1 Found UPS at /dev/usb/hid/hiddev0
2 hiddev driver version is 1.0.2
3 HID: vendor 0x51d product 0x2 version 0x6 app UPS
4 HID: bus: 2 devnum: 2 ifnum: 0
5 UPS HID device name: "American Power Conversion Smart-UPS 1000 FW:600.1.I USB FW:1.2"
6 Battery Chemistry: "PbAc" (4)
9 Field 0, app UPS, phys ---
10 Usage 0, RemainingCapacity = 100 percent
13 Field 0, app UPS, phys ---
14 Usage 0, RemainingTimeLimit = 0 Seconds
17 Field 0, app UPS, phys ---
18 Usage 0, AudibleAlarmControl = 2
21 Field 0, app UPS, phys ---
23 Field 1, app UPS, phys ---
24 Usage 0, Discharging = 0
25 Field 2, app UPS, phys ---
26 Usage 0, ACPresent = 1
27 Field 3, app UPS, phys ---
28 Usage 0, BatteryPresent = 1
29 Field 4, app UPS, phys ---
30 Usage 0, BelowRemainingCapacityLimit = 0
31 Field 5, app UPS, phys ---
32 Usage 0, ShutdownRequested = 0
33 Field 6, app UPS, phys ---
34 Usage 0, ShutdownImminent = 0
35 Field 7, app UPS, phys ---
36 Usage 0, RemainingTimeLimitExpired = 0
37 Field 8, app UPS, phys ---
38 Usage 0, CommunicationLost = 0
39 Field 9, app UPS, phys ---
40 Usage 0, NeedReplacement = 0
41 Field 10, app UPS, phys ---
43 Field 11, app UPS, phys ---
44 Usage 0, VoltageNotRegulated = 0
45 Field 12, app UPS, phys ---
46 Usage 0, [ff860080] = 0
49 Field 0, app UPS, phys Battery
53 Field 0, app UPS, phys Battery
54 Usage 0, [ff860019] = 0
57 Field 0, app UPS, phys Battery
58 Usage 0, [ff86001a] = 3
61 Field 0, app UPS, phys Battery
62 Usage 0, [ff86001b] = 0
65 Field 0, app UPS, phys Battery
66 Usage 0, ManufactureDate = 11032 2001-08-24
69 Field 0, app UPS, phys Battery
70 Usage 0, RemainingTimeLimit = 120
73 Field 0, app UPS, phys Input
74 Usage 0, [ff860052] = 0
77 Field 0, app UPS, phys Input
78 Usage 0, [ff860061] = 2
81 Field 0, app UPS, phys Output
82 Usage 0, ConfigVoltage = 230 Volts
85 Field 0, app UPS, phys Output
86 Usage 0, HighVoltageTransfer = 253 Volts
89 Field 0, app UPS, phys Output
90 Usage 0, LowVoltageTransfer = 208 Volts
93 Field 0, app UPS, phys Output
94 Usage 0, [ff86007e] = 0
97 Field 0, app UPS, phys Output
98 Usage 0, APCShutdownAfterDelay = 90
101 Field 0, app UPS, phys ---
102 Usage 0, AudibleAlarmControl = 2
105 Field 0, app UPS, phys ---
106 Usage 0, Charging = 0
107 Field 1, app UPS, phys ---
108 Usage 0, Discharging = 0
109 Field 2, app UPS, phys ---
110 Usage 0, ACPresent = 1
111 Field 3, app UPS, phys ---
112 Usage 0, BatteryPresent = 1
113 Field 4, app UPS, phys ---
114 Usage 0, BelowRemainingCapacityLimit = 0
115 Field 5, app UPS, phys ---
116 Usage 0, ShutdownRequested = 0
117 Field 6, app UPS, phys ---
118 Usage 0, ShutdownImminent = 0
119 Field 7, app UPS, phys ---
120 Usage 0, RemainingTimeLimitExpired = 0
121 Field 8, app UPS, phys ---
122 Usage 0, CommunicationLost = 0
123 Field 9, app UPS, phys ---
124 Usage 0, NeedReplacement = 0
125 Field 10, app UPS, phys ---
126 Usage 0, Overload = 0
127 Field 11, app UPS, phys ---
128 Usage 0, VoltageNotRegulated = 0
129 Field 12, app UPS, phys ---
