2008-05-30 Vladimir Makarov <vmakarov@redhat.com>
[official-gcc.git] / gcc / ada / erroutc.adb
blobf255ac00e9e7436e935a7a8c9d185a6cb26085c4
1 ------------------------------------------------------------------------------
2 -- --
3 -- GNAT COMPILER COMPONENTS --
4 -- --
5 -- E R R O U T C --
6 -- --
7 -- B o d y --
8 -- --
9 -- Copyright (C) 1992-2008, Free Software Foundation, Inc. --
10 -- --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 2, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License --
17 -- for more details. You should have received a copy of the GNU General --
18 -- Public License distributed with GNAT; see file COPYING. If not, write --
19 -- to the Free Software Foundation, 51 Franklin Street, Fifth Floor, --
20 -- Boston, MA 02110-1301, USA. --
21 -- --
22 -- GNAT was originally developed by the GNAT team at New York University. --
23 -- Extensive contributions were provided by Ada Core Technologies Inc. --
24 -- --
25 ------------------------------------------------------------------------------
27 -- Warning! Error messages can be generated during Gigi processing by direct
28 -- calls to error message routines, so it is essential that the processing
29 -- in this body be consistent with the requirements for the Gigi processing
30 -- environment, and that in particular, no disallowed table expansion is
31 -- allowed to occur.
33 with Casing; use Casing;
34 with Debug; use Debug;
35 with Err_Vars; use Err_Vars;
36 with Namet; use Namet;
37 with Opt; use Opt;
38 with Output; use Output;
39 with Sinput; use Sinput;
40 with Snames; use Snames;
41 with Targparm; use Targparm;
42 with Uintp; use Uintp;
44 package body Erroutc is
46 ---------------
47 -- Add_Class --
48 ---------------
50 procedure Add_Class is
51 begin
52 if Class_Flag then
53 Class_Flag := False;
54 Set_Msg_Char (''');
55 Get_Name_String (Name_Class);
56 Set_Casing (Identifier_Casing (Flag_Source), Mixed_Case);
57 Set_Msg_Name_Buffer;
58 end if;
59 end Add_Class;
61 ----------------------
62 -- Buffer_Ends_With --
63 ----------------------
65 function Buffer_Ends_With (S : String) return Boolean is
66 Len : constant Natural := S'Length;
67 begin
68 return
69 Msglen > Len
70 and then Msg_Buffer (Msglen - Len) = ' '
71 and then Msg_Buffer (Msglen - Len + 1 .. Msglen) = S;
72 end Buffer_Ends_With;
74 -------------------
75 -- Buffer_Remove --
76 -------------------
78 procedure Buffer_Remove (S : String) is
79 begin
80 if Buffer_Ends_With (S) then
81 Msglen := Msglen - S'Length;
82 end if;
83 end Buffer_Remove;
85 -----------------------------
86 -- Check_Duplicate_Message --
87 -----------------------------
89 procedure Check_Duplicate_Message (M1, M2 : Error_Msg_Id) is
90 L1, L2 : Error_Msg_Id;
91 N1, N2 : Error_Msg_Id;
93 procedure Delete_Msg (Delete, Keep : Error_Msg_Id);
94 -- Called to delete message Delete, keeping message Keep. Marks
95 -- all messages of Delete with deleted flag set to True, and also
96 -- makes sure that for the error messages that are retained the
97 -- preferred message is the one retained (we prefer the shorter
98 -- one in the case where one has an Instance tag). Note that we
99 -- always know that Keep has at least as many continuations as
100 -- Delete (since we always delete the shorter sequence).
102 ----------------
103 -- Delete_Msg --
104 ----------------
106 procedure Delete_Msg (Delete, Keep : Error_Msg_Id) is
107 D, K : Error_Msg_Id;
109 begin
110 D := Delete;
111 K := Keep;
113 loop
114 Errors.Table (D).Deleted := True;
116 -- Adjust error message count
118 if Errors.Table (D).Warn or Errors.Table (D).Style then
119 Warnings_Detected := Warnings_Detected - 1;
121 else
122 Total_Errors_Detected := Total_Errors_Detected - 1;
124 if Errors.Table (D).Serious then
125 Serious_Errors_Detected := Serious_Errors_Detected - 1;
126 end if;
127 end if;
129 -- Substitute shorter of the two error messages
131 if Errors.Table (K).Text'Length > Errors.Table (D).Text'Length then
132 Errors.Table (K).Text := Errors.Table (D).Text;
133 end if;
135 D := Errors.Table (D).Next;
136 K := Errors.Table (K).Next;
138 if D = No_Error_Msg or else not Errors.Table (D).Msg_Cont then
139 return;
140 end if;
141 end loop;
142 end Delete_Msg;
144 -- Start of processing for Check_Duplicate_Message
146 begin
147 -- Both messages must be non-continuation messages and not deleted
149 if Errors.Table (M1).Msg_Cont
150 or else Errors.Table (M2).Msg_Cont
151 or else Errors.Table (M1).Deleted
152 or else Errors.Table (M2).Deleted
153 then
154 return;
155 end if;
157 -- Definitely not equal if message text does not match
159 if not Same_Error (M1, M2) then
160 return;
161 end if;
163 -- Same text. See if all continuations are also identical
165 L1 := M1;
166 L2 := M2;
168 loop
169 N1 := Errors.Table (L1).Next;
170 N2 := Errors.Table (L2).Next;
172 -- If M1 continuations have run out, we delete M1, either the
173 -- messages have the same number of continuations, or M2 has
174 -- more and we prefer the one with more anyway.
