1 Found UPS at /dev/usb/hid/hiddev0
2 hiddev driver version is 1.0.2
3 HID: vendor 0x51d product 0x2 version 0x6 app UPS
4 HID: bus: 2 devnum: 2 ifnum: 0
5 UPS HID device name: "American Power Conversion Smart-UPS 1000 FW:600.1.I USB FW:1.2"
6 Battery Chemistry: "PbAc" (4)
9 Field 0, app UPS, phys ---
11 Usage 0, RemainingCapacity = 100 percent
14 Field 0, app UPS, phys ---
15 Usage 0, RemainingTimeLimit = 0 Seconds
18 Field 0, app UPS, phys ---
19 Usage 0, AudibleAlarmControl = 2
22 Field 0, app UPS, phys ---
24 Field 1, app UPS, phys ---
25 Usage 0, Discharging = 0
26 Field 2, app UPS, phys ---
27 Usage 0, ACPresent = 1
28 Field 3, app UPS, phys ---
29 Usage 0, BatteryPresent = 1
30 Field 4, app UPS, phys ---
31 Usage 0, BelowRemainingCapacityLimit = 0
32 Field 5, app UPS, phys ---
33 Usage 0, ShutdownRequested = 0
34 Field 6, app UPS, phys ---
35 Usage 0, ShutdownImminent = 0
36 Field 7, app UPS, phys ---
37 Usage 0, RemainingTimeLimitExpired = 0
38 Field 8, app UPS, phys ---
39 Usage 0, CommunicationLost = 0
40 Field 9, app UPS, phys ---
41 Usage 0, NeedReplacement = 0
42 Field 10, app UPS, phys ---
44 Field 11, app UPS, phys ---
45 Usage 0, VoltageNotRegulated = 0
46 Field 12, app UPS, phys ---
47 Usage 0, [ff860080] = 0
50 Field 0, app UPS, phys Battery
54 Field 0, app UPS, phys Battery
55 Usage 0, [ff860019] = 0
58 Field 0, app UPS, phys Battery
59 Usage 0, [ff86001a] = 3
62 Field 0, app UPS, phys Battery
63 Usage 0, [ff86001b] = 0
66 Field 0, app UPS, phys Battery
67 Usage 0, ManufactureDate = 11032 2001-08-24
70 Field 0, app UPS, phys Battery
71 Usage 0, RemainingTimeLimit = 120
74 Field 0, app UPS, phys Input
75 Usage 0, [ff860052] = 5
78 Field 0, app UPS, phys Input
79 Usage 0, [ff860061] = 2
82 Field 0, app UPS, phys Output
83 Usage 0, ConfigVoltage = 230 Volts
86 Field 0, app UPS, phys Output
87 Usage 0, HighVoltageTransfer = 253 Volts
90 Field 0, app UPS, phys Output
91 Usage 0, LowVoltageTransfer = 208 Volts
94 Field 0, app UPS, phys Output
95 Usage 0, [ff86007e] = 0
98 Field 0, app UPS, phys Output
99 Usage 0, APCShutdownAfterDelay = 90
102 Field 0, app UPS, phys ---
103 Usage 0, AudibleAlarmControl = 2
106 Field 0, app UPS, phys ---
107 Usage 0, Charging = 0
108 Field 1, app UPS, phys ---
109 Usage 0, Discharging = 0
110 Field 2, app UPS, phys ---
111 Usage 0, ACPresent = 1
112 Field 3, app UPS, phys ---
113 Usage 0, BatteryPresent = 1
114 Field 4, app UPS, phys ---
115 Usage 0, BelowRemainingCapacityLimit = 0
116 Field 5, app UPS, phys ---
117 Usage 0, ShutdownRequested = 0
118 Field 6, app UPS, phys ---
119 Usage 0, ShutdownImminent = 0
120 Field 7, app UPS, phys ---
121 Usage 0, RemainingTimeLimitExpired = 0
122 Field 8, app UPS, phys ---
123 Usage 0, CommunicationLost = 0
124 Field 9, app UPS, phys ---
125 Usage 0, NeedReplacement = 0
126 Field 10, app UPS, phys ---
127 Usage 0, Overload = 0
128 Field 11, app UPS, phys ---
129 Usage 0, VoltageNotRegulated = 0
130 Field 12, app UPS, phys ---
