2009-07-17 Richard Guenther <rguenther@suse.de>
[official-gcc.git] / gcc / ada / par-load.adb
blob9aa084238054cacad1fa77fac9fd0412ada380f3
1 ------------------------------------------------------------------------------
2 -- --
3 -- GNAT COMPILER COMPONENTS --
4 -- --
5 -- P A R . L O A D --
6 -- --
7 -- B o d y --
8 -- --
9 -- Copyright (C) 1992-2009, Free Software Foundation, Inc. --
10 -- --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License --
17 -- for more details. You should have received a copy of the GNU General --
18 -- Public License distributed with GNAT; see file COPYING3. If not, go to --
19 -- http://www.gnu.org/licenses for a complete copy of the license. --
20 -- --
21 -- GNAT was originally developed by the GNAT team at New York University. --
22 -- Extensive contributions were provided by Ada Core Technologies Inc. --
23 -- --
24 ------------------------------------------------------------------------------
26 -- The Par.Load procedure loads all units that are definitely required before
27 -- it makes any sense at all to proceed with semantic analysis, including
28 -- with'ed units, corresponding specs for bodies, parents of child specs,
29 -- and parents of subunits. All these units are loaded and pointers installed
30 -- in the tree as described in the spec of package Lib.
32 with Fname.UF; use Fname.UF;
33 with Lib.Load; use Lib.Load;
34 with Namet.Sp; use Namet.Sp;
35 with Uname; use Uname;
36 with Osint; use Osint;
37 with Sinput.L; use Sinput.L;
38 with Stylesw; use Stylesw;
39 with Validsw; use Validsw;
41 with GNAT.Spelling_Checker; use GNAT.Spelling_Checker;
43 separate (Par)
44 procedure Load is
46 File_Name : File_Name_Type;
47 -- Name of file for current unit, derived from unit name
49 Cur_Unum : constant Unit_Number_Type := Current_Source_Unit;
50 -- Unit number of unit that we just finished parsing. Note that we need
51 -- to capture this, because Source_Unit will change as we parse new
52 -- source files in the multiple main source file case.
54 Curunit : constant Node_Id := Cunit (Cur_Unum);
55 -- Compilation unit node for current compilation unit
57 Loc : Source_Ptr := Sloc (Curunit);
58 -- Source location for compilation unit node
60 Save_Style_Check : Boolean;
61 Save_Style_Checks : Style_Check_Options;
62 -- Save style check so it can be restored later
64 Save_Validity_Check : Boolean;
65 Save_Validity_Checks : Validity_Check_Options;
66 -- Save validity check so it can be restored later
68 With_Cunit : Node_Id;
69 -- Compilation unit node for withed unit
71 Context_Node : Node_Id;
72 -- Next node in context items list
74 With_Node : Node_Id;
75 -- N_With_Clause node
77 Spec_Name : Unit_Name_Type;
78 -- Unit name of required spec
80 Body_Name : Unit_Name_Type;
81 -- Unit name of corresponding body
83 Unum : Unit_Number_Type;
84 -- Unit number of loaded unit
86 Limited_With_Found : Boolean := False;
87 -- We load the context items in two rounds: the first round handles normal
88 -- withed units and the second round handles Ada 2005 limited-withed units.
89 -- This is required to allow the low-level circuitry that detects circular
90 -- dependencies of units the correct notification of errors (see comment
91 -- bellow). This variable is used to indicate that the second round is
92 -- required.
94 function Same_File_Name_Except_For_Case
95 (Expected_File_Name : File_Name_Type;
96 Actual_File_Name : File_Name_Type) return Boolean;
97 -- Given an actual file name and an expected file name (the latter being
98 -- derived from the unit name), determine if they are the same except for
99 -- possibly different casing of letters.
