1 ------------------------------------------------------------------------------
3 -- GNAT COMPILER COMPONENTS --
9 -- Copyright (C) 1992-2009, Free Software Foundation, Inc. --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. --
18 -- As a special exception under Section 7 of GPL version 3, you are granted --
19 -- additional permissions described in the GCC Runtime Library Exception, --
20 -- version 3.1, as published by the Free Software Foundation. --
22 -- You should have received a copy of the GNU General Public License and --
23 -- a copy of the GCC Runtime Library Exception along with this program; --
24 -- see the files COPYING3 and COPYING.RUNTIME respectively. If not, see --
25 -- <http://www.gnu.org/licenses/>. --
27 -- GNAT was originally developed by the GNAT team at New York University. --
28 -- Extensive contributions were provided by Ada Core Technologies Inc. --
30 ------------------------------------------------------------------------------
32 pragma Style_Checks
(All_Checks
);
33 -- Subprogram ordering not enforced in this unit
34 -- (because of some logical groupings).
36 with Atree
; use Atree
;
37 with Einfo
; use Einfo
;
38 with Fname
; use Fname
;
39 with Output
; use Output
;
40 with Sinfo
; use Sinfo
;
41 with Sinput
; use Sinput
;
42 with Stand
; use Stand
;
43 with Stringt
; use Stringt
;
44 with Tree_IO
; use Tree_IO
;
45 with Uname
; use Uname
;
49 Switch_Storing_Enabled
: Boolean := True;
50 -- Controlled by Enable_Switch_Storing/Disable_Switch_Storing
52 -----------------------
53 -- Local Subprograms --
54 -----------------------
57 Yes_Before
, -- S1 is in same extended unit as S2 and appears before it
58 Yes_Same
, -- S1 is in same extended unit as S2, Slocs are the same
59 Yes_After
, -- S1 is in same extended unit as S2, and appears after it
60 No
); -- S2 is not in same extended unit as S2
62 function Check_Same_Extended_Unit
(S1
, S2
: Source_Ptr
) return SEU_Result
;
63 -- Used by In_Same_Extended_Unit and Earlier_In_Extended_Unit. Returns
64 -- value as described above.
66 function Get_Code_Or_Source_Unit
68 Unwind_Instances
: Boolean) return Unit_Number_Type
;
69 -- Common code for Get_Code_Unit (get unit of instantiation for location)
70 -- and Get_Source_Unit (get unit of template for location).
72 --------------------------------------------
73 -- Access Functions for Unit Table Fields --
74 --------------------------------------------
76 function Cunit
(U
: Unit_Number_Type
) return Node_Id
is
78 return Units
.Table
(U
).Cunit
;
81 function Cunit_Entity
(U
: Unit_Number_Type
) return Entity_Id
is
83 return Units
.Table
(U
).Cunit_Entity
;
86 function Dependency_Num
(U
: Unit_Number_Type
) return Nat
is
88 return Units
.Table
(U
).Dependency_Num
;
91 function Dynamic_Elab
(U
: Unit_Number_Type
) return Boolean is
93 return Units
.Table
(U
).Dynamic_Elab
;
96 function Error_Location
(U
: Unit_Number_Type
) return Source_Ptr
is
98 return Units
.Table
(U
).Error_Location
;
101 function Expected_Unit
(U
: Unit_Number_Type
) return Unit_Name_Type
is
103 return Units
.Table
(U
).Expected_Unit
;
106 function Fatal_Error
(U
: Unit_Number_Type
) return Boolean is
108 return Units
.Table
(U
).Fatal_Error
;
111 function Generate_Code
(U
: Unit_Number_Type
) return Boolean is
113 return Units
.Table
(U
).Generate_Code
;
116 function Has_RACW
(U
: Unit_Number_Type
) return Boolean is
118 return Units
.Table
(U
).Has_RACW
;
121 function Is_Compiler_Unit
(U
: Unit_Number_Type
) return Boolean is
123 return Units
.Table
(U
).Is_Compiler_Unit
;
124 end Is_Compiler_Unit
;
126 function Ident_String