176 if N1 = No_Error_Msg or else not Errors.Table (N1).Msg_Cont then
177 Delete_Msg (M1, M2);
178 return;
180 -- If M2 continuations have run out, we delete M2
182 elsif N2 = No_Error_Msg or else not Errors.Table (N2).Msg_Cont then
183 Delete_Msg (M2, M1);
184 return;
186 -- Otherwise see if continuations are the same, if not, keep both
187 -- sequences, a curious case, but better to keep everything!
189 elsif not Same_Error (N1, N2) then
190 return;
192 -- If continuations are the same, continue scan
194 else
195 L1 := N1;
196 L2 := N2;
197 end if;
198 end loop;
199 end Check_Duplicate_Message;
201 ------------------------
202 -- Compilation_Errors --
203 ------------------------
205 function Compilation_Errors return Boolean is
206 begin
207 return Total_Errors_Detected /= 0
208 or else (Warnings_Detected /= 0
209 and then Warning_Mode = Treat_As_Error);
210 end Compilation_Errors;
212 ------------------
213 -- Debug_Output --
214 ------------------
216 procedure Debug_Output (N : Node_Id) is
217 begin
218 if Debug_Flag_1 then
219 Write_Str ("*** following error message posted on node id = #");
220 Write_Int (Int (N));
221 Write_Str (" ***");
222 Write_Eol;
223 end if;
224 end Debug_Output;
226 ----------
227 -- dmsg --
228 ----------
230 procedure dmsg (Id : Error_Msg_Id) is
231 E : Error_Msg_Object renames Errors.Table (Id);
233 begin
234 w ("Dumping error message, Id = ", Int (Id));
235 w (" Text = ", E.Text.all);
236 w (" Next = ", Int (E.Next));
237 w (" Sfile = ", Int (E.Sfile));
239 Write_Str
240 (" Sptr = ");
241 Write_Location (E.Sptr);
242 Write_Eol;
244 Write_Str
245 (" Optr = ");
246 Write_Location (E.Optr);
247 Write_Eol;
249 w (" Line = ", Int (E.Line));
250 w (" Col = ", Int (E.Col));
251 w (" Warn = ", E.Warn);
252 w (" Style = ", E.Style);
253 w (" Serious = ", E.Serious);
254 w (" Uncond = ", E.Uncond);
255 w (" Msg_Cont = ", E.Msg_Cont);
256 w (" Deleted = ", E.Deleted);
258 Write_Eol;
259 end dmsg;
261 ------------------
262 -- Get_Location --
263 ------------------
265 function Get_Location (E : Error_Msg_Id) return Source_Ptr is
266 begin
267 return Errors.Table (E).Sptr;
268 end Get_Location;
270 ----------------
271 -- Get_Msg_Id --
272 ----------------
274 function Get_Msg_Id return Error_Msg_Id is
275 begin
276 return Cur_Msg;
277 end Get_Msg_Id;
279 -----------------------
280 -- Output_Error_Msgs --
281 -----------------------
283 procedure Output_Error_Msgs (E : in out Error_Msg_Id) is
284 P : Source_Ptr;
285 T : Error_Msg_Id;
286 S : Error_Msg_Id;
288 Flag_Num : Pos;
289 Mult_Flags : Boolean := False;
291 begin
292 S := E;
294 -- Skip deleted messages at start
296 if Errors.Table (S).Deleted then
297 Set_Next_Non_Deleted_Msg (S);
298 end if;
300 -- Figure out if we will place more than one error flag on this line
302 T := S;
303 while T /= No_Error_Msg
304 and then Errors.Table (T).Line = Errors.Table (E).Line
305 and then Errors.Table (T).Sfile = Errors.Table (E).Sfile
306 loop
307 if Errors.Table (T).Sptr > Errors.Table (E).Sptr then
308 Mult_Flags := True;
309 end if;
311 Set_Next_Non_Deleted_Msg (T);
312 end loop;
314 -- Output the error flags. The circuit here makes sure that the tab
315 -- characters in the original line are properly accounted for. The
316 -- eight blanks at the start are to match the line number.
318 if not Debug_Flag_2 then
319 Write_Str (" ");
320 P := Line_Start (Errors.Table (E).Sptr);
321 Flag_Num := 1;
323 -- Loop through error messages for this line to place flags
325 T := S;
326 while T /= No_Error_Msg
327 and then Errors.Table (T).Line = Errors.Table (E).Line
328 and then Errors.Table (T).Sfile = Errors.Table (E).Sfile
329 loop
330 -- Loop to output blanks till current flag position
332 while P < Errors.Table (T).Sptr loop
333 if Source_Text (Errors.Table (T).Sfile) (P) = ASCII.HT then
334 Write_Char (ASCII.HT);
335 else
336 Write_Char (' ');
337 end if;
339 P := P + 1;
340 end loop;
342 -- Output flag (unless already output, this happens if more
343 -- than one error message occurs at the same flag position).
