1 '\" te
2 .\" Copyright (c) 2001 Sun Microsystems, Inc. All Rights Reserved
3 .\" The contents of this file are subject to the terms of the Common Development and Distribution License (the "License").  You may not use this file except in compliance with the License.
4 .\" You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing.  See the License for the specific language governing permissions and limitations under the License.
5 .\" When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE.  If applicable, add the following below this CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
6 .TH TH_DEFINE 8 "April 9, 2016"
7 .SH NAME
8 th_define \- create fault injection test harness error specifications
9 .SH SYNOPSIS
10 .LP
11 .nf
12 \fBth_define\fR [\fB-n\fR \fIname\fR \fB-i\fR \fIinstance\fR| \fB-P\fR \fIpath\fR] [\fB-a\fR \fIacc_types\fR]
13      [\fB-r\fR \fIreg_number\fR] [\fB-l\fR \fIoffset\fR [\fIlength\fR]]
14      [\fB-c\fR \fIcount\fR [\fIfailcount\fR]] [\fB-o\fR \fIoperator\fR [\fIoperand\fR]]
15      [\fB-f\fR \fIacc_chk\fR] [\fB-w\fR \fImax_wait_period\fR [\fIreport_interval\fR]]
16 .fi
18 .LP
19 .nf
20 \fBor\fR
21 .fi
23 .LP
24 .nf
25 \fBth_define\fR [\fB-n\fR \fIname\fR \fB-i\fR \fIinstance\fR| \fB-P\fR \fIpath\fR]
26      [\fB-a\fR log [\fIacc_types\fR] [\fB-r\fR \fIreg_number\fR] [\fB-l\fR \fIoffset\fR [\fIlength\fR]]]
27      [\fB-c\fR \fIcount\fR [\fIfailcount\fR]] [\fB-s\fR \fIcollect_time\fR] [\fB-p\fR \fIpolicy\fR]
28      [\fB-x\fR \fIflags\fR] [\fB-C\fR \fIcomment_string\fR]
29      [\fB-e\fR \fIfixup_script\fR [\fIargs\fR]]
30 .fi
32 .LP
33 .nf
34 \fBor\fR
35 .fi
37 .LP
38 .nf
39 \fBth_define\fR [\fB-h\fR]
40 .fi
42 .SH DESCRIPTION
43 .LP
44 The \fBth_define\fR utility provides an interface to the \fBbus_ops\fR fault
45 injection \fBbofi\fR device driver for defining error injection specifications
46 (referred to as errdefs). An errdef corresponds to a specification of how to
47 corrupt a device driver's accesses to its hardware. The command line arguments
48 determine the precise nature of the fault to be injected. If the supplied
49 arguments define a consistent errdef, the \fBth_define\fR process will store
50 the errdef with the \fBbofi\fR driver and suspend itself until the criteria
51 given by the errdef become satisfied (in practice, this will occur when the
52 access counts go to zero).
53 .sp
54 .LP
55 You use the \fBth_manage\fR(8) command with the \fBstart\fR option to activate
56 the resulting errdef. The effect of \fBth_manage\fR with the \fBstart\fR option
57 is that the \fBbofi\fR driver acts upon the errdef by matching the number of
58 hardware accesses\(emspecified in \fIcount\fR, that are of the type specified
59 in \fIacc_types\fR, made by instance number \fIinstance\fR\(emof the driver
60 whose name is \fIname\fR, (or by the driver instance specified by \fIpath\fR)
61 to the register set (or DMA handle) specified by \fIreg_number\fR, that lie
62 within the range \fIoffset\fR to \fIoffset\fR +\fI length\fR from the beginning
63 of the register set or DMA handle. It then applies \fIoperator\fR and
64 \fIoperand\fR to the next \fIfailcount\fR matching accesses.
65 .sp
66 .LP
67 If \fIacc_types\fR includes \fBlog\fR, \fBth_define\fR runs in automatic test
68 script generation mode, and a set of test scripts (written in the Korn shell)
69 is created and placed in a sub-directory of the current directory with the name
70 \fB\fI<driver>\fR\&.test.\fI<id>\fR\fR (for example, \fBglm.test.978177106\fR).