101 ------------------------------------
102 -- Same_File_Name_Except_For_Case --
103 ------------------------------------
105 function Same_File_Name_Except_For_Case
106 (Expected_File_Name : File_Name_Type;
107 Actual_File_Name : File_Name_Type) return Boolean
109 begin
110 Get_Name_String (Actual_File_Name);
111 Canonical_Case_File_Name (Name_Buffer (1 .. Name_Len));
113 declare
114 Lower_Case_Actual_File_Name : String (1 .. Name_Len);
116 begin
117 Lower_Case_Actual_File_Name := Name_Buffer (1 .. Name_Len);
118 Get_Name_String (Expected_File_Name);
119 Canonical_Case_File_Name (Name_Buffer (1 .. Name_Len));
120 return Lower_Case_Actual_File_Name = Name_Buffer (1 .. Name_Len);
121 end;
123 end Same_File_Name_Except_For_Case;
125 -- Start of processing for Load
127 begin
128 -- Don't do any loads if we already had a fatal error
130 if Fatal_Error (Cur_Unum) then
131 return;
132 end if;
134 Save_Style_Check_Options (Save_Style_Checks);
135 Save_Style_Check := Opt.Style_Check;
137 Save_Validity_Check_Options (Save_Validity_Checks);
138 Save_Validity_Check := Opt.Validity_Checks_On;
140 -- If main unit, set Main_Unit_Entity (this will get overwritten if
141 -- the main unit has a separate spec, that happens later on in Load)
143 if Cur_Unum = Main_Unit then
144 Main_Unit_Entity := Cunit_Entity (Main_Unit);
145 end if;
147 -- If we have no unit name, things are seriously messed up by previous
148 -- errors, and we should not try to continue compilation.
150 if Unit_Name (Cur_Unum) = No_Unit_Name then
151 raise Unrecoverable_Error;
152 end if;
154 -- Next step, make sure that the unit name matches the file name
155 -- and issue a warning message if not. We only output this for the
156 -- main unit, since for other units it is more serious and is
157 -- caught in a separate test below. We also inhibit the message in
158 -- multiple unit per file mode, because in this case the relation
159 -- between file name and unit name is broken.
161 File_Name :=
162 Get_File_Name
163 (Unit_Name (Cur_Unum),
164 Subunit => Nkind (Unit (Cunit (Cur_Unum))) = N_Subunit);
166 if Cur_Unum = Main_Unit
167 and then Multiple_Unit_Index = 0
168 and then File_Name /= Unit_File_Name (Cur_Unum)
169 and then (File_Names_Case_Sensitive
170 or not Same_File_Name_Except_For_Case
171 (File_Name, Unit_File_Name (Cur_Unum)))
172 then
173 Error_Msg_File_1 := File_Name;
174 Error_Msg
175 ("?file name does not match unit name, should be{", Sloc (Curunit));
176 end if;
178 -- For units other than the main unit, the expected unit name is set and
179 -- must be the same as the actual unit name, or we are in big trouble, and
180 -- abandon the compilation since there are situations where this really
181 -- gets us into bad trouble (e.g. some subunit situations).
183 if Cur_Unum /= Main_Unit
184 and then Expected_Unit (Cur_Unum) /= Unit_Name (Cur_Unum)
185 then
186 Loc := Error_Location (Cur_Unum);
187 Error_Msg_File_1 := Unit_File_Name (Cur_Unum);
188 Get_Name_String (Error_Msg_File_1);
190 -- Check for predefined file case
192 if Name_Len > 1
193 and then Name_Buffer (2) = '-'
194 and then (Name_Buffer (1) = 'a'
195 or else
196 Name_Buffer (1) = 's'
197 or else
198 Name_Buffer (1) = 'i'
199 or else
200 Name_Buffer (1) = 'g')
201 then
202 declare
203 Expect_Name : constant Unit_Name_Type := Expected_Unit (Cur_Unum);
204 Actual_Name : constant Unit_Name_Type := Unit_Name (Cur_Unum);
206 begin
207 Error_Msg_Unit_1 := Expect_Name;
208 Error_Msg -- CODEFIX
209 ("$$ is not a predefined library unit!", Loc);
211 -- In the predefined file case, we know the user did not
212 -- construct their own package, but we got the wrong one.
213 -- This means that the name supplied by the user crunched
214 -- to something we recognized, but then the file did not
215 -- contain the unit expected. Most likely this is due to
216 -- a misspelling, e.g.
218 -- with Ada.Calender;
220 -- This crunches to a-calend, which indeed contains the unit
221 -- Ada.Calendar, and we can diagnose the misspelling. This
222 -- is a simple heuristic, but it catches many common cases
223 -- of misspelling of predefined unit names without needing
224 -- a full list of them.
226 -- Before actually issuing the message, we will check that the
227 -- unit name is indeed a plausible misspelling of the one we got.