(U
: Unit_Number_Type
) return Node_Id
is
128 return Units
.Table
(U
).Ident_String
;
131 function Loading
(U
: Unit_Number_Type
) return Boolean is
133 return Units
.Table
(U
).Loading
;
136 function Main_Priority
(U
: Unit_Number_Type
) return Int
is
138 return Units
.Table
(U
).Main_Priority
;
141 function Munit_Index
(U
: Unit_Number_Type
) return Nat
is
143 return Units
.Table
(U
).Munit_Index
;
146 function OA_Setting
(U
: Unit_Number_Type
) return Character is
148 return Units
.Table
(U
).OA_Setting
;
151 function Source_Index
(U
: Unit_Number_Type
) return Source_File_Index
is
153 return Units
.Table
(U
).Source_Index
;
156 function Unit_File_Name
(U
: Unit_Number_Type
) return File_Name_Type
is
158 return Units
.Table
(U
).Unit_File_Name
;
161 function Unit_Name
(U
: Unit_Number_Type
) return Unit_Name_Type
is
163 return Units
.Table
(U
).Unit_Name
;
166 ------------------------------------------
167 -- Subprograms to Set Unit Table Fields --
168 ------------------------------------------
170 procedure Set_Cunit
(U
: Unit_Number_Type
; N
: Node_Id
) is
172 Units
.Table
(U
).Cunit
:= N
;
175 procedure Set_Cunit_Entity
(U
: Unit_Number_Type
; E
: Entity_Id
) is
177 Units
.Table
(U
).Cunit_Entity
:= E
;
178 Set_Is_Compilation_Unit
(E
);
179 end Set_Cunit_Entity
;
181 procedure Set_Dynamic_Elab
(U
: Unit_Number_Type
; B
: Boolean := True) is
183 Units
.Table
(U
).Dynamic_Elab
:= B
;
184 end Set_Dynamic_Elab
;
186 procedure Set_Error_Location
(U
: Unit_Number_Type
; W
: Source_Ptr
) is
188 Units
.Table
(U
).Error_Location
:= W
;
189 end Set_Error_Location
;
191 procedure Set_Fatal_Error
(U
: Unit_Number_Type
; B
: Boolean := True) is
193 Units
.Table
(U
).Fatal_Error
:= B
;
196 procedure Set_Generate_Code
(U
: Unit_Number_Type
; B
: Boolean := True) is
198 Units
.Table
(U
).Generate_Code
:= B
;
199 end Set_Generate_Code
;
201 procedure Set_Has_RACW
(U
: Unit_Number_Type
; B
: Boolean := True) is
203 Units
.Table
(U
).Has_RACW
:= B
;
206 procedure Set_Is_Compiler_Unit
207 (U
: Unit_Number_Type
;
211 Units
.Table
(U
).Is_Compiler_Unit
:= B
;
212 end Set_Is_Compiler_Unit
;
214 procedure Set_Ident_String
(U
: Unit_Number_Type
; N
: Node_Id
) is
216 Units
.Table
(U
).Ident_String
:= N
;
217 end Set_Ident_String
;
219 procedure Set_Loading
(U
: Unit_Number_Type
; B
: Boolean := True) is
221 Units
.Table
(U
).Loading
:= B
;
224 procedure Set_Main_Priority
(U
: Unit_Number_Type
; P
: Int
) is
226 Units
.Table
(U
).Main_Priority
:= P
;
227 end Set_Main_Priority
;
229 procedure Set_OA_Setting
(U
: Unit_Number_Type
; C
: Character) is
231 Units
.Table
(U
).OA_Setting
:= C
;
234 procedure Set_Unit_Name
(U
: Unit_Number_Type
; N
: Unit_Name_Type
) is
236 Units
.Table
(U
).Unit_Name
:= N
;
239 ------------------------------
240 -- Check_Same_Extended_Unit --
241 ------------------------------
243 function Check_Same_Extended_Unit
(S1
, S2
: Source_Ptr
) return SEU_Result
is
246 Sind1
: Source_File_Index
;
247 Sind2
: Source_File_Index
;
250 Unum1
: Unit_Number_Type
;
251 Unum2
: Unit_Number_Type
;
258 if S1
= No_Location
or else S2
= No_Location
then
261 elsif S1
= Standard_Location
then
262 if S2
= Standard_Location
then
268 elsif S2
= Standard_Location
then
274 Unum1
:= Get_Code_Unit
(Sloc1
);
275 Unum2
:= Get_Code_Unit
(Sloc2
);
278 Sind1
:= Get_Source_File_Index
(Sloc1
);
279 Sind2
:= Get_Source_File_Index
(Sloc2
);
281 if Sind1
= Sind2
then
282 if Sloc1
< Sloc2
then
284 elsif Sloc1
> Sloc2
then
291 -- OK, the two nodes are in separate source elements, but this is not
292 -- decisive, because of the issue of subunits and instantiations.
