1 FROM: Jan Ceuleers <jan.ceuleers@computer.org>
\r
3 Found UPS at /dev/usb/hiddev0
\r
4 hiddev driver version is 1.0.2
\r
5 HID: vendor 0x51d product 0x2 version 0x6 app UPS
\r
6 HID: bus: 2 devnum: 2 ifnum: 0
\r
7 UPS HID device name: "American Power Conversion Back-UPS CS 650 FW:817.v4.I USB FW:v4"
\r
8 Battery Chemistry: "PbAc" (4)
\r
11 Field 0, app UPS, phys ---
\r
13 Usage 0, RemainingCapacity = 100 percent
\r
16 Field 0, app UPS, phys ---
\r
17 Usage 0, RunTimeToEmpty = 1462 Seconds
\r
20 Field 0, app UPS, phys ---
\r
21 Usage 0, Charging = 0
\r
22 Field 1, app UPS, phys ---
\r
23 Usage 0, Discharging = 0
\r
24 Field 2, app UPS, phys ---
\r
25 Usage 0, ACPresent = 1
\r
26 Field 3, app UPS, phys ---
\r
27 Usage 0, BatteryPresent = 1
\r
28 Field 4, app UPS, phys ---
\r
29 Usage 0, BelowRemainingCapacityLimit = 0
\r
30 Field 5, app UPS, phys ---
\r
31 Usage 0, ShutdownRequested = 0
\r
32 Field 6, app UPS, phys ---
\r
33 Usage 0, ShutdownImminent = 0
\r
34 Field 7, app UPS, phys ---
\r
35 Usage 0, RemainingTimeLimitExpired = 0
\r
36 Field 8, app UPS, phys ---
\r
37 Usage 0, CommunicationLost = 0
\r
38 Field 9, app UPS, phys ---
\r
39 Usage 0, NeedReplacement = 0
\r
40 Field 10, app UPS, phys ---
\r
41 Usage 0, Overload = 0
\r
42 Field 11, app UPS, phys ---
\r
43 Usage 0, VoltageNotRegulated = 0
\r
44 Field 12, app UPS, phys ---
\r
45 Usage 0, [ff860080] = 0
\r
48 Field 0, app UPS, phys Battery
\r
52 Field 0, app UPS, phys ---
\r
53 Usage 0, Charging = 0
\r
54 Field 1, app UPS, phys ---
\r
55 Usage 0, Discharging = 0
\r
56 Field 2, app UPS, phys ---
\r
57 Usage 0, ACPresent = 1
\r
58 Field 3, app UPS, phys ---
\r
59 Usage 0, BatteryPresent = 1
\r
60 Field 4, app UPS, phys ---
\r
61 Usage 0, BelowRemainingCapacityLimit = 0
\r
62 Field 5, app UPS, phys ---
\r
63 Usage 0, ShutdownRequested = 0
\r
64 Field 6, app UPS, phys ---
\r
65 Usage 0, ShutdownImminent = 0
\r
66 Field 7, app UPS, phys ---
\r
67 Usage 0, RemainingTimeLimitExpired = 0
\r
68 Field 8, app UPS, phys ---
\r
69 Usage 0, CommunicationLost = 0
\r
70 Field 9, app UPS, phys ---
\r
71 Usage 0, NeedReplacement = 0
\r
72 Field 10, app UPS, phys ---
\r
73 Usage 0, Overload = 0
\r
74 Field 11, app UPS, phys ---
\r
75 Usage 0, VoltageNotRegulated = 0
\r
76 Field 12, app UPS, phys ---
\r
77 Usage 0, [ff860080] = 0
\r
80 Field 0, app UPS, phys ---
\r
81 Usage 0, iProduct = 1 Back-UPS CS 650 FW:817.v4.I USB FW:v4
\r
84 Field 0, app UPS, phys ---
\r
85 Usage 0, iSerialNumber = 2 QB0642232674
\r
88 Field 0, app UPS, phys ---
\r
89 Usage 0, iManufacturer = 3 American Power Conversion
\r
92 Field 0, app UPS, phys ---
\r
93 Usage 0, iOEMInformation = 3 American Power Conversion
\r
96 Field 0, app UPS, phys ---
\r
97 Usage 0, iDeviceChemistry = 4 PbAc
\r
100 Field 0, app UPS, phys ---
\r
101 Usage 0, Rechargeable = 1
\r
102 Field 1, app UPS, phys ---
\r
104 Usage 0, CapacityMode = 2 percent
\r
107 Field 0, app UPS, phys ---
\r
109 Usage 0, DesignCapacity = 100 percent
\r
110 Field 1, app UPS, phys ---
\r
112 Usage 0, FullChargeCapacity = 100 percent
\r
115 Field 0, app UPS, phys ---
\r
117 Usage 0, RemainingCapacity = 100 percent
\r
120 Field 0, app UPS, phys ---
\r
122 Usage 0, CapacityGranularity1 = 1 percent
\r
123 Field 1, app UPS, phys ---
\r
125 Usage 0, CapacityGranularity2 = 1 percent
\r
128 Field 0, app UPS, phys ---
\r
130 Usage 0, WarningCapacityLimit = 50 percent
