user-exec: handle synchronous signals from QEMU gracefully
[qemu/ar7.git] / docs / nvdimm.txt
blob2d9f8c0e8cfd1043df7fa8f8bf4076e38be3ca65
1 QEMU Virtual NVDIMM
2 ===================
4 This document explains the usage of virtual NVDIMM (vNVDIMM) feature
5 which is available since QEMU v2.6.0.
7 The current QEMU only implements the persistent memory mode of vNVDIMM
8 device and not the block window mode.
10 Basic Usage
11 -----------
13 The storage of a vNVDIMM device in QEMU is provided by the memory
14 backend (i.e. memory-backend-file and memory-backend-ram). A simple
15 way to create a vNVDIMM device at startup time is done via the
16 following command line options:
18  -machine pc,nvdimm
19  -m $RAM_SIZE,slots=$N,maxmem=$MAX_SIZE
20  -object memory-backend-file,id=mem1,share=on,mem-path=$PATH,size=$NVDIMM_SIZE
21  -device nvdimm,id=nvdimm1,memdev=mem1
23 Where,
25  - the "nvdimm" machine option enables vNVDIMM feature.
27  - "slots=$N" should be equal to or larger than the total amount of
28    normal RAM devices and vNVDIMM devices, e.g. $N should be >= 2 here.
30  - "maxmem=$MAX_SIZE" should be equal to or larger than the total size
31    of normal RAM devices and vNVDIMM devices, e.g. $MAX_SIZE should be
32    >= $RAM_SIZE + $NVDIMM_SIZE here.
34  - "object memory-backend-file,id=mem1,share=on,mem-path=$PATH,size=$NVDIMM_SIZE"
35    creates a backend storage of size $NVDIMM_SIZE on a file $PATH. All
36    accesses to the virtual NVDIMM device go to the file $PATH.
38    "share=on/off" controls the visibility of guest writes. If
39    "share=on", then guest writes will be applied to the backend
40    file. If another guest uses the same backend file with option
41    "share=on", then above writes will be visible to it as well. If
42    "share=off", then guest writes won't be applied to the backend
43    file and thus will be invisible to other guests.
45  - "device nvdimm,id=nvdimm1,memdev=mem1" creates a virtual NVDIMM
46    device whose storage is provided by above memory backend device.
48 Multiple vNVDIMM devices can be created if multiple pairs of "-object"
49 and "-device" are provided.
51 For above command line options, if the guest OS has the proper NVDIMM
52 driver, it should be able to detect a NVDIMM device which is in the
53 persistent memory mode and whose size is $NVDIMM_SIZE.
55 Note:
57 1. Prior to QEMU v2.8.0, if memory-backend-file is used and the actual
58    backend file size is not equal to the size given by "size" option,
59    QEMU will truncate the backend file by ftruncate(2), which will
60    corrupt the existing data in the backend file, especially for the
61    shrink case.
63    QEMU v2.8.0 and later check the backend file size and the "size"
64    option. If they do not match, QEMU will report errors and abort in
65    order to avoid the data corruption.
67 2. QEMU v2.6.0 only puts a basic alignment requirement on the "size"
68    option of memory-backend-file, e.g. 4KB alignment on x86.  However,
69    QEMU v.2.7.0 puts an additional alignment requirement, which may
70    require a larger value than the basic one, e.g. 2MB on x86. This
71    change breaks the usage of memory-backend-file that only satisfies
72    the basic alignment.
74    QEMU v2.8.0 and later remove the additional alignment on non-s390x
75    architectures, so the broken memory-backend-file can work again.
77 Label
78 -----
80 QEMU v2.7.0 and later implement the label support for vNVDIMM devices.
81 To enable label on vNVDIMM devices, users can simply add
82 "label-size=$SZ" option to "-device nvdimm", e.g.
84  -device nvdimm,id=nvdimm1,memdev=mem1,label-size=128K
86 Note:
88 1. The minimal label size is 128KB.
90 2. QEMU v2.7.0 and later store labels at the end of backend storage.
91    If a memory backend file, which was previously used as the backend
92    of a vNVDIMM device without labels, is now used for a vNVDIMM
93    device with label, the data in the label area at the end of file
94    will be inaccessible to the guest. If any useful data (e.g. the
95    meta-data of the file system) was stored there, the latter usage
96    may result guest data corruption (e.g. breakage of guest file
97    system).
99 Hotplug
100 -------
102 QEMU v2.8.0 and later implement the hotplug support for vNVDIMM
103 devices. Similarly to the RAM hotplug, the vNVDIMM hotplug is
104 accomplished by two monitor commands "object_add" and "device_add".
106 For example, the following commands add another 4GB vNVDIMM device to
107 the guest:
109  (qemu) object_add memory-backend-file,id=mem2,share=on,mem-path=new_nvdimm.img,size=4G
110  (qemu) device_add nvdimm,id=nvdimm2,memdev=mem2
112 Note:
114 1. Each hotplugged vNVDIMM device consumes one memory slot. Users
115    should always ensure the memory option "-m ...,slots=N" specifies
116    enough number of slots, i.e.
117      N >= number of RAM devices +
118           number of statically plugged vNVDIMM devices +
119           number of hotplugged vNVDIMM devices
121 2. The similar is required for the memory option "-m ...,maxmem=M", i.e.
122      M >= size of RAM devices +
123           size of statically plugged vNVDIMM devices +
124           size of hotplugged vNVDIMM devices