131 Usage 0, [ff860080] = 0
134 Field 0, app UPS, phys ---
135 Usage 0, iProduct = 1 Smart-UPS 1000 FW:600.1.I USB FW:1.2
138 Field 0, app UPS, phys ---
139 Usage 0, iSerialNumber = 2 AS0134132215
142 Field 0, app UPS, phys ---
143 Usage 0, iManufacturer = 3 American Power Conversion
146 Field 0, app UPS, phys ---
147 Usage 0, iOEMInformation = 3 American Power Conversion
150 Field 0, app UPS, phys ---
151 Usage 0, iDeviceChemistry = 4 PbAc
154 Field 0, app UPS, phys ---
155 Usage 0, Rechargeable = 1
156 Field 1, app UPS, phys ---
158 Usage 0, CapacityMode = 2 percent
161 Field 0, app UPS, phys ---
163 Usage 0, DesignCapacity = 100 percent
164 Field 1, app UPS, phys ---
166 Usage 0, FullChargeCapacity = 100 percent
169 Field 0, app UPS, phys ---
171 Usage 0, RemainingCapacity = 100 percent
174 Field 0, app UPS, phys ---
176 Usage 0, CapacityGranularity1 = 1 percent
177 Field 1, app UPS, phys ---
179 Usage 0, CapacityGranularity2 = 1 percent
182 Field 0, app UPS, phys ---
184 Usage 0, WarningCapacityLimit = 50 percent
187 Field 0, app UPS, phys ---
189 Usage 0, RemainingCapacityLimit = 10 percent
192 Field 0, app UPS, phys ---
193 Usage 0, ManufactureDate = 11032 2001-08-24
196 Field 0, app UPS, phys ---
197 Usage 0, RunTimeToEmpty = 21000 Seconds
200 Field 0, app UPS, phys ---
201 Usage 0, DelayBeforeShutdown = -1
204 Field 0, app UPS, phys ---
205 Usage 0, DelayBeforeReboot = -1 Seconds
208 Field 0, app UPS, phys ---
209 Usage 0, RemainingTimeLimit = 0 Seconds
212 Field 0, app UPS, phys ---
213 Usage 0, ConfigVoltage = 2400 CentiVolts
216 Field 0, app UPS, phys ---
217 Usage 0, Voltage = 2754 CentiVolts
220 Field 0, app UPS, phys ---
221 Usage 0, AudibleAlarmControl = 2
224 Field 0, app UPS, phys ---
225 Usage 0, Charging = 0
226 Field 1, app UPS, phys ---
227 Usage 0, Discharging = 0
228 Field 2, app UPS, phys ---
229 Usage 0, ACPresent = 1
230 Field 3, app UPS, phys ---
231 Usage 0, BatteryPresent = 1
232 Field 4, app UPS, phys ---
233 Usage 0, BelowRemainingCapacityLimit = 0
234 Field 5, app UPS, phys ---
235 Usage 0, ShutdownRequested = 0
236 Field 6, app UPS, phys ---
237 Usage 0, ShutdownImminent = 0
238 Field 7, app UPS, phys ---
239 Usage 0, RemainingTimeLimitExpired = 0
240 Field 8, app UPS, phys ---
241 Usage 0, CommunicationLost = 0
242 Field 9, app UPS, phys ---
243 Usage 0, NeedReplacement = 0
244 Field 10, app UPS, phys ---
245 Usage 0, Overload = 0
246 Field 11, app UPS, phys ---
247 Usage 0, VoltageNotRegulated = 0
248 Field 12, app UPS, phys ---
249 Usage 0, [ff860080] = 0
252 Field 0, app UPS, phys Battery
256 Field 0, app UPS, phys Battery
257 Usage 0, [ff860019] = 0
260 Field 0, app UPS, phys Battery
261 Usage 0, [ff86001a] = 3
264 Field 0, app UPS, phys Battery
265 Usage 0, [ff86001b] = 0
268 Field 0, app UPS, phys Battery
269 Usage 0, ManufactureDate = 11032 2001-08-24
272 Field 0, app UPS, phys Battery
274 Usage 0, RemainingCapacity = 1000 percent
277 Field 0, app UPS, phys Battery
278 Usage 0, RemainingTimeLimit = 120
