fixing pr42337
[official-gcc.git] / gcc / ada / binde.adb
blob3a85ae85e113377556c543d0d3495a4e4284cec2
1 ------------------------------------------------------------------------------
2 -- --
3 -- GNAT COMPILER COMPONENTS --
4 -- --
5 -- B I N D E --
6 -- --
7 -- B o d y --
8 -- --
9 -- Copyright (C) 1992-2009, Free Software Foundation, Inc. --
10 -- --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License --
17 -- for more details. You should have received a copy of the GNU General --
18 -- Public License distributed with GNAT; see file COPYING3. If not, go to --
19 -- http://www.gnu.org/licenses for a complete copy of the license. --
20 -- --
21 -- GNAT was originally developed by the GNAT team at New York University. --
22 -- Extensive contributions were provided by Ada Core Technologies Inc. --
23 -- --
24 ------------------------------------------------------------------------------
26 with Binderr; use Binderr;
27 with Butil; use Butil;
28 with Debug; use Debug;
29 with Fname; use Fname;
30 with Namet; use Namet;
31 with Opt; use Opt;
32 with Osint;
33 with Output; use Output;
34 with Targparm; use Targparm;
36 with System.Case_Util; use System.Case_Util;
38 package body Binde is
40 -- The following data structures are used to represent the graph that is
41 -- used to determine the elaboration order (using a topological sort).
43 -- The following structures are used to record successors. If A is a
44 -- successor of B in this table, it means that A must be elaborated
45 -- before B is elaborated.
47 type Successor_Id is new Nat;
48 -- Identification of single successor entry
50 No_Successor : constant Successor_Id := 0;
51 -- Used to indicate end of list of successors
53 type Elab_All_Id is new Nat;
54 -- Identification of Elab_All entry link
56 No_Elab_All_Link : constant Elab_All_Id := 0;
57 -- Used to indicate end of list
59 -- Succ_Reason indicates the reason for a particular elaboration link
61 type Succ_Reason is
62 (Withed,
63 -- After directly with's Before, so the spec of Before must be
64 -- elaborated before After is elaborated.
66 Elab,
67 -- After directly mentions Before in a pragma Elaborate, so the
68 -- body of Before must be elaborate before After is elaborated.
70 Elab_All,
71 -- After either mentions Before directly in a pragma Elaborate_All,
72 -- or mentions a third unit, X, which itself requires that Before be
73 -- elaborated before unit X is elaborated. The Elab_All_Link list
74 -- traces the dependencies in the latter case.
76 Elab_All_Desirable,
77 -- This is just like Elab_All, except that the elaborate all was not
78 -- explicitly present in the source, but rather was created by the
79 -- front end, which decided that it was "desirable".
81 Elab_Desirable,
82 -- This is just like Elab, except that the elaborate was not
83 -- explicitly present in the source, but rather was created by the
84 -- front end, which decided that it was "desirable".
86 Spec_First);
87 -- After is a body, and Before is the corresponding spec
89 -- Successor_Link contains the information for one link
91 type Successor_Link is record
92 Before : Unit_Id;
93 -- Predecessor unit
95 After : Unit_Id;
96 -- Successor unit
98 Next : Successor_Id;
99 -- Next successor on this list
101 Reason : Succ_Reason;
102 -- Reason for this link
104 Elab_Body : Boolean;
105 -- Set True if this link is needed for the special Elaborate_Body
106 -- processing described below.
108 Reason_Unit : Unit_Id;
109 -- For Reason = Elab, or Elab_All or Elab_Desirable, records the unit
110 -- containing the pragma leading to the link.
112 Elab_All_Link : Elab_All_Id;
113 -- If Reason = Elab_All or Elab_Desirable, then this points to the
114 -- first elment in a list of Elab_All entries that record the with
115 -- chain leading resulting in this particular dependency.
117 end record;
119 -- Note on handling of Elaborate_Body. Basically, if we have a pragma
120 -- Elaborate_Body in a unit, it means that the spec and body have to
121 -- be handled as a single entity from the point of view of determining
122 -- an elaboration order. What we do is to essentially remove the body
123 -- from consideration completely, and transfer all its links (other
124 -- than the spec link) to the spec. Then when then the spec gets chosen,
125 -- we choose the body right afterwards. We mark the links that get moved
126 -- from the body to the spec by setting their Elab_Body flag True, so
127 -- that we can understand what is going on!
