_Prefix := new String'("b~");
1770 -- If the length of the binder file becomes too long due to
1771 -- the addition of the "b?" prefix, then truncate it.
1773 if Maximum_File_Name_Length > 0 then
1774 while Fname_Len >
1775 Maximum_File_Name_Length - Bind_File_Prefix.all'Length
1776 loop
1777 Fname_Len := Fname_Len - 1;
1778 end loop;
1779 end if;
1781 declare
1782 Fnam : constant String :=
1783 Bind_File_Prefix.all &
1784 Fname (Fname'First .. Fname'First + Fname_Len - 1);
1786 begin
1787 Binder_Spec_Src_File := new String'(Fnam & ".ads");
1788 Binder_Body_Src_File := new String'(Fnam & ".adb");
1789 Binder_Ali_File := new String'(Fnam & ".ali");
1791 Binder_Obj_File := new String'(Fnam & Get_Target_Object_Suffix.all);
1792 end;
1794 if Fname_Len /= Fname'Length then
1795 Binder_Options.Increment_Last;
1796 Binder_Options.Table (Binder_Options.Last) := new String'("-o");
1797 Binder_Options.Increment_Last;
1798 Binder_Options.Table (Binder_Options.Last) := Binder_Obj_File;
1799 end if;
1800 end Make_Binder_File_Names;
1802 Process_Binder_File (Binder_Body_Src_File.all & ASCII.NUL);
1804 -- Compile the binder file. This is fast, so we always do it, unless
1805 -- specifically told not to by the -n switch
1807 if Compile_Bind_File then
1808 Bind_Step : declare
1809 Success : Boolean;
1811 Args : Argument_List
1812 (1 .. Binder_Options_From_ALI.Last + Binder_Options.Last + 1);
1814 begin
1815 for J in 1 .. Binder_Options_From_ALI.Last loop
1816 Args (J) := Binder_Options_From_ALI.Table (J);
1817 end loop;
1819 for J in 1 .. Binder_Options.Last loop
1820 Args (Binder_Options_From_ALI.Last + J) :=
1821 Binder_Options.Table (J);
1822 end loop;
1824 -- Use the full path of the binder generated source, so that it is
1825 -- guaranteed that the debugger will find this source, even with
1826 -- STABS.
1828 Args (Args'Last) :=
1829 new String'(Normalize_Pathname (Binder_Body_Src_File.all));
1831 if Verbose_Mode then
1832 Write_Str (Base_Name (Gcc_Path.all));
1834 for J in Args'Range loop
1835 Write_Str (" ");
1836 Write_Str (Args (J).all);
1837 end loop;
1839 Write_Eol;
1840 end if;
1842 System.OS_Lib.Spawn (Gcc_Path.all, Args, Success);
1844 if not Success then
1845 Exit_Program (E_Fatal);
1846 end if;
1847 end Bind_Step;
1848 end if;
1850 -- In CodePeer mode, there's nothing left to do after the binder file has
1851 -- been compiled.
1853 if Opt.CodePeer_Mode then
1854 if Tname_FD /= Invalid_FD then
1855 Delete (Tname);
1856 end if;
1858 return;
1859 end if;
1861 -- Now, actually link the program
1863 Link_Step : declare
1864 Num_Args : Natural :=
1865 (Linker_Options.Last - Linker_Options.First + 1) +
1866 (Gcc_Linker_Options.Last - Gcc_Linker_Options.First + 1) +
1867 (Linker_Objects.Last - Linker_Objects.First + 1);
1868 Stack_Op : Boolean := False;
1870 begin
1871 -- Remove duplicate stack size setting from the Linker_Options table.
1872 -- The stack setting option "-Xlinker --stack=R,C" can be found
1873 -- in one line when set by a pragma Linker_Options or in two lines
1874 -- ("-Xlinker" then "--stack=R,C") when set on the command line. We
1875 -- also check for the "-Wl,--stack=R" style option.
1877 -- We must remove the second stack setting option instance because
1878 -- the one on the command line will always be the first one. And any
1879 -- subsequent stack setting option will overwrite the previous one.
1880 -- This is done especially for GNAT/NT where we set the stack size
1881 -- for tasking programs by a pragma in the NT specific tasking
1882 -- package System.Task_Primitives.Operations.
1884 -- Note: This is not a FOR loop that runs from Linker_Options.First
1885 -- to Linker_Options.Last, since operations within the loop can
1886 -- modify the length of the table.
1888 Clean_Link_Option_Set : declare
1889 J : Natural;
1890 Shared_Libgcc_Seen : Boolean := False;
1892 begin
1893 J := Linker_Options.First;
1894 while J <= Linker_Options.Last loop
1895 if Linker_Options.Table (J).all = "-Xlinker"
1896 and then J < Linker_Options.Last
1897 and then Linker_Options.Table (J + 1)'Length > 8
1898 and then Linker_Options.Table (J + 1) (1 .. 8) = "--stack="
1899 then
1900 if Stack_Op then
1901 Linker_Options.Table (J .. Linker_Options.Last - 2) :=
1902 Linker_Options.Table (J + 2 .. Linker_Options.Last);
1903 Linker_Options.Decrement_Last;
1904 Linker_Options.Decrement_Last;
1905 Num_Args := Num_Args - 2;
1907 else
1908 Stack_Op := True;
1909 end if;
1910 end if;
1912 -- Remove duplicate -shared-libgcc switch
1914 if Linker_Options.Table (J).all = Shared_Libgcc_String then
1915 if Shared_Libgcc_Seen then
1916 Linker_Options.Table (J .. Linker_Options.Last - 1) :=
1917 Linker_Options.Table (J + 1 .. Linker_Options.Last);
1918 Linker_Options.Decrement_Last;
1919 Num_Args := Num_Args - 1;
1921 else
1922 Shared_Libgcc_Seen := True;
1923 end if;
1924 end if;
1926 -- Here we just check for a canonical form that matches the
1927 -- pragma Linker_Options set in the NT runtime.