345 if P = Errors.Table (T).Sptr then
346 if (Flag_Num = 1 and then not Mult_Flags)
347 or else Flag_Num > 9
348 then
349 Write_Char ('|');
350 else
351 Write_Char (Character'Val (Character'Pos ('0') + Flag_Num));
352 end if;
354 P := P + 1;
355 end if;
357 Set_Next_Non_Deleted_Msg (T);
358 Flag_Num := Flag_Num + 1;
359 end loop;
361 Write_Eol;
362 end if;
364 -- Now output the error messages
366 T := S;
367 while T /= No_Error_Msg
368 and then Errors.Table (T).Line = Errors.Table (E).Line
369 and then Errors.Table (T).Sfile = Errors.Table (E).Sfile
370 loop
371 Write_Str (" >>> ");
372 Output_Msg_Text (T);
374 if Debug_Flag_2 then
375 while Column < 74 loop
376 Write_Char (' ');
377 end loop;
379 Write_Str (" <<<");
380 end if;
382 Write_Eol;
383 Set_Next_Non_Deleted_Msg (T);
384 end loop;
386 E := T;
387 end Output_Error_Msgs;
389 ------------------------
390 -- Output_Line_Number --
391 ------------------------
393 procedure Output_Line_Number (L : Logical_Line_Number) is
394 D : Int; -- next digit
395 C : Character; -- next character
396 Z : Boolean; -- flag for zero suppress
397 N, M : Int; -- temporaries
399 begin
400 if L = No_Line_Number then
401 Write_Str (" ");
403 else
404 Z := False;
405 N := Int (L);
407 M := 100_000;
408 while M /= 0 loop
409 D := Int (N / M);
410 N := N rem M;
411 M := M / 10;
413 if D = 0 then
414 if Z then
415 C := '0';
416 else
417 C := ' ';
418 end if;
419 else
420 Z := True;
421 C := Character'Val (D + 48);
422 end if;
424 Write_Char (C);
425 end loop;
427 Write_Str (". ");
428 end if;
429 end Output_Line_Number;
431 ---------------------
432 -- Output_Msg_Text --
433 ---------------------
435 procedure Output_Msg_Text (E : Error_Msg_Id) is
436 Offs : constant Nat := Column - 1;
437 -- Offset to start of message, used for continuations
439 Max : Integer;
440 -- Maximum characters to output on next line
442 Length : Nat;
443 -- Maximum total length of lines
445 Txt : constant String_Ptr := Errors.Table (E).Text;
446 Len : constant Natural := Txt'Length;
447 Ptr : Natural;
448 Split : Natural;
449 Start : Natural;
451 begin
452 if Error_Msg_Line_Length = 0 then
453 Length := Nat'Last;
454 else
455 Length := Error_Msg_Line_Length;
456 end if;
458 Max := Integer (Length - Column + 1);
460 -- For warning message, add "warning: " unless msg starts with "info: "
462 if Errors.Table (E).Warn then
463 if Len < 6 or else Txt (Txt'First .. Txt'First + 5) /= "info: " then
464 Write_Str ("warning: ");
465 Max := Max - 9;
466 end if;
468 -- No prefix needed for style message, since "(style)" is there already
470 elsif Errors.Table (E).Style then
471 null;
473 -- All other cases, add "error: "
475 elsif Opt.Unique_Error_Tag then
476 Write_Str ("error: ");
477 Max := Max - 7;
478 end if;
480 -- Here we have to split the message up into multiple lines
482 Ptr := 1;
483 loop
484 -- Make sure we do not have ludicrously small line
486 Max := Integer'Max (Max, 20);
488 -- If remaining text fits, output it respecting LF and we are done
490 if Len - Ptr < Max then
491 for J in Ptr .. Len loop
492 if Txt (J) = ASCII.LF then
493 Write_Eol;
494 Write_Spaces (Offs);
495 else
496 Write_Char (Txt (J));
497 end if;
498 end loop;
500 return;
502 -- Line does not fit
504 else
505 Start := Ptr;
507 -- First scan forward looking for a hard end of line
509 for Scan in Ptr .. Ptr + Max - 1 loop
510 if Txt (Scan) = ASCII.LF then
511 Split := Scan - 1;
512 Ptr := Scan + 1;
513 goto Continue;
514 end if;
515 end loop;
517 -- Otherwise scan backwards looking for a space
519 for Scan in reverse Ptr .. Ptr + Max - 1 loop
520 if Txt (Scan) = ' ' then
521 Split := Scan - 1;
522 Ptr := Scan + 1;
523 goto Continue;
524 end if;
525 end loop;
527 -- If we fall through, no space, so split line arbitrarily
529 Split := Ptr + Max - 1;
530 Ptr := Split + 1;
531 end if;
533 <<Continue>>
534 if Start <= Split then
535 Write_Line (Txt (Start .. Split));
536 Write_Spaces (Offs);
537 end if;
539 Max := Integer (Length - Column + 1);
540 end loop;
541 end Output_Msg_Text;
543 --------------------
544 -- Purge_Messages --
545 --------------------
547 procedure Purge_Messages (From : Source_Ptr; To : Source_Ptr) is
548 E : Error_Msg_Id;
550 function To_Be_Purged (E : Error_Msg_Id) return Boolean;
551 -- Returns True for a message that is to be purged. Also adjusts
552 -- error counts appropriately.