294 -- First we deal with subunits, since if the subunit is in an
295 -- instantiation, we know that the parent is in the corresponding
296 -- instantiation, since that is the only way we can have a subunit
297 -- that is part of an instantiation.
299 Unit1
:= Unit
(Cunit
(Unum1
));
300 Unit2
:= Unit
(Cunit
(Unum2
));
302 if Nkind
(Unit1
) = N_Subunit
303 and then Present
(Corresponding_Stub
(Unit1
))
305 -- Both in subunits. They could have a common ancestor. If they
306 -- do, then the deeper one must have a longer unit name. Replace
307 -- the deeper one with its corresponding stub, in order to find
308 -- nearest common ancestor, if any.
310 if Nkind
(Unit2
) = N_Subunit
311 and then Present
(Corresponding_Stub
(Unit2
))
313 if Length_Of_Name
(Unit_Name
(Unum1
)) <
314 Length_Of_Name
(Unit_Name
(Unum2
))
316 Sloc2
:= Sloc
(Corresponding_Stub
(Unit2
));
317 Unum2
:= Get_Source_Unit
(Sloc2
);
321 Sloc1
:= Sloc
(Corresponding_Stub
(Unit1
));
322 Unum1
:= Get_Source_Unit
(Sloc1
);
326 -- Nod1 in subunit, Nod2 not
329 Sloc1
:= Sloc
(Corresponding_Stub
(Unit1
));
330 Unum1
:= Get_Source_Unit
(Sloc1
);
334 -- Nod2 in subunit, Nod1 not
336 elsif Nkind
(Unit2
) = N_Subunit
337 and then Present
(Corresponding_Stub
(Unit2
))
339 Sloc2
:= Sloc
(Corresponding_Stub
(Unit2
));
340 Unum2
:= Get_Source_Unit
(Sloc2
);
344 -- At this stage we know that neither is a subunit, so we deal
345 -- with instantiations, since we could have a common ancestor
347 Inst1
:= Instantiation
(Sind1
);
348 Inst2
:= Instantiation
(Sind2
);
350 if Inst1
/= No_Location
then
352 -- Both are instantiations
354 if Inst2
/= No_Location
then
356 Depth1
:= Instantiation_Depth
(Sloc1
);
357 Depth2
:= Instantiation_Depth
(Sloc2
);
359 if Depth1
< Depth2
then
361 Unum2
:= Get_Source_Unit
(Sloc2
);
364 elsif Depth1
> Depth2
then
366 Unum1
:= Get_Source_Unit
(Sloc1
);
372 Unum1
:= Get_Source_Unit
(Sloc1
);
373 Unum2
:= Get_Source_Unit
(Sloc2
);
377 -- Only first node is in instantiation
381 Unum1
:= Get_Source_Unit
(Sloc1
);
385 -- Only second node is instantiation
387 elsif Inst2
/= No_Location
then
389 Unum2
:= Get_Source_Unit
(Sloc2
);
393 -- No instantiations involved, so we are not in the same unit
394 -- However, there is one case still to check, namely the case
395 -- where one location is in the spec, and the other in the
396 -- corresponding body (the spec location is earlier).
398 if Nkind
(Unit1
) = N_Subprogram_Body
400 Nkind
(Unit1
) = N_Package_Body
402 if Library_Unit
(Cunit
(Unum1
)) = Cunit
(Unum2
) then
406 elsif Nkind
(Unit2
) = N_Subprogram_Body
408 Nkind
(Unit2
) = N_Package_Body
410 if Library_Unit
(Cunit
(Unum2
)) = Cunit
(Unum1
) then
415 -- If that special case does not occur, then we are certain that
416 -- the two locations are really in separate units.