281 Field 0, app UPS, phys Battery
282 Usage 0, RunTimeToEmpty = 21000
285 Field 0, app UPS, phys Battery
286 Usage 0, Temperature = 2996 Degrees K with -1 exponent
289 Field 0, app UPS, phys Battery
290 Usage 0, ConfigVoltage = 2400 CentiVolts
293 Field 0, app UPS, phys Battery
294 Usage 0, Voltage = 2754 CentiVolts
297 Field 0, app UPS, phys Input
298 Usage 0, Voltage = 2347 DeciVolts
301 Field 0, app UPS, phys Input
302 Usage 0, [ff860052] = 5
305 Field 0, app UPS, phys Input
306 Usage 0, [ff860061] = 2
309 Field 0, app UPS, phys Output
310 Usage 0, PercentLoad = 0
313 Field 0, app UPS, phys Output
314 Usage 0, Frequency = 5000 CentiHertz
317 Field 0, app UPS, phys Output
318 Usage 0, Voltage = 2347 DeciVolts
321 Field 0, app UPS, phys Output
322 Usage 0, ConfigVoltage = 230 Volts
325 Field 0, app UPS, phys Output
326 Usage 0, HighVoltageTransfer = 253 Volts
329 Field 0, app UPS, phys Output
330 Usage 0, LowVoltageTransfer = 208 Volts
333 Field 0, app UPS, phys Output
334 Usage 0, [ff86007e] = 0
337 Field 0, app UPS, phys Output
338 Usage 0, APCShutdownAfterDelay = 90
341 Field 0, app UPS, phys Output
342 Usage 0, DelayBeforeShutdown = -1
345 Field 0, app UPS, phys Output
346 Usage 0, DelayBeforeStartup = -1 Seconds
349 Field 0, app UPS, phys Output
350 Usage 0, DelayBeforeReboot = -1 Seconds
353 Field 0, app UPS, phys ---
354 Usage 0, iProduct = 5 Smart-UPS 1000
357 Field 0, app UPS, phys ---
358 Usage 0, iSerialNumber = 2 AS0134132215
361 Field 0, app UPS, phys ---
362 Usage 0, iManufacturer = 3 American Power Conversion
365 Field 0, app UPS, phys ---
366 Usage 0, iName = 6 UPSIDEN
369 Field 0, app UPS, phys ---
370 Usage 0, APC_UPS_FirmwareRevision = 7
373 Field 0, app UPS, phys ---
374 Usage 0, APC_USB_FirmwareRevision = 8
377 Field 0, app UPS, phys ---
378 Usage 0, APCPanelTest = 1
381 Field 0, app UPS, phys ---
382 Usage 0, ManufactureDate = 11032 2001-08-24
385 Field 0, app UPS, phys ---
386 Usage 0, [ff860027] = 0
389 Field 0, app UPS, phys ---
390 Usage 0, [ff860028] = 0
393 Field 0, app UPS, phys ---
394 Usage 0, AudibleAlarmControl = 2
397 Field 0, app UPS, phys ---
398 Usage 0, Charging = 0
399 Field 1, app UPS, phys ---
400 Usage 0, Discharging = 0
401 Field 2, app UPS, phys ---
402 Usage 0, ACPresent = 1
403 Field 3, app UPS, phys ---
404 Usage 0, BatteryPresent = 1
405 Field 4, app UPS, phys ---
406 Usage 0, BelowRemainingCapacityLimit = 0
407 Field 5, app UPS, phys ---
408 Usage 0, ShutdownRequested = 0
409 Field 6, app UPS, phys ---
410 Usage 0, ShutdownImminent = 0
411 Field 7, app UPS, phys ---
412 Usage 0, RemainingTimeLimitExpired = 0
413 Field 8, app UPS, phys ---
414 Usage 0, CommunicationLost = 0
415 Field 9, app UPS, phys ---
416 Usage 0, NeedReplacement = 0
417 Field 10, app UPS, phys ---
418 Usage 0, Overload = 0
419 Field 11, app UPS, phys ---
420 Usage 0, VoltageNotRegulated = 0
421 Field 12, app UPS, phys ---
422 Usage 0, [ff860080] = 0
424 Waiting for events ... (interrupt to exit)