554 ------------------
555 -- To_Be_Purged --
556 ------------------
558 function To_Be_Purged (E : Error_Msg_Id) return Boolean is
559 begin
560 if E /= No_Error_Msg
561 and then Errors.Table (E).Sptr > From
562 and then Errors.Table (E).Sptr < To
563 then
564 if Errors.Table (E).Warn or Errors.Table (E).Style then
565 Warnings_Detected := Warnings_Detected - 1;
567 else
568 Total_Errors_Detected := Total_Errors_Detected - 1;
570 if Errors.Table (E).Serious then
571 Serious_Errors_Detected := Serious_Errors_Detected - 1;
572 end if;
573 end if;
575 return True;
577 else
578 return False;
579 end if;
580 end To_Be_Purged;
582 -- Start of processing for Purge_Messages
584 begin
585 while To_Be_Purged (First_Error_Msg) loop
586 First_Error_Msg := Errors.Table (First_Error_Msg).Next;
587 end loop;
589 E := First_Error_Msg;
590 while E /= No_Error_Msg loop
591 while To_Be_Purged (Errors.Table (E).Next) loop
592 Errors.Table (E).Next :=
593 Errors.Table (Errors.Table (E).Next).Next;
594 end loop;
596 E := Errors.Table (E).Next;
597 end loop;
598 end Purge_Messages;
600 ----------------
601 -- Same_Error --
602 ----------------
604 function Same_Error (M1, M2 : Error_Msg_Id) return Boolean is
605 Msg1 : constant String_Ptr := Errors.Table (M1).Text;
606 Msg2 : constant String_Ptr := Errors.Table (M2).Text;
608 Msg2_Len : constant Integer := Msg2'Length;
609 Msg1_Len : constant Integer := Msg1'Length;
611 begin
612 return
613 Msg1.all = Msg2.all
614 or else
615 (Msg1_Len - 10 > Msg2_Len
616 and then
617 Msg2.all = Msg1.all (1 .. Msg2_Len)
618 and then
619 Msg1 (Msg2_Len + 1 .. Msg2_Len + 10) = ", instance")
620 or else
621 (Msg2_Len - 10 > Msg1_Len
622 and then
623 Msg1.all = Msg2.all (1 .. Msg1_Len)
624 and then
625 Msg2 (Msg1_Len + 1 .. Msg1_Len + 10) = ", instance");
626 end Same_Error;
628 -------------------
629 -- Set_Msg_Blank --
630 -------------------
632 procedure Set_Msg_Blank is
633 begin
634 if Msglen > 0
635 and then Msg_Buffer (Msglen) /= ' '
636 and then Msg_Buffer (Msglen) /= '('
637 and then Msg_Buffer (Msglen) /= '-'
638 and then not Manual_Quote_Mode
639 then
640 Set_Msg_Char (' ');
641 end if;
642 end Set_Msg_Blank;
644 -------------------------------
645 -- Set_Msg_Blank_Conditional --
646 -------------------------------
648 procedure Set_Msg_Blank_Conditional is
649 begin
650 if Msglen > 0
651 and then Msg_Buffer (Msglen) /= ' '
652 and then Msg_Buffer (Msglen) /= '('
653 and then Msg_Buffer (Msglen) /= '"'
654 and then not Manual_Quote_Mode
655 then
656 Set_Msg_Char (' ');
657 end if;
658 end Set_Msg_Blank_Conditional;
660 ------------------
661 -- Set_Msg_Char --
662 ------------------
664 procedure Set_Msg_Char (C : Character) is
665 begin
667 -- The check for message buffer overflow is needed to deal with cases
668 -- where insertions get too long (in particular a child unit name can
669 -- be very long).
671 if Msglen < Max_Msg_Length then
672 Msglen := Msglen + 1;
673 Msg_Buffer (Msglen) := C;
674 end if;
675 end Set_Msg_Char;
677 ---------------------------------
678 -- Set_Msg_Insertion_File_Name --
679 ---------------------------------
681 procedure Set_Msg_Insertion_File_Name is
682 begin
683 if Error_Msg_File_1 = No_File then
684 null;
686 elsif Error_Msg_File_1 = Error_File_Name then
687 Set_Msg_Blank;
688 Set_Msg_Str ("<error>");
690 else
691 Set_Msg_Blank;
692 Get_Name_String (Error_Msg_File_1);
693 Set_Msg_Quote;
694 Set_Msg_Name_Buffer;
695 Set_Msg_Quote;
696 end if;
698 -- The following assignments ensure that the second and third {
699 -- insertion characters will correspond to the Error_Msg_File_2 and
700 -- Error_Msg_File_3 values and We suppress possible validity checks in
701 -- case operating in -gnatVa mode, and Error_Msg_File_2 or
702 -- Error_Msg_File_3 is not needed and has not been set.