423 end Check_Same_Extended_Unit
;
425 -------------------------------
426 -- Compilation_Switches_Last --
427 -------------------------------
429 function Compilation_Switches_Last
return Nat
is
431 return Compilation_Switches
.Last
;
432 end Compilation_Switches_Last
;
434 ---------------------------
435 -- Enable_Switch_Storing --
436 ---------------------------
438 procedure Enable_Switch_Storing
is
440 Switch_Storing_Enabled
:= True;
441 end Enable_Switch_Storing
;
443 ----------------------------
444 -- Disable_Switch_Storing --
445 ----------------------------
447 procedure Disable_Switch_Storing
is
449 Switch_Storing_Enabled
:= False;
450 end Disable_Switch_Storing
;
452 ------------------------------
453 -- Earlier_In_Extended_Unit --
454 ------------------------------
456 function Earlier_In_Extended_Unit
(S1
, S2
: Source_Ptr
) return Boolean is
458 return Check_Same_Extended_Unit
(S1
, S2
) = Yes_Before
;
459 end Earlier_In_Extended_Unit
;
461 ----------------------------
462 -- Entity_Is_In_Main_Unit --
463 ----------------------------
465 function Entity_Is_In_Main_Unit
(E
: Entity_Id
) return Boolean is
471 while S
/= Standard_Standard
loop
472 if S
= Main_Unit_Entity
then
474 elsif Ekind
(S
) = E_Package
and then Is_Child_Unit
(S
) then
482 end Entity_Is_In_Main_Unit
;
484 --------------------------
485 -- Generic_May_Lack_ALI --
486 --------------------------
488 function Generic_May_Lack_ALI
(Sfile
: File_Name_Type
) return Boolean is
490 -- We allow internal generic units to be used without having a
491 -- corresponding ALI files to help bootstrapping with older compilers
492 -- that did not support generating ALIs for such generics. It is safe
493 -- to do so because the only thing the generated code would contain
494 -- is the elaboration boolean, and we are careful to elaborate all
495 -- predefined units first anyway.
497 return Is_Internal_File_Name
499 Renamings_Included
=> True);
500 end Generic_May_Lack_ALI
;
502 -----------------------------
503 -- Get_Code_Or_Source_Unit --
504 -----------------------------
506 function Get_Code_Or_Source_Unit
508 Unwind_Instances
: Boolean) return Unit_Number_Type
511 -- Search table unless we have No_Location, which can happen if the
512 -- relevant location has not been set yet. Happens for example when
513 -- we obtain Sloc (Cunit (Main_Unit)) before it is set.
515 if S
/= No_Location
then
517 Source_File
: Source_File_Index
;
518 Source_Unit
: Unit_Number_Type
;
521 Source_File
:= Get_Source_File_Index
(S
);
523 if Unwind_Instances
then
524 while Template
(Source_File
) /= No_Source_File
loop
525 Source_File
:= Template
(Source_File
);
529 Source_Unit
:= Unit
(Source_File
);
531 if Source_Unit
/= No_Unit
then
537 -- If S was No_Location, or was not in the table, we must be in the main
538 -- source unit (and the value has not been placed in the table yet),
539 -- or in one of the configuration pragma files.
542 end Get_Code_Or_Source_Unit
;
548 function Get_Code_Unit
(S
: Source_Ptr
) return Unit_Number_Type
is
550 return Get_Code_Or_Source_Unit
(Top_Level_Location
(S
),
551 Unwind_Instances
=> False);
554 function Get_Code_Unit
(N
: Node_Or_Entity_Id
) return Unit_Number_Type
is
556 return Get_Code_Unit
(Sloc
(N
));
559 ----------------------------
560 -- Get_Compilation_Switch --
561 ----------------------------
563 function Get_Compilation_Switch
(N
: Pos
) return String_Ptr
is
565 if N
<= Compilation_Switches
.Last
then
566 return Compilation_Switches
.Table
(N
);
571 end Get_Compilation_Switch
;
573 ----------------------------------
574 -- Get_Cunit_Entity_Unit_Number --
575 ----------------------------------
577 function Get_Cunit_Entity_Unit_Number
578 (E
: Entity_Id
) return Unit_Number_Type
581 for U
in Units
.First
.. Units
.Last
loop
582 if Cunit_Entity
(U
) = E
then
587 -- If not in the table, must be the main source unit, and we just
588 -- have not got it put into the table yet.
