LWG 3035. std::allocator's constructors should be constexpr
[official-gcc.git] / gcc / ada / lib.adb
bloba052b345c9e0aeb08f433444519363aed336c6c7
1 ------------------------------------------------------------------------------
2 -- --
3 -- GNAT COMPILER COMPONENTS --
4 -- --
5 -- L I B --
6 -- --
7 -- B o d y --
8 -- --
9 -- Copyright (C) 1992-2018, Free Software Foundation, Inc. --
10 -- --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. --
17 -- --
18 -- As a special exception under Section 7 of GPL version 3, you are granted --
19 -- additional permissions described in the GCC Runtime Library Exception, --
20 -- version 3.1, as published by the Free Software Foundation. --
21 -- --
22 -- You should have received a copy of the GNU General Public License and --
23 -- a copy of the GCC Runtime Library Exception along with this program; --
24 -- see the files COPYING3 and COPYING.RUNTIME respectively. If not, see --
25 -- <http://www.gnu.org/licenses/>. --
26 -- --
27 -- GNAT was originally developed by the GNAT team at New York University. --
28 -- Extensive contributions were provided by Ada Core Technologies Inc. --
29 -- --
30 ------------------------------------------------------------------------------
32 pragma Style_Checks (All_Checks);
33 -- Subprogram ordering not enforced in this unit
34 -- (because of some logical groupings).
36 with Atree; use Atree;
37 with Csets; use Csets;
38 with Einfo; use Einfo;
39 with Nlists; use Nlists;
40 with Opt; use Opt;
41 with Output; use Output;
42 with Sinfo; use Sinfo;
43 with Sinput; use Sinput;
44 with Stand; use Stand;
45 with Stringt; use Stringt;
46 with Tree_IO; use Tree_IO;
47 with Uname; use Uname;
48 with Widechar; use Widechar;
50 package body Lib is
52 Switch_Storing_Enabled : Boolean := True;
53 -- Controlled by Enable_Switch_Storing/Disable_Switch_Storing
55 -----------------------
56 -- Local Subprograms --
57 -----------------------
59 type SEU_Result is (
60 Yes_Before, -- S1 is in same extended unit as S2 and appears before it
61 Yes_Same, -- S1 is in same extended unit as S2, Slocs are the same
62 Yes_After, -- S1 is in same extended unit as S2, and appears after it
63 No); -- S2 is not in same extended unit as S2
65 function Check_Same_Extended_Unit
66 (S1 : Source_Ptr;
67 S2 : Source_Ptr) return SEU_Result;
68 -- Used by In_Same_Extended_Unit and Earlier_In_Extended_Unit. Returns
69 -- value as described above.
71 function Get_Code_Or_Source_Unit
72 (S : Source_Ptr;
73 Unwind_Instances : Boolean;
74 Unwind_Subunits : Boolean) return Unit_Number_Type;
75 -- Common processing for routines Get_Code_Unit, Get_Source_Unit, and
76 -- Get_Top_Level_Code_Unit. Unwind_Instances is True when the unit for the
77 -- top-level instantiation should be returned instead of the unit for the
78 -- template, in the case of an instantiation. Unwind_Subunits is True when
79 -- the corresponding top-level unit should be returned instead of a
80 -- subunit, in the case of a subunit.
82 --------------------------------------------
83 -- Access Functions for Unit Table Fields --
84 --------------------------------------------
86 function Cunit (U : Unit_Number_Type) return Node_Id is
87 begin
88 return Units.Table (U).Cunit;
89 end Cunit;
91 function Cunit_Entity (U : Unit_Number_Type) return Entity_Id is
92 begin
93 return Units.Table (U).Cunit_Entity;
94 end Cunit_Entity;
96 function Dependency_Num (U : Unit_Number_Type) return Nat is
97 begin
98 return Units.Table (U).Dependency_Num;
99 end Dependency_Num;
101 function Dynamic_Elab (U : Unit_Number_Type) return Boolean is
102 begin
103 return Units.Table (U).Dynamic_Elab;
104 end Dynamic_Elab;
106 function Error_Location (U : Unit_Number_Type) return Source_Ptr is
107 begin
108 return Units.Table (U).Error_Location;
109 end Error_Location;
111 function Expected_Unit (U : Unit_Number_Type) return Unit_Name_Type is
112 begin
113 return Units.Table (U).Expected_Unit;
114 end Expected_Unit;
116 function Fatal_Error (U : Unit_Number_Type) return Fatal_Type is
117 begin
118 return Units.Table (U).Fatal_Error;
119 end Fatal_Error;
121 function Generate_Code (U : Unit_Number_Type) return Boolean is
122 begin
123 return Units.Table (U).Generate_Code;
124 end Generate_Code;
126 function Has_RACW (U : Unit_Number_Type) return Boolean is
127 begin
128 return Units.Table (U).Has_RACW;
129 end Has_RACW;
131 function Is_Predefined_Renaming (U : Unit_Number_Type) return Boolean is
132 begin
133 return Units.Table (U).Is_Predefined_Renaming;
134 end Is_Predefined_Renaming;
136 function Is_Internal_Unit (U : Unit_Number_Type) return Boolean is
137 begin
138 return Units.Table (U).Is_Internal_Unit;
139 end Is_Internal_Unit;
141 function Is_Predefined_Unit (U : Unit_Number_Type) return Boolean is
142 begin
143 return Units.Table (U).Is_Predefined_Unit;
144 end Is_Predefined_Unit;
146 function Ident_String (U : Unit_Number_Type) return Node_Id is
147 begin
