1 ------------------------------------------------------------------------------
3 -- GNAT COMPILER COMPONENTS --
9 -- Copyright (C) 1997-2015, Free Software Foundation, Inc. --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License --
17 -- for more details. You should have received a copy of the GNU General --
18 -- Public License distributed with GNAT; see file COPYING3. If not, go to --
19 -- http://www.gnu.org/licenses for a complete copy of the license. --
21 -- GNAT was originally developed by the GNAT team at New York University. --
22 -- Extensive contributions were provided by Ada Core Technologies Inc. --
24 ------------------------------------------------------------------------------
26 with Atree
; use Atree
;
27 with Checks
; use Checks
;
28 with Debug
; use Debug
;
29 with Einfo
; use Einfo
;
30 with Elists
; use Elists
;
31 with Errout
; use Errout
;
32 with Exp_Tss
; use Exp_Tss
;
33 with Exp_Util
; use Exp_Util
;
34 with Expander
; use Expander
;
35 with Fname
; use Fname
;
37 with Lib
.Load
; use Lib
.Load
;
38 with Namet
; use Namet
;
39 with Nlists
; use Nlists
;
40 with Nmake
; use Nmake
;
42 with Output
; use Output
;
43 with Restrict
; use Restrict
;
44 with Rident
; use Rident
;
46 with Sem_Aux
; use Sem_Aux
;
47 with Sem_Cat
; use Sem_Cat
;
48 with Sem_Ch7
; use Sem_Ch7
;
49 with Sem_Ch8
; use Sem_Ch8
;
50 with Sem_Util
; use Sem_Util
;
51 with Sinfo
; use Sinfo
;
52 with Sinput
; use Sinput
;
53 with Snames
; use Snames
;
54 with Stand
; use Stand
;
56 with Tbuild
; use Tbuild
;
57 with Uintp
; use Uintp
;
58 with Uname
; use Uname
;
60 package body Sem_Elab
is
62 -- The following table records the recursive call chain for output in the
63 -- Output routine. Each entry records the call node and the entity of the
64 -- called routine. The number of entries in the table (i.e. the value of
65 -- Elab_Call.Last) indicates the current depth of recursion and is used to
66 -- identify the outer level.
68 type Elab_Call_Entry
is record
73 package Elab_Call
is new Table
.Table
(
74 Table_Component_Type
=> Elab_Call_Entry
,
75 Table_Index_Type
=> Int
,
78 Table_Increment
=> 100,
79 Table_Name
=> "Elab_Call");
81 -- This table is initialized at the start of each outer level call. It
82 -- holds the entities for all subprograms that have been examined for this
83 -- particular outer level call, and is used to prevent both infinite
84 -- recursion, and useless reanalysis of bodies already seen
86 package Elab_Visited
is new Table
.Table
(
87 Table_Component_Type
=> Entity_Id
,
88 Table_Index_Type
=> Int
,
91 Table_Increment
=> 100,
92 Table_Name
=> "Elab_Visited");
94 -- This table stores calls to Check_Internal_Call that are delayed
95 -- until all generics are instantiated, and in particular that all
96 -- generic bodies have been inserted. We need to delay, because we
97 -- need to be able to look through the inserted bodies.
99 type Delay_Element
is record
101 -- The parameter N from the call to Check_Internal_Call. Note that
102 -- this node may get rewritten over the delay period by expansion
103 -- in the call case (but not in the instantiation case).
106 -- The parameter E from the call to Check_Internal_Call
108 Orig_Ent
: Entity_Id
;
109 -- The parameter Orig_Ent from the call to Check_Internal_Call
112 -- The current scope of the call. This is restored when we complete
113 -- the delayed call, so that we do this in the right scope.
115 From_Elab_Code
: Boolean;
116 -- Save indication of whether this call is from elaboration code
118 Outer_Scope
: Entity_Id
;
119 -- Save scope of outer level call
122 package Delay_Check
is new Table
.Table
(
123 Table_Component_Type
=> Delay_Element
,
124 Table_Index_Type
=> Int
,
125 Table_Low_Bound
=> 1,
126 Table_Initial
=> 1000,
127 Table_Increment
=> 100,
128 Table_Name
=> "Delay_Check");
131 -- Top level scope of current scope. Compute this only once at the outer
132 -- level, i.e. for a call to Check_Elab_Call from outside this unit.
134 Outer_Level_Sloc
: Source_Ptr
;
135 -- Save Sloc value for outer level call node for comparisons of source
136 -- locations. A body is too late if it appears after the *outer* level
137 -- call, not the particular call that is being analyzed.
139 From_Elab_Code
: Boolean;
140 -- This flag shows whether the outer level call currently being examined
141 -- is or is not in elaboration code. We are only interested in calls to
142 -- routines in other units if this flag is True.
144 In_Task_Activation
: Boolean := False;
145 -- This flag indicates whether we are performing elaboration checks on
146 -- task procedures, at the point of activation. If true, we do not trace
147 -- internal calls in these procedures, because all local bodies are known
150 Delaying_Elab_Checks
: Boolean := True;
151 -- This is set True till the compilation is complete, including the
152 -- insertion of all instance bodies. Then when Check_Elab_Calls is called,
153 -- the delay table is used to make the delayed calls and this flag is reset
154 -- to False, so that the calls are processed.
156 -----------------------
157 -- Local Subprograms --
158 -----------------------
160 -- Note: Outer_Scope in all following specs represents the scope of
161 -- interest of the outer level call. If it is set to Standard_Standard,
162 -- then it means the outer level call was at elaboration level, and that
163 -- thus all calls are of interest. If it was set to some other scope,
164 -- then the original call was an inner call, and we are not interested
165 -- in calls that go outside this scope.
167 procedure Activate_Elaborate_All_Desirable
(N
: Node_Id
; U
: Entity_Id
);
168 -- Analysis of construct N shows that we should set Elaborate_All_Desirable
169 -- for the WITH clause for unit U (which will always be present). A special
170 -- case is when N is a function or procedure instantiation, in which case
171 -- it is sufficient to set Elaborate_Desirable, since in this case there is
172 -- no possibility of transitive elaboration issues.
174 procedure Check_A_Call
177 Outer_Scope
: Entity_Id
;
178 Inter_Unit_Only
: Boolean;
179 Generate_Warnings
: Boolean := True;
180 In_Init_Proc
: Boolean := False);
181 -- This is the internal recursive routine that is called to check for
182 -- possible elaboration error. The argument N is a subprogram call or
183 -- generic instantiation, or 'Access attribute reference to be checked, and
184 -- E is the entity of the called subprogram, or instantiated generic unit,
185 -- or subprogram referenced by 'Access.
187 -- In SPARK mode, N can also be a variable reference, since in SPARK this
188 -- also triggers a requirement for Elaborate_All, and in this case E is the
189 -- entity being referenced.
191 -- Outer_Scope is the outer level scope for the original reference.
192 -- Inter_Unit_Only is set if the call is only to be checked in the
193 -- case where it is to another unit (and skipped if within a unit).
194 -- Generate_Warnings is set to False to suppress warning messages about
195 -- missing pragma Elaborate_All's. These messages are not wanted for
196 -- inner calls in the dynamic model. Note that an instance of the Access
197 -- attribute applied to a subprogram also generates a call to this
198 -- procedure (since the referenced subprogram may be called later
199 -- indirectly). Flag In_Init_Proc should be set whenever the current
200 -- context is a type init proc.
202 -- Note: this might better be called Check_A_Reference to recognize the
203 -- variable case for SPARK, but we prefer to retain the historical name
204 -- since in practice this is mostly about checking calls for the possible
205 -- occurrence of an access-before-elaboration exception.
207 procedure Check_Bad_Instantiation
(N
: Node_Id
);
208 -- N is a node for an instantiation (if called with any other node kind,
209 -- Check_Bad_Instantiation ignores the call). This subprogram checks for
210 -- the special case of a generic instantiation of a generic spec in the
211 -- same declarative part as the instantiation where a body is present and
212 -- has not yet been seen. This is an obvious error, but needs to be checked
213 -- specially at the time of the instantiation, since it is a case where we
214 -- cannot insert the body anywhere. If this case is detected, warnings are
215 -- generated, and a raise of Program_Error is inserted. In addition any
216 -- subprograms in the generic spec are stubbed, and the Bad_Instantiation
217 -- flag is set on the instantiation node. The caller in Sem_Ch12 uses this
218 -- flag as an indication that no attempt should be made to insert an
221 procedure Check_Internal_Call
224 Outer_Scope
: Entity_Id
;
225 Orig_Ent
: Entity_Id
);
226 -- N is a function call or procedure statement call node and E is the
227 -- entity of the called function, which is within the current compilation
228 -- unit (where subunits count as part of the parent). This call checks if
229 -- this call, or any call within any accessed body could cause an ABE, and
230 -- if so, outputs a warning. Orig_Ent differs from E only in the case of
231 -- renamings, and points to the original name of the entity. This is used
232 -- for error messages. Outer_Scope is the outer level scope for the
235 procedure Check_Internal_Call_Continue
238 Outer_Scope
: Entity_Id
;
239 Orig_Ent
: Entity_Id
);
240 -- The processing for Check_Internal_Call is divided up into two phases,
241 -- and this represents the second phase. The second phase is delayed if
242 -- Delaying_Elab_Calls is set to True. In this delayed case, the first
243 -- phase makes an entry in the Delay_Check table, which is processed when
244 -- Check_Elab_Calls is called. N, E and Orig_Ent are as for the call to
245 -- Check_Internal_Call. Outer_Scope is the outer level scope for the
248 function Has_Generic_Body
(N
: Node_Id
) return Boolean;
249 -- N is a generic package instantiation node, and this routine determines
250 -- if this package spec does in fact have a generic body. If so, then
251 -- True is returned, otherwise False. Note that this is not at all the
252 -- same as checking if the unit requires a body, since it deals with
253 -- the case of optional bodies accurately (i.e. if a body is optional,
254 -- then it looks to see if a body is actually present). Note: this
255 -- function can only do a fully correct job if in generating code mode
256 -- where all bodies have to be present. If we are operating in semantics
257 -- check only mode, then in some cases of optional bodies, a result of
258 -- False may incorrectly be given. In practice this simply means that
259 -- some cases of warnings for incorrect order of elaboration will only
260 -- be given when generating code, which is not a big problem (and is
261 -- inevitable, given the optional body semantics of Ada).
263 procedure Insert_Elab_Check
(N
: Node_Id
; C
: Node_Id
:= Empty
);
264 -- Given code for an elaboration check (or unconditional raise if the check
265 -- is not needed), inserts the code in the appropriate place. N is the call
266 -- or instantiation node for which the check code is required. C is the
267 -- test whose failure triggers the raise.
269 function Is_Call_Of_Generic_Formal
(N
: Node_Id
) return Boolean;
270 -- Returns True if node N is a call to a generic formal subprogram
272 function Is_Finalization_Procedure
(Id
: Entity_Id
) return Boolean;
273 -- Determine whether entity Id denotes a [Deep_]Finalize procedure
275 procedure Output_Calls
277 Check_Elab_Flag
: Boolean);
278 -- Outputs chain of calls stored in the Elab_Call table. The caller has
279 -- already generated the main warning message, so the warnings generated
280 -- are all continuation messages. The argument is the call node at which
281 -- the messages are to be placed. When Check_Elab_Flag is set, calls are
282 -- enumerated only when flag Elab_Warning is set for the dynamic case or
283 -- when flag Elab_Info_Messages is set for the static case.
285 function Same_Elaboration_Scope
(Scop1
, Scop2
: Entity_Id
) return Boolean;
286 -- Given two scopes, determine whether they are the same scope from an
287 -- elaboration point of view, i.e. packages and blocks are ignored.
289 procedure Set_C_Scope
;
290 -- On entry C_Scope is set to some scope. On return, C_Scope is reset
291 -- to be the enclosing compilation unit of this scope.
293 function Get_Referenced_Ent
(N
: Node_Id
) return Entity_Id
;
294 -- N is either a function or procedure call or an access attribute that
295 -- references a subprogram. This call retrieves the relevant entity. If
296 -- this is a call to a protected subprogram, the entity is a selected
297 -- component. The callable entity may be absent, in which case Empty is
298 -- returned. This happens with non-analyzed calls in nested generics.
300 -- If SPARK_Mode is On, then N can also be a reference to an E_Variable
301 -- entity, in which case, the value returned is simply this entity.
303 procedure Set_Elaboration_Constraint
307 -- The current unit U may depend semantically on some unit P which is not
308 -- in the current context. If there is an elaboration call that reaches P,
309 -- we need to indicate that P requires an Elaborate_All, but this is not
310 -- effective in U's ali file, if there is no with_clause for P. In this
311 -- case we add the Elaborate_All on the unit Q that directly or indirectly
312 -- makes P available. This can happen in two cases:
314 -- a) Q declares a subtype of a type declared in P, and the call is an
315 -- initialization call for an object of that subtype.
317 -- b) Q declares an object of some tagged type whose root type is
318 -- declared in P, and the initialization call uses object notation on
319 -- that object to reach a primitive operation or a classwide operation
322 -- If P appears in the context of U, the current processing is correct.
323 -- Otherwise we must identify these two cases to retrieve Q and place the
324 -- Elaborate_All_Desirable on it.