591 end Get_Cunit_Entity_Unit_Number
;
593 ---------------------------
594 -- Get_Cunit_Unit_Number --
595 ---------------------------
597 function Get_Cunit_Unit_Number
(N
: Node_Id
) return Unit_Number_Type
is
599 for U
in Units
.First
.. Units
.Last
loop
600 if Cunit
(U
) = N
then
605 -- If not in the table, must be a spec created for a main unit that is a
606 -- child subprogram body which we have not inserted into the table yet.
608 if N
= Library_Unit
(Cunit
(Main_Unit
)) then
611 -- If it is anything else, something is seriously wrong, and we really
612 -- don't want to proceed, even if assertions are off, so we explicitly
613 -- raise an exception in this case to terminate compilation.
618 end Get_Cunit_Unit_Number
;
620 ---------------------
621 -- Get_Source_Unit --
622 ---------------------
624 function Get_Source_Unit
(S
: Source_Ptr
) return Unit_Number_Type
is
626 return Get_Code_Or_Source_Unit
(S
, Unwind_Instances
=> True);
629 function Get_Source_Unit
(N
: Node_Or_Entity_Id
) return Unit_Number_Type
is
631 return Get_Source_Unit
(Sloc
(N
));
634 --------------------------------
635 -- In_Extended_Main_Code_Unit --
636 --------------------------------
638 function In_Extended_Main_Code_Unit
639 (N
: Node_Or_Entity_Id
) return Boolean
642 if Sloc
(N
) = Standard_Location
then
645 elsif Sloc
(N
) = No_Location
then
648 -- Special case Itypes to test the Sloc of the associated node. The
649 -- reason we do this is for possible calls from gigi after -gnatD
650 -- processing is complete in sprint. This processing updates the
651 -- sloc fields of all nodes in the tree, but itypes are not in the
652 -- tree so their slocs do not get updated.
654 elsif Nkind
(N
) = N_Defining_Identifier
655 and then Is_Itype
(N
)
657 return In_Extended_Main_Code_Unit
(Associated_Node_For_Itype
(N
));
659 -- Otherwise see if we are in the main unit
661 elsif Get_Code_Unit
(Sloc
(N
)) = Get_Code_Unit
(Cunit
(Main_Unit
)) then
664 -- Node may be in spec (or subunit etc) of main unit
668 In_Same_Extended_Unit
(N
, Cunit
(Main_Unit
));
670 end In_Extended_Main_Code_Unit
;
672 function In_Extended_Main_Code_Unit
(Loc
: Source_Ptr
) return Boolean is
674 if Loc
= Standard_Location
then
677 elsif Loc
= No_Location
then
680 -- Otherwise see if we are in the main unit
682 elsif Get_Code_Unit
(Loc
) = Get_Code_Unit
(Cunit
(Main_Unit
)) then
685 -- Location may be in spec (or subunit etc) of main unit
689 In_Same_Extended_Unit
(Loc
, Sloc
(Cunit
(Main_Unit
)));
691 end In_Extended_Main_Code_Unit
;
693 ----------------------------------
694 -- In_Extended_Main_Source_Unit --
695 ----------------------------------
697 function In_Extended_Main_Source_Unit
698 (N
: Node_Or_Entity_Id
) return Boolean
700 Nloc
: constant Source_Ptr
:= Sloc
(N
);
701 Mloc
: constant Source_Ptr
:= Sloc
(Cunit
(Main_Unit
));
704 -- If Mloc is not set, it means we are still parsing the main unit,
705 -- so everything so far is in the extended main source unit.
707 if Mloc
= No_Location
then
710 -- Special value cases
712 elsif Nloc
= Standard_Location
then
715 elsif Nloc
= No_Location
then
718 -- Special case Itypes to test the Sloc of the associated node. The
719 -- reason we do this is for possible calls from gigi after -gnatD
720 -- processing is complete in sprint. This processing updates the
721 -- sloc fields of all nodes in the tree, but itypes are not in the
722 -- tree so their slocs do not get updated.