148 return Units.Table (U).Ident_String;
149 end Ident_String;
151 function Loading (U : Unit_Number_Type) return Boolean is
152 begin
153 return Units.Table (U).Loading;
154 end Loading;
156 function Main_CPU (U : Unit_Number_Type) return Int is
157 begin
158 return Units.Table (U).Main_CPU;
159 end Main_CPU;
161 function Main_Priority (U : Unit_Number_Type) return Int is
162 begin
163 return Units.Table (U).Main_Priority;
164 end Main_Priority;
166 function Munit_Index (U : Unit_Number_Type) return Nat is
167 begin
168 return Units.Table (U).Munit_Index;
169 end Munit_Index;
171 function No_Elab_Code_All (U : Unit_Number_Type) return Boolean is
172 begin
173 return Units.Table (U).No_Elab_Code_All;
174 end No_Elab_Code_All;
176 function OA_Setting (U : Unit_Number_Type) return Character is
177 begin
178 return Units.Table (U).OA_Setting;
179 end OA_Setting;
181 function Primary_Stack_Count (U : Unit_Number_Type) return Int is
182 begin
183 return Units.Table (U).Primary_Stack_Count;
184 end Primary_Stack_Count;
186 function Sec_Stack_Count (U : Unit_Number_Type) return Int is
187 begin
188 return Units.Table (U).Sec_Stack_Count;
189 end Sec_Stack_Count;
191 function Source_Index (U : Unit_Number_Type) return Source_File_Index is
192 begin
193 return Units.Table (U).Source_Index;
194 end Source_Index;
196 function Unit_File_Name (U : Unit_Number_Type) return File_Name_Type is
197 begin
198 return Units.Table (U).Unit_File_Name;
199 end Unit_File_Name;
201 function Unit_Name (U : Unit_Number_Type) return Unit_Name_Type is
202 begin
203 return Units.Table (U).Unit_Name;
204 end Unit_Name;
206 ------------------------------------------
207 -- Subprograms to Set Unit Table Fields --
208 ------------------------------------------
210 procedure Set_Cunit (U : Unit_Number_Type; N : Node_Id) is
211 begin
212 Units.Table (U).Cunit := N;
213 end Set_Cunit;
215 procedure Set_Cunit_Entity (U : Unit_Number_Type; E : Entity_Id) is
216 begin
217 Units.Table (U).Cunit_Entity := E;
218 Set_Is_Compilation_Unit (E);
219 end Set_Cunit_Entity;
221 procedure Set_Dynamic_Elab (U : Unit_Number_Type; B : Boolean := True) is
222 begin
223 Units.Table (U).Dynamic_Elab := B;
224 end Set_Dynamic_Elab;
226 procedure Set_Error_Location (U : Unit_Number_Type; W : Source_Ptr) is
227 begin
228 Units.Table (U).Error_Location := W;
229 end Set_Error_Location;
231 procedure Set_Fatal_Error (U : Unit_Number_Type; V : Fatal_Type) is
232 begin
233 Units.Table (U).Fatal_Error := V;
234 end Set_Fatal_Error;
236 procedure Set_Generate_Code (U : Unit_Number_Type; B : Boolean := True) is
237 begin
238 Units.Table (U).Generate_Code := B;
239 end Set_Generate_Code;
241 procedure Set_Has_RACW (U : Unit_Number_Type; B : Boolean := True) is
242 begin
243 Units.Table (U).Has_RACW := B;
244 end Set_Has_RACW;
246 procedure Set_Ident_String (U : Unit_Number_Type; N : Node_Id) is
247 begin
248 Units.Table (U).Ident_String := N;
249 end Set_Ident_String;
251 procedure Set_Loading (U : Unit_Number_Type; B : Boolean := True) is
252 begin
253 Units.Table (U).Loading := B;
254 end Set_Loading;
256 procedure Set_Main_CPU (U : Unit_Number_Type; P : Int) is
257 begin
258 Units.Table (U).Main_CPU := P;
259 end Set_Main_CPU;
261 procedure Set_Main_Priority (U : Unit_Number_Type; P : Int) is
262 begin
263 Units.Table (U).Main_Priority := P;
264 end Set_Main_Priority;
266 procedure Set_No_Elab_Code_All
267 (U : Unit_Number_Type;
268 B : Boolean := True)
270 begin
271 Units.Table (U).No_Elab_Code_All := B;
272 end Set_No_Elab_Code_All;
274 procedure Set_OA_Setting (U : Unit_Number_Type; C : Character) is
275 begin
276 Units.Table (U).OA_Setting := C;
277 end Set_OA_Setting;
279 procedure Set_Unit_Name (U : Unit_Number_Type; N : Unit_Name_Type) is
280 begin
281 Units.Table (U).Unit_Name := N;
282 end Set_Unit_Name;
284 ------------------------------
285 -- Check_Same_Extended_Unit --
286 ------------------------------
288 function Check_Same_Extended_Unit
289 (S1 : Source_Ptr;
290 S2 : Source_Ptr) return SEU_Result
292 Max_Iterations : constant Nat := Maximum_Instantiations * 2;
293 -- Limit to prevent a potential infinite loop
295 Counter : Nat := 0;
296 Depth1 : Nat;
297 Depth2 : Nat;
298 Inst1 : Source_Ptr;
299 Inst2 : Source_Ptr;
300 Sind1 : Source_File_Index;
301 Sind2 : Source_File_Index;
302 Sloc1 : Source_Ptr;
303 Sloc2 : Source_Ptr;
304 Unit1 : Node_Id;
305 Unit2 : Node_Id;
306 Unum1 : Unit_Number_Type;
307 Unum2 : Unit_Number_Type;
309 begin
310 if S1 = No_Location or else S2 = No_Location then
311 return No;
313 elsif S1 = Standard_Location then
314 if S2 = Standard_Location then
315 return Yes_Same;
316 else
317 return No;
318 end if;
320 elsif S2 = Standard_Location then
321 return No;
322 end if;
324 Sloc1 := S1;
325 Sloc2 := S2;
327 Unum1 := Get_Source_Unit (Sloc1);
328 Unum2 := Get_Source_Unit (Sloc2);
330 loop
331 -- Step 1: Check whether the two locations are in the same source
332 -- file.