326 function Spec_Entity
(E
: Entity_Id
) return Entity_Id
;
327 -- Given a compilation unit entity, if it is a spec entity, it is returned
328 -- unchanged. If it is a body entity, then the spec for the corresponding
331 procedure Supply_Bodies
(N
: Node_Id
);
332 -- Given a node, N, that is either a subprogram declaration or a package
333 -- declaration, this procedure supplies dummy bodies for the subprogram
334 -- or for all subprograms in the package. If the given node is not one of
335 -- these two possibilities, then Supply_Bodies does nothing. The dummy body
336 -- contains a single Raise statement.
338 procedure Supply_Bodies
(L
: List_Id
);
339 -- Calls Supply_Bodies for all elements of the given list L
341 function Within
(E1
, E2
: Entity_Id
) return Boolean;
342 -- Given two scopes E1 and E2, returns True if E1 is equal to E2, or is one
343 -- of its contained scopes, False otherwise.
345 function Within_Elaborate_All
346 (Unit
: Unit_Number_Type
;
347 E
: Entity_Id
) return Boolean;
348 -- Return True if we are within the scope of an Elaborate_All for E, or if
349 -- we are within the scope of an Elaborate_All for some other unit U, and U
350 -- with's E. This prevents spurious warnings when the called entity is
351 -- renamed within U, or in case of generic instances.
353 --------------------------------------
354 -- Activate_Elaborate_All_Desirable --
355 --------------------------------------
357 procedure Activate_Elaborate_All_Desirable
(N
: Node_Id
; U
: Entity_Id
) is
358 UN
: constant Unit_Number_Type
:= Get_Code_Unit
(N
);
359 CU
: constant Node_Id
:= Cunit
(UN
);
360 UE
: constant Entity_Id
:= Cunit_Entity
(UN
);
361 Unm
: constant Unit_Name_Type
:= Unit_Name
(UN
);
362 CI
: constant List_Id
:= Context_Items
(CU
);
366 procedure Add_To_Context_And_Mark
(Itm
: Node_Id
);
367 -- This procedure is called when the elaborate indication must be
368 -- applied to a unit not in the context of the referencing unit. The
369 -- unit gets added to the context as an implicit with.
371 function In_Withs_Of
(UEs
: Entity_Id
) return Boolean;
372 -- UEs is the spec entity of a unit. If the unit to be marked is
373 -- in the context item list of this unit spec, then the call returns
374 -- True and Itm is left set to point to the relevant N_With_Clause node.
376 procedure Set_Elab_Flag
(Itm
: Node_Id
);
377 -- Sets Elaborate_[All_]Desirable as appropriate on Itm
379 -----------------------------
380 -- Add_To_Context_And_Mark --
381 -----------------------------
383 procedure Add_To_Context_And_Mark
(Itm
: Node_Id
) is
384 CW
: constant Node_Id
:=
385 Make_With_Clause
(Sloc
(Itm
),
389 Set_Library_Unit
(CW
, Library_Unit
(Itm
));
390 Set_Implicit_With
(CW
, True);
392 -- Set elaborate all desirable on copy and then append the copy to
393 -- the list of body with's and we are done.
397 end Add_To_Context_And_Mark
;
403 function In_Withs_Of
(UEs
: Entity_Id
) return Boolean is
404 UNs
: constant Unit_Number_Type
:= Get_Source_Unit
(UEs
);
405 CUs
: constant Node_Id
:= Cunit
(UNs
);
406 CIs
: constant List_Id
:= Context_Items
(CUs
);
410 while Present
(Itm
) loop
411 if Nkind
(Itm
) = N_With_Clause
then
413 Cunit_Entity
(Get_Cunit_Unit_Number
(Library_Unit
(Itm
)));
430 procedure Set_Elab_Flag
(Itm
: Node_Id
) is
432 if Nkind
(N
) in N_Subprogram_Instantiation
then
433 Set_Elaborate_Desirable
(Itm
);
435 Set_Elaborate_All_Desirable
(Itm
);
439 -- Start of processing for Activate_Elaborate_All_Desirable
442 -- Do not set binder indication if expansion is disabled, as when
443 -- compiling a generic unit.
445 if not Expander_Active
then
450 while Present
(Itm
) loop
451 if Nkind
(Itm
) = N_With_Clause
then
452 Ent
:= Cunit_Entity
(Get_Cunit_Unit_Number
(Library_Unit
(Itm
)));
454 -- If we find it, then mark elaborate all desirable and return
465 -- If we fall through then the with clause is not present in the
466 -- current unit. One legitimate possibility is that the with clause
467 -- is present in the spec when we are a body.
469 if Is_Body_Name
(Unm
)
470 and then In_Withs_Of
(Spec_Entity
(UE
))
472 Add_To_Context_And_Mark
(Itm
);
476 -- Similarly, we may be in the spec or body of a child unit, where
477 -- the unit in question is with'ed by some ancestor of the child unit.
479 if Is_Child_Name
(Unm
) then
487 exit when Pkg
= Standard_Standard
;
489 if In_Withs_Of
(Pkg
) then
490 Add_To_Context_And_Mark
(Itm
);
497 -- Here if we do not find with clause on spec or body. We just ignore
498 -- this case, it means that the elaboration involves some other unit
499 -- than the unit being compiled, and will be caught elsewhere.
502 end Activate_Elaborate_All_Desirable
;
508 procedure Check_A_Call
511 Outer_Scope
: Entity_Id
;
512 Inter_Unit_Only
: Boolean;
513 Generate_Warnings
: Boolean := True;
514 In_Init_Proc
: Boolean := False)
516 Access_Case
: constant Boolean := Nkind
(N
) = N_Attribute_Reference
;
517 -- Indicates if we have Access attribute case
519 Variable_Case
: constant Boolean :=
520 Nkind
(N
) in N_Has_Entity
521 and then Present
(Entity
(N
))
522 and then Ekind
(Entity
(N
)) = E_Variable
;
523 -- Indicates if we have variable reference case
525 procedure Elab_Warning
528 Ent
: Node_Or_Entity_Id
);
529 -- Generate a call to Error_Msg_NE with parameters Msg_D or Msg_S (for
530 -- dynamic or static elaboration model), N and Ent. Msg_D is a real
531 -- warning (output if Msg_D is non-null and Elab_Warnings is set),
532 -- Msg_S is an info message (output if Elab_Info_Messages is set.
538 procedure Elab_Warning
541 Ent
: Node_Or_Entity_Id
)
544 -- Dynamic elaboration checks, real warning
546 if Dynamic_Elaboration_Checks
then
547 if not Access_Case
then
548 if Msg_D
/= "" and then Elab_Warnings
then
549 Error_Msg_NE
(Msg_D
, N
, Ent
);
553 -- Static elaboration checks, info message
556 if Elab_Info_Messages
then
557 Error_Msg_NE
(Msg_S
, N
, Ent
);
564 Loc
: constant Source_Ptr
:= Sloc
(N
);
569 -- Top level scope of entity for called subprogram. This value includes
570 -- following renamings and derivations, so this scope can be in a
571 -- non-visible unit. This is the scope that is to be investigated to
572 -- see whether an elaboration check is required.
575 -- Top level scope of directly called entity for subprogram. This
576 -- differs from E_Scope in the case where renamings or derivations
577 -- are involved, since it does not follow these links. W_Scope is
578 -- generally in a visible unit, and it is this scope that may require
579 -- an Elaborate_All. However, there are some cases (initialization
580 -- calls and calls involving object notation) where W_Scope might not
581 -- be in the context of the current unit, and there is an intermediate
582 -- package that is, in which case the Elaborate_All has to be placed
583 -- on this intermediate package. These special cases are handled in
584 -- Set_Elaboration_Constraint.
586 Body_Acts_As_Spec
: Boolean;
587 -- Set to true if call is to body acting as spec (no separate spec)
589 Inst_Case
: constant Boolean := Nkind
(N
) in N_Generic_Instantiation
;
590 -- Indicates if we have instantiation case
592 Caller_Unit_Internal
: Boolean;
593 Callee_Unit_Internal
: Boolean;
595 Inst_Caller
: Source_Ptr
;
596 Inst_Callee
: Source_Ptr
;
598 Unit_Caller
: Unit_Number_Type
;
599 Unit_Callee
: Unit_Number_Type
;
601 Cunit_SC
: Boolean := False;
602 -- Set to suppress dynamic elaboration checks where one of the
603 -- enclosing scopes has Elaboration_Checks_Suppressed set, or else
604 -- if a pragma Elaborate[_All] applies to that scope, in which case
605 -- warnings on the scope are also suppressed. For the internal case,
606 -- we ignore this flag.
608 -- Start of processing for Check_A_Call
611 -- If the call is known to be within a local Suppress Elaboration
612 -- pragma, nothing to check. This can happen in task bodies. But
613 -- we ignore this for a call to a generic formal.
615 if Nkind
(N
) in N_Subprogram_Call
616 and then No_Elaboration_Check
(N
)
617 and then not Is_Call_Of_Generic_Formal
(N
)
622 -- If this is a rewrite of a Valid_Scalars attribute, then nothing to
623 -- check, we don't mind in this case if the call occurs before the body
624 -- since this is all generated code.
626 if Nkind
(Original_Node
(N
)) = N_Attribute_Reference
627 and then Attribute_Name
(Original_Node
(N
)) = Name_Valid_Scalars
632 -- Proceed with check
636 -- For a variable reference, just set Body_Acts_As_Spec to False
638 if Variable_Case
then
639 Body_Acts_As_Spec
:= False;
641 -- Additional checks for all other cases
644 -- Go to parent for derived subprogram, or to original subprogram in
645 -- the case of a renaming (Alias covers both these cases).
648 if (Suppress_Elaboration_Warnings
(Ent
)
649 or else Elaboration_Checks_Suppressed
(Ent
))
650 and then (Inst_Case
or else No
(Alias
(Ent
)))
655 -- Nothing to do for imported entities
657 if Is_Imported
(Ent
) then
661 exit when Inst_Case
or else No
(Alias
(Ent
));
665 Decl
:= Unit_Declaration_Node
(Ent
);
667 if Nkind
(Decl
) = N_Subprogram_Body
then
668 Body_Acts_As_Spec
:= True;
670 elsif Nkind_In
(Decl
, N_Subprogram_Declaration
,
671 N_Subprogram_Body_Stub
)
674 Body_Acts_As_Spec
:= False;
676 -- If we have none of an instantiation, subprogram body or subprogram
677 -- declaration, or in the SPARK case, a variable reference, then
678 -- it is not a case that we want to check. (One case is a call to a
679 -- generic formal subprogram, where we do not want the check in the
689 if Elaboration_Checks_Suppressed
(E_Scope
)
690 or else Suppress_Elaboration_Warnings
(E_Scope
)
695 -- Exit when we get to compilation unit, not counting subunits
697 exit when Is_Compilation_Unit
(E_Scope
)
698 and then (Is_Child_Unit
(E_Scope
)
699 or else Scope
(E_Scope
) = Standard_Standard
);
701 -- If we did not find a compilation unit, other than standard,
702 -- then nothing to check (happens in some instantiation cases)
704 if E_Scope
= Standard_Standard
then
707 -- Otherwise move up a scope looking for compilation unit
710 E_Scope
:= Scope
(E_Scope
);
714 -- No checks needed for pure or preelaborated compilation units
716 if Is_Pure
(E_Scope
) or else Is_Preelaborated
(E_Scope
) then
720 -- If the generic entity is within a deeper instance than we are, then
721 -- either the instantiation to which we refer itself caused an ABE, in
722 -- which case that will be handled separately, or else we know that the
723 -- body we need appears as needed at the point of the instantiation.
724 -- However, this assumption is only valid if we are in static mode.
726 if not Dynamic_Elaboration_Checks
728 Instantiation_Depth
(Sloc
(Ent
)) > Instantiation_Depth
(Sloc
(N
))
733 -- Do not give a warning for a package with no body
735 if Ekind
(Ent
) = E_Generic_Package
and then not Has_Generic_Body
(N
) then
739 -- Find top level scope for called entity (not following renamings
740 -- or derivations). This is where the Elaborate_All will go if it is
741 -- needed. We start with the called entity, except in the case of an
742 -- initialization procedure outside the current package, where the init
743 -- proc is in the root package, and we start from the entity of the name
747 Ent
: constant Entity_Id
:= Get_Referenced_Ent
(N
);
749 if Is_Init_Proc
(Ent
)
750 and then not In_Same_Extended_Unit
(N
, Ent
)
752 W_Scope
:= Scope
(Ent
);
758 -- Now loop through scopes to get to the enclosing compilation unit
760 while not Is_Compilation_Unit
(W_Scope
) loop
761 W_Scope
:= Scope
(W_Scope
);
764 -- Case of entity is in same unit as call or instantiation. In the
765 -- instantiation case, W_Scope may be different from E_Scope; we want
766 -- the unit in which the instantiation occurs, since we're analyzing
767 -- based on the expansion.
769 if W_Scope
= C_Scope
then
770 if not Inter_Unit_Only
then
771 Check_Internal_Call
(N
, Ent
, Outer_Scope
, E
);
777 -- Case of entity is not in current unit (i.e. with'ed unit case)
779 -- We are only interested in such calls if the outer call was from
780 -- elaboration code, or if we are in Dynamic_Elaboration_Checks mode.
782 if not From_Elab_Code
and then not Dynamic_Elaboration_Checks
then
786 -- Nothing to do if some scope said that no checks were required
792 -- Nothing to do for a generic instance, because in this case the
793 -- checking was at the point of instantiation of the generic However,
794 -- this shortcut is only applicable in static mode.
