[testsuite]
[official-gcc.git] / gcc / ada / libgnat / s-parint.ads
blobc29de79ab1aaac71ffb3a40449eef056a6a3eb9d
1 ------------------------------------------------------------------------------
2 -- --
3 -- GNAT RUN-TIME COMPONENTS --
4 -- --
5 -- S Y S T E M . P A R T I T I O N _ I N T E R F A C E --
6 -- --
7 -- S p e c --
8 -- --
9 -- Copyright (C) 1995-2018, Free Software Foundation, Inc. --
10 -- --
11 -- GNARL is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. --
17 -- --
18 -- As a special exception under Section 7 of GPL version 3, you are granted --
19 -- additional permissions described in the GCC Runtime Library Exception, --
20 -- version 3.1, as published by the Free Software Foundation. --
21 -- --
22 -- You should have received a copy of the GNU General Public License and --
23 -- a copy of the GCC Runtime Library Exception along with this program; --
24 -- see the files COPYING3 and COPYING.RUNTIME respectively. If not, see --
25 -- <http://www.gnu.org/licenses/>. --
26 -- --
27 -- GNAT was originally developed by the GNAT team at New York University. --
28 -- Extensive contributions were provided by Ada Core Technologies Inc. --
29 -- --
30 ------------------------------------------------------------------------------
32 -- This unit may be used directly from an application program by providing
33 -- an appropriate WITH, and the interface can be expected to remain stable.
35 with Ada.Exceptions;
36 with Ada.Streams;
37 with Interfaces;
38 with System.RPC;
40 package System.Partition_Interface is
41 pragma Elaborate_Body;
43 type DSA_Implementation_Name is (No_DSA, GARLIC_DSA, PolyORB_DSA);
44 DSA_Implementation : constant DSA_Implementation_Name := No_DSA;
45 -- Identification of this DSA implementation variant
47 PCS_Version : constant := 1;
48 -- Version of the PCS API (for Exp_Dist consistency check)
50 -- This version number is matched against corresponding element of
51 -- Exp_Dist.PCS_Version_Number to ensure that the versions of Exp_Dist
52 -- and the PCS are consistent.
54 -- RCI receiving stubs contain a table of descriptors for all user
55 -- subprograms exported by the unit.
57 type Subprogram_Id is new Natural;
58 First_RCI_Subprogram_Id : constant := 2;
60 type RCI_Subp_Info is record
61 Addr : System.Address;
62 -- Local address of the proxy object
63 end record;
65 type RCI_Subp_Info_Access is access all RCI_Subp_Info;
66 type RCI_Subp_Info_Array is array (Integer range <>) of
67 aliased RCI_Subp_Info;
69 subtype Unit_Name is String;
70 -- Name of Ada units
72 type Main_Subprogram_Type is access procedure;
74 type RACW_Stub_Type is tagged record
75 Origin : RPC.Partition_ID;
76 Receiver : Interfaces.Unsigned_64;
77 Addr : Interfaces.Unsigned_64;
78 Asynchronous : Boolean;
79 end record;
81 type RACW_Stub_Type_Access is access RACW_Stub_Type;
82 -- This type is used by the expansion to implement distributed objects.
83 -- Do not change its definition or its layout without updating
84 -- exp_dist.adb.
86 type RAS_Proxy_Type is tagged limited record
87 All_Calls_Remote : Boolean;
88 Receiver : System.Address;
89 Subp_Id : Subprogram_Id;
90 end record;
92 type RAS_Proxy_Type_Access is access RAS_Proxy_Type;
93 pragma No_Strict_Aliasing (RAS_Proxy_Type_Access);
94 -- This type is used by the expansion to implement distributed objects.
95 -- Do not change its definition or its layout without updating
96 -- Exp_Dist.Build_Remote_Subprogram_Proxy_Type.
98 -- The Request_Access type is used for communication between the PCS
99 -- and the RPC receiver generated by the compiler: it contains all the
100 -- necessary information for the receiver to process an incoming call.
102 type RST_Access is access all Ada.Streams.Root_Stream_Type'Class;
103 type Request_Access is record
104 Params : RST_Access;
105 -- A stream describing the called subprogram and its parameters
107 Result : RST_Access;
108 -- A stream where the result, raised exception, or out values,
109 -- are marshalled.
110 end record;
112 procedure Check
113 (Name : Unit_Name;
114 Version : String;
115 RCI : Boolean := True);
116 -- Use by the main subprogram to check that a remote receiver
117 -- unit has the same version than the caller's one.
119 function Same_Partition
120 (Left : not null access RACW_Stub_Type;
121 Right : not null access RACW_Stub_Type) return Boolean;
122 -- Determine whether Left and Right correspond to objects instantiated
123 -- on the same partition, for enforcement of E.4(19).
125 function Get_Active_Partition_ID (Name : Unit_Name) return RPC.Partition_ID;
126 -- Similar in some respects to RCI_Locator.Get_Active_Partition_ID
128 function Get_Active_Version (Name : Unit_Name) return String;
129 -- Similar in some respects to Get_Active_Partition_ID
131 function Get_Local_Partition_ID return RPC.Partition_ID;
132 -- Return the Partition_ID of the current partition
134 function Get_Passive_Partition_ID
135 (Name : Unit_Name) return RPC.Partition_ID;
136 -- Return the Partition_ID of the given shared passive partition
138 function Get_Passive_Version (Name : Unit_Name) return String;
139 -- Return the version corresponding to a shared passive unit
141 function Get_RCI_Package_Receiver
142 (Name : Unit_Name) return Interfaces.Unsigned_64;
143 -- Similar in some respects to RCI_Locator.Get_RCI_Package_Receiver
145 procedure Get_Unique_Remote_Pointer
146 (Handler : in out RACW_Stub_Type_Access);
147 -- Get a unique pointer on a remote object
149 procedure Raise_Program_Error_Unknown_Tag
150 (E : Ada.Exceptions.Exception_Occurrence);
151 pragma No_Return (Raise_Program_Error_Unknown_Tag);
152 -- Raise Program_Error with the same message as E one
154 type RPC_Receiver is access procedure (R : Request_Access);
155 procedure Register_Receiving_Stub
156 (Name : Unit_Name;
157 Receiver : RPC_Receiver;
158 Version : String := "";
159 Subp_Info : System.Address;
160 Subp_Info_Len : Integer);
161 -- Register the fact that the Name receiving stub is now elaborated.
162 -- Register the access value to the package RPC_Receiver procedure.
164 procedure Get_RAS_Info
165 (Name : Unit_Name;
166 Subp_Id : Subprogram_Id;
167 Proxy_Address : out Interfaces.Unsigned_64);
168 -- Look up the address of the proxy object for the given subprogram
169 -- in the named unit, or Null_Address if not present on the local
170 -- partition.
172 procedure Register_Passive_Package
173 (Name : Unit_Name;
174 Version : String := "");
175 -- Register a passive package
177 generic
178 RCI_Name : String;
179 Version : String;
180 package RCI_Locator is
181 pragma Unreferenced (Version);
183 function Get_RCI_Package_Receiver return Interfaces.Unsigned_64;
184 function Get_Active_Partition_ID return RPC.Partition_ID;
185 end RCI_Locator;
186 -- RCI package information caching
188 procedure Run (Main : Main_Subprogram_Type := null);
189 -- Run the main subprogram
191 end System.Partition_Interface;