334 Sind1 := Get_Source_File_Index (Sloc1);
335 Sind2 := Get_Source_File_Index (Sloc2);
337 if Sind1 = Sind2 then
338 if Sloc1 < Sloc2 then
339 return Yes_Before;
340 elsif Sloc1 > Sloc2 then
341 return Yes_After;
342 else
343 return Yes_Same;
344 end if;
345 end if;
347 -- Step 2: Check subunits. If a subunit is instantiated, follow the
348 -- instantiation chain rather than the stub chain.
350 Unit1 := Unit (Cunit (Unum1));
351 Unit2 := Unit (Cunit (Unum2));
352 Inst1 := Instantiation (Sind1);
353 Inst2 := Instantiation (Sind2);
355 if Nkind (Unit1) = N_Subunit
356 and then Present (Corresponding_Stub (Unit1))
357 and then Inst1 = No_Location
358 then
359 if Nkind (Unit2) = N_Subunit
360 and then Present (Corresponding_Stub (Unit2))
361 and then Inst2 = No_Location
362 then
363 -- Both locations refer to subunits which may have a common
364 -- ancestor. If they do, the deeper subunit must have a longer
365 -- unit name. Replace the deeper one with its corresponding
366 -- stub in order to find the nearest ancestor.
368 if Length_Of_Name (Unit_Name (Unum1)) <
369 Length_Of_Name (Unit_Name (Unum2))
370 then
371 Sloc2 := Sloc (Corresponding_Stub (Unit2));
372 Unum2 := Get_Source_Unit (Sloc2);
373 goto Continue;
375 else
376 Sloc1 := Sloc (Corresponding_Stub (Unit1));
377 Unum1 := Get_Source_Unit (Sloc1);
378 goto Continue;
379 end if;
381 -- Sloc1 in subunit, Sloc2 not
383 else
384 Sloc1 := Sloc (Corresponding_Stub (Unit1));
385 Unum1 := Get_Source_Unit (Sloc1);
386 goto Continue;
387 end if;
389 -- Sloc2 in subunit, Sloc1 not
391 elsif Nkind (Unit2) = N_Subunit
392 and then Present (Corresponding_Stub (Unit2))
393 and then Inst2 = No_Location
394 then
395 Sloc2 := Sloc (Corresponding_Stub (Unit2));
396 Unum2 := Get_Source_Unit (Sloc2);
397 goto Continue;
398 end if;
400 -- Step 3: Check instances. The two locations may yield a common
401 -- ancestor.
403 if Inst1 /= No_Location then
404 if Inst2 /= No_Location then
406 -- Both locations denote instantiations
408 Depth1 := Instantiation_Depth (Sloc1);
409 Depth2 := Instantiation_Depth (Sloc2);
411 if Depth1 < Depth2 then
412 Sloc2 := Inst2;
413 Unum2 := Get_Source_Unit (Sloc2);
414 goto Continue;
416 elsif Depth1 > Depth2 then
417 Sloc1 := Inst1;
418 Unum1 := Get_Source_Unit (Sloc1);
419 goto Continue;
421 else
422 Sloc1 := Inst1;
423 Sloc2 := Inst2;
424 Unum1 := Get_Source_Unit (Sloc1);
425 Unum2 := Get_Source_Unit (Sloc2);
426 goto Continue;
427 end if;
429 -- Sloc1 is an instantiation
431 else
432 Sloc1 := Inst1;
433 Unum1 := Get_Source_Unit (Sloc1);
434 goto Continue;
435 end if;
437 -- Sloc2 is an instantiation
439 elsif Inst2 /= No_Location then
440 Sloc2 := Inst2;
441 Unum2 := Get_Source_Unit (Sloc2);
442 goto Continue;
443 end if;
445 -- Step 4: One location in the spec, the other in the corresponding
446 -- body of the same unit. The location in the spec is considered
447 -- earlier.
449 if Nkind (Unit1) = N_Subprogram_Body
450 or else
451 Nkind (Unit1) = N_Package_Body
452 then
453 if Library_Unit (Cunit (Unum1)) = Cunit (Unum2) then
454 return Yes_After;
455 end if;
457 elsif Nkind (Unit2) = N_Subprogram_Body
458 or else
459 Nkind (Unit2) = N_Package_Body
460 then
461 if Library_Unit (Cunit (Unum2)) = Cunit (Unum1) then
462 return Yes_Before;
463 end if;
464 end if;
466 -- At this point it is certain that the two locations denote two
467 -- entirely separate units.
469 return No;
471 <<Continue>>
472 Counter := Counter + 1;
474 -- Prevent looping forever
476 if Counter > Max_Iterations then
478 -- ??? Not quite right, but return a value to be able to generate
479 -- SCIL files and hope for the best.