796 if Is_Generic_Instance
(Ent
) and not Dynamic_Elaboration_Checks
then
800 -- Nothing to do if subprogram with no separate spec. However, a call
801 -- to Deep_Initialize may result in a call to a user-defined Initialize
802 -- procedure, which imposes a body dependency. This happens only if the
803 -- type is controlled and the Initialize procedure is not inherited.
805 if Body_Acts_As_Spec
then
806 if Is_TSS
(Ent
, TSS_Deep_Initialize
) then
808 Typ
: constant Entity_Id
:= Etype
(First_Formal
(Ent
));
812 if not Is_Controlled
(Typ
) then
815 Init
:= Find_Prim_Op
(Typ
, Name_Initialize
);
817 if Comes_From_Source
(Init
) then
830 -- Check cases of internal units
832 Callee_Unit_Internal
:=
833 Is_Internal_File_Name
(Unit_File_Name
(Get_Source_Unit
(E_Scope
)));
835 -- Do not give a warning if the with'ed unit is internal and this is
836 -- the generic instantiation case (this saves a lot of hassle dealing
837 -- with the Text_IO special child units)
839 if Callee_Unit_Internal
and Inst_Case
then
843 if C_Scope
= Standard_Standard
then
844 Caller_Unit_Internal
:= False;
846 Caller_Unit_Internal
:=
847 Is_Internal_File_Name
(Unit_File_Name
(Get_Source_Unit
(C_Scope
)));
850 -- Do not give a warning if the with'ed unit is internal and the
851 -- caller is not internal (since the binder always elaborates
852 -- internal units first).
854 if Callee_Unit_Internal
and (not Caller_Unit_Internal
) then
858 -- For now, if debug flag -gnatdE is not set, do no checking for
859 -- one internal unit withing another. This fixes the problem with
860 -- the sgi build and storage errors. To be resolved later ???
862 if (Callee_Unit_Internal
and Caller_Unit_Internal
)
863 and not Debug_Flag_EE
868 if Is_TSS
(E
, TSS_Deep_Initialize
) then
872 -- If the call is in an instance, and the called entity is not
873 -- defined in the same instance, then the elaboration issue focuses
874 -- around the unit containing the template, it is this unit which
875 -- requires an Elaborate_All.
877 -- However, if we are doing dynamic elaboration, we need to chase the
878 -- call in the usual manner.
880 -- We also need to chase the call in the usual manner if it is a call
881 -- to a generic formal parameter, since that case was not handled as
882 -- part of the processing of the template.
884 Inst_Caller
:= Instantiation
(Get_Source_File_Index
(Sloc
(N
)));
885 Inst_Callee
:= Instantiation
(Get_Source_File_Index
(Sloc
(Ent
)));
887 if Inst_Caller
= No_Location
then
888 Unit_Caller
:= No_Unit
;
890 Unit_Caller
:= Get_Source_Unit
(N
);
893 if Inst_Callee
= No_Location
then
894 Unit_Callee
:= No_Unit
;
896 Unit_Callee
:= Get_Source_Unit
(Ent
);
899 if Unit_Caller
/= No_Unit
900 and then Unit_Callee
/= Unit_Caller
901 and then not Dynamic_Elaboration_Checks
902 and then not Is_Call_Of_Generic_Formal
(N
)
904 E_Scope
:= Spec_Entity
(Cunit_Entity
(Unit_Caller
));
906 -- If we don't get a spec entity, just ignore call. Not quite
907 -- clear why this check is necessary. ???
913 -- Otherwise step to enclosing compilation unit
915 while not Is_Compilation_Unit
(E_Scope
) loop
916 E_Scope
:= Scope
(E_Scope
);
919 -- For the case where N is not an instance, and is not a call within
920 -- instance to other than a generic formal, we recompute E_Scope
921 -- for the error message, since we do NOT want to go to the unit
922 -- which has the ultimate declaration in the case of renaming and
923 -- derivation and we also want to go to the generic unit in the
924 -- case of an instance, and no further.
927 -- Loop to carefully follow renamings and derivations one step
928 -- outside the current unit, but not further.
930 if not (Inst_Case
or Variable_Case
)
931 and then Present
(Alias
(Ent
))
933 E_Scope
:= Alias
(Ent
);
939 while not Is_Compilation_Unit
(E_Scope
) loop
940 E_Scope
:= Scope
(E_Scope
);
943 -- If E_Scope is the same as C_Scope, it means that there
944 -- definitely was a local renaming or derivation, and we
945 -- are not yet out of the current unit.
947 exit when E_Scope
/= C_Scope
;
951 -- If no alias, there is a previous error
954 Check_Error_Detected
;
960 if Within_Elaborate_All
(Current_Sem_Unit
, E_Scope
) then
964 -- Now check if an Elaborate_All (or dynamic check) is needed
966 if not Suppress_Elaboration_Warnings
(Ent
)
967 and then not Elaboration_Checks_Suppressed
(Ent
)
968 and then not Suppress_Elaboration_Warnings
(E_Scope
)
969 and then not Elaboration_Checks_Suppressed
(E_Scope
)
970 and then ((Elab_Warnings
or Elab_Info_Messages
)
971 or else SPARK_Mode
= On
)
972 and then Generate_Warnings
974 -- Instantiation case
977 if SPARK_Mode
= On
then
979 ("instantiation of & during elaboration in SPARK", N
, Ent
);
983 ("instantiation of & may raise Program_Error?l?",
984 "info: instantiation of & during elaboration?$?", Ent
);
987 -- Indirect call case, info message only in static elaboration
988 -- case, because the attribute reference itself cannot raise an
989 -- exception. Note that SPARK does not permit indirect calls.
991 elsif Access_Case
then
992 Elab_Warning
("", "info: access to & during elaboration?$?", Ent
);
994 -- Variable reference in SPARK mode
996 elsif Variable_Case
then
998 ("reference to & during elaboration in SPARK", N
, Ent
);
1000 -- Subprogram call case
1003 if Nkind
(Name
(N
)) in N_Has_Entity
1004 and then Is_Init_Proc
(Entity
(Name
(N
)))
1005 and then Comes_From_Source
(Ent
)
1008 ("implicit call to & may raise Program_Error?l?",
1009 "info: implicit call to & during elaboration?$?",
1012 elsif SPARK_Mode
= On
then
1013 Error_Msg_NE
("call to & during elaboration in SPARK", N
, Ent
);
1017 ("call to & may raise Program_Error?l?",
1018 "info: call to & during elaboration?$?",
1023 Error_Msg_Qual_Level
:= Nat
'Last;
1025 -- Case of Elaborate_All not present and required, for SPARK this
1026 -- is an error, so give an error message.
1028 if SPARK_Mode
= On
then
1029 Error_Msg_NE
("\Elaborate_All pragma required for&", N
, W_Scope
);
1031 -- Otherwise we generate an implicit pragma. For a subprogram
1032 -- instantiation, Elaborate is good enough, since no transitive
1033 -- call is possible at elaboration time in this case.
1035 elsif Nkind
(N
) in N_Subprogram_Instantiation
then
1037 ("\missing pragma Elaborate for&?l?",
1038 "\implicit pragma Elaborate for& generated?$?",
1041 -- For all other cases, we need an implicit Elaborate_All
1045 ("\missing pragma Elaborate_All for&?l?",
1046 "\implicit pragma Elaborate_All for & generated?$?",
1050 Error_Msg_Qual_Level
:= 0;
1052 -- Take into account the flags related to elaboration warning
1053 -- messages when enumerating the various calls involved. This
1054 -- ensures the proper pairing of the main warning and the
1055 -- clarification messages generated by Output_Calls.
1057 Output_Calls
(N
, Check_Elab_Flag
=> True);
1059 -- Set flag to prevent further warnings for same unit unless in
1062 if not All_Errors_Mode
and not Dynamic_Elaboration_Checks
then
1063 Set_Suppress_Elaboration_Warnings
(W_Scope
, True);
1067 -- Check for runtime elaboration check required
1069 if Dynamic_Elaboration_Checks
then
1070 if not Elaboration_Checks_Suppressed
(Ent
)
1071 and then not Elaboration_Checks_Suppressed
(W_Scope
)
1072 and then not Elaboration_Checks_Suppressed
(E_Scope
)
1073 and then not Cunit_SC
1075 -- Runtime elaboration check required. Generate check of the
1076 -- elaboration Boolean for the unit containing the entity.
1078 -- Note that for this case, we do check the real unit (the one
1079 -- from following renamings, since that is the issue).
1081 -- Could this possibly miss a useless but required PE???
1083 Insert_Elab_Check
(N
,
1084 Make_Attribute_Reference
(Loc
,
1085 Attribute_Name
=> Name_Elaborated
,
1087 New_Occurrence_Of
(Spec_Entity
(E_Scope
), Loc
)));
1089 -- Prevent duplicate elaboration checks on the same call,
1090 -- which can happen if the body enclosing the call appears
1091 -- itself in a call whose elaboration check is delayed.
1093 if Nkind
(N
) in N_Subprogram_Call
then
1094 Set_No_Elaboration_Check
(N
);
1098 -- Case of static elaboration model
1101 -- Do not do anything if elaboration checks suppressed. Note that
1102 -- we check Ent here, not E, since we want the real entity for the
1103 -- body to see if checks are suppressed for it, not the dummy
1104 -- entry for renamings or derivations.
1106 if Elaboration_Checks_Suppressed
(Ent
)
1107 or else Elaboration_Checks_Suppressed
(E_Scope
)
1108 or else Elaboration_Checks_Suppressed
(W_Scope
)
1112 -- Do not generate an Elaborate_All for finalization routines
1113 -- which perform partial clean up as part of initialization.
1115 elsif In_Init_Proc
and then Is_Finalization_Procedure
(Ent
) then
1118 -- Here we need to generate an implicit elaborate all
1121 -- Generate Elaborate_All warning unless suppressed
1123 if (Elab_Info_Messages
and Generate_Warnings
and not Inst_Case
)
1124 and then not Suppress_Elaboration_Warnings
(Ent
)
1125 and then not Suppress_Elaboration_Warnings
(E_Scope
)
1126 and then not Suppress_Elaboration_Warnings
(W_Scope
)
1128 Error_Msg_Node_2
:= W_Scope
;
1130 ("info: call to& in elaboration code " &
1131 "requires pragma Elaborate_All on&?$?", N
, E
);
1134 -- Set indication for binder to generate Elaborate_All
1136 Set_Elaboration_Constraint
(N
, E
, W_Scope
);
1141 -----------------------------
1142 -- Check_Bad_Instantiation --
1143 -----------------------------
1145 procedure Check_Bad_Instantiation
(N
: Node_Id
) is
1149 -- Nothing to do if we do not have an instantiation (happens in some
1150 -- error cases, and also in the formal package declaration case)
1152 if Nkind
(N
) not in N_Generic_Instantiation
then
1155 -- Nothing to do if serious errors detected (avoid cascaded errors)
1157 elsif Serious_Errors_Detected
/= 0 then
1160 -- Nothing to do if not in full analysis mode
1162 elsif not Full_Analysis
then
1165 -- Nothing to do if inside a generic template
1167 elsif Inside_A_Generic
then
1170 -- Nothing to do if a library level instantiation
1172 elsif Nkind
(Parent
(N
)) = N_Compilation_Unit
then
1175 -- Nothing to do if we are compiling a proper body for semantic
1176 -- purposes only. The generic body may be in another proper body.
1179 Nkind
(Parent
(Unit_Declaration_Node
(Main_Unit_Entity
))) = N_Subunit
1184 Ent
:= Get_Generic_Entity
(N
);
1186 -- The case we are interested in is when the generic spec is in the
1187 -- current declarative part
1189 if not Same_Elaboration_Scope
(Current_Scope
, Scope
(Ent
))
1190 or else not In_Same_Extended_Unit
(N
, Ent
)
1195 -- If the generic entity is within a deeper instance than we are, then
1196 -- either the instantiation to which we refer itself caused an ABE, in
1197 -- which case that will be handled separately. Otherwise, we know that
1198 -- the body we need appears as needed at the point of the instantiation.
1199 -- If they are both at the same level but not within the same instance
1200 -- then the body of the generic will be in the earlier instance.
1203 D1
: constant Int
:= Instantiation_Depth
(Sloc
(Ent
));
1204 D2
: constant Int
:= Instantiation_Depth
(Sloc
(N
));
1211 and then Is_Generic_Instance
(Scope
(Ent
))
1212 and then not In_Open_Scopes
(Scope
(Ent
))
1218 -- Now we can proceed, if the entity being called has a completion,
1219 -- then we are definitely OK, since we have already seen the body.
1221 if Has_Completion
(Ent
) then
1225 -- If there is no body, then nothing to do
1227 if not Has_Generic_Body
(N
) then
1231 -- Here we definitely have a bad instantiation
1233 Error_Msg_Warn
:= SPARK_Mode
/= On
;
1234 Error_Msg_NE
("cannot instantiate& before body seen<<", N
, Ent
);
1236 if Present
(Instance_Spec
(N
)) then
1237 Supply_Bodies
(Instance_Spec
(N
));
1240 Error_Msg_N
("\Program_Error [<<", N
);
1241 Insert_Elab_Check
(N
);
1242 Set_ABE_Is_Certain
(N
);
1243 end Check_Bad_Instantiation
;
1245 ---------------------
1246 -- Check_Elab_Call --
1247 ---------------------
1249 procedure Check_Elab_Call
1251 Outer_Scope
: Entity_Id
:= Empty
;
1252 In_Init_Proc
: Boolean := False)
1258 -- If the reference is not in the main unit, there is nothing to check.