704 declare
705 pragma Suppress (Range_Check);
706 begin
707 Error_Msg_File_1 := Error_Msg_File_2;
708 Error_Msg_File_2 := Error_Msg_File_3;
709 end;
710 end Set_Msg_Insertion_File_Name;
712 -----------------------------------
713 -- Set_Msg_Insertion_Line_Number --
714 -----------------------------------
716 procedure Set_Msg_Insertion_Line_Number (Loc, Flag : Source_Ptr) is
717 Sindex_Loc : Source_File_Index;
718 Sindex_Flag : Source_File_Index;
720 begin
721 Set_Msg_Blank;
723 if Loc = No_Location then
724 Set_Msg_Str ("at unknown location");
726 elsif Loc = System_Location then
727 Set_Msg_Str ("in package System");
728 Set_Msg_Insertion_Run_Time_Name;
730 elsif Loc = Standard_Location then
731 Set_Msg_Str ("in package Standard");
733 elsif Loc = Standard_ASCII_Location then
734 Set_Msg_Str ("in package Standard.ASCII");
736 else
737 -- Add "at file-name:" if reference is to other than the source
738 -- file in which the error message is placed. Note that we check
739 -- full file names, rather than just the source indexes, to
740 -- deal with generic instantiations from the current file.
742 Sindex_Loc := Get_Source_File_Index (Loc);
743 Sindex_Flag := Get_Source_File_Index (Flag);
745 if Full_File_Name (Sindex_Loc) /= Full_File_Name (Sindex_Flag) then
746 Set_Msg_Str ("at ");
747 Get_Name_String
748 (Reference_Name (Get_Source_File_Index (Loc)));
749 Set_Msg_Name_Buffer;
750 Set_Msg_Char (':');
752 -- If in current file, add text "at line "
754 else
755 Set_Msg_Str ("at line ");
756 end if;
758 -- Output line number for reference
760 Set_Msg_Int (Int (Get_Logical_Line_Number (Loc)));
762 -- Deal with the instantiation case. We may have a reference to,
763 -- e.g. a type, that is declared within a generic template, and
764 -- what we are really referring to is the occurrence in an instance.
765 -- In this case, the line number of the instantiation is also of
766 -- interest, and we add a notation:
768 -- , instance at xxx
770 -- where xxx is a line number output using this same routine (and
771 -- the recursion can go further if the instantiation is itself in
772 -- a generic template).
774 -- The flag location passed to us in this situation is indeed the
775 -- line number within the template, but as described in Sinput.L
776 -- (file sinput-l.ads, section "Handling Generic Instantiations")
777 -- we can retrieve the location of the instantiation itself from
778 -- this flag location value.
780 -- Note: this processing is suppressed if Suppress_Instance_Location
781 -- is set True. This is used to prevent redundant annotations of the
782 -- location of the instantiation in the case where we are placing
783 -- the messages on the instantiation in any case.
785 if Instantiation (Sindex_Loc) /= No_Location
786 and then not Suppress_Instance_Location
787 then
788 Set_Msg_Str (", instance ");
789 Set_Msg_Insertion_Line_Number (Instantiation (Sindex_Loc), Flag);
790 end if;
791 end if;
792 end Set_Msg_Insertion_Line_Number;
794 ----------------------------
795 -- Set_Msg_Insertion_Name --
796 ----------------------------
798 procedure Set_Msg_Insertion_Name is
799 begin
800 if Error_Msg_Name_1 = No_Name then
801 null;
803 elsif Error_Msg_Name_1 = Error_Name then
804 Set_Msg_Blank;
805 Set_Msg_Str ("<error>");
807 else
808 Set_Msg_Blank_Conditional;
809 Get_Unqualified_Decoded_Name_String (Error_Msg_Name_1);
811 -- Remove %s or %b at end. These come from unit names. If the
812 -- caller wanted the (unit) or (body), then they would have used
813 -- the $ insertion character. Certainly no error message should
814 -- ever have %b or %s explicitly occurring.
816 if Name_Len > 2
817 and then Name_Buffer (Name_Len - 1) = '%'
818 and then (Name_Buffer (Name_Len) = 'b'
819 or else
820 Name_Buffer (Name_Len) = 's')
821 then
822 Name_Len := Name_Len - 2;
823 end if;
825 -- Remove upper case letter at end, again, we should not be getting
826 -- such names, and what we hope is that the remainder makes sense.
828 if Name_Len > 1
829 and then Name_Buffer (Name_Len) in 'A' .. 'Z'
830 then
831 Name_Len := Name_Len - 1;
832 end if;
834 -- If operator name or character literal name, just print it as is
835 -- Also print as is if it ends in a right paren (case of x'val(nnn))
837 if Name_Buffer (1) = '"'
838 or else Name_Buffer (1) = '''
839 or else Name_Buffer (Name_Len) = ')'
840 then
841 Set_Msg_Name_Buffer;
843 -- Else output with surrounding quotes in proper casing mode
845 else
846 Set_Casing (Identifier_Casing (Flag_Source), Mixed_Case);
847 Set_Msg_Quote;
848 Set_Msg_Name_Buffer;
849 Set_Msg_Quote;
850 end if;
851 end if;
853 -- The following assignments ensure that the second and third percent
854 -- insertion characters will correspond to the Error_Msg_Name_2 and
855 -- Error_Msg_Name_3 as required. We suppress possible validity checks in
856 -- case operating in -gnatVa mode, and Error_Msg_Name_1/2 is not needed
857 -- and has not been set.