481 if CodePeer_Mode then
482 return No;
483 else
484 raise Program_Error;
485 end if;
486 end if;
487 end loop;
488 end Check_Same_Extended_Unit;
490 -------------------------------
491 -- Compilation_Switches_Last --
492 -------------------------------
494 function Compilation_Switches_Last return Nat is
495 begin
496 return Compilation_Switches.Last;
497 end Compilation_Switches_Last;
499 ---------------------------
500 -- Enable_Switch_Storing --
501 ---------------------------
503 procedure Enable_Switch_Storing is
504 begin
505 Switch_Storing_Enabled := True;
506 end Enable_Switch_Storing;
508 ----------------------------
509 -- Disable_Switch_Storing --
510 ----------------------------
512 procedure Disable_Switch_Storing is
513 begin
514 Switch_Storing_Enabled := False;
515 end Disable_Switch_Storing;
517 ------------------------------
518 -- Earlier_In_Extended_Unit --
519 ------------------------------
521 function Earlier_In_Extended_Unit
522 (S1 : Source_Ptr;
523 S2 : Source_Ptr) return Boolean
525 begin
526 return Check_Same_Extended_Unit (S1, S2) = Yes_Before;
527 end Earlier_In_Extended_Unit;
529 function Earlier_In_Extended_Unit
530 (N1 : Node_Or_Entity_Id;
531 N2 : Node_Or_Entity_Id) return Boolean
533 begin
534 return Earlier_In_Extended_Unit (Sloc (N1), Sloc (N2));
535 end Earlier_In_Extended_Unit;
537 -----------------------
538 -- Exact_Source_Name --
539 -----------------------
541 function Exact_Source_Name (Loc : Source_Ptr) return String is
542 U : constant Unit_Number_Type := Get_Source_Unit (Loc);
543 Buf : constant Source_Buffer_Ptr := Source_Text (Source_Index (U));
544 Orig : constant Source_Ptr := Original_Location (Loc);
545 P : Source_Ptr;
547 WC : Char_Code;
548 Err : Boolean;
549 pragma Warnings (Off, WC);
550 pragma Warnings (Off, Err);
552 begin
553 -- Entity is character literal
555 if Buf (Orig) = ''' then
556 return String (Buf (Orig .. Orig + 2));
558 -- Entity is operator symbol
560 elsif Buf (Orig) = '"' or else Buf (Orig) = '%' then
561 P := Orig;
563 loop
564 P := P + 1;
565 exit when Buf (P) = Buf (Orig);
566 end loop;
568 return String (Buf (Orig .. P));
570 -- Entity is identifier
572 else
573 P := Orig;
575 loop
576 if Is_Start_Of_Wide_Char (Buf, P) then
577 Scan_Wide (Buf, P, WC, Err);
578 elsif not Identifier_Char (Buf (P)) then
579 exit;
580 else
581 P := P + 1;
582 end if;
583 end loop;
585 -- Write out the identifier by copying the exact source characters
586 -- used in its declaration. Note that this means wide characters will
587 -- be in their original encoded form.
589 return String (Buf (Orig .. P - 1));
590 end if;
591 end Exact_Source_Name;
593 ----------------------------
594 -- Entity_Is_In_Main_Unit --
595 ----------------------------
597 function Entity_Is_In_Main_Unit (E : Entity_Id) return Boolean is
598 S : Entity_Id;
600 begin
601 S := Scope (E);
603 while S /= Standard_Standard loop
604 if S = Main_Unit_Entity then
605 return True;
606 elsif Ekind (S) = E_Package and then Is_Child_Unit (S) then
607 return False;
608 else
609 S := Scope (S);
610 end if;
611 end loop;
613 return False;
614 end Entity_Is_In_Main_Unit;
616 --------------------------
617 -- Generic_May_Lack_ALI --
618 --------------------------
620 function Generic_May_Lack_ALI (Unum : Unit_Number_Type) return Boolean is
621 begin
622 -- We allow internal generic units to be used without having a
623 -- corresponding ALI files to help bootstrapping with older compilers
624 -- that did not support generating ALIs for such generics. It is safe
625 -- to do so because the only thing the generated code would contain
626 -- is the elaboration boolean, and we are careful to elaborate all
627 -- predefined units first anyway.
629 return Is_Internal_Unit (Unum);
630 end Generic_May_Lack_ALI;
632 -----------------------------
633 -- Get_Code_Or_Source_Unit --
634 -----------------------------
636 function Get_Code_Or_Source_Unit
637 (S : Source_Ptr;
638 Unwind_Instances : Boolean;
639 Unwind_Subunits : Boolean) return Unit_Number_Type
641 begin
642 -- Search table unless we have No_Location, which can happen if the
643 -- relevant location has not been set yet. Happens for example when
644 -- we obtain Sloc (Cunit (Main_Unit)) before it is set.