1259 -- Elaboration call from units in the context of the main unit will lead
1260 -- to semantic dependencies when those units are compiled.
1262 if not In_Extended_Main_Code_Unit
(N
) then
1266 -- For an entry call, check relevant restriction
1268 if Nkind
(N
) = N_Entry_Call_Statement
1269 and then not In_Subprogram_Or_Concurrent_Unit
1271 Check_Restriction
(No_Entry_Calls_In_Elaboration_Code
, N
);
1273 -- Nothing to do if this is not an expected type of reference (happens
1274 -- in some error conditions, and in some cases where rewriting occurs).
1276 elsif Nkind
(N
) not in N_Subprogram_Call
1277 and then Nkind
(N
) /= N_Attribute_Reference
1278 and then (SPARK_Mode
/= On
1279 or else Nkind
(N
) not in N_Has_Entity
1280 or else No
(Entity
(N
))
1281 or else Ekind
(Entity
(N
)) /= E_Variable
)
1285 -- Nothing to do if this is a call already rewritten for elab checking.
1286 -- Such calls appear as the targets of If_Expressions.
1288 -- This check MUST be wrong, it catches far too much
1290 elsif Nkind
(Parent
(N
)) = N_If_Expression
then
1293 -- Nothing to do if inside a generic template
1295 elsif Inside_A_Generic
1296 and then No
(Enclosing_Generic_Body
(N
))
1300 -- Nothing to do if call is being pre-analyzed, as when within a
1301 -- pre/postcondition, a predicate, or an invariant.
1303 elsif In_Spec_Expression
then
1307 -- Nothing to do if this is a call to a postcondition, which is always
1308 -- within a subprogram body, even though the current scope may be the
1309 -- enclosing scope of the subprogram.
1311 if Nkind
(N
) = N_Procedure_Call_Statement
1312 and then Is_Entity_Name
(Name
(N
))
1313 and then Chars
(Entity
(Name
(N
))) = Name_uPostconditions
1318 -- Here we have a reference at elaboration time which must be checked
1320 if Debug_Flag_LL
then
1321 Write_Str
(" Check_Elab_Ref: ");
1323 if Nkind
(N
) = N_Attribute_Reference
then
1324 if not Is_Entity_Name
(Prefix
(N
)) then
1325 Write_Str
("<<not entity name>>");
1327 Write_Name
(Chars
(Entity
(Prefix
(N
))));
1330 Write_Str
("'Access");
1332 elsif No
(Name
(N
)) or else not Is_Entity_Name
(Name
(N
)) then
1333 Write_Str
("<<not entity name>> ");
1336 Write_Name
(Chars
(Entity
(Name
(N
))));
1339 Write_Str
(" reference at ");
1340 Write_Location
(Sloc
(N
));
1344 -- Climb up the tree to make sure we are not inside default expression
1345 -- of a parameter specification or a record component, since in both
1346 -- these cases, we will be doing the actual reference later, not now,
1347 -- and it is at the time of the actual reference (statically speaking)
1348 -- that we must do our static check, not at the time of its initial
1351 -- However, we have to check references within component definitions
1352 -- (e.g. a function call that determines an array component bound),
1353 -- so we terminate the loop in that case.
1356 while Present
(P
) loop
1357 if Nkind_In
(P
, N_Parameter_Specification
,
1358 N_Component_Declaration
)
1362 -- The reference occurs within the constraint of a component,
1363 -- so it must be checked.
1365 elsif Nkind
(P
) = N_Component_Definition
then
1373 -- Stuff that happens only at the outer level
1375 if No
(Outer_Scope
) then
1376 Elab_Visited
.Set_Last
(0);
1378 -- Nothing to do if current scope is Standard (this is a bit odd, but
1379 -- it happens in the case of generic instantiations).
1381 C_Scope
:= Current_Scope
;
1383 if C_Scope
= Standard_Standard
then
1387 -- First case, we are in elaboration code
1389 From_Elab_Code
:= not In_Subprogram_Or_Concurrent_Unit
;
1391 if From_Elab_Code
then
1393 -- Complain if ref that comes from source in preelaborated unit
1394 -- and we are not inside a subprogram (i.e. we are in elab code).
1396 if Comes_From_Source
(N
)
1397 and then In_Preelaborated_Unit
1398 and then not In_Inlined_Body
1399 and then Nkind
(N
) /= N_Attribute_Reference
1401 -- This is a warning in GNAT mode allowing such calls to be
1402 -- used in the predefined library with appropriate care.
1404 Error_Msg_Warn
:= GNAT_Mode
;
1406 ("<<non-static call not allowed in preelaborated unit", N
);
1410 -- Second case, we are inside a subprogram or concurrent unit, which
1411 -- means we are not in elaboration code.
1414 -- In this case, the issue is whether we are inside the
1415 -- declarative part of the unit in which we live, or inside its
1416 -- statements. In the latter case, there is no issue of ABE calls
1417 -- at this level (a call from outside to the unit in which we live
1418 -- might cause an ABE, but that will be detected when we analyze
1419 -- that outer level call, as it recurses into the called unit).
1421 -- Climb up the tree, doing this test, and also testing for being
1422 -- inside a default expression, which, as discussed above, is not
1423 -- checked at this stage.
1432 -- If we find a parentless subtree, it seems safe to assume
1433 -- that we are not in a declarative part and that no
1434 -- checking is required.
1440 if Is_List_Member
(P
) then
1441 L
:= List_Containing
(P
);
1448 exit when Nkind
(P
) = N_Subunit
;
1450 -- Filter out case of default expressions, where we do not
1451 -- do the check at this stage.
1453 if Nkind_In
(P
, N_Parameter_Specification
,
1454 N_Component_Declaration
)
1459 -- A protected body has no elaboration code and contains
1460 -- only other bodies.
1462 if Nkind
(P
) = N_Protected_Body
then
1465 elsif Nkind_In
(P
, N_Subprogram_Body
,
1470 if L
= Declarations
(P
) then
1473 -- We are not in elaboration code, but we are doing
1474 -- dynamic elaboration checks, in this case, we still
1475 -- need to do the reference, since the subprogram we are
1476 -- in could be called from another unit, also in dynamic
1477 -- elaboration check mode, at elaboration time.
1479 elsif Dynamic_Elaboration_Checks
then
1481 -- We provide a debug flag to disable this check. That
1482 -- way we have an easy work around for regressions
1483 -- that are caused by this new check. This debug flag
1484 -- can be removed later.
1486 if Debug_Flag_DD
then
1490 -- Do the check in this case
1494 elsif Nkind
(P
) = N_Task_Body
then
1496 -- The check is deferred until Check_Task_Activation
1497 -- but we need to capture local suppress pragmas
1498 -- that may inhibit checks on this call.
1500 Ent
:= Get_Referenced_Ent
(N
);
1505 elsif Elaboration_Checks_Suppressed
(Current_Scope
)
1506 or else Elaboration_Checks_Suppressed
(Ent
)
1507 or else Elaboration_Checks_Suppressed
(Scope
(Ent
))
1509 Set_No_Elaboration_Check
(N
);
1514 -- Static model, call is not in elaboration code, we
1515 -- never need to worry, because in the static model the
1516 -- top level caller always takes care of things.
1527 Ent
:= Get_Referenced_Ent
(N
);
1533 -- Nothing to do if this is a recursive call (i.e. a call to
1534 -- an entity that is already in the Elab_Call stack)
1536 for J
in 1 .. Elab_Visited
.Last
loop
1537 if Ent
= Elab_Visited
.Table
(J
) then
1542 -- See if we need to analyze this reference. We analyze it if either of
1543 -- the following conditions is met:
1545 -- It is an inner level call (since in this case it was triggered
1546 -- by an outer level call from elaboration code), but only if the
1547 -- call is within the scope of the original outer level call.
1549 -- It is an outer level reference from elaboration code, or a call to
1550 -- an entity is in the same elaboration scope.
1552 -- And in these cases, we will check both inter-unit calls and
1553 -- intra-unit (within a single unit) calls.
1555 C_Scope
:= Current_Scope
;
1557 -- If not outer level reference, then we follow it if it is within the
1558 -- original scope of the outer reference.
1560 if Present
(Outer_Scope
)
1561 and then Within
(Scope
(Ent
), Outer_Scope
)
1567 Outer_Scope
=> Outer_Scope
,
1568 Inter_Unit_Only
=> False,
1569 In_Init_Proc
=> In_Init_Proc
);
1571 -- Nothing to do if elaboration checks suppressed for this scope.
1572 -- However, an interesting exception, the fact that elaboration checks
1573 -- are suppressed within an instance (because we can trace the body when
1574 -- we process the template) does not extend to calls to generic formal
1577 elsif Elaboration_Checks_Suppressed
(Current_Scope
)
1578 and then not Is_Call_Of_Generic_Formal
(N
)
1582 elsif From_Elab_Code
then
1584 Check_A_Call
(N
, Ent
, Standard_Standard
, Inter_Unit_Only
=> False);
1586 elsif Same_Elaboration_Scope
(C_Scope
, Scope
(Ent
)) then
1588 Check_A_Call
(N
, Ent
, Scope
(Ent
), Inter_Unit_Only
=> False);
1590 -- If none of those cases holds, but Dynamic_Elaboration_Checks mode
1591 -- is set, then we will do the check, but only in the inter-unit case
1592 -- (this is to accommodate unguarded elaboration calls from other units
1593 -- in which this same mode is set). We don't want warnings in this case,
1594 -- it would generate warnings having nothing to do with elaboration.
1596 elsif Dynamic_Elaboration_Checks
then
1602 Inter_Unit_Only
=> True,
1603 Generate_Warnings
=> False);
1605 -- Otherwise nothing to do
1611 -- A call to an Init_Proc in elaboration code may bring additional
1612 -- dependencies, if some of the record components thereof have
1613 -- initializations that are function calls that come from source. We
1614 -- treat the current node as a call to each of these functions, to check
1615 -- their elaboration impact.
1617 if Is_Init_Proc
(Ent
) and then From_Elab_Code
then
1618 Process_Init_Proc
: declare
1619 Unit_Decl
: constant Node_Id
:= Unit_Declaration_Node
(Ent
);
1621 function Check_Init_Call
(Nod
: Node_Id
) return Traverse_Result
;
1622 -- Find subprogram calls within body of Init_Proc for Traverse
1623 -- instantiation below.
1625 procedure Traverse_Body
is new Traverse_Proc
(Check_Init_Call
);
1626 -- Traversal procedure to find all calls with body of Init_Proc
1628 ---------------------
1629 -- Check_Init_Call --
1630 ---------------------
1632 function Check_Init_Call
(Nod
: Node_Id
) return Traverse_Result
is
1636 if Nkind
(Nod
) in N_Subprogram_Call
1637 and then Is_Entity_Name
(Name
(Nod
))
1639 Func
:= Entity
(Name
(Nod
));
1641 if Comes_From_Source
(Func
) then
1643 (N
, Func
, Standard_Standard
, Inter_Unit_Only
=> True);
1651 end Check_Init_Call
;
1653 -- Start of processing for Process_Init_Proc
1656 if Nkind
(Unit_Decl
) = N_Subprogram_Body
then
1657 Traverse_Body
(Handled_Statement_Sequence
(Unit_Decl
));
1659 end Process_Init_Proc
;
1661 end Check_Elab_Call
;
1663 -----------------------
1664 -- Check_Elab_Assign --
1665 -----------------------
1667 procedure Check_Elab_Assign
(N
: Node_Id
) is
1671 Pkg_Spec
: Entity_Id
;
1672 Pkg_Body
: Entity_Id
;
1675 -- For record or array component, check prefix. If it is an access type,
1676 -- then there is nothing to do (we do not know what is being assigned),
1677 -- but otherwise this is an assignment to the prefix.
1679 if Nkind_In
(N
, N_Indexed_Component
,
1680 N_Selected_Component
,
1683 if not Is_Access_Type
(Etype
(Prefix
(N
))) then
1684 Check_Elab_Assign
(Prefix
(N
));
1690 -- For type conversion, check expression
1692 if Nkind
(N
) = N_Type_Conversion
then
1693 Check_Elab_Assign
(Expression
(N
));
1697 -- Nothing to do if this is not an entity reference otherwise get entity
1699 if Is_Entity_Name
(N
) then
1705 -- What we are looking for is a reference in the body of a package that
1706 -- modifies a variable declared in the visible part of the package spec.
1709 and then Comes_From_Source
(N
)
1710 and then not Suppress_Elaboration_Warnings
(Ent
)
1711 and then Ekind
(Ent
) = E_Variable
1712 and then not In_Private_Part
(Ent
)
1713 and then Is_Library_Level_Entity
(Ent
)
1715 Scop
:= Current_Scope
;
1717 if No
(Scop
) or else Scop
= Standard_Standard
then
1719 elsif Ekind
(Scop
) = E_Package
1720 and then Is_Compilation_Unit
(Scop
)
1724 Scop
:= Scope
(Scop
);
1728 -- Here Scop points to the containing library package
1731 Pkg_Body
:= Body_Entity
(Pkg_Spec
);
1733 -- All OK if the package has an Elaborate_Body pragma
1735 if Has_Pragma_Elaborate_Body
(Scop
) then
1739 -- OK if entity being modified is not in containing package spec
1741 if not In_Same_Source_Unit
(Scop
, Ent
) then
1745 -- All OK if entity appears in generic package or generic instance.