130 Usage 0, [ff860080] = 0
133 Field 0, app UPS, phys ---
134 Usage 0, iProduct = 1 Smart-UPS 1000 FW:600.1.I USB FW:1.2
137 Field 0, app UPS, phys ---
138 Usage 0, iSerialNumber = 2 AS0134132215
141 Field 0, app UPS, phys ---
142 Usage 0, iManufacturer = 3 American Power Conversion
145 Field 0, app UPS, phys ---
146 Usage 0, iOEMInformation = 3 American Power Conversion
149 Field 0, app UPS, phys ---
150 Usage 0, iDeviceChemistry = 4 PbAc
153 Field 0, app UPS, phys ---
154 Usage 0, Rechargeable = 1
155 Field 1, app UPS, phys ---
156 Usage 0, CapacityMode = 2 percent
159 Field 0, app UPS, phys ---
160 Usage 0, DesignCapacity = 100 percent
161 Field 1, app UPS, phys ---
162 Usage 0, FullChargeCapacity = 100 percent
165 Field 0, app UPS, phys ---
166 Usage 0, RemainingCapacity = 100 percent
169 Field 0, app UPS, phys ---
170 Usage 0, CapacityGranularity1 = 1 percent
171 Field 1, app UPS, phys ---
172 Usage 0, CapacityGranularity2 = 1 percent
175 Field 0, app UPS, phys ---
176 Usage 0, WarningCapacityLimit = 50 percent
179 Field 0, app UPS, phys ---
180 Usage 0, RemainingCapacityLimit = 10 percent
183 Field 0, app UPS, phys ---
184 Usage 0, ManufactureDate = 11032 2001-08-24
187 Field 0, app UPS, phys ---
188 Usage 0, RunTimeToEmpty = 21000 Seconds
191 Field 0, app UPS, phys ---
192 Usage 0, DelayBeforeShutdown = -1
195 Field 0, app UPS, phys ---
196 Usage 0, DelayBeforeReboot = -1 Seconds
199 Field 0, app UPS, phys ---
200 Usage 0, RemainingTimeLimit = 0 Seconds
203 Field 0, app UPS, phys ---
204 Usage 0, ConfigVoltage = 2400 CentiVolts
207 Field 0, app UPS, phys ---
208 Usage 0, Voltage = 2754 CentiVolts
211 Field 0, app UPS, phys ---
212 Usage 0, AudibleAlarmControl = 2
215 Field 0, app UPS, phys ---
216 Usage 0, Charging = 0
217 Field 1, app UPS, phys ---
218 Usage 0, Discharging = 0
219 Field 2, app UPS, phys ---
220 Usage 0, ACPresent = 1
221 Field 3, app UPS, phys ---
222 Usage 0, BatteryPresent = 1
223 Field 4, app UPS, phys ---
224 Usage 0, BelowRemainingCapacityLimit = 0
225 Field 5, app UPS, phys ---
226 Usage 0, ShutdownRequested = 0
227 Field 6, app UPS, phys ---
228 Usage 0, ShutdownImminent = 0
229 Field 7, app UPS, phys ---
230 Usage 0, RemainingTimeLimitExpired = 0
231 Field 8, app UPS, phys ---
232 Usage 0, CommunicationLost = 0
233 Field 9, app UPS, phys ---
234 Usage 0, NeedReplacement = 0
235 Field 10, app UPS, phys ---
236 Usage 0, Overload = 0
237 Field 11, app UPS, phys ---
238 Usage 0, VoltageNotRegulated = 0
239 Field 12, app UPS, phys ---
240 Usage 0, [ff860080] = 0
243 Field 0, app UPS, phys Battery
247 Field 0, app UPS, phys Battery
248 Usage 0, [ff860019] = 0
251 Field 0, app UPS, phys Battery
252 Usage 0, [ff86001a] = 3
255 Field 0, app UPS, phys Battery
256 Usage 0, [ff86001b] = 0
259 Field 0, app UPS, phys Battery
260 Usage 0, ManufactureDate = 11032 2001-08-24
263 Field 0, app UPS, phys Battery
264 Usage 0, RemainingCapacity = 1000 percent
267 Field 0, app UPS, phys Battery
268 Usage 0, RemainingTimeLimit = 120