646 if S /= No_Location then
647 declare
648 Source_File : Source_File_Index;
649 Source_Unit : Unit_Number_Type;
650 Unit_Node : Node_Id;
652 begin
653 Source_File := Get_Source_File_Index (S);
655 if Unwind_Instances then
656 while Template (Source_File) > No_Source_File loop
657 Source_File := Template (Source_File);
658 end loop;
659 end if;
661 Source_Unit := Unit (Source_File);
663 if Unwind_Subunits then
664 Unit_Node := Unit (Cunit (Source_Unit));
666 while Nkind (Unit_Node) = N_Subunit
667 and then Present (Corresponding_Stub (Unit_Node))
668 loop
669 Source_Unit :=
670 Get_Code_Or_Source_Unit
671 (Sloc (Corresponding_Stub (Unit_Node)),
672 Unwind_Instances => Unwind_Instances,
673 Unwind_Subunits => Unwind_Subunits);
674 Unit_Node := Unit (Cunit (Source_Unit));
675 end loop;
676 end if;
678 if Source_Unit /= No_Unit then
679 return Source_Unit;
680 end if;
681 end;
682 end if;
684 -- If S was No_Location, or was not in the table, we must be in the main
685 -- source unit (and the value has not been placed in the table yet),
686 -- or in one of the configuration pragma files.
688 return Main_Unit;
689 end Get_Code_Or_Source_Unit;
691 -------------------
692 -- Get_Code_Unit --
693 -------------------
695 function Get_Code_Unit (S : Source_Ptr) return Unit_Number_Type is
696 begin
697 return
698 Get_Code_Or_Source_Unit
699 (Top_Level_Location (S),
700 Unwind_Instances => False,
701 Unwind_Subunits => False);
702 end Get_Code_Unit;
704 function Get_Code_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type is
705 begin
706 return Get_Code_Unit (Sloc (N));
707 end Get_Code_Unit;
709 ----------------------------
710 -- Get_Compilation_Switch --
711 ----------------------------
713 function Get_Compilation_Switch (N : Pos) return String_Ptr is
714 begin
715 if N <= Compilation_Switches.Last then
716 return Compilation_Switches.Table (N);
717 else
718 return null;
719 end if;
720 end Get_Compilation_Switch;
722 ----------------------------------
723 -- Get_Cunit_Entity_Unit_Number --
724 ----------------------------------
726 function Get_Cunit_Entity_Unit_Number
727 (E : Entity_Id) return Unit_Number_Type
729 begin
730 for U in Units.First .. Units.Last loop
731 if Cunit_Entity (U) = E then
732 return U;
733 end if;
734 end loop;
736 -- If not in the table, must be the main source unit, and we just
737 -- have not got it put into the table yet.
739 return Main_Unit;
740 end Get_Cunit_Entity_Unit_Number;
742 ---------------------------
743 -- Get_Cunit_Unit_Number --
744 ---------------------------
746 function Get_Cunit_Unit_Number (N : Node_Id) return Unit_Number_Type is
747 begin
748 for U in Units.First .. Units.Last loop
749 if Cunit (U) = N then
750 return U;
751 end if;
752 end loop;
754 -- If not in the table, must be a spec created for a main unit that is a
755 -- child subprogram body which we have not inserted into the table yet.
757 if N = Library_Unit (Cunit (Main_Unit)) then
758 return Main_Unit;
760 -- If it is anything else, something is seriously wrong, and we really
761 -- don't want to proceed, even if assertions are off, so we explicitly
762 -- raise an exception in this case to terminate compilation.
764 else
765 raise Program_Error;
766 end if;
767 end Get_Cunit_Unit_Number;
769 ---------------------
770 -- Get_Source_Unit --
771 ---------------------
773 function Get_Source_Unit (S : Source_Ptr) return Unit_Number_Type is
774 begin
775 return
776 Get_Code_Or_Source_Unit
777 (S => S,
778 Unwind_Instances => True,
779 Unwind_Subunits => False);
780 end Get_Source_Unit;
782 function Get_Source_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type is
783 begin
784 return Get_Source_Unit (Sloc (N));
785 end Get_Source_Unit;
787 -----------------------------
788 -- Get_Top_Level_Code_Unit --
789 -----------------------------
791 function Get_Top_Level_Code_Unit (S : Source_Ptr) return Unit_Number_Type is
792 begin
793 return
794 Get_Code_Or_Source_Unit
795 (Top_Level_Location (S),
796 Unwind_Instances => False,
797 Unwind_Subunits => True);
798 end Get_Top_Level_Code_Unit;
800 function Get_Top_Level_Code_Unit
801 (N : Node_Or_Entity_Id) return Unit_Number_Type is
802 begin
803 return Get_Top_Level_Code_Unit (Sloc (N));
804 end Get_Top_Level_Code_Unit;
806 --------------------------------
807 -- In_Extended_Main_Code_Unit --
808 --------------------------------
810 function In_Extended_Main_Code_Unit
811 (N : Node_Or_Entity_Id) return Boolean
813 begin
814 if Sloc (N) = Standard_Location then
815 return False;
817 elsif Sloc (N) = No_Location then
818 return False;
820 -- Special case Itypes to test the Sloc of the associated node. The
821 -- reason we do this is for possible calls from gigi after -gnatD
822 -- processing is complete in sprint. This processing updates the
823 -- sloc fields of all nodes in the tree, but itypes are not in the
824 -- tree so their slocs do not get updated.
