3 CPU topology on s390x
4 =====================
6 Since QEMU 8.2, CPU topology on s390x provides up to 3 levels of
7 topology containers: drawers, books and sockets. They define a
8 tree-shaped hierarchy.
10 The socket container has one or more CPU entries.
11 Each of these CPU entries consists of a bitmap and three CPU attributes:
13 - CPU type
14 - entitlement
15 - dedication
17 Each bit set in the bitmap correspond to a core-id of a vCPU with matching
18 attributes.
20 This documentation provides general information on S390 CPU topology,
21 how to enable it and explains the new CPU attributes.
22 For information on how to modify the S390 CPU topology and how to
23 monitor polarization changes, see ``docs/devel/s390-cpu-topology.rst``.
25 Prerequisites
26 -------------
28 To use the CPU topology, you currently need to choose the KVM accelerator.
29 See :ref:`Accelerators` for more details about accelerators and how to select them.
31 The s390x host needs to use a Linux kernel v6.0 or newer (which provides the so-called
32 ``KVM_CAP_S390_CPU_TOPOLOGY`` capability that allows QEMU to signal the
33 CPU topology facility via the so-called STFLE bit 11 to the VM).
35 Enabling CPU topology
36 ---------------------
38 Currently, CPU topology is enabled by default only in the "host" CPU model.
40 Enabling CPU topology in another CPU model is done by setting the CPU flag
41 ``ctop`` to ``on`` as in:
43 .. code-block:: bash
45    -cpu gen16b,ctop=on
47 Having the topology disabled by default allows migration between
48 old and new QEMU without adding new flags.
50 Default topology usage
51 ----------------------
53 The CPU topology can be specified on the QEMU command line
54 with the ``-smp`` or the ``-device`` QEMU command arguments.
56 Note also that since 7.2 threads are no longer supported in the topology
57 and the ``-smp`` command line argument accepts only ``threads=1``.
59 If none of the containers attributes (drawers, books, sockets) are
60 specified for the ``-smp`` flag, the number of these containers
61 is 1.
63 Thus the following two options will result in the same topology:
65 .. code-block:: bash
67     -smp cpus=5,drawer=1,books=1,sockets=8,cores=4,maxcpus=32
69 and
71 .. code-block:: bash
73     -smp cpus=5,sockets=8,cores=4,maxcpus=32
75 When a CPU is defined by the ``-smp`` command argument, its position
76 inside the topology is calculated by adding the CPUs to the topology
77 based on the core-id starting with core-0 at position 0 of socket-0,
78 book-0, drawer-0 and filling all CPUs of socket-0 before filling socket-1
79 of book-0 and so on up to the last socket of the last book of the last
80 drawer.
82 When a CPU is defined by the ``-device`` command argument, the
83 tree topology attributes must all be defined or all not defined.
85 .. code-block:: bash
87     -device gen16b-s390x-cpu,drawer-id=1,book-id=1,socket-id=2,core-id=1
91 .. code-block:: bash
93     -device gen16b-s390x-cpu,core-id=1,dedicated=true
95 If none of the tree attributes (drawer, book, sockets), are specified
96 for the ``-device`` argument, like for all CPUs defined with the ``-smp``
97 command argument the topology tree attributes will be set by simply
98 adding the CPUs to the topology based on the core-id.
100 QEMU will not try to resolve collisions and will report an error if the
101 CPU topology defined explicitly or implicitly on a ``-device``
102 argument collides with the definition of a CPU implicitly defined
103 on the ``-smp`` argument.
105 When the topology modifier attributes are not defined for the
106 ``-device`` command argument they takes following default values:
108 - dedicated: ``false``
109 - entitlement: ``medium``
112 Hot plug
113 ++++++++
115 New CPUs can be plugged using the device_add hmp command as in:
117 .. code-block:: bash
119   (qemu) device_add gen16b-s390x-cpu,core-id=9
121 The placement of the CPU is derived from the core-id as described above.
123 The topology can of course also be fully defined:
125 .. code-block:: bash
127     (qemu) device_add gen16b-s390x-cpu,drawer-id=1,book-id=1,socket-id=2,core-id=1
130 Examples
131 ++++++++
133 In the following machine we define 8 sockets with 4 cores each.
135 .. code-block:: bash
137   $ qemu-system-s390x -accel kvm -m 2G \
138     -cpu gen16b,ctop=on \
139     -smp cpus=5,sockets=8,cores=4,maxcpus=32 \
140     -device host-s390x-cpu,core-id=14 \
142 A new CPUs can be plugged using the device_add hmp command as before:
144 .. code-block:: bash
146   (qemu) device_add gen16b-s390x-cpu,core-id=9
148 The core-id defines the placement of the core in the topology by
149 starting with core 0 in socket 0 up to maxcpus.