\r
133 Field 0, app UPS, phys ---
\r
135 Usage 0, RemainingCapacityLimit = 10 percent
\r
138 Field 0, app UPS, phys ---
\r
139 Usage 0, ManufactureDate = 13644 2006-10-12
\r
142 Field 0, app UPS, phys ---
\r
143 Usage 0, RunTimeToEmpty = 1530 Seconds
\r
146 Field 0, app UPS, phys ---
\r
147 Usage 0, DelayBeforeShutdown = -1
\r
150 Field 0, app UPS, phys ---
\r
151 Usage 0, DelayBeforeReboot = 0 Seconds
\r
154 Field 0, app UPS, phys ---
\r
155 Usage 0, RemainingTimeLimit = 120 Seconds
\r
158 Field 0, app UPS, phys ---
\r
159 Usage 0, ConfigVoltage = 1200 CentiVolts
\r
162 Field 0, app UPS, phys ---
\r
163 Usage 0, Voltage = 1351 CentiVolts
\r
166 Field 0, app UPS, phys ---
\r
167 Usage 0, AudibleAlarmControl = 1
\r
170 Field 0, app UPS, phys ---
\r
171 Usage 0, Charging = 0
\r
172 Field 1, app UPS, phys ---
\r
173 Usage 0, Discharging = 0
\r
174 Field 2, app UPS, phys ---
\r
175 Usage 0, ACPresent = 1
\r
176 Field 3, app UPS, phys ---
\r
177 Usage 0, BatteryPresent = 1
\r
178 Field 4, app UPS, phys ---
\r
179 Usage 0, BelowRemainingCapacityLimit = 0
\r
180 Field 5, app UPS, phys ---
\r
181 Usage 0, ShutdownRequested = 0
\r
182 Field 6, app UPS, phys ---
\r
183 Usage 0, ShutdownImminent = 0
\r
184 Field 7, app UPS, phys ---
\r
185 Usage 0, RemainingTimeLimitExpired = 0
\r
186 Field 8, app UPS, phys ---
\r
187 Usage 0, CommunicationLost = 0
\r
188 Field 9, app UPS, phys ---
\r
189 Usage 0, NeedReplacement = 0
\r
190 Field 10, app UPS, phys ---
\r
191 Usage 0, Overload = 0
\r
192 Field 11, app UPS, phys ---
\r
193 Usage 0, VoltageNotRegulated = 0
\r
194 Field 12, app UPS, phys ---
\r
195 Usage 0, [ff860080] = 0
\r
198 Field 0, app UPS, phys Battery
\r
202 Field 0, app UPS, phys Battery
\r
203 Usage 0, APCBattCapBeforeStartup = 0
\r
206 Field 0, app UPS, phys Battery
\r
207 Usage 0, [ff86001a] = 0
\r
210 Field 0, app UPS, phys Battery
\r
211 Usage 0, [ff86001b] = 0
\r
214 Field 0, app UPS, phys Battery
\r
215 Usage 0, APCBattReplacementDate = 1053190 2006-10-12
\r
219 Field 0, app UPS, phys Battery
\r
220 Usage 0, ManufactureDate = 13644 2006-10-12
\r
223 Field 0, app UPS, phys Battery
\r
225 Usage 0, RemainingCapacity = 1000 percent
\r
228 Field 0, app UPS, phys Battery
\r
229 Usage 0, RemainingTimeLimit = 120 Seconds
\r
232 Field 0, app UPS, phys Battery
\r
233 Usage 0, RunTimeToEmpty = 1507 Seconds
\r
236 Field 0, app UPS, phys Battery
\r
237 Usage 0, Temperature = 3023 Degrees K with -1 exponent
\r
240 Field 0, app UPS, phys Battery
\r
241 Usage 0, ConfigVoltage = 1200 CentiVolts
\r
244 Field 0, app UPS, phys Battery
\r
245 Usage 0, Voltage = 1351 CentiVolts
\r
248 Field 0, app UPS, phys Battery
\r
249 Usage 0, APC860024_?????? = 240
\r
252 Field 0, app UPS, phys Battery
\r
253 Usage 0, [ff860018] = 0
\r
256 Field 0, app UPS, phys Input
\r
257 Usage 0, Voltage = 0 DeciVolts
\r
260 Field 0, app UPS, phys Input
\r
261 Usage 0, ConfigVoltage = 230 Volts
\r
264 Field 0, app UPS, phys Input
\r
265 Usage 0, APCLineFailCause = 12
\r
268 Field 0, app UPS, phys Input
\r
269 Usage 0, APC860061_?????? = 1
\r
272 Field 0, app UPS, phys Input
\r
273 Usage 0, APC860024_?????? = 126
\r
276 Field 0, app UPS, phys Output
\r
277 Usage 0, PercentLoad = 250
\r
280 Field 0, app UPS, phys Output
\r
281 Usage 0, ConfigActivePower = 400 Watts
\r
284 Field 0, app UPS, phys Output
\r
285 Usage 0, Frequency = 5000 CentiHertz