71 A separate, executable script is generated for each access handle that matches
72 the logging criteria. The log of accesses is placed at the top of each script
73 as a record of the session. If the current directory is not writable, file
74 output is written to standard output. The base name of each test file is the
75 driver name, and the extension is a number that discriminates between different
76 access handles. A control script (with the same name as the created test
77 directory) is generated that will run all the test scripts sequentially.
78 .sp
79 .LP
80 Executing the scripts will install, and then activate, the resulting error
81 definitions. Error definitions are activated sequentially and the driver
82 instance under test is taken offline and brought back online before each test
83 (refer to the \fB-e\fR option for more information). By default, logging
84 applies to all \fBPIO\fR accesses, all interrupts, and all DMA accesses to and
85 from areas mapped for both reading and writing. You can constrain logging by
86 specifying additional \fIacc_types\fR, \fIreg_number\fR, \fIoffset\fR and
87 \fIlength\fR. Logging will continue for \fIcount\fR matching accesses, with an
88 optional time limit of \fIcollect_time\fR seconds.
89 .sp
90 .LP
91 Either the \fB-n\fR or \fB-P\fR option must be provided. The other options are
92 optional. If an option (other than \fB-a\fR) is specified multiple times, only
93 the final value for the option is used. If an option is not specified, its
94 associated value is set to an appropriate default, which will provide maximal
95 error coverage as described below.
96 .SH OPTIONS
97 .LP
98 The following options are available:
99 .sp
100 .ne 2
102 \fB\fB-n\fR \fIname\fR \fR
104 .sp .6
105 .RS 4n
106 Specify the name of the driver to test. (String)
110 .ne 2
112 \fB\fB-i\fR\fI instance\fR \fR
114 .sp .6
115 .RS 4n
116 Test only the specified driver instance (-1 matches all instances of driver).
117 (Numeric)
121 .ne 2
123 \fB\fB-P\fR\fI path\fR \fR
125 .sp .6
126 .RS 4n
127 Specify the full device path of the driver to test. (String)
131 .ne 2
133 \fB\fB-r\fR \fIreg_number\fR \fR
135 .sp .6
136 .RS 4n
137 Test only the given register set or DMA handle (-1 matches all register sets
138 and DMA handles). (Numeric)
142 .ne 2
144 \fB\fB-a\fR\fI acc_types\fR \fR
146 .sp .6
147 .RS 4n
148 Only the specified access types will be matched. Valid values for the
149 \fIacc_types\fR argument are \fBlog\fR, \fBpio\fR, \fBpio_r\fR, \fBpio_w\fR,
150 \fBdma\fR, \fBdma_r\fR, \fBdma_w\fR and \fBintr\fR. Multiple access types,
151 separated by spaces, can be specified. The default is to match all hardware
152 accesses.
154 If \fIacc_types\fR is set to \fBlog\fR, logging will match all \fBPIO\fR
155 accesses, interrupts and DMA accesses to and from areas mapped for both reading
156 and writing. \fBlog\fR can be combined with other \fIacc_types\fR, in which
157 case the matching condition for logging will be restricted to the specified
158 additional \fIacc_types\fR. Note that \fBdma_r\fR will match only DMA handles
159 mapped for reading only; \fBdma_w\fR will match only DMA handles mapped for
160 writing only; \fBdma\fR will match only DMA handles mapped for both reading and
161 writing.
165 .ne 2
167 \fB\fB-l\fR \fIoffset \fR\fB[\fR\fIlength\fR\fB]\fR\fR
169 .sp .6
170 .RS 4n
171 Constrain the range of qualifying accesses. The \fIoffset\fR and \fIlength\fR
172 arguments indicate that any access of the type specified with the \fB-a\fR
173 option, to the register set or DMA handle specified with the \fB-r\fR option,
174 lie at least \fIoffset\fR bytes into the register set or DMA handle and at most
175 \fIoffset\fR + \fIlength\fR bytes into it. The default for \fIoffset\fR is 0.