1929 if (Linker_Options.Table (J)'Length > 17
1930 and then Linker_Options.Table (J) (1 .. 17) =
1931 "-Xlinker --stack=")
1932 or else
1933 (Linker_Options.Table (J)'Length > 12
1934 and then Linker_Options.Table (J) (1 .. 12) =
1935 "-Wl,--stack=")
1936 then
1937 if Stack_Op then
1938 Linker_Options.Table (J .. Linker_Options.Last - 1) :=
1939 Linker_Options.Table (J + 1 .. Linker_Options.Last);
1940 Linker_Options.Decrement_Last;
1941 Num_Args := Num_Args - 1;
1943 else
1944 Stack_Op := True;
1945 end if;
1946 end if;
1948 J := J + 1;
1949 end loop;
1951 if Linker_Path = Gcc_Path then
1953 -- For systems where the default is to link statically with
1954 -- libgcc, if gcc is not called with -shared-libgcc, call it
1955 -- with -static-libgcc, as there are some platforms where one
1956 -- of these two switches is compulsory to link.
1958 if Shared_Libgcc_Default = 'T'
1959 and then not Shared_Libgcc_Seen
1960 then
1961 Linker_Options.Increment_Last;
1962 Linker_Options.Table (Linker_Options.Last) := Static_Libgcc;
1963 Num_Args := Num_Args + 1;
1964 end if;
1965 end if;
1966 end Clean_Link_Option_Set;
1968 -- Prepare arguments for call to linker
1970 Call_Linker : declare
1971 Success : Boolean;
1972 Args : Argument_List (1 .. Num_Args + 1);
1973 Index : Integer := Args'First;
1975 begin
1976 Args (Index) := Binder_Obj_File;
1978 -- Add the object files and any -largs libraries
1980 for J in Linker_Objects.First .. Linker_Objects.Last loop
1981 Index := Index + 1;
1982 Args (Index) := Linker_Objects.Table (J);
1983 end loop;
1985 -- Add the linker options from the binder file
1987 for J in Linker_Options.First .. Linker_Options.Last loop
1988 Index := Index + 1;
1989 Args (Index) := Linker_Options.Table (J);
1990 end loop;
1992 -- Finally add the libraries from the --GCC= switch
1994 for J in Gcc_Linker_Options.First .. Gcc_Linker_Options.Last loop
1995 Index := Index + 1;
1996 Args (Index) := Gcc_Linker_Options.Table (J);
1997 end loop;
1999 if Verbose_Mode then
2000 Write_Str (Linker_Path.all);
2002 for J in Args'Range loop
2003 Write_Str (" ");
2004 Write_Str (Args (J).all);
2005 end loop;
2007 Write_Eol;
2009 -- If we are on very verbose mode (-v -v) and a response file
2010 -- is used we display its content.
2012 if Very_Verbose_Mode and then Tname_FD /= Invalid_FD then
2013 Write_Eol;
2014 Write_Str ("Response file (" &
2015 Tname (Tname'First .. Tname'Last - 1) &
2016 ") content : ");
2017 Write_Eol;
2019 for J in
2020 Response_File_Objects.First .. Response_File_Objects.Last
2021 loop
2022 Write_Str (Response_File_Objects.Table (J).all);
2023 Write_Eol;
2024 end loop;
2026 Write_Eol;
2027 end if;
2028 end if;
2030 System.OS_Lib.Spawn (Linker_Path.all, Args, Success);
2032 -- Delete the temporary file used in conjunction with linking if one
2033 -- was created. See Process_Bind_File for details.
2035 if Tname_FD /= Invalid_FD then
2036 Delete (Tname);
2037 end if;
2039 if not Success then
2040 Error_Msg ("error when calling " & Linker_Path.all);
2041 Exit_Program (E_Fatal);
2042 end if;
2043 end Call_Linker;
2044 end Link_Step;
2046 -- Only keep the binder output file and it's associated object
2047 -- file if compiling with the -g option. These files are only
2048 -- useful if debugging.
2050 if not Debug_Flag_Present then
2051 Delete (Binder_Ali_File.all & ASCII.NUL);
2052 Delete (Binder_Spec_Src_File.all & ASCII.NUL);
2053 Delete (Binder_Body_Src_File.all & ASCII.NUL);
2054 Delete (Binder_Obj_File.all & ASCII.NUL);
2055 end if;
2057 Exit_Program (E_Success);
2059 exception
2060 when X : others =>
2061 Write_Line (Exception_Information (X));
2062 Exit_With_Error ("INTERNAL ERROR. Please report");
2063 end Gnatlink;