1 Found UPS at /dev/usb/hid/hiddev0
2 hiddev driver version is 1.0.2
3 HID: vendor 0x51d product 0x2 version 0x100 app UPS
4 HID: bus: 1 devnum: 2 ifnum: 0
5 UPS HID device name: "American Power Conversion Back-UPS ES/CyberFort
6 350 FW: 3.1.I USB FW: d1"
7 Battery Chemistry: "PbAc" (4)
10 Field 0, app UPS, phys PowerSummary
12 Field 1, app UPS, phys PowerSummary
13 Usage 0, Discharging = 0
14 Field 2, app UPS, phys PowerSummary
15 Usage 0, APCStatusFlag = 8 0x8
18 Field 0, app UPS, phys PowerSummary
20 Usage 0, RemainingCapacity = 100 percent
21 Field 1, app UPS, phys PowerSummary
22 Usage 0, RunTimeToEmpty = 360 Seconds
25 Field 0, app UPS, phys PowerSummary
26 Usage 0, ACPresent = 1
29 Field 0, app UPS, phys PowerSummary
30 Usage 0, BelowRemainingCapacityLimit = 0
31 Field 1, app UPS, phys PowerSummary
32 Usage 0, ShutdownImminent = 0
35 Field 0, app UPS, phys PowerSummary
36 Usage 0, iProduct = 1 Back-UPS ES/CyberFort 350 FW: 3.1.I USB FW: d1
39 Field 0, app UPS, phys PowerSummary
40 Usage 0, iSerialNumber = 2 AB0233221824
43 Field 0, app UPS, phys PowerSummary
44 Usage 0, iDeviceChemistry = 4 PbAc
47 Field 0, app UPS, phys PowerSummary
48 Usage 0, iOEMInformation = 3 American Power Conversion
51 Field 0, app UPS, phys PowerSummary
52 Usage 0, Rechargeable = 1
55 Field 0, app UPS, phys PowerSummary
57 Field 1, app UPS, phys PowerSummary
58 Usage 0, Discharging = 0
59 Field 2, app UPS, phys PowerSummary
60 Usage 0, APCStatusFlag = 8 0x8
63 Field 0, app UPS, phys PowerSummary
64 Usage 0, ManufactureDate = 11535 2002-08-15
67 Field 0, app UPS, phys PowerSummary
68 Usage 0, ConfigVoltage = 1200 CentiVolts
71 Field 0, app UPS, phys PowerSummary
72 Usage 0, Voltage = 1327 CentiVolts
75 Field 0, app UPS, phys PowerSummary
76 Usage 0, iManufacturer = 3 American Power Conversion
79 Field 0, app UPS, phys PowerSummary
81 Usage 0, CapacityMode = 2 percent
84 Field 0, app UPS, phys PowerSummary
86 Usage 0, RemainingCapacity = 100 percent
87 Field 1, app UPS, phys PowerSummary
88 Usage 0, RunTimeToEmpty = 360 Seconds
91 Field 0, app UPS, phys PowerSummary
93 Usage 0, DesignCapacity = 100 percent
96 Field 0, app UPS, phys PowerSummary
98 Usage 0, FullChargeCapacity = 100 percent
101 Field 0, app UPS, phys PowerSummary
103 Usage 0, WarningCapacityLimit = 50 percent
106 Field 0, app UPS, phys PowerSummary
108 Usage 0, CapacityGranularity2 = 1 percent
111 Field 0, app UPS, phys PowerSummary
113 Usage 0, RemainingCapacityLimit = 10 percent
116 Field 0, app UPS, phys PowerSummary
118 Usage 0, CapacityGranularity1 = 1 percent
121 Field 0, app UPS, phys PowerSummary
122 Usage 0, ACPresent = 1
125 Field 0, app UPS, phys PowerSummary
126 Usage 0, BelowRemainingCapacityLimit = 0
127 Field 1, app UPS, phys PowerSummary
128 Usage 0, ShutdownImminent = 0
131 Field 0, app UPS, phys PowerSummary
132 Usage 0, APCPanelTest = 0
135 Field 0, app UPS, phys PowerSummary
136 Usage 0, APCBattReplacementDate = 529666 2002-08-15
140 Field 0, app UPS, phys APCGeneralCollection
141 Usage 0, APCForceShutdown = 0
143 Waiting for events ... (interrupt to exit)