176 The default for \fIlength\fR is the maximum value that can be placed in an
177 \fBoffset_t\fR C data type (see \fBtypes.h\fR). Negative values are converted
178 into unsigned quantities. Thus, \fB\fR\fBth_define\fR\fB \fR\fB-l\fR 0 \fB-1\fR
179 is maximal.
183 .ne 2
185 \fB\fB-c\fR \fIcount\fR\fB[\fR\fIfailcount\fR\fB]\fR \fR
187 .sp .6
188 .RS 4n
189 Wait for \fIcount\fR number of matching accesses, then apply an operator and
190 operand (see the \fB-o\fR option) to the next \fIfailcount\fR number of
191 matching accesses. If the access type (see the \fB-a\fR option) includes
192 logging, the number of logged accesses is given by \fIcount\fR +
193 \fIfailcount\fR - 1. The -1 is required because the last access coincides with
194 the first faulting access.
196 Note that access logging may be combined with error injection if
197 \fIfailcount\fR and \fIoperator\fR are nonzero and if the access type includes
198 logging and any of the other access types (\fBpio\fR, \fBdma\fR and \fBintr\fR)
199 See the description of access types in the definition of the \fB-a\fR option,
200 above.
202 When the \fIcount\fR and \fIfailcount\fR fields reach zero, the status of the
203 errdef is reported to standard output. When all active errdefs created by the
204 \fBth_define\fR process complete, the process exits. If \fIacc_types\fR
205 includes \fBlog\fR, \fIcount\fR determines how many accesses to log. If
206 \fIcount\fR is not specified, a default value is used. If \fIfailcount\fR is
207 set in this mode, it will simply increase the number of accesses logged by a
208 further \fIfailcount\fR - 1.
212 .ne 2
214 \fB\fB-o\fR\fI operator \fR\fB[\fR\fIoperand\fR\fB]\fR \fR
216 .sp .6
217 .RS 4n
218 For qualifying PIO read and write accesses, the value read from or written to
219 the hardware is corrupted according to the value of \fIoperator\fR:
221 .ne 2
223 \fB\fBEQ\fR\fR
225 .RS 7n
226 \fIoperand\fR is returned to the driver.
230 .ne 2
232 \fB\fBOR\fR\fR
234 .RS 7n
235 \fIoperand\fR is bitwise ORed with the real value.
239 .ne 2
241 \fB\fBAND\fR\fR
243 .RS 7n
244 \fIoperand\fR is bitwise ANDed with the real value.
248 .ne 2
250 \fB\fBXOR\fR\fR
252 .RS 7n
253 \fIoperand\fR is bitwise XORed with the real value.
256 For PIO write accesses, the following operator is allowed:
258 .ne 2
260 \fB\fBNO\fR\fR
262 .RS 6n
263 Simply ignore the driver's attempt to write to the hardware.
266 Note that a driver performs PIO via the \fBddi_get\fIX\fR()\fR,
267 \fBddi_put\fIX\fR()\fR, \fBddi_rep_get\fIX\fR()\fR and
268 \fBddi_rep_put\fIX\fR()\fR routines (where \fIX\fR is 8, 16, 32 or 64).
269 Accesses made using \fBddi_get\fIX\fR()\fR and \fBddi_put\fIX\fR()\fR are
270 treated as a single access, whereas an access made using the
271 \fBddi_rep_*\fR(9F) routines are broken down into their respective number of
272 accesses, as given by the \fIrepcount\fR parameter to these DDI calls. If the
273 access is performed via a DMA handle, \fIoperator\fR and \fIvalue\fR are
274 applied to every access that comprises the DMA request. If interference with
275 interrupts has been requested then the operator may take any of the following
276 values:
278 .ne 2
280 \fB\fBDELAY\fR\fR
282 .RS 9n
283 After \fIcount\fR accesses (see the \fB-c\fR option), delay delivery of the
284 next \fIfailcount\fR number of interrupts for \fIoperand\fR number of
285 microseconds.