859 declare
860 pragma Suppress (Range_Check);
861 begin
862 Error_Msg_Name_1 := Error_Msg_Name_2;
863 Error_Msg_Name_2 := Error_Msg_Name_3;
864 end;
865 end Set_Msg_Insertion_Name;
867 ------------------------------------
868 -- Set_Msg_Insertion_Name_Literal --
869 ------------------------------------
871 procedure Set_Msg_Insertion_Name_Literal is
872 begin
873 if Error_Msg_Name_1 = No_Name then
874 null;
876 elsif Error_Msg_Name_1 = Error_Name then
877 Set_Msg_Blank;
878 Set_Msg_Str ("<error>");
880 else
881 Set_Msg_Blank;
882 Get_Name_String (Error_Msg_Name_1);
883 Set_Msg_Quote;
884 Set_Msg_Name_Buffer;
885 Set_Msg_Quote;
886 end if;
888 -- The following assignments ensure that the second and third % or %%
889 -- insertion characters will correspond to the Error_Msg_Name_2 and
890 -- Error_Msg_Name_3 values and We suppress possible validity checks in
891 -- case operating in -gnatVa mode, and Error_Msg_Name_2 or
892 -- Error_Msg_Name_3 is not needed and has not been set.
894 declare
895 pragma Suppress (Range_Check);
896 begin
897 Error_Msg_Name_1 := Error_Msg_Name_2;
898 Error_Msg_Name_2 := Error_Msg_Name_3;
899 end;
900 end Set_Msg_Insertion_Name_Literal;
902 -------------------------------------
903 -- Set_Msg_Insertion_Reserved_Name --
904 -------------------------------------
906 procedure Set_Msg_Insertion_Reserved_Name is
907 begin
908 Set_Msg_Blank_Conditional;
909 Get_Name_String (Error_Msg_Name_1);
910 Set_Msg_Quote;
911 Set_Casing (Keyword_Casing (Flag_Source), All_Lower_Case);
912 Set_Msg_Name_Buffer;
913 Set_Msg_Quote;
914 end Set_Msg_Insertion_Reserved_Name;
916 -------------------------------------
917 -- Set_Msg_Insertion_Reserved_Word --
918 -------------------------------------
920 procedure Set_Msg_Insertion_Reserved_Word
921 (Text : String;
922 J : in out Integer)
924 begin
925 Set_Msg_Blank_Conditional;
926 Name_Len := 0;
928 while J <= Text'Last and then Text (J) in 'A' .. 'Z' loop
929 Name_Len := Name_Len + 1;
930 Name_Buffer (Name_Len) := Text (J);
931 J := J + 1;
932 end loop;
934 -- Here is where we make the special exception for RM
936 if Name_Len = 2 and then Name_Buffer (1 .. 2) = "RM" then
937 Set_Msg_Name_Buffer;
939 -- Not RM: case appropriately and add surrounding quotes
941 else
942 Set_Casing (Keyword_Casing (Flag_Source), All_Lower_Case);
943 Set_Msg_Quote;
944 Set_Msg_Name_Buffer;
945 Set_Msg_Quote;
946 end if;
947 end Set_Msg_Insertion_Reserved_Word;
949 -------------------------------------
950 -- Set_Msg_Insertion_Run_Time_Name --
951 -------------------------------------
953 procedure Set_Msg_Insertion_Run_Time_Name is
954 begin
955 if Targparm.Run_Time_Name_On_Target /= No_Name then
956 Set_Msg_Blank_Conditional;
957 Set_Msg_Char ('(');
958 Get_Name_String (Targparm.Run_Time_Name_On_Target);
959 Set_Casing (Mixed_Case);
960 Set_Msg_Str (Name_Buffer (1 .. Name_Len));
961 Set_Msg_Char (')');
962 end if;
963 end Set_Msg_Insertion_Run_Time_Name;
965 ----------------------------
966 -- Set_Msg_Insertion_Uint --
967 ----------------------------
969 procedure Set_Msg_Insertion_Uint is
970 begin
971 Set_Msg_Blank;
972 UI_Image (Error_Msg_Uint_1);
974 for J in 1 .. UI_Image_Length loop
975 Set_Msg_Char (UI_Image_Buffer (J));
976 end loop;
978 -- The following assignment ensures that a second caret insertion
979 -- character will correspond to the Error_Msg_Uint_2 parameter. We
980 -- suppress possible validity checks in case operating in -gnatVa mode,
981 -- and Error_Msg_Uint_2 is not needed and has not been set.