1746 -- We just get too messed up trying to give proper warnings in the
1747 -- presence of generics. Better no message than a junk one.
1749 Scop
:= Scope
(Ent
);
1750 while Present
(Scop
) and then Scop
/= Pkg_Spec
loop
1751 if Ekind
(Scop
) = E_Generic_Package
then
1753 elsif Ekind
(Scop
) = E_Package
1754 and then Is_Generic_Instance
(Scop
)
1759 Scop
:= Scope
(Scop
);
1762 -- All OK if in task, don't issue warnings there
1764 if In_Task_Activation
then
1768 -- OK if no package body
1770 if No
(Pkg_Body
) then
1774 -- OK if reference is not in package body
1776 if not In_Same_Source_Unit
(Pkg_Body
, N
) then
1780 -- OK if package body has no handled statement sequence
1783 HSS
: constant Node_Id
:=
1784 Handled_Statement_Sequence
(Declaration_Node
(Pkg_Body
));
1786 if No
(HSS
) or else not Comes_From_Source
(HSS
) then
1791 -- We definitely have a case of a modification of an entity in
1792 -- the package spec from the elaboration code of the package body.
1793 -- We may not give the warning (because there are some additional
1794 -- checks to avoid too many false positives), but it would be a good
1795 -- idea for the binder to try to keep the body elaboration close to
1796 -- the spec elaboration.
1798 Set_Elaborate_Body_Desirable
(Pkg_Spec
);
1800 -- All OK in gnat mode (we know what we are doing)
1806 -- All OK if all warnings suppressed
1808 if Warning_Mode
= Suppress
then
1812 -- All OK if elaboration checks suppressed for entity
1814 if Checks_May_Be_Suppressed
(Ent
)
1815 and then Is_Check_Suppressed
(Ent
, Elaboration_Check
)
1820 -- OK if the entity is initialized. Note that the No_Initialization
1821 -- flag usually means that the initialization has been rewritten into
1822 -- assignments, but that still counts for us.
1825 Decl
: constant Node_Id
:= Declaration_Node
(Ent
);
1827 if Nkind
(Decl
) = N_Object_Declaration
1828 and then (Present
(Expression
(Decl
))
1829 or else No_Initialization
(Decl
))
1835 -- Here is where we give the warning
1837 -- All OK if warnings suppressed on the entity
1839 if not Has_Warnings_Off
(Ent
) then
1840 Error_Msg_Sloc
:= Sloc
(Ent
);
1843 ("??& can be accessed by clients before this initialization",
1846 ("\??add Elaborate_Body to spec to ensure & is initialized",
1850 if not All_Errors_Mode
then
1851 Set_Suppress_Elaboration_Warnings
(Ent
);
1854 end Check_Elab_Assign
;
1856 ----------------------
1857 -- Check_Elab_Calls --
1858 ----------------------
1860 procedure Check_Elab_Calls
is
1862 -- If expansion is disabled, do not generate any checks. Also skip
1863 -- checks if any subunits are missing because in either case we lack the
1864 -- full information that we need, and no object file will be created in
1867 if not Expander_Active
1868 or else Is_Generic_Unit
(Cunit_Entity
(Main_Unit
))
1869 or else Subunits_Missing
1874 -- Skip delayed calls if we had any errors
1876 if Serious_Errors_Detected
= 0 then
1877 Delaying_Elab_Checks
:= False;
1878 Expander_Mode_Save_And_Set
(True);
1880 for J
in Delay_Check
.First
.. Delay_Check
.Last
loop
1881 Push_Scope
(Delay_Check
.Table
(J
).Curscop
);
1882 From_Elab_Code
:= Delay_Check
.Table
(J
).From_Elab_Code
;
1884 Check_Internal_Call_Continue
(
1885 N
=> Delay_Check
.Table
(J
).N
,
1886 E
=> Delay_Check
.Table
(J
).E
,
1887 Outer_Scope
=> Delay_Check
.Table
(J
).Outer_Scope
,
1888 Orig_Ent
=> Delay_Check
.Table
(J
).Orig_Ent
);
1893 -- Set Delaying_Elab_Checks back on for next main compilation
1895 Expander_Mode_Restore
;
1896 Delaying_Elab_Checks
:= True;
1898 end Check_Elab_Calls
;
1900 ------------------------------
1901 -- Check_Elab_Instantiation --
1902 ------------------------------
1904 procedure Check_Elab_Instantiation
1906 Outer_Scope
: Entity_Id
:= Empty
)
1911 -- Check for and deal with bad instantiation case. There is some
1912 -- duplicated code here, but we will worry about this later ???
1914 Check_Bad_Instantiation
(N
);
1916 if ABE_Is_Certain
(N
) then
1920 -- Nothing to do if we do not have an instantiation (happens in some
1921 -- error cases, and also in the formal package declaration case)
1923 if Nkind
(N
) not in N_Generic_Instantiation
then
1927 -- Nothing to do if inside a generic template
1929 if Inside_A_Generic
then
1933 -- Nothing to do if the instantiation is not in the main unit
1935 if not In_Extended_Main_Code_Unit
(N
) then
1939 Ent
:= Get_Generic_Entity
(N
);
1940 From_Elab_Code
:= not In_Subprogram_Or_Concurrent_Unit
;
1942 -- See if we need to analyze this instantiation. We analyze it if
1943 -- either of the following conditions is met:
1945 -- It is an inner level instantiation (since in this case it was
1946 -- triggered by an outer level call from elaboration code), but
1947 -- only if the instantiation is within the scope of the original
1948 -- outer level call.
1950 -- It is an outer level instantiation from elaboration code, or the
1951 -- instantiated entity is in the same elaboration scope.
1953 -- And in these cases, we will check both the inter-unit case and
1954 -- the intra-unit (within a single unit) case.
1956 C_Scope
:= Current_Scope
;
1958 if Present
(Outer_Scope
) and then Within
(Scope
(Ent
), Outer_Scope
) then
1960 Check_A_Call
(N
, Ent
, Outer_Scope
, Inter_Unit_Only
=> False);
1962 elsif From_Elab_Code
then
1964 Check_A_Call
(N
, Ent
, Standard_Standard
, Inter_Unit_Only
=> False);
1966 elsif Same_Elaboration_Scope
(C_Scope
, Scope
(Ent
)) then
1968 Check_A_Call
(N
, Ent
, Scope
(Ent
), Inter_Unit_Only
=> False);
1970 -- If none of those cases holds, but Dynamic_Elaboration_Checks mode is
1971 -- set, then we will do the check, but only in the inter-unit case (this
1972 -- is to accommodate unguarded elaboration calls from other units in
1973 -- which this same mode is set). We inhibit warnings in this case, since
1974 -- this instantiation is not occurring in elaboration code.
1976 elsif Dynamic_Elaboration_Checks
then
1982 Inter_Unit_Only
=> True,
1983 Generate_Warnings
=> False);
1988 end Check_Elab_Instantiation
;
1990 -------------------------
1991 -- Check_Internal_Call --
1992 -------------------------
1994 procedure Check_Internal_Call
1997 Outer_Scope
: Entity_Id
;
1998 Orig_Ent
: Entity_Id
)
2000 Inst_Case
: constant Boolean := Nkind
(N
) in N_Generic_Instantiation
;
2003 -- For P'Access, we want to warn if the -gnatw.f switch is set, and the
2004 -- node comes from source.
2006 if Nkind
(N
) = N_Attribute_Reference
and then
2007 (not Warn_On_Elab_Access
or else not Comes_From_Source
(N
))
2011 -- If not function or procedure call, instantiation, or 'Access, then
2012 -- ignore call (this happens in some error cases and rewriting cases).
2015 (N
, N_Function_Call
,
2016 N_Procedure_Call_Statement
,
2017 N_Attribute_Reference
)
2018 and then not Inst_Case
2022 -- Nothing to do if this is a call or instantiation that has already
2023 -- been found to be a sure ABE.
2025 elsif Nkind
(N
) /= N_Attribute_Reference
and then ABE_Is_Certain
(N
) then
2028 -- Nothing to do if errors already detected (avoid cascaded errors)
2030 elsif Serious_Errors_Detected
/= 0 then
2033 -- Nothing to do if not in full analysis mode
2035 elsif not Full_Analysis
then
2038 -- Nothing to do if analyzing in special spec-expression mode, since the
2039 -- call is not actually being made at this time.
2041 elsif In_Spec_Expression
then
2044 -- Nothing to do for call to intrinsic subprogram
2046 elsif Is_Intrinsic_Subprogram
(E
) then
2049 -- No need to trace local calls if checking task activation, because
2050 -- other local bodies are elaborated already.
2052 elsif In_Task_Activation
then
2055 -- Nothing to do if call is within a generic unit
2057 elsif Inside_A_Generic
then
2061 -- Delay this call if we are still delaying calls
2063 if Delaying_Elab_Checks
then
2064 Delay_Check
.Append
(
2067 Orig_Ent
=> Orig_Ent
,
2068 Curscop
=> Current_Scope
,
2069 Outer_Scope
=> Outer_Scope
,
2070 From_Elab_Code
=> From_Elab_Code
));
2073 -- Otherwise, call phase 2 continuation right now
2076 Check_Internal_Call_Continue
(N
, E
, Outer_Scope
, Orig_Ent
);
2078 end Check_Internal_Call
;
2080 ----------------------------------
2081 -- Check_Internal_Call_Continue --
2082 ----------------------------------
2084 procedure Check_Internal_Call_Continue
2087 Outer_Scope
: Entity_Id
;
2088 Orig_Ent
: Entity_Id
)
2090 Loc
: constant Source_Ptr
:= Sloc
(N
);
2091 Inst_Case
: constant Boolean := Is_Generic_Unit
(E
);
2096 function Find_Elab_Reference
(N
: Node_Id
) return Traverse_Result
;
2097 -- Function applied to each node as we traverse the body. Checks for
2098 -- call or entity reference that needs checking, and if so checks it.
2099 -- Always returns OK, so entire tree is traversed, except that as
2100 -- described below subprogram bodies are skipped for now.
2102 procedure Traverse
is new Atree
.Traverse_Proc
(Find_Elab_Reference
);
2103 -- Traverse procedure using above Find_Elab_Reference function
2105 -------------------------
2106 -- Find_Elab_Reference --
2107 -------------------------
2109 function Find_Elab_Reference
(N
: Node_Id
) return Traverse_Result
is
2113 -- If user has specified that there are no entry calls in elaboration
2114 -- code, do not trace past an accept statement, because the rendez-
2115 -- vous will happen after elaboration.
2117 if Nkind_In
(Original_Node
(N
), N_Accept_Statement
,
2119 and then Restriction_Active
(No_Entry_Calls_In_Elaboration_Code
)
2123 -- If we have a function call, check it
2125 elsif Nkind
(N
) = N_Function_Call
then
2126 Check_Elab_Call
(N
, Outer_Scope
);
2129 -- If we have a procedure call, check the call, and also check
2130 -- arguments that are assignments (OUT or IN OUT mode formals).
2132 elsif Nkind
(N
) = N_Procedure_Call_Statement
then
2133 Check_Elab_Call
(N
, Outer_Scope
, In_Init_Proc
=> Is_Init_Proc
(E
));
2135 Actual
:= First_Actual
(N
);
2136 while Present
(Actual
) loop
2137 if Known_To_Be_Assigned
(Actual
) then
2138 Check_Elab_Assign
(Actual
);
2141 Next_Actual
(Actual
);
2146 -- If we have an access attribute for a subprogram, check it.
2147 -- Suppress this behavior under debug flag.
2149 elsif not Debug_Flag_Dot_UU
2150 and then Nkind
(N
) = N_Attribute_Reference
2151 and then Nam_In
(Attribute_Name
(N
), Name_Access
,
2152 Name_Unrestricted_Access
)
2153 and then Is_Entity_Name
(Prefix
(N
))
2154 and then Is_Subprogram
(Entity
(Prefix
(N
)))
2156 Check_Elab_Call
(N
, Outer_Scope
);
2159 -- In SPARK mode, if we have an entity reference to a variable, then
2160 -- check it. For now we consider any reference.
2162 elsif SPARK_Mode
= On
2163 and then Nkind
(N
) in N_Has_Entity
2164 and then Present
(Entity
(N
))
2165 and then Ekind
(Entity
(N
)) = E_Variable
2167 Check_Elab_Call
(N
, Outer_Scope
);
2170 -- If we have a generic instantiation, check it
2172 elsif Nkind
(N
) in N_Generic_Instantiation
then
2173 Check_Elab_Instantiation
(N
, Outer_Scope
);
2176 -- Skip subprogram bodies that come from source (wait for call to
2177 -- analyze these). The reason for the come from source test is to
2178 -- avoid catching task bodies.