289 .ne 2
291 \fB\fBLOSE\fR\fR
293 .RS 9n
294 After \fIcount\fR number of interrupts, fail to deliver the next
295 \fIfailcount\fR number of real interrupts to the driver.
299 .ne 2
301 \fB\fBEXTRA\fR\fR
303 .RS 9n
304 After \fIcount\fR number of interrupts, start delivering \fIoperand\fR number
305 of extra interrupts for the next \fIfailcount\fR number of real interrupts.
308 The default value for \fIoperand\fR and \fIoperator\fR is to corrupt the data
309 access by flipping each bit (XOR with -1).
313 .ne 2
315 \fB\fB-f\fR \fIacc_chk\fR\fR
317 .sp .6
318 .RS 4n
319 If the \fIacc_chk\fR parameter is set to 1 or \fBpio\fR, then the driver's
320 calls to \fBddi_check_acc_handle\fR(9F) return \fBDDI_FAILURE\fR when the
321 access count goes to 1. If the \fIacc_chk\fR parameter is set to 2 or
322 \fBdma\fR, then the driver's calls to \fBddi_check_dma_handle\fR(9F) return
323 \fBDDI_FAILURE\fR when the access count goes to 1.
327 .ne 2
329 \fB\fB-w\fR \fImax_wait_period\fR\fB [\fR\fIreport_interval\fR\fB]\fR \fR
331 .sp .6
332 .RS 4n
333 Constrain the period for which an error definition will remain active. The
334 option applies only to non-logging errdefs. If an error definition remains
335 active for \fImax_wait_period\fR seconds, the test will be aborted. If
336 \fIreport_interval\fR is set to a nonzero value, the current status of the
337 error definition is reported to standard output every \fIreport_interval\fR
338 seconds. The default value is zero. The status of the errdef is reported in
339 parsable format (eight fields, each separated by a colon (\fB:\fR) character,
340 the last of which is a string enclosed by double quotes and the remaining seven
341 fields are integers):
343 \fIft\fR:\fImt\fR:\fIac\fR:\fIfc\fR:\fIchk\fR:\fIec\fR:\fIs\fR:\fI"message"\fR
344 which are defined as follows:
346 .ne 2
348 \fB\fIft\fR\fR
350 .RS 13n
351 The UTC time when the fault was injected.
355 .ne 2
357 \fB\fImt\fR\fR
359 .RS 13n
360 The UTC time when the driver reported the fault.
364 .ne 2
366 \fB\fIac\fR\fR
368 .RS 13n
369 The number of remaining non-faulting accesses.
373 .ne 2
375 \fB\fIfc\fR\fR
377 .RS 13n
378 The number of remaining faulting accesses.
382 .ne 2
384 \fB\fIchk\fR\fR
386 .RS 13n
387 The value of the \fIacc_chk\fR field of the errdef.
391 .ne 2
393 \fB\fIec\fR\fR
395 .RS 13n
396 The number of fault reports issued by the driver against this errdef (\fImt\fR
397 holds the time of the initial report).
401 .ne 2
403 \fB\fIs\fR\fR
405 .RS 13n
406 The severity level reported by the driver.
410 .ne 2
412 \fB\fI"message"\fR\fR
414 .RS 13n
415 Textual reason why the driver has reported a fault.
421 .ne 2
423 \fB\fB-h\fR\fR
425 .sp .6
426 .RS 4n
427 Display the command usage string.
431 .ne 2
433 \fB\fB-s\fR \fIcollect_time\fR \fR
435 .sp .6
436 .RS 4n
437 If \fIacc_types\fR is given with the \fB-a\fR option and includes \fBlog\fR,
438 the errdef will log accesses for \fIcollect_time\fR seconds (the default is to
439 log until the log becomes full). Note that, if the errdef specification matches
440 multiple driver handles, multiple logging errdefs are registered with the
441 \fBbofi\fR driver and logging terminates when all logs become full or when
442 \fIcollect_time\fR expires or when the associated errdefs are cleared. The
443 current state of the log can be checked with the \fBth_manage\fR(8) command,
444 using the \fBbroadcast\fR parameter. A log can be terminated by running
445 \fBth_manage\fR(8) with the \fBclear_errdefs\fR option or by sending a
446 \fBSIGALRM\fR signal to the \fBth_define\fR process. See \fBalarm\fR(2) for the
447 semantics of \fBSIGALRM\fR.