229 if Is_Bad_Spelling_Of
230 (Name_Id (Expect_Name), Name_Id (Actual_Name))
231 then
232 Error_Msg_Unit_1 := Actual_Name;
233 Error_Msg -- CODEFIX
234 ("possible misspelling of $$!", Loc);
235 end if;
236 end;
238 -- Non-predefined file name case. In this case we generate a message
239 -- and then we quit, because we are in big trouble, and if we try
240 -- to continue compilation, we get into some nasty situations
241 -- (for example in some subunit cases).
243 else
244 Error_Msg ("file { does not contain expected unit!", Loc);
245 Error_Msg_Unit_1 := Expected_Unit (Cur_Unum);
246 Error_Msg ("\\expected unit $!", Loc);
247 Error_Msg_Unit_1 := Unit_Name (Cur_Unum);
248 Error_Msg ("\\found unit $!", Loc);
249 end if;
251 -- In both cases, remove the unit if it is the last unit (which it
252 -- normally (always?) will be) so that it is out of the way later.
254 Remove_Unit (Cur_Unum);
255 end if;
257 -- If current unit is a body, load its corresponding spec
259 if Nkind (Unit (Curunit)) = N_Package_Body
260 or else Nkind (Unit (Curunit)) = N_Subprogram_Body
261 then
262 Spec_Name := Get_Spec_Name (Unit_Name (Cur_Unum));
263 Unum :=
264 Load_Unit
265 (Load_Name => Spec_Name,
266 Required => False,
267 Subunit => False,
268 Error_Node => Curunit,
269 Corr_Body => Cur_Unum);
271 -- If we successfully load the unit, then set the spec/body
272 -- pointers. Once again note that if the loaded unit has a fatal error,
273 -- Load will have set our Fatal_Error flag to propagate this condition.
275 if Unum /= No_Unit then
276 Set_Library_Unit (Curunit, Cunit (Unum));
277 Set_Library_Unit (Cunit (Unum), Curunit);
279 -- If this is a separate spec for the main unit, then we reset
280 -- Main_Unit_Entity to point to the entity for this separate spec
281 -- and this is also where we generate the SCO's for this spec.
283 if Cur_Unum = Main_Unit then
284 Main_Unit_Entity := Cunit_Entity (Unum);
286 if Generate_SCO then
287 SCO_Record (Unum);
288 end if;
289 end if;
291 -- If we don't find the spec, then if we have a subprogram body, we
292 -- are still OK, we just have a case of a body acting as its own spec
294 elsif Nkind (Unit (Curunit)) = N_Subprogram_Body then
295 Set_Acts_As_Spec (Curunit, True);
296 Set_Library_Unit (Curunit, Curunit);
298 -- Otherwise we do have an error, repeat the load request for the spec
299 -- with Required set True to generate an appropriate error message.
301 else
302 Unum :=
303 Load_Unit
304 (Load_Name => Spec_Name,
305 Required => True,
306 Subunit => False,
307 Error_Node => Curunit);
308 return;
309 end if;
311 -- If current unit is a child unit spec, load its parent. If the child unit
312 -- is loaded through a limited with, the parent must be as well.
314 elsif Nkind (Unit (Curunit)) = N_Package_Declaration
315 or else Nkind (Unit (Curunit)) = N_Subprogram_Declaration
316 or else Nkind (Unit (Curunit)) in N_Generic_Declaration
317 or else Nkind (Unit (Curunit)) in N_Generic_Instantiation
318 or else Nkind (Unit (Curunit)) in N_Renaming_Declaration
319 then
320 -- Turn style and validity checks off for parent unit
322 if not GNAT_Mode then
323 Reset_Style_Check_Options;
324 Reset_Validity_Check_Options;
325 end if;
327 Spec_Name := Get_Parent_Spec_Name (Unit_Name (Cur_Unum));
329 if Spec_Name /= No_Unit_Name then
330 Unum :=
331 Load_Unit
332 (Load_Name => Spec_Name,
333 Required => True,
334 Subunit => False,
335 Error_Node => Curunit);
337 if Unum /= No_Unit then
338 Set_Parent_Spec (Unit (Curunit), Cunit (Unum));
339 end if;
340 end if;
342 -- If current unit is a subunit, then load its parent body
344 elsif Nkind (Unit (Curunit)) = N_Subunit then
345 Body_Name := Get_Parent_Body_Name (Unit_Name (Cur_Unum));
346 Unum :=
347 Load_Unit
348 (Load_Name => Body_Name,
349 Required => True,
350 Subunit => True,
351 Error_Node => Name (Unit (Curunit)));
353 if Unum /= No_Unit then
354 Set_Library_Unit (Curunit, Cunit (Unum));
355 end if;
356 end if;
358 -- Now we load with'ed units, with style/validity checks turned off
360 if not GNAT_Mode then
361 Reset_Style_Check_Options;
362 Reset_Validity_Check_Options;
363 end if;
365 -- Load the context items in two rounds: the first round handles normal
366 -- withed units and the second round handles Ada 2005 limited-withed units.