826 elsif Nkind (N) = N_Defining_Identifier
827 and then Is_Itype (N)
828 then
829 return In_Extended_Main_Code_Unit (Associated_Node_For_Itype (N));
831 -- Otherwise see if we are in the main unit
833 elsif Get_Code_Unit (Sloc (N)) = Get_Code_Unit (Cunit (Main_Unit)) then
834 return True;
836 -- Node may be in spec (or subunit etc) of main unit
838 else
839 return In_Same_Extended_Unit (N, Cunit (Main_Unit));
840 end if;
841 end In_Extended_Main_Code_Unit;
843 function In_Extended_Main_Code_Unit (Loc : Source_Ptr) return Boolean is
844 begin
845 if Loc = Standard_Location then
846 return False;
848 elsif Loc = No_Location then
849 return False;
851 -- Otherwise see if we are in the main unit
853 elsif Get_Code_Unit (Loc) = Get_Code_Unit (Cunit (Main_Unit)) then
854 return True;
856 -- Location may be in spec (or subunit etc) of main unit
858 else
859 return In_Same_Extended_Unit (Loc, Sloc (Cunit (Main_Unit)));
860 end if;
861 end In_Extended_Main_Code_Unit;
863 ----------------------------------
864 -- In_Extended_Main_Source_Unit --
865 ----------------------------------
867 function In_Extended_Main_Source_Unit
868 (N : Node_Or_Entity_Id) return Boolean
870 Nloc : constant Source_Ptr := Sloc (N);
871 Mloc : constant Source_Ptr := Sloc (Cunit (Main_Unit));
873 begin
874 -- If parsing, then use the global flag to indicate result
876 if Compiler_State = Parsing then
877 return Parsing_Main_Extended_Source;
879 -- Special value cases
881 elsif Nloc = Standard_Location then
882 return False;
884 elsif Nloc = No_Location then
885 return False;
887 -- Special case Itypes to test the Sloc of the associated node. The
888 -- reason we do this is for possible calls from gigi after -gnatD
889 -- processing is complete in sprint. This processing updates the
890 -- sloc fields of all nodes in the tree, but itypes are not in the
891 -- tree so their slocs do not get updated.
893 elsif Nkind (N) = N_Defining_Identifier
894 and then Is_Itype (N)
895 then
896 return In_Extended_Main_Source_Unit (Associated_Node_For_Itype (N));
898 -- Otherwise compare original locations to see if in same unit
900 else
901 return
902 In_Same_Extended_Unit
903 (Original_Location (Nloc), Original_Location (Mloc));
904 end if;
905 end In_Extended_Main_Source_Unit;
907 function In_Extended_Main_Source_Unit
908 (Loc : Source_Ptr) return Boolean
910 Mloc : constant Source_Ptr := Sloc (Cunit (Main_Unit));
912 begin
913 -- If parsing, then use the global flag to indicate result
915 if Compiler_State = Parsing then
916 return Parsing_Main_Extended_Source;
918 -- Special value cases
920 elsif Loc = Standard_Location then
921 return False;
923 elsif Loc = No_Location then
924 return False;
926 -- Otherwise compare original locations to see if in same unit
928 else
929 return
930 In_Same_Extended_Unit
931 (Original_Location (Loc), Original_Location (Mloc));
932 end if;
933 end In_Extended_Main_Source_Unit;
935 ----------------------
936 -- In_Internal_Unit --
937 ----------------------
939 function In_Internal_Unit (N : Node_Or_Entity_Id) return Boolean is
940 begin
941 return In_Internal_Unit (Sloc (N));
942 end In_Internal_Unit;
944 function In_Internal_Unit (S : Source_Ptr) return Boolean is
945 Unit : constant Unit_Number_Type := Get_Source_Unit (S);
946 begin
947 return Is_Internal_Unit (Unit);
948 end In_Internal_Unit;
950 ----------------------------
951 -- In_Predefined_Renaming --
952 ----------------------------
954 function In_Predefined_Renaming (N : Node_Or_Entity_Id) return Boolean is
955 begin
956 return In_Predefined_Renaming (Sloc (N));
957 end In_Predefined_Renaming;
959 function In_Predefined_Renaming (S : Source_Ptr) return Boolean is
960 Unit : constant Unit_Number_Type := Get_Source_Unit (S);
961 begin
962 return Is_Predefined_Renaming (Unit);
963 end In_Predefined_Renaming;
965 ------------------------
966 -- In_Predefined_Unit --
967 ------------------------
969 function In_Predefined_Unit (N : Node_Or_Entity_Id) return Boolean is
970 begin
971 return In_Predefined_Unit (Sloc (N));
972 end In_Predefined_Unit;
974 function In_Predefined_Unit (S : Source_Ptr) return Boolean is
975 Unit : constant Unit_Number_Type := Get_Source_Unit (S);
976 begin
977 return Is_Predefined_Unit (Unit);
978 end In_Predefined_Unit;
980 -----------------------
981 -- In_Same_Code_Unit --
982 -----------------------
984 function In_Same_Code_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean is
985 S1 : constant Source_Ptr := Sloc (N1);
986 S2 : constant Source_Ptr := Sloc (N2);
988 begin
989 if S1 = No_Location or else S2 = No_Location then
990 return False;
992 elsif S1 = Standard_Location then
993 return S2 = Standard_Location;
995 elsif S2 = Standard_Location then
996 return False;
997 end if;
999 return Get_Code_Unit (N1) = Get_Code_Unit (N2);
1000 end In_Same_Code_Unit;
1002 ---------------------------
1003 -- In_Same_Extended_Unit --
1004 ---------------------------
1006 function In_Same_Extended_Unit
1007 (N1, N2 : Node_Or_Entity_Id) return Boolean
1009 begin
1010 return Check_Same_Extended_Unit (Sloc (N1), Sloc (N2)) /= No;
1011 end In_Same_Extended_Unit;
1013 function In_Same_Extended_Unit (S1, S2 : Source_Ptr) return Boolean is
1014 begin