2180 -- For task bodies, we should really avoid these too, waiting for the
2181 -- task activation, but that's too much trouble to catch for now, so
2182 -- we go in unconditionally. This is not so terrible, it means the
2183 -- error backtrace is not quite complete, and we are too eager to
2184 -- scan bodies of tasks that are unused, but this is hardly very
2187 elsif Nkind
(N
) = N_Subprogram_Body
2188 and then Comes_From_Source
(N
)
2192 elsif Nkind
(N
) = N_Assignment_Statement
2193 and then Comes_From_Source
(N
)
2195 Check_Elab_Assign
(Name
(N
));
2201 end Find_Elab_Reference
;
2203 -- Start of processing for Check_Internal_Call_Continue
2206 -- Save outer level call if at outer level
2208 if Elab_Call
.Last
= 0 then
2209 Outer_Level_Sloc
:= Loc
;
2212 Elab_Visited
.Append
(E
);
2214 -- If the call is to a function that renames a literal, no check needed
2216 if Ekind
(E
) = E_Enumeration_Literal
then
2220 Sbody
:= Unit_Declaration_Node
(E
);
2222 if not Nkind_In
(Sbody
, N_Subprogram_Body
, N_Package_Body
) then
2223 Ebody
:= Corresponding_Body
(Sbody
);
2228 Sbody
:= Unit_Declaration_Node
(Ebody
);
2232 -- If the body appears after the outer level call or instantiation then
2233 -- we have an error case handled below.
2235 if Earlier_In_Extended_Unit
(Outer_Level_Sloc
, Sloc
(Sbody
))
2236 and then not In_Task_Activation
2240 -- If we have the instantiation case we are done, since we now
2241 -- know that the body of the generic appeared earlier.
2243 elsif Inst_Case
then
2246 -- Otherwise we have a call, so we trace through the called body to see
2247 -- if it has any problems.
2250 pragma Assert
(Nkind
(Sbody
) = N_Subprogram_Body
);
2252 Elab_Call
.Append
((Cloc
=> Loc
, Ent
=> E
));
2254 if Debug_Flag_LL
then
2255 Write_Str
("Elab_Call.Last = ");
2256 Write_Int
(Int
(Elab_Call
.Last
));
2257 Write_Str
(" Ent = ");
2258 Write_Name
(Chars
(E
));
2260 Write_Location
(Sloc
(N
));
2264 -- Now traverse declarations and statements of subprogram body. Note
2265 -- that we cannot simply Traverse (Sbody), since traverse does not
2266 -- normally visit subprogram bodies.
2271 Decl
:= First
(Declarations
(Sbody
));
2272 while Present
(Decl
) loop
2278 Traverse
(Handled_Statement_Sequence
(Sbody
));
2280 Elab_Call
.Decrement_Last
;
2284 -- Here is the case of calling a subprogram where the body has not yet
2285 -- been encountered. A warning message is needed, except if this is the
2286 -- case of appearing within an aspect specification that results in
2287 -- a check call, we do not really have such a situation, so no warning
2288 -- is needed (e.g. the case of a precondition, where the call appears
2289 -- textually before the body, but in actual fact is moved to the
2290 -- appropriate subprogram body and so does not need a check).
2299 -- Keep looking at parents if we are still in the subexpression
2301 if Nkind
(P
) in N_Subexpr
then
2304 -- Here P is the parent of the expression, check for special case
2307 O
:= Original_Node
(P
);
2309 -- Definitely not the special case if orig node is not a pragma
2311 exit when Nkind
(O
) /= N_Pragma
;
2313 -- Check we have an If statement or a null statement (happens
2314 -- when the If has been expanded to be True).
2316 exit when not Nkind_In
(P
, N_If_Statement
, N_Null_Statement
);
2318 -- Our special case will be indicated either by the pragma
2319 -- coming from an aspect ...
2321 if Present
(Corresponding_Aspect
(O
)) then
2324 -- Or, in the case of an initial condition, specifically by a
2325 -- Check pragma specifying an Initial_Condition check.
2327 elsif Pragma_Name
(O
) = Name_Check
2330 (Expression
(First
(Pragma_Argument_Associations
(O
)))) =
2331 Name_Initial_Condition
2335 -- For anything else, we have an error
2344 -- Not that special case, warning and dynamic check is required
2346 -- If we have nothing in the call stack, then this is at the outer
2347 -- level, and the ABE is bound to occur, unless it's a 'Access.
2349 if Elab_Call
.Last
= 0 then
2350 Error_Msg_Warn
:= SPARK_Mode
/= On
;
2354 ("cannot instantiate& before body seen<<", N
, Orig_Ent
);
2355 elsif Nkind
(N
) /= N_Attribute_Reference
then
2357 ("cannot call& before body seen<<", N
, Orig_Ent
);
2360 ("Access attribute of & before body seen<<", N
, Orig_Ent
);
2361 Error_Msg_N
("\possible Program_Error on later references<", N
);
2364 if Nkind
(N
) /= N_Attribute_Reference
then
2365 Error_Msg_N
("\Program_Error [<<", N
);
2366 Insert_Elab_Check
(N
);
2369 -- Call is not at outer level
2372 -- Deal with dynamic elaboration check
2374 if not Elaboration_Checks_Suppressed
(E
) then
2375 Set_Elaboration_Entity_Required
(E
);
2377 -- Case of no elaboration entity allocated yet
2379 if No
(Elaboration_Entity
(E
)) then
2381 -- Create object declaration for elaboration entity, and put it
2382 -- just in front of the spec of the subprogram or generic unit,
2383 -- in the same scope as this unit. The subprogram may be over-
2384 -- loaded, so make the name of elaboration entity unique by
2385 -- means of a numeric suffix.
2388 Loce
: constant Source_Ptr
:= Sloc
(E
);
2389 Ent
: constant Entity_Id
:=
2390 Make_Defining_Identifier
(Loc
,
2391 Chars
=> New_External_Name
(Chars
(E
), 'E', -1));
2394 Set_Elaboration_Entity
(E
, Ent
);
2395 Push_Scope
(Scope
(E
));
2397 Insert_Action
(Declaration_Node
(E
),
2398 Make_Object_Declaration
(Loce
,
2399 Defining_Identifier
=> Ent
,
2400 Object_Definition
=>
2401 New_Occurrence_Of
(Standard_Short_Integer
, Loce
),
2403 Make_Integer_Literal
(Loc
, Uint_0
)));
2405 -- Set elaboration flag at the point of the body
2407 Set_Elaboration_Flag
(Sbody
, E
);
2409 -- Kill current value indication. This is necessary because
2410 -- the tests of this flag are inserted out of sequence and
2411 -- must not pick up bogus indications of the wrong constant
2412 -- value. Also, this is never a true constant, since one way
2413 -- or another, it gets reset.
2415 Set_Current_Value
(Ent
, Empty
);
2416 Set_Last_Assignment
(Ent
, Empty
);
2417 Set_Is_True_Constant
(Ent
, False);
2422 -- Generate check of the elaboration counter
2424 Insert_Elab_Check
(N
,
2425 Make_Attribute_Reference
(Loc
,
2426 Attribute_Name
=> Name_Elaborated
,
2427 Prefix
=> New_Occurrence_Of
(E
, Loc
)));
2430 -- Generate the warning
2432 if not Suppress_Elaboration_Warnings
(E
)
2433 and then not Elaboration_Checks_Suppressed
(E
)
2435 -- Suppress this warning if we have a function call that occurred
2436 -- within an assertion expression, since we can get false warnings
2437 -- in this case, due to the out of order handling in this case.
2440 (Nkind
(Original_Node
(N
)) /= N_Function_Call
2441 or else not In_Assertion_Expression_Pragma
(Original_Node
(N
)))
2443 Error_Msg_Warn
:= SPARK_Mode
/= On
;
2447 ("instantiation of& may occur before body is seen<l<",
2450 -- A rather specific check. For Finalize/Adjust/Initialize,
2451 -- if the type has Warnings_Off set, suppress the warning.
2453 if Nam_In
(Chars
(E
), Name_Adjust
,
2456 and then Present
(First_Formal
(E
))
2459 T
: constant Entity_Id
:= Etype
(First_Formal
(E
));
2461 if Is_Controlled
(T
) then
2463 or else (Ekind
(T
) = E_Private_Type
2464 and then Warnings_Off
(Full_View
(T
)))
2472 -- Go ahead and give warning if not this special case
2475 ("call to& may occur before body is seen<l<", N
, Orig_Ent
);
2478 Error_Msg_N
("\Program_Error ]<l<", N
);
2480 -- There is no need to query the elaboration warning message flags
2481 -- because the main message is an error, not a warning, therefore
2482 -- all the clarification messages produces by Output_Calls must be
2483 -- emitted unconditionally.
2487 Output_Calls
(N
, Check_Elab_Flag
=> False);
2491 -- Set flag to suppress further warnings on same subprogram
2492 -- unless in all errors mode
2494 if not All_Errors_Mode
then
2495 Set_Suppress_Elaboration_Warnings
(E
);
2497 end Check_Internal_Call_Continue
;
2499 ---------------------------
2500 -- Check_Task_Activation --
2501 ---------------------------
2503 procedure Check_Task_Activation
(N
: Node_Id
) is
2504 Loc
: constant Source_Ptr
:= Sloc
(N
);
2505 Inter_Procs
: constant Elist_Id
:= New_Elmt_List
;
2506 Intra_Procs
: constant Elist_Id
:= New_Elmt_List
;
2509 Task_Scope
: Entity_Id
;
2510 Cunit_SC
: Boolean := False;
2513 Enclosing
: Entity_Id
;
2515 procedure Add_Task_Proc
(Typ
: Entity_Id
);
2516 -- Add to Task_Procs the task body procedure(s) of task types in Typ.
2517 -- For record types, this procedure recurses over component types.
2519 procedure Collect_Tasks
(Decls
: List_Id
);
2520 -- Collect the types of the tasks that are to be activated in the given
2521 -- list of declarations, in order to perform elaboration checks on the
2522 -- corresponding task procedures which are called implicitly here.
2524 function Outer_Unit
(E
: Entity_Id
) return Entity_Id
;
2525 -- find enclosing compilation unit of Entity, ignoring subunits, or
2526 -- else enclosing subprogram. If E is not a package, there is no need
2527 -- for inter-unit elaboration checks.
2533 procedure Add_Task_Proc
(Typ
: Entity_Id
) is
2535 Proc
: Entity_Id
:= Empty
;
2538 if Is_Task_Type
(Typ
) then
2539 Proc
:= Get_Task_Body_Procedure
(Typ
);
2541 elsif Is_Array_Type
(Typ
)
2542 and then Has_Task
(Base_Type
(Typ
))
2544 Add_Task_Proc
(Component_Type
(Typ
));
2546 elsif Is_Record_Type
(Typ
)
2547 and then Has_Task
(Base_Type
(Typ
))
2549 Comp
:= First_Component
(Typ
);
2550 while Present
(Comp
) loop
2551 Add_Task_Proc
(Etype
(Comp
));
2552 Comp
:= Next_Component
(Comp
);
2556 -- If the task type is another unit, we will perform the usual
2557 -- elaboration check on its enclosing unit. If the type is in the
2558 -- same unit, we can trace the task body as for an internal call,
2559 -- but we only need to examine other external calls, because at
2560 -- the point the task is activated, internal subprogram bodies
2561 -- will have been elaborated already. We keep separate lists for
2562 -- each kind of task.
2564 -- Skip this test if errors have occurred, since in this case
2565 -- we can get false indications.
2567 if Serious_Errors_Detected
/= 0 then
2571 if Present
(Proc
) then
2572 if Outer_Unit
(Scope
(Proc
)) = Enclosing
then
2574 if No
(Corresponding_Body
(Unit_Declaration_Node
(Proc
)))
2576 (not Is_Generic_Instance
(Scope
(Proc
))
2577 or else Scope
(Proc
) = Scope
(Defining_Identifier
(Decl
)))
2579 Error_Msg_Warn
:= SPARK_Mode
/= On
;
2581 ("task will be activated before elaboration of its body<<",
2583 Error_Msg_N
("\Program_Error [<<", Decl
);
2586 (Corresponding_Body
(Unit_Declaration_Node
(Proc
)))
2588 Append_Elmt
(Proc
, Intra_Procs
);
2592 -- No need for multiple entries of the same type
2594 Elmt
:= First_Elmt
(Inter_Procs
);
2595 while Present
(Elmt
) loop
2596 if Node
(Elmt
) = Proc
then
2603 Append_Elmt
(Proc
, Inter_Procs
);
2612 procedure Collect_Tasks
(Decls
: List_Id
) is
2614 if Present
(Decls
) then
2615 Decl
:= First
(Decls
);
2616 while Present
(Decl
) loop
2617 if Nkind
(Decl
) = N_Object_Declaration
2618 and then Has_Task
(Etype
(Defining_Identifier
(Decl
)))
2620 Add_Task_Proc
(Etype
(Defining_Identifier
(Decl
)));
2632 function Outer_Unit
(E
: Entity_Id
) return Entity_Id
is
2637 while Present
(Outer
) loop
2638 if Elaboration_Checks_Suppressed
(Outer
) then
2642 exit when Is_Child_Unit
(Outer
)
2643 or else Scope
(Outer
) = Standard_Standard
2644 or else Ekind
(Outer
) /= E_Package
;
2645 Outer
:= Scope
(Outer
);
2651 -- Start of processing for Check_Task_Activation
2654 Enclosing
:= Outer_Unit
(Current_Scope
);
2656 -- Find all tasks declared in the current unit
2658 if Nkind
(N
) = N_Package_Body
then
2659 P
:= Unit_Declaration_Node
(Corresponding_Spec
(N
));
2661 Collect_Tasks
(Declarations
(N
));
2662 Collect_Tasks
(Visible_Declarations
(Specification
(P
)));
2663 Collect_Tasks
(Private_Declarations
(Specification
(P
)));
2665 elsif Nkind
(N
) = N_Package_Declaration
then
2666 Collect_Tasks
(Visible_Declarations
(Specification
(N
)));
2667 Collect_Tasks
(Private_Declarations
(Specification
(N
)));
2670 Collect_Tasks
(Declarations
(N
));
2673 -- We only perform detailed checks in all tasks that are library level
2674 -- entities. If the master is a subprogram or task, activation will
2675 -- depend on the activation of the master itself.