367 -- This is required to allow the low-level circuitry that detects circular
368 -- dependencies of units the correct notification of the following error:
370 -- limited with D;
371 -- with D; with C;
372 -- package C is ... package D is ...
374 for Round in 1 .. 2 loop
375 Context_Node := First (Context_Items (Curunit));
376 while Present (Context_Node) loop
378 -- During the first round we check if there is some limited-with
379 -- context clause; otherwise the second round will be skipped
381 if Nkind (Context_Node) = N_With_Clause
382 and then Round = 1
383 and then Limited_Present (Context_Node)
384 then
385 Limited_With_Found := True;
386 end if;
388 if Nkind (Context_Node) = N_With_Clause
389 and then ((Round = 1 and then not Limited_Present (Context_Node))
390 or else
391 (Round = 2 and then Limited_Present (Context_Node)))
392 then
393 With_Node := Context_Node;
394 Spec_Name := Get_Unit_Name (With_Node);
396 Unum :=
397 Load_Unit
398 (Load_Name => Spec_Name,
399 Required => False,
400 Subunit => False,
401 Error_Node => With_Node,
402 Renamings => True,
403 With_Node => Context_Node);
405 -- If we find the unit, then set spec pointer in the N_With_Clause
406 -- to point to the compilation unit for the spec. Remember that
407 -- the Load routine itself sets our Fatal_Error flag if the loaded
408 -- unit gets a fatal error, so we don't need to worry about that.
410 if Unum /= No_Unit then
411 Set_Library_Unit (With_Node, Cunit (Unum));
413 -- If the spec isn't found, then try finding the corresponding
414 -- body, since it is possible that we have a subprogram body
415 -- that is acting as a spec (since no spec is present).
417 else
418 Body_Name := Get_Body_Name (Spec_Name);
419 Unum :=
420 Load_Unit
421 (Load_Name => Body_Name,
422 Required => False,
423 Subunit => False,
424 Error_Node => With_Node,
425 Renamings => True);
427 -- If we got a subprogram body, then mark that we are using
428 -- the body as a spec in the file table, and set the spec
429 -- pointer in the N_With_Clause to point to the body entity.
431 if Unum /= No_Unit
432 and then Nkind (Unit (Cunit (Unum))) = N_Subprogram_Body
433 then
434 With_Cunit := Cunit (Unum);
435 Set_Library_Unit (With_Node, With_Cunit);
436 Set_Acts_As_Spec (With_Cunit, True);
437 Set_Library_Unit (With_Cunit, With_Cunit);
439 -- If we couldn't find the body, or if it wasn't a body spec
440 -- then we are in trouble. We make one more call to Load to
441 -- require the spec. We know it will fail of course, the
442 -- purpose is to generate the required error message (we prefer
443 -- that this message refer to the missing spec, not the body)
445 else
446 Unum :=
447 Load_Unit
448 (Load_Name => Spec_Name,
449 Required => True,
450 Subunit => False,
451 Error_Node => With_Node,
452 Renamings => True);
454 -- Here we create a dummy package unit for the missing unit
456 Unum := Create_Dummy_Package_Unit (With_Node, Spec_Name);
457 Set_Library_Unit (With_Node, Cunit (Unum));
458 end if;
459 end if;
460 end if;
462 Next (Context_Node);
463 end loop;
465 exit when not Limited_With_Found;
466 end loop;
468 -- Restore style/validity check mode for main unit
470 Set_Style_Check_Options (Save_Style_Checks);
471 Opt.Style_Check := Save_Style_Check;
472 Set_Validity_Check_Options (Save_Validity_Checks);
473 Opt.Validity_Checks_On := Save_Validity_Check;
474 end Load;