1015 return Check_Same_Extended_Unit (S1, S2) /= No;
1016 end In_Same_Extended_Unit;
1018 -------------------------
1019 -- In_Same_Source_Unit --
1020 -------------------------
1022 function In_Same_Source_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean is
1023 S1 : constant Source_Ptr := Sloc (N1);
1024 S2 : constant Source_Ptr := Sloc (N2);
1026 begin
1027 if S1 = No_Location or else S2 = No_Location then
1028 return False;
1030 elsif S1 = Standard_Location then
1031 return S2 = Standard_Location;
1033 elsif S2 = Standard_Location then
1034 return False;
1035 end if;
1037 return Get_Source_Unit (N1) = Get_Source_Unit (N2);
1038 end In_Same_Source_Unit;
1040 -----------------------------------
1041 -- Increment_Primary_Stack_Count --
1042 -----------------------------------
1044 procedure Increment_Primary_Stack_Count (Increment : Int) is
1045 PSC : Int renames Units.Table (Current_Sem_Unit).Primary_Stack_Count;
1046 begin
1047 PSC := PSC + Increment;
1048 end Increment_Primary_Stack_Count;
1050 -------------------------------
1051 -- Increment_Sec_Stack_Count --
1052 -------------------------------
1054 procedure Increment_Sec_Stack_Count (Increment : Int) is
1055 SSC : Int renames Units.Table (Current_Sem_Unit).Sec_Stack_Count;
1056 begin
1057 SSC := SSC + Increment;
1058 end Increment_Sec_Stack_Count;
1060 -----------------------------
1061 -- Increment_Serial_Number --
1062 -----------------------------
1064 function Increment_Serial_Number return Nat is
1065 TSN : Int renames Units.Table (Current_Sem_Unit).Serial_Number;
1066 begin
1067 TSN := TSN + 1;
1068 return TSN;
1069 end Increment_Serial_Number;
1071 ----------------
1072 -- Initialize --
1073 ----------------
1075 procedure Initialize is
1076 begin
1077 Linker_Option_Lines.Init;
1078 Notes.Init;
1079 Load_Stack.Init;
1080 Units.Init;
1081 Compilation_Switches.Init;
1082 end Initialize;
1084 ---------------
1085 -- Is_Loaded --
1086 ---------------
1088 function Is_Loaded (Uname : Unit_Name_Type) return Boolean is
1089 begin
1090 for Unum in Units.First .. Units.Last loop
1091 if Uname = Unit_Name (Unum) then
1092 return True;
1093 end if;
1094 end loop;
1096 return False;
1097 end Is_Loaded;
1099 ---------------
1100 -- Last_Unit --
1101 ---------------
1103 function Last_Unit return Unit_Number_Type is
1104 begin
1105 return Units.Last;
1106 end Last_Unit;
1108 ----------
1109 -- List --
1110 ----------
1112 procedure List (File_Names_Only : Boolean := False) is separate;
1114 ----------
1115 -- Lock --
1116 ----------
1118 procedure Lock is
1119 begin
1120 Linker_Option_Lines.Release;
1121 Linker_Option_Lines.Locked := True;
1122 Load_Stack.Release;
1123 Load_Stack.Locked := True;
1124 Units.Release;
1125 Units.Locked := True;
1126 end Lock;
1128 ---------------
1129 -- Num_Units --
1130 ---------------
1132 function Num_Units return Nat is
1133 begin
1134 return Int (Units.Last) - Int (Main_Unit) + 1;
1135 end Num_Units;
1137 -----------------
1138 -- Remove_Unit --
1139 -----------------
1141 procedure Remove_Unit (U : Unit_Number_Type) is
1142 begin
1143 if U = Units.Last then
1144 Units.Decrement_Last;
1145 end if;
1146 end Remove_Unit;
1148 ----------------------------------
1149 -- Replace_Linker_Option_String --
1150 ----------------------------------
1152 procedure Replace_Linker_Option_String
1153 (S : String_Id; Match_String : String)
1155 begin
1156 if Match_String'Length > 0 then
1157 for J in 1 .. Linker_Option_Lines.Last loop
1158 String_To_Name_Buffer (Linker_Option_Lines.Table (J).Option);
1160 if Match_String = Name_Buffer (1 .. Match_String'Length) then
1161 Linker_Option_Lines.Table (J).Option := S;
1162 return;
1163 end if;
1164 end loop;
1165 end if;
1167 Store_Linker_Option_String (S);
1168 end Replace_Linker_Option_String;
1170 ----------
1171 -- Sort --
1172 ----------
1174 procedure Sort (Tbl : in out Unit_Ref_Table) is separate;
1176 ------------------------------
1177 -- Store_Compilation_Switch --
1178 ------------------------------
1180 procedure Store_Compilation_Switch (Switch : String) is
1181 begin
1182 if Switch_Storing_Enabled then
1183 Compilation_Switches.Increment_Last;
1184 Compilation_Switches.Table (Compilation_Switches.Last) :=
1185 new String'(Switch);
1187 -- Fix up --RTS flag which has been transformed by the gcc driver
1188 -- into -fRTS
1190 if Switch'Last >= Switch'First + 4
1191 and then Switch (Switch'First .. Switch'First + 4) = "-fRTS"
1192 then
1193 Compilation_Switches.Table
1194 (Compilation_Switches.Last) (Switch'First + 1) := '-';
1195 end if;
1196 end if;
1197 end Store_Compilation_Switch;
1199 --------------------------------
1200 -- Store_Linker_Option_String --
1201 --------------------------------
1203 procedure Store_Linker_Option_String (S : String_Id) is
1204 begin
1205 Linker_Option_Lines.Append ((Option => S, Unit => Current_Sem_Unit));
1206 end Store_Linker_Option_String;
1208 ----------------
1209 -- Store_Note --
1210 ----------------
1212 procedure Store_Note (N : Node_Id) is
1213 Sfile : constant Source_File_Index := Get_Source_File_Index (Sloc (N));
1215 begin
1216 -- Notes for a generic are emitted when processing the template, never
1217 -- in instances.