2677 -- Should dynamic checks be added in the more general case???
2679 if Ekind
(Enclosing
) /= E_Package
then
2683 -- For task types defined in other units, we want the unit containing
2684 -- the task body to be elaborated before the current one.
2686 Elmt
:= First_Elmt
(Inter_Procs
);
2687 while Present
(Elmt
) loop
2689 Task_Scope
:= Outer_Unit
(Scope
(Ent
));
2691 if not Is_Compilation_Unit
(Task_Scope
) then
2694 elsif Suppress_Elaboration_Warnings
(Task_Scope
)
2695 or else Elaboration_Checks_Suppressed
(Task_Scope
)
2699 elsif Dynamic_Elaboration_Checks
then
2700 if not Elaboration_Checks_Suppressed
(Ent
)
2701 and then not Cunit_SC
2703 not Restriction_Active
(No_Entry_Calls_In_Elaboration_Code
)
2705 -- Runtime elaboration check required. Generate check of the
2706 -- elaboration counter for the unit containing the entity.
2708 Insert_Elab_Check
(N
,
2709 Make_Attribute_Reference
(Loc
,
2710 Attribute_Name
=> Name_Elaborated
,
2712 New_Occurrence_Of
(Spec_Entity
(Task_Scope
), Loc
)));
2716 -- Force the binder to elaborate other unit first
2718 if not Suppress_Elaboration_Warnings
(Ent
)
2719 and then not Elaboration_Checks_Suppressed
(Ent
)
2720 and then Elab_Info_Messages
2721 and then not Suppress_Elaboration_Warnings
(Task_Scope
)
2722 and then not Elaboration_Checks_Suppressed
(Task_Scope
)
2724 Error_Msg_Node_2
:= Task_Scope
;
2726 ("info: activation of an instance of task type&" &
2727 " requires pragma Elaborate_All on &?$?", N
, Ent
);
2730 Activate_Elaborate_All_Desirable
(N
, Task_Scope
);
2731 Set_Suppress_Elaboration_Warnings
(Task_Scope
);
2737 -- For tasks declared in the current unit, trace other calls within
2738 -- the task procedure bodies, which are available.
2740 In_Task_Activation
:= True;
2742 Elmt
:= First_Elmt
(Intra_Procs
);
2743 while Present
(Elmt
) loop
2745 Check_Internal_Call_Continue
(N
, Ent
, Enclosing
, Ent
);
2749 In_Task_Activation
:= False;
2750 end Check_Task_Activation
;
2752 -------------------------------
2753 -- Is_Call_Of_Generic_Formal --
2754 -------------------------------
2756 function Is_Call_Of_Generic_Formal
(N
: Node_Id
) return Boolean is
2758 return Nkind_In
(N
, N_Function_Call
, N_Procedure_Call_Statement
)
2760 -- Always return False if debug flag -gnatd.G is set
2762 and then not Debug_Flag_Dot_GG
2764 -- For now, we detect this by looking for the strange identifier
2765 -- node, whose Chars reflect the name of the generic formal, but
2766 -- the Chars of the Entity references the generic actual.
2768 and then Nkind
(Name
(N
)) = N_Identifier
2769 and then Chars
(Name
(N
)) /= Chars
(Entity
(Name
(N
)));
2770 end Is_Call_Of_Generic_Formal
;
2772 --------------------------------
2773 -- Set_Elaboration_Constraint --
2774 --------------------------------
2776 procedure Set_Elaboration_Constraint
2781 Elab_Unit
: Entity_Id
;
2783 -- Check whether this is a call to an Initialize subprogram for a
2784 -- controlled type. Note that Call can also be a 'Access attribute
2785 -- reference, which now generates an elaboration check.
2787 Init_Call
: constant Boolean :=
2788 Nkind
(Call
) = N_Procedure_Call_Statement
2789 and then Chars
(Subp
) = Name_Initialize
2790 and then Comes_From_Source
(Subp
)
2791 and then Present
(Parameter_Associations
(Call
))
2792 and then Is_Controlled
(Etype
(First_Actual
(Call
)));
2794 -- If the unit is mentioned in a with_clause of the current unit, it is
2795 -- visible, and we can set the elaboration flag.
2797 if Is_Immediately_Visible
(Scop
)
2798 or else (Is_Child_Unit
(Scop
) and then Is_Visible_Lib_Unit
(Scop
))
2800 Activate_Elaborate_All_Desirable
(Call
, Scop
);
2801 Set_Suppress_Elaboration_Warnings
(Scop
, True);
2805 -- If this is not an initialization call or a call using object notation
2806 -- we know that the unit of the called entity is in the context, and
2807 -- we can set the flag as well. The unit need not be visible if the call
2808 -- occurs within an instantiation.
2810 if Is_Init_Proc
(Subp
)
2812 or else Nkind
(Original_Node
(Call
)) = N_Selected_Component
2814 null; -- detailed processing follows.
2817 Activate_Elaborate_All_Desirable
(Call
, Scop
);
2818 Set_Suppress_Elaboration_Warnings
(Scop
, True);
2822 -- If the unit is not in the context, there must be an intermediate unit
2823 -- that is, on which we need to place to elaboration flag. This happens
2824 -- with init proc calls.
2826 if Is_Init_Proc
(Subp
) or else Init_Call
then
2828 -- The initialization call is on an object whose type is not declared
2829 -- in the same scope as the subprogram. The type of the object must
2830 -- be a subtype of the type of operation. This object is the first
2831 -- actual in the call.
2834 Typ
: constant Entity_Id
:=
2835 Etype
(First
(Parameter_Associations
(Call
)));
2837 Elab_Unit
:= Scope
(Typ
);
2838 while (Present
(Elab_Unit
))
2839 and then not Is_Compilation_Unit
(Elab_Unit
)
2841 Elab_Unit
:= Scope
(Elab_Unit
);
2845 -- If original node uses selected component notation, the prefix is
2846 -- visible and determines the scope that must be elaborated. After
2847 -- rewriting, the prefix is the first actual in the call.
2849 elsif Nkind
(Original_Node
(Call
)) = N_Selected_Component
then
2850 Elab_Unit
:= Scope
(Etype
(First
(Parameter_Associations
(Call
))));
2852 -- Not one of special cases above
2855 -- Using previously computed scope. If the elaboration check is
2856 -- done after analysis, the scope is not visible any longer, but
2857 -- must still be in the context.
2862 Activate_Elaborate_All_Desirable
(Call
, Elab_Unit
);
2863 Set_Suppress_Elaboration_Warnings
(Elab_Unit
, True);
2864 end Set_Elaboration_Constraint
;
2866 ------------------------
2867 -- Get_Referenced_Ent --
2868 ------------------------
2870 function Get_Referenced_Ent
(N
: Node_Id
) return Entity_Id
is
2874 if Nkind
(N
) in N_Has_Entity
2875 and then Present
(Entity
(N
))
2876 and then Ekind
(Entity
(N
)) = E_Variable
2881 if Nkind
(N
) = N_Attribute_Reference
then
2889 elsif Nkind
(Nam
) = N_Selected_Component
then
2890 return Entity
(Selector_Name
(Nam
));
2891 elsif not Is_Entity_Name
(Nam
) then
2894 return Entity
(Nam
);
2896 end Get_Referenced_Ent
;
2898 ----------------------
2899 -- Has_Generic_Body --
2900 ----------------------
2902 function Has_Generic_Body
(N
: Node_Id
) return Boolean is
2903 Ent
: constant Entity_Id
:= Get_Generic_Entity
(N
);
2904 Decl
: constant Node_Id
:= Unit_Declaration_Node
(Ent
);
2907 function Find_Body_In
(E
: Entity_Id
; N
: Node_Id
) return Node_Id
;
2908 -- Determine if the list of nodes headed by N and linked by Next
2909 -- contains a package body for the package spec entity E, and if so
2910 -- return the package body. If not, then returns Empty.
2912 function Load_Package_Body
(Nam
: Unit_Name_Type
) return Node_Id
;
2913 -- This procedure is called load the unit whose name is given by Nam.
2914 -- This unit is being loaded to see whether it contains an optional
2915 -- generic body. The returned value is the loaded unit, which is always
2916 -- a package body (only package bodies can contain other entities in the
2917 -- sense in which Has_Generic_Body is interested). We only attempt to
2918 -- load bodies if we are generating code. If we are in semantics check
2919 -- only mode, then it would be wrong to load bodies that are not
2920 -- required from a semantic point of view, so in this case we return
2921 -- Empty. The result is that the caller may incorrectly decide that a
2922 -- generic spec does not have a body when in fact it does, but the only
2923 -- harm in this is that some warnings on elaboration problems may be
2924 -- lost in semantic checks only mode, which is not big loss. We also
2925 -- return Empty if we go for a body and it is not there.
2927 function Locate_Corresponding_Body
(PE
: Entity_Id
) return Node_Id
;
2928 -- PE is the entity for a package spec. This function locates the
2929 -- corresponding package body, returning Empty if none is found. The
2930 -- package body returned is fully parsed but may not yet be analyzed,
2931 -- so only syntactic fields should be referenced.
2937 function Find_Body_In
(E
: Entity_Id
; N
: Node_Id
) return Node_Id
is
2942 while Present
(Nod
) loop
2944 -- If we found the package body we are looking for, return it
2946 if Nkind
(Nod
) = N_Package_Body
2947 and then Chars
(Defining_Unit_Name
(Nod
)) = Chars
(E
)
2951 -- If we found the stub for the body, go after the subunit,
2952 -- loading it if necessary.
2954 elsif Nkind
(Nod
) = N_Package_Body_Stub
2955 and then Chars
(Defining_Identifier
(Nod
)) = Chars
(E
)
2957 if Present
(Library_Unit
(Nod
)) then
2958 return Unit
(Library_Unit
(Nod
));
2961 return Load_Package_Body
(Get_Unit_Name
(Nod
));
2964 -- If neither package body nor stub, keep looking on chain
2974 -----------------------
2975 -- Load_Package_Body --
2976 -----------------------
2978 function Load_Package_Body
(Nam
: Unit_Name_Type
) return Node_Id
is
2979 U
: Unit_Number_Type
;
2982 if Operating_Mode
/= Generate_Code
then
2995 return Unit
(Cunit
(U
));
2998 end Load_Package_Body
;
3000 -------------------------------
3001 -- Locate_Corresponding_Body --
3002 -------------------------------
3004 function Locate_Corresponding_Body
(PE
: Entity_Id
) return Node_Id
is
3005 Spec
: constant Node_Id
:= Declaration_Node
(PE
);
3006 Decl
: constant Node_Id
:= Parent
(Spec
);
3007 Scop
: constant Entity_Id
:= Scope
(PE
);
3011 if Is_Library_Level_Entity
(PE
) then
3013 -- If package is a library unit that requires a body, we have no
3014 -- choice but to go after that body because it might contain an
3015 -- optional body for the original generic package.
3017 if Unit_Requires_Body
(PE
) then
3019 -- Load the body. Note that we are a little careful here to use
3020 -- Spec to get the unit number, rather than PE or Decl, since
3021 -- in the case where the package is itself a library level
3022 -- instantiation, Spec will properly reference the generic
3023 -- template, which is what we really want.
3027 (Get_Body_Name
(Unit_Name
(Get_Source_Unit
(Spec
))));
3029 -- But if the package is a library unit that does NOT require
3030 -- a body, then no body is permitted, so we are sure that there
3031 -- is no body for the original generic package.
3037 -- Otherwise look and see if we are embedded in a further package
3039 elsif Is_Package_Or_Generic_Package
(Scop
) then
3041 -- If so, get the body of the enclosing package, and look in
3042 -- its package body for the package body we are looking for.
3044 PBody
:= Locate_Corresponding_Body
(Scop
);
3049 return Find_Body_In
(PE
, First
(Declarations
(PBody
)));
3052 -- If we are not embedded in a further package, then the body
3053 -- must be in the same declarative part as we are.
3056 return Find_Body_In
(PE
, Next
(Decl
));
3058 end Locate_Corresponding_Body
;
3060 -- Start of processing for Has_Generic_Body
3063 if Present
(Corresponding_Body
(Decl
)) then
3066 elsif Unit_Requires_Body
(Ent
) then
3069 -- Compilation units cannot have optional bodies
3071 elsif Is_Compilation_Unit
(Ent
) then
3074 -- Otherwise look at what scope we are in
3077 Scop
:= Scope
(Ent
);
3079 -- Case of entity is in other than a package spec, in this case
3080 -- the body, if present, must be in the same declarative part.
3082 if not Is_Package_Or_Generic_Package
(Scop
) then
3087 -- Declaration node may get us a spec, so if so, go to
3088 -- the parent declaration.