724 elsif Nkind
(N
) = N_Defining_Identifier
725 and then Is_Itype
(N
)
727 return In_Extended_Main_Source_Unit
(Associated_Node_For_Itype
(N
));
729 -- Otherwise compare original locations to see if in same unit
733 In_Same_Extended_Unit
734 (Original_Location
(Nloc
), Original_Location
(Mloc
));
736 end In_Extended_Main_Source_Unit
;
738 function In_Extended_Main_Source_Unit
739 (Loc
: Source_Ptr
) return Boolean
741 Mloc
: constant Source_Ptr
:= Sloc
(Cunit
(Main_Unit
));
744 -- If Mloc is not set, it means we are still parsing the main unit,
745 -- so everything so far is in the extended main source unit.
747 if Mloc
= No_Location
then
750 -- Special value cases
752 elsif Loc
= Standard_Location
then
755 elsif Loc
= No_Location
then
758 -- Otherwise compare original locations to see if in same unit
762 In_Same_Extended_Unit
763 (Original_Location
(Loc
), Original_Location
(Mloc
));
765 end In_Extended_Main_Source_Unit
;
767 ------------------------
768 -- In_Predefined_Unit --
769 ------------------------
771 function In_Predefined_Unit
(N
: Node_Or_Entity_Id
) return Boolean is
773 return In_Predefined_Unit
(Sloc
(N
));
774 end In_Predefined_Unit
;
776 function In_Predefined_Unit
(S
: Source_Ptr
) return Boolean is
777 Unit
: constant Unit_Number_Type
:= Get_Source_Unit
(S
);
778 File
: constant File_Name_Type
:= Unit_File_Name
(Unit
);
780 return Is_Predefined_File_Name
(File
);
781 end In_Predefined_Unit
;
783 -----------------------
784 -- In_Same_Code_Unit --
785 -----------------------
787 function In_Same_Code_Unit
(N1
, N2
: Node_Or_Entity_Id
) return Boolean is
788 S1
: constant Source_Ptr
:= Sloc
(N1
);
789 S2
: constant Source_Ptr
:= Sloc
(N2
);
792 if S1
= No_Location
or else S2
= No_Location
then
795 elsif S1
= Standard_Location
then
796 return S2
= Standard_Location
;
798 elsif S2
= Standard_Location
then
802 return Get_Code_Unit
(N1
) = Get_Code_Unit
(N2
);
803 end In_Same_Code_Unit
;
805 ---------------------------
806 -- In_Same_Extended_Unit --
807 ---------------------------
809 function In_Same_Extended_Unit
810 (N1
, N2
: Node_Or_Entity_Id
) return Boolean
813 return Check_Same_Extended_Unit
(Sloc
(N1
), Sloc
(N2
)) /= No
;
814 end In_Same_Extended_Unit
;
816 function In_Same_Extended_Unit
(S1
, S2
: Source_Ptr
) return Boolean is
818 return Check_Same_Extended_Unit
(S1
, S2
) /= No
;
819 end In_Same_Extended_Unit
;
821 -------------------------
822 -- In_Same_Source_Unit --
823 -------------------------
825 function In_Same_Source_Unit
(N1
, N2
: Node_Or_Entity_Id
) return Boolean is
826 S1
: constant Source_Ptr
:= Sloc
(N1
);
827 S2
: constant Source_Ptr
:= Sloc
(N2
);
830 if S1
= No_Location
or else S2
= No_Location
then
833 elsif S1
= Standard_Location
then
834 return S2
= Standard_Location
;
836 elsif S2
= Standard_Location
then
840 return Get_Source_Unit
(N1
) = Get_Source_Unit
(N2
);
841 end In_Same_Source_Unit
;
843 -----------------------------
844 -- Increment_Serial_Number --
845 -----------------------------
847 function Increment_Serial_Number
return Nat
is
848 TSN
: Int
renames Units
.Table
(Current_Sem_Unit
).Serial_Number
;
852 end Increment_Serial_Number
;
858 procedure Initialize
is
860 Linker_Option_Lines
.Init
;
863 Compilation_Switches
.Init
;
870 function Is_Loaded
(Uname
: Unit_Name_Type
) return Boolean is
872 for Unum
in Units
.First
.. Units