1219 if In_Extended_Main_Code_Unit (N)
1220 and then Instance (Sfile) = No_Instance_Id
1221 then
1222 Notes.Append (N);
1223 end if;
1224 end Store_Note;
1226 -------------------------------
1227 -- Synchronize_Serial_Number --
1228 -------------------------------
1230 procedure Synchronize_Serial_Number is
1231 TSN : Int renames Units.Table (Current_Sem_Unit).Serial_Number;
1232 begin
1233 TSN := TSN + 1;
1234 end Synchronize_Serial_Number;
1236 ---------------
1237 -- Tree_Read --
1238 ---------------
1240 procedure Tree_Read is
1241 N : Nat;
1242 S : String_Ptr;
1244 begin
1245 Units.Tree_Read;
1247 -- Read Compilation_Switches table. First release the memory occupied
1248 -- by the previously loaded switches.
1250 for J in Compilation_Switches.First .. Compilation_Switches.Last loop
1251 Free (Compilation_Switches.Table (J));
1252 end loop;
1254 Tree_Read_Int (N);
1255 Compilation_Switches.Set_Last (N);
1257 for J in 1 .. N loop
1258 Tree_Read_Str (S);
1259 Compilation_Switches.Table (J) := S;
1260 end loop;
1261 end Tree_Read;
1263 ----------------
1264 -- Tree_Write --
1265 ----------------
1267 procedure Tree_Write is
1268 begin
1269 Units.Tree_Write;
1271 -- Write Compilation_Switches table
1273 Tree_Write_Int (Compilation_Switches.Last);
1275 for J in 1 .. Compilation_Switches.Last loop
1276 Tree_Write_Str (Compilation_Switches.Table (J));
1277 end loop;
1278 end Tree_Write;
1280 ------------
1281 -- Unlock --
1282 ------------
1284 procedure Unlock is
1285 begin
1286 Linker_Option_Lines.Locked := False;
1287 Load_Stack.Locked := False;
1288 Units.Locked := False;
1289 end Unlock;
1291 -----------------
1292 -- Version_Get --
1293 -----------------
1295 function Version_Get (U : Unit_Number_Type) return Word_Hex_String is
1296 begin
1297 return Get_Hex_String (Units.Table (U).Version);
1298 end Version_Get;
1300 ------------------------
1301 -- Version_Referenced --
1302 ------------------------
1304 procedure Version_Referenced (S : String_Id) is
1305 begin
1306 Version_Ref.Append (S);
1307 end Version_Referenced;
1309 ---------------------
1310 -- Write_Unit_Info --
1311 ---------------------
1313 procedure Write_Unit_Info
1314 (Unit_Num : Unit_Number_Type;
1315 Item : Node_Id;
1316 Prefix : String := "";
1317 Withs : Boolean := False)
1319 begin
1320 Write_Str (Prefix);
1321 Write_Unit_Name (Unit_Name (Unit_Num));
1322 Write_Str (", unit ");
1323 Write_Int (Int (Unit_Num));
1324 Write_Str (", ");
1325 Write_Int (Int (Item));
1326 Write_Str ("=");
1327 Write_Str (Node_Kind'Image (Nkind (Item)));
1329 if Is_Rewrite_Substitution (Item) then
1330 Write_Str (", orig = ");
1331 Write_Int (Int (Original_Node (Item)));
1332 Write_Str ("=");
1333 Write_Str (Node_Kind'Image (Nkind (Original_Node (Item))));
1334 end if;
1336 Write_Eol;
1338 -- Skip the rest if we're not supposed to print the withs
1340 if not Withs then
1341 return;
1342 end if;
1344 declare
1345 Context_Item : Node_Id;
1347 begin
1348 Context_Item := First (Context_Items (Cunit (Unit_Num)));
1349 while Present (Context_Item)
1350 and then (Nkind (Context_Item) /= N_With_Clause
1351 or else Limited_Present (Context_Item))
1352 loop
1353 Context_Item := Next (Context_Item);
1354 end loop;
1356 if Present (Context_Item) then
1357 Indent;
1358 Write_Line ("withs:");
1359 Indent;
1361 while Present (Context_Item) loop
1362 if Nkind (Context_Item) = N_With_Clause
1363 and then not Limited_Present (Context_Item)
1364 then
1365 pragma Assert (Present (Library_Unit (Context_Item)));
1366 Write_Unit_Name
1367 (Unit_Name
1368 (Get_Cunit_Unit_Number (Library_Unit (Context_Item))));
1370 if Implicit_With (Context_Item) then
1371 Write_Str (" -- implicit");
1372 end if;
1374 Write_Eol;
1375 end if;
1377 Context_Item := Next (Context_Item);
1378 end loop;
1380 Outdent;
1381 Write_Line ("end withs");
1382 Outdent;
1383 end if;
1384 end;
1385 end Write_Unit_Info;
1387 end Lib;