983 declare
984 pragma Suppress (Range_Check);
985 begin
986 Error_Msg_Uint_1 := Error_Msg_Uint_2;
987 end;
988 end Set_Msg_Insertion_Uint;
990 -----------------
991 -- Set_Msg_Int --
992 -----------------
994 procedure Set_Msg_Int (Line : Int) is
995 begin
996 if Line > 9 then
997 Set_Msg_Int (Line / 10);
998 end if;
1000 Set_Msg_Char (Character'Val (Character'Pos ('0') + (Line rem 10)));
1001 end Set_Msg_Int;
1003 -------------------------
1004 -- Set_Msg_Name_Buffer --
1005 -------------------------
1007 procedure Set_Msg_Name_Buffer is
1008 begin
1009 for J in 1 .. Name_Len loop
1010 Set_Msg_Char (Name_Buffer (J));
1011 end loop;
1012 end Set_Msg_Name_Buffer;
1014 -------------------
1015 -- Set_Msg_Quote --
1016 -------------------
1018 procedure Set_Msg_Quote is
1019 begin
1020 if not Manual_Quote_Mode then
1021 Set_Msg_Char ('"');
1022 end if;
1023 end Set_Msg_Quote;
1025 -----------------
1026 -- Set_Msg_Str --
1027 -----------------
1029 procedure Set_Msg_Str (Text : String) is
1030 begin
1031 for J in Text'Range loop
1032 Set_Msg_Char (Text (J));
1033 end loop;
1034 end Set_Msg_Str;
1036 ------------------------------
1037 -- Set_Next_Non_Deleted_Msg --
1038 ------------------------------
1040 procedure Set_Next_Non_Deleted_Msg (E : in out Error_Msg_Id) is
1041 begin
1042 if E = No_Error_Msg then
1043 return;
1045 else
1046 loop
1047 E := Errors.Table (E).Next;
1048 exit when E = No_Error_Msg or else not Errors.Table (E).Deleted;
1049 end loop;
1050 end if;
1051 end Set_Next_Non_Deleted_Msg;
1053 ------------------------------
1054 -- Set_Specific_Warning_Off --
1055 ------------------------------
1057 procedure Set_Specific_Warning_Off
1058 (Loc : Source_Ptr;
1059 Msg : String;
1060 Config : Boolean)
1062 begin
1063 Specific_Warnings.Append
1064 ((Start => Loc,
1065 Msg => new String'(Msg),
1066 Stop => Source_Last (Current_Source_File),
1067 Open => True,
1068 Used => False,
1069 Config => Config));
1070 end Set_Specific_Warning_Off;
1072 -----------------------------
1073 -- Set_Specific_Warning_On --
1074 -----------------------------
1076 procedure Set_Specific_Warning_On
1077 (Loc : Source_Ptr;
1078 Msg : String;
1079 Err : out Boolean)
1081 begin
1082 for J in 1 .. Specific_Warnings.Last loop
1083 declare
1084 SWE : Specific_Warning_Entry renames Specific_Warnings.Table (J);
1085 begin
1086 if Msg = SWE.Msg.all
1087 and then Loc > SWE.Start
1088 and then SWE.Open
1089 and then Get_Source_File_Index (SWE.Start) =
1090 Get_Source_File_Index (Loc)
1091 then
1092 SWE.Stop := Loc;
1093 SWE.Open := False;
1094 Err := False;
1096 -- If a config pragma is specifically cancelled, consider
1097 -- that it is no longer active as a configuration pragma.
1099 SWE.Config := False;
1100 return;
1101 end if;
1102 end;
1103 end loop;
1105 Err := True;
1106 end Set_Specific_Warning_On;
1108 ---------------------------
1109 -- Set_Warnings_Mode_Off --
1110 ---------------------------
1112 procedure Set_Warnings_Mode_Off (Loc : Source_Ptr) is
1113 begin
1114 -- Don't bother with entries from instantiation copies, since we
1115 -- will already have a copy in the template, which is what matters
1117 if Instantiation (Get_Source_File_Index (Loc)) /= No_Location then
1118 return;
1119 end if;
1121 -- If last entry in table already covers us, this is a redundant
1122 -- pragma Warnings (Off) and can be ignored. This also handles the
1123 -- case where all warnings are suppressed by command line switch.
1125 if Warnings.Last >= Warnings.First
1126 and then Warnings.Table (Warnings.Last).Start <= Loc
1127 and then Loc <= Warnings.Table (Warnings.Last).Stop
1128 then
1129 return;
1131 -- Otherwise establish a new entry, extending from the location of
1132 -- the pragma to the end of the current source file. This ending
1133 -- point will be adjusted by a subsequent pragma Warnings (On).
1135 else
1136 Warnings.Increment_Last;
1137 Warnings.Table (Warnings.Last).Start := Loc;
1138 Warnings.Table (Warnings.Last).Stop :=
1139 Source_Last (Current_Source_File);
1140 end if;
1141 end Set_Warnings_Mode_Off;
1143 --------------------------
1144 -- Set_Warnings_Mode_On --
1145 --------------------------
1147 procedure Set_Warnings_Mode_On (Loc : Source_Ptr) is
1148 begin
1149 -- Don't bother with entries from instantiation copies, since we
1150 -- will already have a copy in the template, which is what matters
1152 if Instantiation (Get_Source_File_Index (Loc)) /= No_Location then
1153 return;
1154 end if;
1156 -- Nothing to do unless command line switch to suppress all warnings
1157 -- is off, and the last entry in the warnings table covers this
1158 -- pragma Warnings (On), in which case adjust the end point.
1160 if (Warnings.Last >= Warnings.First
1161 and then Warnings.Table (Warnings.Last).Start <= Loc
1162 and then Loc <= Warnings.Table (Warnings.Last).Stop)
1163 and then Warning_Mode /= Suppress
1164 then
1165 Warnings.Table (Warnings.Last).Stop := Loc;
1166 end if;
1167 end Set_Warnings_Mode_On;
1169 ------------------------------------
1170 -- Test_Style_Warning_Serious_Msg --
1171 ------------------------------------
1173 procedure Test_Style_Warning_Serious_Msg (Msg : String) is
1174 begin
1175 if Msg (Msg'First) = '\' then
1176 return;
1177 end if;
1179 Is_Serious_Error := True;
1180 Is_Warning_Msg := False;
1182 Is_Style_Msg :=
1183 (Msg'Length > 7 and then Msg (Msg'First .. Msg'First + 6) = "(style)");
1185 if Is_Style_Msg then
1186 Is_Serious_Error := False;
1187 end if;
1189 for J in Msg'Range loop
1190 if Msg (J) = '?'