\r
288 Field 0, app UPS, phys Output
\r
289 Usage 0, Voltage = 2300 DeciVolts
\r
292 Field 0, app UPS, phys Output
\r
293 Usage 0, ConfigVoltage = 0 Volts
\r
296 Field 0, app UPS, phys Output
\r
297 Usage 0, HighVoltageTransfer = 260 Volts
\r
300 Field 0, app UPS, phys Output
\r
301 Usage 0, LowVoltageTransfer = 0 Volts
\r
304 Field 0, app UPS, phys Output
\r
305 Usage 0, APCDelayBeforeStartup = 0 Seconds
\r
308 Field 0, app UPS, phys Output
\r
309 Usage 0, APCShutdownAfterDelay = 0 Seconds
\r
312 Field 0, app UPS, phys Output
\r
313 Usage 0, DelayBeforeShutdown = -1
\r
316 Field 0, app UPS, phys Output
\r
317 Usage 0, DelayBeforeStartup = 0 Seconds
\r
320 Field 0, app UPS, phys Output
\r
321 Usage 0, DelayBeforeReboot = 0 Seconds
\r
324 Field 0, app UPS, phys Output
\r
325 Usage 0, APCForceShutdown = 0
\r
328 Field 0, app UPS, phys Output
\r
329 Usage 0, APCDelayBeforeShutdown = -1 Seconds
\r
332 Field 0, app UPS, phys ---
\r
333 Usage 0, iProduct = 5 Back-UPS CS 650
\r
336 Field 0, app UPS, phys ---
\r
337 Usage 0, iSerialNumber = 2 QB0642232674
\r
340 Field 0, app UPS, phys ---
\r
341 Usage 0, iManufacturer = 3 American Power Conversion
\r
344 Field 0, app UPS, phys ---
\r
345 Usage 0, iName = 6 APC
\r
348 Field 0, app UPS, phys ---
\r
349 Usage 0, APC_UPS_FirmwareRevision = 7
\r
352 Field 0, app UPS, phys ---
\r
353 Usage 0, APC_USB_FirmwareRevision = 8
\r
356 Field 0, app UPS, phys ---
\r
357 Usage 0, APCPanelTest = 0
\r
360 Field 0, app UPS, phys ---
\r
361 Usage 0, ManufactureDate = 13644 2006-10-12
\r
364 Field 0, app UPS, phys ---
\r
365 Usage 0, [ff860027] = 0
\r
368 Field 0, app UPS, phys ---
\r
369 Usage 0, [ff860028] = 0
\r
372 Field 0, app UPS, phys ---
\r
373 Usage 0, AudibleAlarmControl = 1
\r
376 Field 0, app UPS, phys ---
\r
377 Usage 0, Charging = 0
\r
378 Field 1, app UPS, phys ---
\r
379 Usage 0, Discharging = 0
\r
380 Field 2, app UPS, phys ---
\r
381 Usage 0, ACPresent = 1
\r
382 Field 3, app UPS, phys ---
\r
383 Usage 0, BatteryPresent = 1
\r
384 Field 4, app UPS, phys ---
\r
385 Usage 0, BelowRemainingCapacityLimit = 0
\r
386 Field 5, app UPS, phys ---
\r
387 Usage 0, ShutdownRequested = 0
\r
388 Field 6, app UPS, phys ---
\r
389 Usage 0, ShutdownImminent = 0
\r
390 Field 7, app UPS, phys ---
\r
391 Usage 0, RemainingTimeLimitExpired = 0
\r
392 Field 8, app UPS, phys ---
\r
393 Usage 0, CommunicationLost = 0
\r
394 Field 9, app UPS, phys ---
\r
395 Usage 0, NeedReplacement = 0
\r
396 Field 10, app UPS, phys ---
\r
397 Usage 0, Overload = 0
\r
398 Field 11, app UPS, phys ---
\r
399 Usage 0, VoltageNotRegulated = 0
\r
400 Field 12, app UPS, phys ---
\r
401 Usage 0, [ff860080] = 0
\r
404 Field 0, app UPS, phys [ff860001]
\r
405 Usage 0, APC860023_?????? = 0
\r
408 Field 0, app UPS, phys [ff860001]
\r
409 Usage 0, APC860026_?????? = 14
\r
412 Field 0, app UPS, phys [ff860001]
\r
413 Usage 0, APC860025_?????? = 0
\r
416 Field 0, app UPS, phys PowerConverter
\r
417 Usage 0, APC860024_?????? = 148
\r
419 Waiting for events ... (interrupt to exit)
\r
420 Event: RunTimeToEmpty = 1507
\r
421 Event: RunTimeToEmpty = 1507
\r
422 Event: RunTimeToEmpty = 1485
\r
423 Event: RunTimeToEmpty = 1462
\r
424 Event: RunTimeToEmpty = 1485
\r
425 Event: RunTimeToEmpty = 1507
\r
426 Event: RunTimeToEmpty = 1530
\r
427 Event: RunTimeToEmpty = 1507
\r
428 Event: RunTimeToEmpty = 1530
\r