3090 P
:= Declaration_Node
(Ent
);
3091 while not Is_List_Member
(P
) loop
3095 return Present
(Find_Body_In
(Ent
, Next
(P
)));
3098 -- If the entity is in a package spec, then we have to locate
3099 -- the corresponding package body, and look there.
3103 PBody
: constant Node_Id
:= Locate_Corresponding_Body
(Scop
);
3111 (Find_Body_In
(Ent
, (First
(Declarations
(PBody
)))));
3116 end Has_Generic_Body
;
3118 -----------------------
3119 -- Insert_Elab_Check --
3120 -----------------------
3122 procedure Insert_Elab_Check
(N
: Node_Id
; C
: Node_Id
:= Empty
) is
3124 Loc
: constant Source_Ptr
:= Sloc
(N
);
3127 -- The check (N_Raise_Program_Error) node to be inserted
3130 -- If expansion is disabled, do not generate any checks. Also
3131 -- skip checks if any subunits are missing because in either
3132 -- case we lack the full information that we need, and no object
3133 -- file will be created in any case.
3135 if not Expander_Active
or else Subunits_Missing
then
3139 -- If we have a generic instantiation, where Instance_Spec is set,
3140 -- then this field points to a generic instance spec that has
3141 -- been inserted before the instantiation node itself, so that
3142 -- is where we want to insert a check.
3144 if Nkind
(N
) in N_Generic_Instantiation
3145 and then Present
(Instance_Spec
(N
))
3147 Nod
:= Instance_Spec
(N
);
3152 -- Build check node, possibly with condition
3155 Make_Raise_Program_Error
(Loc
, Reason
=> PE_Access_Before_Elaboration
);
3158 Set_Condition
(Chk
, Make_Op_Not
(Loc
, Right_Opnd
=> C
));
3161 -- If we are inserting at the top level, insert in Aux_Decls
3163 if Nkind
(Parent
(Nod
)) = N_Compilation_Unit
then
3165 ADN
: constant Node_Id
:= Aux_Decls_Node
(Parent
(Nod
));
3168 if No
(Declarations
(ADN
)) then
3169 Set_Declarations
(ADN
, New_List
(Chk
));
3171 Append_To
(Declarations
(ADN
), Chk
);
3177 -- Otherwise just insert as an action on the node in question
3180 Insert_Action
(Nod
, Chk
);
3182 end Insert_Elab_Check
;
3184 -------------------------------
3185 -- Is_Finalization_Procedure --
3186 -------------------------------
3188 function Is_Finalization_Procedure
(Id
: Entity_Id
) return Boolean is
3190 -- Check whether Id is a procedure with at least one parameter
3192 if Ekind
(Id
) = E_Procedure
and then Present
(First_Formal
(Id
)) then
3194 Typ
: constant Entity_Id
:= Etype
(First_Formal
(Id
));
3195 Deep_Fin
: Entity_Id
:= Empty
;
3196 Fin
: Entity_Id
:= Empty
;
3199 -- If the type of the first formal does not require finalization
3200 -- actions, then this is definitely not [Deep_]Finalize.
3202 if not Needs_Finalization
(Typ
) then
3206 -- At this point we have the following scenario:
3208 -- procedure Name (Param1 : [in] [out] Ctrl[; Param2 : ...]);
3210 -- Recover the two possible versions of [Deep_]Finalize using the
3211 -- type of the first parameter and compare with the input.
3213 Deep_Fin
:= TSS
(Typ
, TSS_Deep_Finalize
);
3215 if Is_Controlled
(Typ
) then
3216 Fin
:= Find_Prim_Op
(Typ
, Name_Finalize
);
3219 return (Present
(Deep_Fin
) and then Id
= Deep_Fin
)
3220 or else (Present
(Fin
) and then Id
= Fin
);
3225 end Is_Finalization_Procedure
;
3231 procedure Output_Calls
3233 Check_Elab_Flag
: Boolean)
3235 function Emit
(Flag
: Boolean) return Boolean;
3236 -- Determine whether to emit an error message based on the combination
3237 -- of flags Check_Elab_Flag and Flag.
3239 function Is_Printable_Error_Name
(Nm
: Name_Id
) return Boolean;
3240 -- An internal function, used to determine if a name, Nm, is either
3241 -- a non-internal name, or is an internal name that is printable
3242 -- by the error message circuits (i.e. it has a single upper
3243 -- case letter at the end).
3249 function Emit
(Flag
: Boolean) return Boolean is
3251 if Check_Elab_Flag
then
3258 -----------------------------
3259 -- Is_Printable_Error_Name --
3260 -----------------------------
3262 function Is_Printable_Error_Name
(Nm
: Name_Id
) return Boolean is
3264 if not Is_Internal_Name
(Nm
) then
3267 elsif Name_Len
= 1 then
3271 Name_Len
:= Name_Len
- 1;
3272 return not Is_Internal_Name
;
3274 end Is_Printable_Error_Name
;
3280 -- Start of processing for Output_Calls
3283 for J
in reverse 1 .. Elab_Call
.Last
loop
3284 Error_Msg_Sloc
:= Elab_Call
.Table
(J
).Cloc
;
3286 Ent
:= Elab_Call
.Table
(J
).Ent
;
3288 -- Dynamic elaboration model, warnings controlled by -gnatwl
3290 if Dynamic_Elaboration_Checks
then
3291 if Emit
(Elab_Warnings
) then
3292 if Is_Generic_Unit
(Ent
) then
3293 Error_Msg_NE
("\\?l?& instantiated #", N
, Ent
);
3294 elsif Is_Init_Proc
(Ent
) then
3295 Error_Msg_N
("\\?l?initialization procedure called #", N
);
3296 elsif Is_Printable_Error_Name
(Chars
(Ent
)) then
3297 Error_Msg_NE
("\\?l?& called #", N
, Ent
);
3299 Error_Msg_N
("\\?l?called #", N
);
3303 -- Static elaboration model, info messages controlled by -gnatel
3306 if Emit
(Elab_Info_Messages
) then
3307 if Is_Generic_Unit
(Ent
) then
3308 Error_Msg_NE
("\\?$?& instantiated #", N
, Ent
);
3309 elsif Is_Init_Proc
(Ent
) then
3310 Error_Msg_N
("\\?$?initialization procedure called #", N
);
3311 elsif Is_Printable_Error_Name
(Chars
(Ent
)) then
3312 Error_Msg_NE
("\\?$?& called #", N
, Ent
);
3314 Error_Msg_N
("\\?$?called #", N
);
3321 ----------------------------
3322 -- Same_Elaboration_Scope --
3323 ----------------------------
3325 function Same_Elaboration_Scope
(Scop1
, Scop2
: Entity_Id
) return Boolean is
3330 -- Find elaboration scope for Scop1
3331 -- This is either a subprogram or a compilation unit.
3334 while S1
/= Standard_Standard
3335 and then not Is_Compilation_Unit
(S1
)
3336 and then Ekind_In
(S1
, E_Package
, E_Protected_Type
, E_Block
)
3341 -- Find elaboration scope for Scop2
3344 while S2
/= Standard_Standard
3345 and then not Is_Compilation_Unit
(S2
)
3346 and then Ekind_In
(S2
, E_Package
, E_Protected_Type
, E_Block
)
3352 end Same_Elaboration_Scope
;
3358 procedure Set_C_Scope
is
3360 while not Is_Compilation_Unit
(C_Scope
) loop
3361 C_Scope
:= Scope
(C_Scope
);
3369 function Spec_Entity
(E
: Entity_Id
) return Entity_Id
is
3373 -- Check for case of body entity
3374 -- Why is the check for E_Void needed???
3376 if Ekind_In
(E
, E_Void
, E_Subprogram_Body
, E_Package_Body
) then
3380 Decl
:= Parent
(Decl
);
3381 exit when Nkind
(Decl
) in N_Proper_Body
;
3384 return Corresponding_Spec
(Decl
);
3395 procedure Supply_Bodies
(N
: Node_Id
) is
3397 if Nkind
(N
) = N_Subprogram_Declaration
then
3399 Ent
: constant Entity_Id
:= Defining_Unit_Name
(Specification
(N
));
3402 -- Internal subprograms will already have a generated body, so
3403 -- there is no need to provide a stub for them.
3405 if No
(Corresponding_Body
(N
)) then
3407 Loc
: constant Source_Ptr
:= Sloc
(N
);
3409 Formals
: constant List_Id
:= Copy_Parameter_List
(Ent
);
3410 Nam
: constant Entity_Id
:=
3411 Make_Defining_Identifier
(Loc
, Chars
(Ent
));
3413 Stats
: constant List_Id
:=
3415 (Make_Raise_Program_Error
(Loc
,
3416 Reason
=> PE_Access_Before_Elaboration
));
3419 if Ekind
(Ent
) = E_Function
then
3421 Make_Function_Specification
(Loc
,
3422 Defining_Unit_Name
=> Nam
,
3423 Parameter_Specifications
=> Formals
,
3424 Result_Definition
=>
3426 (Result_Definition
(Specification
(N
))));
3428 -- We cannot reliably make a return statement for this
3429 -- body, but none is needed because the call raises
3432 Set_Return_Present
(Ent
);
3436 Make_Procedure_Specification
(Loc
,
3437 Defining_Unit_Name
=> Nam
,
3438 Parameter_Specifications
=> Formals
);
3441 B
:= Make_Subprogram_Body
(Loc
,
3442 Specification
=> Spec
,
3443 Declarations
=> New_List
,
3444 Handled_Statement_Sequence
=>
3445 Make_Handled_Sequence_Of_Statements
(Loc
, Stats
));
3446 Insert_After
(N
, B
);
3452 elsif Nkind
(N
) = N_Package_Declaration
then
3454 Spec
: constant Node_Id
:= Specification
(N
);
3456 Push_Scope
(Defining_Unit_Name
(Spec
));
3457 Supply_Bodies
(Visible_Declarations
(Spec
));
3458 Supply_Bodies
(Private_Declarations
(Spec
));
3464 procedure Supply_Bodies
(L
: List_Id
) is
3469 while Present
(Elmt
) loop
3470 Supply_Bodies
(Elmt
);
3480 function Within
(E1
, E2
: Entity_Id
) return Boolean is
3487 elsif Scop
= Standard_Standard
then
3490 Scop
:= Scope
(Scop
);
3495 --------------------------
3496 -- Within_Elaborate_All --
3497 --------------------------
3499 function Within_Elaborate_All
3500 (Unit
: Unit_Number_Type
;
3501 E
: Entity_Id
) return Boolean
3503 type Unit_Number_Set
is array (Main_Unit
.. Last_Unit
) of Boolean;
3504 pragma Pack
(Unit_Number_Set
);
3506 Seen
: Unit_Number_Set
:= (others => False);
3507 -- Seen (X) is True after we have seen unit X in the walk. This is used
3508 -- to prevent processing the same unit more than once.
3510 Result
: Boolean := False;
3512 procedure Helper
(Unit
: Unit_Number_Type
);
3513 -- This helper procedure does all the work for Within_Elaborate_All. It
3514 -- walks the dependency graph, and sets Result to True if it finds an
3515 -- appropriate Elaborate_All.
3521 procedure Helper
(Unit
: Unit_Number_Type
) is
3522 CU
: constant Node_Id
:= Cunit
(Unit
);
3526 Elab_Id
: Entity_Id
;
3533 Seen
(Unit
) := True;
3536 -- First, check for Elaborate_Alls on this unit
3538 Item
:= First
(Context_Items
(CU
));
3539 while Present
(Item
) loop
3540 if Nkind
(Item
) = N_Pragma
3541 and then Pragma_Name
(Item
) = Name_Elaborate_All
3543 -- Return if some previous error on the pragma itself. The
3544 -- pragma may be unanalyzed, because of a previous error, or
3545 -- if it is the context of a subunit, inherited by its parent.
3547 if Error_Posted
(Item
) or else not Analyzed
(Item
) then
3553 (Expression
(First
(Pragma_Argument_Associations
(Item
))));
3560 Par
:= Parent
(Unit_Declaration_Node
(Elab_Id
));
3562 Item2
:= First
(Context_Items
(Par
));
3563 while Present
(Item2
) loop
3564 if Nkind
(Item2
) = N_With_Clause
3565 and then Entity
(Name
(Item2
)) = E
3566 and then not Limited_Present
(Item2
)
3579 -- Second, recurse on with's. We could do this as part of the above
3580 -- loop, but it's probably more efficient to have two loops, because
3581 -- the relevant Elaborate_All is likely to be on the initial unit. In
3582 -- other words, we're walking the with's breadth-first. This part is
3583 -- only necessary in the dynamic elaboration model.
3585 if Dynamic_Elaboration_Checks
then
3586 Item
:= First
(Context_Items
(CU
));
3587 while Present
(Item
) loop
3588 if Nkind
(Item
) = N_With_Clause
3589 and then not Limited_Present
(Item
)
3591 -- Note: the following call to Get_Cunit_Unit_Number does a
3592 -- linear search, which could be slow, but it's OK because
3593 -- we're about to give a warning anyway. Also, there might
3594 -- be hundreds of units, but not millions. If it turns out
3595 -- to be a problem, we could store the Get_Cunit_Unit_Number
3596 -- in each N_Compilation_Unit node, but that would involve
3597 -- rearranging N_Compilation_Unit_Aux to make room.
3599 Helper
(Get_Cunit_Unit_Number
(Library_Unit
(Item
)));
3611 -- Start of processing for Within_Elaborate_All
3616 end Within_Elaborate_All
;