451 .ne 2
453 \fB\fB-p\fR \fIpolicy\fR\fR
455 .sp .6
456 .RS 4n
457 Applicable when the \fIacc_types\fR option includes \fBlog\fR. The parameter
458 modifies the policy used for converting from logged accesses to errdefs. All
459 policies are inclusive:
460 .RS +4
462 .ie t \(bu
463 .el o
464 Use \fBrare\fR to bias error definitions toward rare accesses (default).
466 .RS +4
468 .ie t \(bu
469 .el o
470 Use \fBoperator\fR to produce a separate error definition for each operator
471 type (default).
473 .RS +4
475 .ie t \(bu
476 .el o
477 Use \fBcommon\fR to bias error definitions toward common accesses.
479 .RS +4
481 .ie t \(bu
482 .el o
483 Use \fBmedian\fR to bias error definitions toward median accesses.
485 .RS +4
487 .ie t \(bu
488 .el o
489 Use \fBmaximal\fR to produce multiple error definitions for duplicate accesses.
491 .RS +4
493 .ie t \(bu
494 .el o
495 Use \fBunbiased\fR to create unbiased error definitions.
497 .RS +4
499 .ie t \(bu
500 .el o
501 Use \fBonebyte\fR, \fBtwobyte\fR, \fBfourbyte\fR, or \fBeightbyte\fR to select
502 errdefs corresponding to 1, 2, 4 or 8 byte accesses (if chosen, the
503 \fB-x\fR\fBr\fR option is enforced in order to ensure that \fBddi_rep_*()\fR
504 calls are decomposed into \fBmultiple single accesses\fR).
506 .RS +4
508 .ie t \(bu
509 .el o
510 Use \fBmultibyte\fR to create error definitions for multibyte accesses
511 performed using \fBddi_rep_get*()\fR and \fBddi_rep_put*()\fR.
513 Policies can be combined by adding together these options. See the NOTES
514 section for further information.
518 .ne 2
520 \fB\fB-x\fR \fIflags\fR\fR
522 .sp .6
523 .RS 4n
524 Applicable when the \fIacc_types\fR option includes \fBlog\fR. The \fIflags\fR
525 parameter modifies the way in which the \fBbofi\fR driver logs accesses. It is
526 specified as a string containing any combination of the following letters:
528 .ne 2
530 \fB\fBw\fR\fR
532 .RS 5n
533 Continuous logging (that is, the log will wrap when full).
537 .ne 2
539 \fB\fBt\fR\fR
541 .RS 5n
542 Timestamp each log entry (access times are in seconds).
546 .ne 2
548 \fB\fBr\fR\fR
550 .RS 5n
551 Log repeated I/O as individual accesses (for example, a \fBddi_rep_get16\fR(9F)
552 call which has a repcount of \fIN\fR is logged \fIN\fR times with each
553 transaction logged as size 2 bytes. Without this option, the default logging
554 behavior is to log this access once only, with a transaction size of twice the
555 \fIrepcount\fR).
561 .ne 2
563 \fB\fB-C\fR \fIcomment_string\fR\fR
565 .sp .6
566 .RS 4n
567 Applicable when the \fIacc_types\fR option includes \fBlog\fR. It provides a
568 comment string to be placed in any generated test scripts. The string must be
569 enclosed in double quotes.