1191 and then (J = Msg'First or else Msg (J - 1) /= ''')
1192 then
1193 Is_Warning_Msg := True;
1195 elsif Msg (J) = '<'
1196 and then (J = Msg'First or else Msg (J - 1) /= ''')
1197 then
1198 Is_Warning_Msg := Error_Msg_Warn;
1200 elsif Msg (J) = '|'
1201 and then (J = Msg'First or else Msg (J - 1) /= ''')
1202 then
1203 Is_Serious_Error := False;
1204 end if;
1205 end loop;
1207 if Is_Warning_Msg or Is_Style_Msg then
1208 Is_Serious_Error := False;
1209 end if;
1210 end Test_Style_Warning_Serious_Msg;
1212 --------------------------------
1213 -- Validate_Specific_Warnings --
1214 --------------------------------
1216 procedure Validate_Specific_Warnings (Eproc : Error_Msg_Proc) is
1217 begin
1218 for J in Specific_Warnings.First .. Specific_Warnings.Last loop
1219 declare
1220 SWE : Specific_Warning_Entry renames Specific_Warnings.Table (J);
1221 begin
1222 if not SWE.Config then
1223 if SWE.Open then
1224 Eproc.all
1225 ("?pragma Warnings Off with no matching Warnings On",
1226 SWE.Start);
1227 elsif not SWE.Used then
1228 Eproc.all
1229 ("?no warning suppressed by this pragma", SWE.Start);
1230 end if;
1231 end if;
1232 end;
1233 end loop;
1234 end Validate_Specific_Warnings;
1236 -------------------------------------
1237 -- Warning_Specifically_Suppressed --
1238 -------------------------------------
1240 function Warning_Specifically_Suppressed
1241 (Loc : Source_Ptr;
1242 Msg : String_Ptr) return Boolean
1244 function Matches (S : String; P : String) return Boolean;
1245 -- Returns true if the String S patches the pattern P, which can contain
1246 -- wild card chars (*). The entire pattern must match the entire string.
1248 -------------
1249 -- Matches --
1250 -------------
1252 function Matches (S : String; P : String) return Boolean is
1253 Slast : constant Natural := S'Last;
1254 PLast : constant Natural := P'Last;
1256 SPtr : Natural := S'First;
1257 PPtr : Natural := P'First;
1259 begin
1260 -- Loop advancing through characters of string and pattern
1262 SPtr := S'First;
1263 PPtr := P'First;
1264 loop
1265 -- Return True if pattern is a single asterisk
1267 if PPtr = PLast and then P (PPtr) = '*' then
1268 return True;
1270 -- Return True if both pattern and string exhausted
1272 elsif PPtr > PLast and then SPtr > Slast then
1273 return True;
1275 -- Return False, if one exhausted and not the other
1277 elsif PPtr > PLast or else SPtr > Slast then
1278 return False;
1280 -- Case where pattern starts with asterisk
1282 elsif P (PPtr) = '*' then
1284 -- Try all possible starting positions in S for match with
1285 -- the remaining characters of the pattern. This is the
1286 -- recursive call that implements the scanner backup.
1288 for J in SPtr .. Slast loop
1289 if Matches (S (J .. Slast), P (PPtr + 1 .. PLast)) then
1290 return True;
1291 end if;
1292 end loop;
1294 return False;
1296 -- Dealt with end of string and *, advance if we have a match
1298 elsif S (SPtr) = P (PPtr) then
1299 SPtr := SPtr + 1;
1300 PPtr := PPtr + 1;
1302 -- If first characters do not match, that's decisive
1304 else
1305 return False;
1306 end if;
1307 end loop;
1308 end Matches;
1310 -- Start of processing for Warning_Specifically_Suppressed
1312 begin
1313 -- Loop through specific warning suppression entries
1315 for J in Specific_Warnings.First .. Specific_Warnings.Last loop
1316 declare
1317 SWE : Specific_Warning_Entry renames Specific_Warnings.Table (J);
1319 begin
1320 -- Pragma applies if it is a configuration pragma, or if the
1321 -- location is in range of a specific non-configuration pragma.
1323 if SWE.Config
1324 or else (SWE.Start <= Loc and then Loc <= SWE.Stop)
1325 then
1326 if Matches (Msg.all, SWE.Msg.all) then
1327 SWE.Used := True;
1328 return True;
1329 end if;
1330 end if;
1331 end;
1332 end loop;
1334 return False;
1335 end Warning_Specifically_Suppressed;
1337 -------------------------
1338 -- Warnings_Suppressed --
1339 -------------------------
1341 function Warnings_Suppressed (Loc : Source_Ptr) return Boolean is
1342 begin
1343 -- Loop through table of ON/OFF warnings
1345 for J in Warnings.First .. Warnings.Last loop
1346 if Warnings.Table (J).Start <= Loc
1347 and then Loc <= Warnings.Table (J).Stop
1348 then
1349 return True;
1350 end if;
1351 end loop;
1353 return False;
1354 end Warnings_Suppressed;
1356 end Erroutc;