271 Field 0, app UPS, phys Battery
272 Usage 0, RunTimeToEmpty = 21000
275 Field 0, app UPS, phys Battery
276 Usage 0, Temperature = 3001 Degrees K with -1 exponent
279 Field 0, app UPS, phys Battery
280 Usage 0, ConfigVoltage = 2400 CentiVolts
283 Field 0, app UPS, phys Battery
284 Usage 0, Voltage = 2754 CentiVolts
287 Field 0, app UPS, phys Input
288 Usage 0, Voltage = 2304 DeciVolts
291 Field 0, app UPS, phys Input
292 Usage 0, [ff860052] = 0
295 Field 0, app UPS, phys Input
296 Usage 0, [ff860061] = 2
299 Field 0, app UPS, phys Output
300 Usage 0, PercentLoad = 0
303 Field 0, app UPS, phys Output
304 Usage 0, Frequency = 5000 CentiHertz
307 Field 0, app UPS, phys Output
308 Usage 0, Voltage = 2304 DeciVolts
311 Field 0, app UPS, phys Output
312 Usage 0, ConfigVoltage = 230 Volts
315 Field 0, app UPS, phys Output
316 Usage 0, HighVoltageTransfer = 253 Volts
319 Field 0, app UPS, phys Output
320 Usage 0, LowVoltageTransfer = 208 Volts
323 Field 0, app UPS, phys Output
324 Usage 0, [ff86007e] = 0
327 Field 0, app UPS, phys Output
328 Usage 0, APCShutdownAfterDelay = 90
331 Field 0, app UPS, phys Output
332 Usage 0, DelayBeforeShutdown = -1
335 Field 0, app UPS, phys Output
336 Usage 0, DelayBeforeStartup = -1 Seconds
339 Field 0, app UPS, phys Output
340 Usage 0, DelayBeforeReboot = -1 Seconds
343 Field 0, app UPS, phys ---
344 Usage 0, iProduct = 5 Smart-UPS 1000
347 Field 0, app UPS, phys ---
348 Usage 0, iSerialNumber = 2 AS0134132215
351 Field 0, app UPS, phys ---
352 Usage 0, iManufacturer = 3 American Power Conversion
355 Field 0, app UPS, phys ---
356 Usage 0, iName = 6 UPSIDEN
359 Field 0, app UPS, phys ---
360 Usage 0, APC_UPS_FirmwareRevision = 7
363 Field 0, app UPS, phys ---
364 Usage 0, APC_USB_FirmwareRevision = 8
367 Field 0, app UPS, phys ---
368 Usage 0, APCPanelTest = 1
371 Field 0, app UPS, phys ---
372 Usage 0, ManufactureDate = 11032 2001-08-24
375 Field 0, app UPS, phys ---
376 Usage 0, [ff860027] = 0
379 Field 0, app UPS, phys ---
380 Usage 0, [ff860028] = 0
383 Field 0, app UPS, phys ---
384 Usage 0, AudibleAlarmControl = 2
387 Field 0, app UPS, phys ---
388 Usage 0, Charging = 0
389 Field 1, app UPS, phys ---
390 Usage 0, Discharging = 0
391 Field 2, app UPS, phys ---
392 Usage 0, ACPresent = 1
393 Field 3, app UPS, phys ---
394 Usage 0, BatteryPresent = 1
395 Field 4, app UPS, phys ---
396 Usage 0, BelowRemainingCapacityLimit = 0
397 Field 5, app UPS, phys ---
398 Usage 0, ShutdownRequested = 0
399 Field 6, app UPS, phys ---
400 Usage 0, ShutdownImminent = 0
401 Field 7, app UPS, phys ---
402 Usage 0, RemainingTimeLimitExpired = 0
403 Field 8, app UPS, phys ---
404 Usage 0, CommunicationLost = 0
405 Field 9, app UPS, phys ---
406 Usage 0, NeedReplacement = 0
407 Field 10, app UPS, phys ---
408 Usage 0, Overload = 0
409 Field 11, app UPS, phys ---
410 Usage 0, VoltageNotRegulated = 0
411 Field 12, app UPS, phys ---
412 Usage 0, [ff860080] = 0
414 Waiting for events ... (interrupt to exit)