573 .ne 2
575 \fB\fB-e\fR \fIfixup_script\fR \fB[\fR\fIargs\fR\fB]\fR \fR
577 .sp .6
578 .RS 4n
579 Applicable when the \fIacc_types\fR option includes \fBlog\fR. The output of a
580 logging errdefs is to generate a test script for each driver access handle. Use
581 this option to embed a command in the resulting script before the errors are
582 injected. The generated test scripts will take an instance offline and bring it
583 back online before injecting errors in order to bring the instance into a known
584 fault-free state. The executable \fIfixup_script\fR will be called twice with
585 the set of optional \fIargs\fR\(em once just before the instance is taken
586 offline and again after the instance has been brought online. The following
587 variables are passed into the environment of the called executable:
589 .ne 2
591 \fB\fBDRIVER_PATH\fR\fR
593 .RS 22n
594 Identifies the device path of the instance.
598 .ne 2
600 \fB\fBDRIVER_INSTANCE\fR\fR
602 .RS 22n
603 Identifies the instance number of the device.
607 .ne 2
609 \fB\fBDRIVER_UNCONFIGURE\fR\fR
611 .RS 22n
612 Has the value 1 when the instance is about to be taken offline.
616 .ne 2
618 \fB\fBDRIVER_CONFIGURE\fR\fR
620 .RS 22n
621 Has the value 1 when the instance has just been brought online.
624 Typically, the executable ensures that the device under test is in a suitable
625 state to be taken offline (unconfigured) or in a suitable state for error
626 injection (for example configured, error free and servicing a workload). A
627 minimal script for a network driver could be:
629 .in +2
631 #!/bin/ksh
633 driver=xyznetdriver
634 ifnum=$driver$DRIVER_INSTANCE
636 if [[ $DRIVER_CONFIGURE = 1 ]]; then
637         ifconfig $ifnum plumb
638         ifconfig $ifnum ...
639         ifworkload start $ifnum
640 elif [[ $DRIVER_UNCONFIGURE = 1 ]]; then
641         ifworkload stop $ifnum
642         ifconfig $ifnum down
643         ifconfig $ifnum unplumb
645 exit $?
647 .in -2
650 The \fB-e\fR option must be the last option on the command line.
655 If the \fB-a\fR \fBlog\fR option is selected but the \fB-e\fR option is not
656 given, a default script is used. This script repeatedly attempts to detach and
657 then re-attach the device instance under test.
658 .SH EXAMPLES
659 .SS "Examples of Error Definitions"
661 \fBth_define -n foo -i 1 -a log\fR
664 Logs all accesses to all handles used by instance 1 of the \fBfoo\fR driver
665 while running the default workload (attaching and detaching the instance). Then
666 generates a set of test scripts to inject appropriate errdefs while running
667 that default workload.
670 \fBth_define -n foo -i 1 -a log pio\fR
673 Logs PIO accesses to each PIO handle used by instance 1 of the \fBfoo\fR driver
674 while running the default workload (attaching and detaching the instance). Then
675 generates a set of test scripts to inject appropriate errdefs while running
676 that default workload.
679 \fBth_define -n foo -i 1 -p onebyte median -e fixup arg -now\fR
682 Logs all accesses to all handles used by instance 1 of the \fBfoo\fR driver
683 while running the workload defined in the fixup script \fBfixup\fR with
684 arguments \fBarg\fR and \fB-now\fR. Then generates a set of test scripts to
685 inject appropriate errdefs while running that workload. The resulting error
686 definitions are requested to focus upon single byte accesses to locations that
687 are accessed a \fBmedian\fR number of times with respect to frequency of access
688 to I/O addresses.
691 \fBth_define -n se -l 0x20 1 -a pio_r -o OR 0x4 -c 10 1000\fR
694 Simulates a stuck serial chip command by forcing 1000 consecutive read accesses
695 made by any instance of the \fBse\fR driver to its command status register,
696 thereby returning status busy.