151 In the example above:
153 * There are 5 CPUs provided to the guest with the ``-smp`` command line
154   They will take the core-ids 0,1,2,3,4
155   As we have 4 cores in a socket, we have 4 CPUs provided
156   to the guest in socket 0, with core-ids 0,1,2,3.
157   The last CPU, with core-id 4, will be on socket 1.
159 * the core with ID 14 provided by the ``-device`` command line will
160   be placed in socket 3, with core-id 14
162 * the core with ID 9 provided by the ``device_add`` qmp command will
163   be placed in socket 2, with core-id 9
166 Polarization, entitlement and dedication
167 ----------------------------------------
169 Polarization
170 ++++++++++++
172 The polarization affects how the CPUs of a shared host are utilized/distributed
173 among guests.
174 The guest determines the polarization by using the PTF instruction.
176 Polarization defines two models of CPU provisioning: horizontal
177 and vertical.
179 The horizontal polarization is the default model on boot and after
180 subsystem reset. When horizontal polarization is in effect all vCPUs should
181 have about equal resource provisioning.
183 In the vertical polarization model vCPUs are unequal, but overall more resources
184 might be available.
185 The guest can make use of the vCPU entitlement information provided by the host
186 to optimize kernel thread scheduling.
188 A subsystem reset puts all vCPU of the configuration into the
189 horizontal polarization.
191 Entitlement
192 +++++++++++
194 The vertical polarization specifies that the guest's vCPU can get
195 different real CPU provisioning:
197 - a vCPU with vertical high entitlement specifies that this
198   vCPU gets 100% of the real CPU provisioning.
200 - a vCPU with vertical medium entitlement specifies that this
201   vCPU shares the real CPU with other vCPUs.
203 - a vCPU with vertical low entitlement specifies that this
204   vCPU only gets real CPU provisioning when no other vCPUs needs it.
206 In the case a vCPU with vertical high entitlement does not use
207 the real CPU, the unused "slack" can be dispatched to other vCPU
208 with medium or low entitlement.
210 A vCPU can be "dedicated" in which case the vCPU is fully dedicated to a single
211 real CPU.
213 The dedicated bit is an indication of affinity of a vCPU for a real CPU
214 while the entitlement indicates the sharing or exclusivity of use.
216 Defining the topology on the command line
217 -----------------------------------------
219 The topology can entirely be defined using -device cpu statements,
220 with the exception of CPU 0 which must be defined with the -smp
221 argument.
223 For example, here we set the position of the cores 1,2,3 to
224 drawer 1, book 1, socket 2 and cores 0,9 and 14 to drawer 0,
225 book 0, socket 0 without defining entitlement or dedication.
226 Core 4 will be set on its default position on socket 1
227 (since we have 4 core per socket) and we define it as dedicated and
228 with vertical high entitlement.
230 .. code-block:: bash
232   $ qemu-system-s390x -accel kvm -m 2G \
233     -cpu gen16b,ctop=on \
234     -smp cpus=1,sockets=8,cores=4,maxcpus=32 \
235     \
236     -device gen16b-s390x-cpu,drawer-id=1,book-id=1,socket-id=2,core-id=1 \
237     -device gen16b-s390x-cpu,drawer-id=1,book-id=1,socket-id=2,core-id=2 \
238     -device gen16b-s390x-cpu,drawer-id=1,book-id=1,socket-id=2,core-id=3 \
239     \
240     -device gen16b-s390x-cpu,drawer-id=0,book-id=0,socket-id=0,core-id=9 \
241     -device gen16b-s390x-cpu,drawer-id=0,book-id=0,socket-id=0,core-id=14 \
242     \
243     -device gen16b-s390x-cpu,core-id=4,dedicated=on,entitlement=high
245 The entitlement defined for the CPU 4 will only be used after the guest
246 successfully enables vertical polarization by using the PTF instruction.