.Last
loop
873 if Uname
= Unit_Name
(Unum
) then
885 function Last_Unit
return Unit_Number_Type
is
894 procedure List
(File_Names_Only
: Boolean := False) is separate;
902 Linker_Option_Lines
.Locked
:= True;
903 Load_Stack
.Locked
:= True;
904 Units
.Locked
:= True;
905 Linker_Option_Lines
.Release
;
914 function Num_Units
return Nat
is
916 return Int
(Units
.Last
) - Int
(Main_Unit
) + 1;
923 procedure Remove_Unit
(U
: Unit_Number_Type
) is
925 if U
= Units
.Last
then
926 Units
.Decrement_Last
;
930 ----------------------------------
931 -- Replace_Linker_Option_String --
932 ----------------------------------
934 procedure Replace_Linker_Option_String
935 (S
: String_Id
; Match_String
: String)
938 if Match_String
'Length > 0 then
939 for J
in 1 .. Linker_Option_Lines
.Last
loop
940 String_To_Name_Buffer
(Linker_Option_Lines
.Table
(J
).Option
);
942 if Match_String
= Name_Buffer
(1 .. Match_String
'Length) then
943 Linker_Option_Lines
.Table
(J
).Option
:= S
;
949 Store_Linker_Option_String
(S
);
950 end Replace_Linker_Option_String
;
956 procedure Sort
(Tbl
: in out Unit_Ref_Table
) is separate;
958 ------------------------------
959 -- Store_Compilation_Switch --
960 ------------------------------
962 procedure Store_Compilation_Switch
(Switch
: String) is
964 if Switch_Storing_Enabled
then
965 Compilation_Switches
.Increment_Last
;
966 Compilation_Switches
.Table
(Compilation_Switches
.Last
) :=
969 -- Fix up --RTS flag which has been transformed by the gcc driver
972 if Switch'Last >= Switch'First + 4
973 and then Switch (Switch'First .. Switch'First + 4) = "-fRTS"
975 Compilation_Switches.Table
976 (Compilation_Switches.Last) (Switch'First + 1) := '-';
979 end Store_Compilation_Switch;
981 --------------------------------
982 -- Store_Linker_Option_String --
983 --------------------------------
985 procedure Store_Linker_Option_String (S : String_Id) is
987 Linker_Option_Lines.Increment_Last;
988 Linker_Option_Lines.Table (Linker_Option_Lines.Last) :=
989 (Option => S, Unit => Current_Sem_Unit);
990 end Store_Linker_Option_String;
992 -------------------------------
993 -- Synchronize_Serial_Number --
994 -------------------------------
996 procedure Synchronize_Serial_Number is
997 TSN : Int renames Units.Table (Current_Sem_Unit).Serial_Number;
1000 end Synchronize_Serial_Number;
1006 procedure Tree_Read is
1013 -- Read Compilation_Switches table. First release the memory occupied
1014 -- by the previously loaded switches.
1016 for J in Compilation_Switches.First .. Compilation_Switches.Last loop
1017 Free (Compilation_Switches.Table (J));
1021 Compilation_Switches.Set_Last (N);
1023 for J in 1 .. N loop
1025 Compilation_Switches.Table (J) := S;
1033 procedure Tree_Write is
1037 -- Write Compilation_Switches table
1039 Tree_Write_Int (Compilation_Switches.Last);
1041 for J in 1 .. Compilation_Switches.Last loop
1042 Tree_Write_Str (Compilation_Switches.Table (J));
1052 Linker_Option_Lines.Locked := False;
1053 Load_Stack.Locked := False;
1054 Units.Locked := False;
1061 function Version_Get (U : Unit_Number_Type) return Word_Hex_String is
1063 return Get_Hex_String (Units.Table (U).Version);
1066 ------------------------
1067 -- Version_Referenced --
1068 ------------------------
1070 procedure Version_Referenced (S : String_Id) is
1072 Version_Ref.Append (S);
1073 end Version_Referenced;