699 \fBth_define -n foo -i 3 -r 1 -a pio_r -c 0 1 -f 1 -o OR 0x100\fR
702 Causes 0x100 to be ORed into the next physical I/O read access from any
703 register in register set 1 of instance 3 of the \fBfoo\fR driver. Subsequent
704 calls in the driver to \fBddi_check_acc_handle()\fR return \fBDDI_FAILURE\fR.
707 \fBth_define -n foo -i 3 -r 1 -a pio_r -c 0 1 -o OR 0x0\fR
710 Causes 0x0 to be ORed into the next physical I/O read access from any register
711 in register set 1 of instance 3 of the \fBfoo\fR driver. This is of course a
712 no-op.
715 \fBth_define -n foo -i 3 -r 1 -l 0x8100 1 -a pio_r -c 0 10 -o EQ 0x70003\fR
718 Causes the next ten next physical I/O reads from the register at offset 0x8100
719 in register set 1 of instance 3 of the \fBfoo\fR driver to return 0x70003.
722 \fBth_define -n foo -i 3 -r 1 -l 0x8100 1 -a pio_w -c 100 3 -o AND
723 0xffffffffffffefff\fR
726 The next 100 physical I/O writes to the register at offset 0x8100 in register
727 set 1 of instance 3 of the \fBfoo\fR driver take place as normal. However, on
728 each of the three subsequent accesses, the 0x1000 bit will be cleared.
731 \fBth_define -n foo -i 3 -r 1 -l 0x8100 0x10 -a pio_r -c 0 1 -f 1 -o XOR 7\fR
734 Causes the bottom three bits to have their values toggled for the next physical
735 I/O read access to registers with offsets in the range 0x8100 to 0x8110 in
736 register set 1 of instance 3 of the \fBfoo\fR driver. Subsequent calls in the
737 driver to \fBddi_check_acc_handle()\fR return \fBDDI_FAILURE\fR.
740 \fBth_define -n foo -i 3 -a pio_w -c 0 1 -o NO 0\fR
743 Prevents the next physical I/O write access to any register in any register set
744 of instance 3 of the \fBfoo\fR driver from going out on the bus.
747 \fBth_define -n foo -i 3 -l 0 8192 -a dma_r -c 0 1 -o OR 7\fR
750 Causes 0x7 to be ORed into each \fBlong long\fR in the first 8192 bytes of the
751 next DMA read, using any DMA handle for instance 3 of the \fBfoo\fR driver.
754 \fBth_define -n foo -i 3 -r 2 -l 0 8 -a dma_r -c 0 1 -o OR
755 0x7070707070707070\fR
758 Causes 0x70 to be ORed into each byte of the first \fBlong long\fR of the next
759 DMA read, using the DMA handle with sequential allocation number 2 for instance
760 3 of the \fBfoo\fR driver.
763 \fBth_define -n foo -i 3 -l 256 256 -a dma_w -c 0 1 -f 2 -o OR 7\fR
766 Causes 0x7 to be ORed into each \fBlong long\fR in the range from offset 256 to
767 offset 512 of the next DMA write, using any DMA handle for instance 3 of the
768 \fBfoo\fR driver. Subsequent calls in the driver to
769 \fBddi_check_dma_handle()\fR return \fBDDI_FAILURE\fR.
772 \fBth_define -n foo -i 3 -r 0 -l 0 8 -a dma_w -c 100 3 -o AND
773 0xffffffffffffefff\fR
776 The next 100 DMA writes using the DMA handle with sequential allocation number
777 0 for instance 3 of the \fBfoo\fR driver take place as normal. However, on each
778 of the three subsequent accesses, the 0x1000 bit will be cleared in the first
779 \fBlong long\fR of the transfer.
782 \fBth_define -n foo -i 3 -a intr -c 0 6 -o LOSE 0\fR
785 Causes the next six interrupts for instance 3 of the \fBfoo\fR driver to be
786 lost.
789 \fBth_define -n foo -i 3 -a intr -c 30 1 -o EXTRA 10\fR
792 When the thirty-first subsequent interrupt for instance 3 of the \fBfoo\fR
793 driver occurs, a further ten interrupts are also generated.
796 \fBth_define -n foo -i 3 -a intr -c 0 1 -o DELAY 1024\fR
799 Causes the next interrupt for instance 3 of the \fBfoo\fR driver to be delayed
800 by 1024 microseconds.
801 .SH NOTES
803 The policy option in the \fBth_define\fR \fB-p\fR syntax determines how a set
804 of logged accesses will be converted into the set of error definitions. Each
805 logged access will be matched against the chosen policies to determine whether
806 an error definition should be created based on the access.
809 Any number of policy options can be combined to modify the generated error
810 definitions.
811 .SS "Bytewise Policies"
813 These select particular I/O transfer sizes. Specifying a byte policy will
814 exclude other byte policies that have not been chosen. If none of the byte type
815 policies is selected, all transfer sizes are treated equally. Otherwise, only
816 those specified transfer sizes will be selected.
818 .ne 2
820 \fB\fBonebyte\fR\fR
822 .RS 13n
823 Create errdefs for one byte accesses (\fBddi_get8()\fR)
827 .ne 2
829 \fB\fBtwobyte\fR\fR
831 .RS 13n
832 Create errdefs for two byte accesses (\fBddi_get16()\fR)
836 .ne 2
838 \fB\fBfourbyte\fR\fR
840 .RS 13n
841 Create errdefs for four byte accesses (\fBddi_get32()\fR)
845 .ne 2
847 \fB\fBeightbyte\fR\fR
849 .RS 13n
850 Create errdefs for eight byte accesses (\fBddi_get64()\fR)
854 .ne 2
856 \fB\fBmultibyte\fR\fR
858 .RS 13n
859 Create errdefs for repeated byte accesses (\fBddi_rep_get*()\fR)
862 .SS "Frequency of Access Policies"
864 The frequency of access to a location is determined according to the access
865 type, location and transfer size (for example, a two-byte read access to
866 address A is considered distinct from a four-byte read access to address A).
867 The algorithm is to count the number of accesses (of a given type and size) to
868 a given location, and find the locations that were most and least accessed (let
869 \fImaxa\fR and \fImina\fR be the number of times these locations were accessed,
870 and \fImean\fR the total number of accesses divided by total number of
871 locations that were accessed). Then a rare access is a location that was
872 accessed less than
875 \fI(mean - mina) / 3 + mina\fR
878 times. Similarly for the definition of common accesses:
881 \fImaxa - (maxa - mean) / 3\fR
884 A location whose access patterns lies within these cutoffs is regarded as a
885 location that is accessed with median frequency.
887 .ne 2
889 \fB\fBrare\fR\fR
891 .RS 10n
892 Create errdefs for locations that are rarely accessed.
896 .ne 2
898 \fB\fBcommon\fR\fR
900 .RS 10n
901 Create errdefs for locations that are commonly accessed.
905 .ne 2
907 \fB\fBmedian\fR\fR
909 .RS 10n
910 Create errdefs for locations that are accessed a median frequency.
913 .SS "Policies for Minimizing errdefs"
915 If a transaction is duplicated, either a single or multiple errdefs will be
916 written to the test scripts, depending upon the following two policies:
918 .ne 2
920 \fB\fBmaximal\fR\fR
922 .RS 13n
923 Create multiple errdefs for locations that are repeatedly accessed.
927 .ne 2
929 \fB\fBunbiased\fR\fR
931 .RS 13n
932 Create a single errdef for locations that are repeatedly accessed.
936 .ne 2
938 \fB\fBoperators\fR\fR
940 .RS 13n
941 For each location, a default operator and operand is typically applied. For
942 maximal test coverage, this default may be modified using the \fBoperators\fR
943 policy so that a separate errdef is created for each of the possible corruption
944 operators.
947 .SH SEE ALSO
949 \fBkill\fR(1), \fBth_manage\fR(8), \fBalarm\fR(2),
950 \fBddi_check_acc_handle\fR(9F), \fBddi_check_dma_handle\fR(9F)