129 Succ_First : constant := 1;
131 package Succ is new Table.Table (
132 Table_Component_Type => Successor_Link,
133 Table_Index_Type => Successor_Id,
134 Table_Low_Bound => Succ_First,
135 Table_Initial => 500,
136 Table_Increment => 200,
137 Table_Name => "Succ");
139 -- For the case of Elaborate_All, the following table is used to record
140 -- chains of with relationships that lead to the Elab_All link. These
141 -- are used solely for diagnostic purposes
143 type Elab_All_Entry is record
144 Needed_By : Unit_Name_Type;
145 -- Name of unit from which referencing unit was with'ed or otherwise
146 -- needed as a result of Elaborate_All or Elaborate_Desirable.
148 Next_Elab : Elab_All_Id;
149 -- Link to next entry on chain (No_Elab_All_Link marks end of list)
150 end record;
152 package Elab_All_Entries is new Table.Table (
153 Table_Component_Type => Elab_All_Entry,
154 Table_Index_Type => Elab_All_Id,
155 Table_Low_Bound => 1,
156 Table_Initial => 2000,
157 Table_Increment => 200,
158 Table_Name => "Elab_All_Entries");
160 -- A Unit_Node record is built for each active unit
162 type Unit_Node_Record is record
164 Successors : Successor_Id;
165 -- Pointer to list of links for successor nodes
167 Num_Pred : Int;
168 -- Number of predecessors for this unit. Normally non-negative, but
169 -- can go negative in the case of units chosen by the diagnose error
170 -- procedure (when cycles are being removed from the graph).
172 Nextnp : Unit_Id;
173 -- Forward pointer for list of units with no predecessors
175 Elab_Order : Nat;
176 -- Position in elaboration order (zero = not placed yet)
178 Visited : Boolean;
179 -- Used in computing transitive closure for elaborate all and
180 -- also in locating cycles and paths in the diagnose routines.
182 Elab_Position : Natural;
183 -- Initialized to zero. Set non-zero when a unit is chosen and
184 -- placed in the elaboration order. The value represents the
185 -- ordinal position in the elaboration order.
187 end record;
189 package UNR is new Table.Table (
190 Table_Component_Type => Unit_Node_Record,
191 Table_Index_Type => Unit_Id,
192 Table_Low_Bound => First_Unit_Entry,
193 Table_Initial => 500,
194 Table_Increment => 200,
195 Table_Name => "UNR");
197 No_Pred : Unit_Id;
198 -- Head of list of items with no predecessors
200 Num_Left : Int;
201 -- Number of entries not yet dealt with
203 Cur_Unit : Unit_Id;
204 -- Current unit, set by Gather_Dependencies, and picked up in Build_Link
205 -- to set the Reason_Unit field of the created dependency link.
207 Num_Chosen : Natural := 0;
208 -- Number of units chosen in the elaboration order so far
210 -----------------------
211 -- Local Subprograms --
212 -----------------------
214 function Better_Choice (U1, U2 : Unit_Id) return Boolean;
215 -- U1 and U2 are both permitted candidates for selection as the next unit
216 -- to be elaborated. This function determines whether U1 is a better choice
217 -- than U2, i.e. should be elaborated in preference to U2, based on a set
218 -- of heuristics that establish a friendly and predictable order (see body
219 -- for details). The result is True if U1 is a better choice than U2, and
220 -- False if it is a worse choice, or there is no preference between them.
222 procedure Build_Link
223 (Before : Unit_Id;
224 After : Unit_Id;
225 R : Succ_Reason;
226 Ea_Id : Elab_All_Id := No_Elab_All_Link);
227 -- Establish a successor link, Before must be elaborated before After,
228 -- and the reason for the link is R. Ea_Id is the contents to be placed
229 -- in the Elab_All_Link of the entry.
231 procedure Choose (Chosen : Unit_Id);
232 -- Chosen is the next entry chosen in the elaboration order. This
233 -- procedure updates all data structures appropriately.
235 function Corresponding_Body (U : Unit_Id) return Unit_Id;
236 pragma Inline (Corresponding_Body);
237 -- Given a unit which is a spec for which there is a separate body,
238 -- return the unit id of the body. It is an error to call this routine
239 -- with a unit that is not a spec, or which does not have a separate body.
241 function Corresponding_Spec (U : Unit_Id) return Unit_Id;
242 pragma Inline (Corresponding_Spec);
243 -- Given a unit which is a body for which there is a separate spec,
244 -- return the unit id of the spec. It is an error to call this routine
245 -- with a unit that is not a body, or which does not have a separate spec.
247 procedure Diagnose_Elaboration_Problem;
248 -- Called when no elaboration order can be found. Outputs an appropriate
249 -- diagnosis of the problem, and then abandons the bind.
251 procedure Elab_All_Links
252 (Before : Unit_Id;
253 After : Unit_Id;
254 Reason : Succ_Reason;
255 Link : Elab_All_Id);
256 -- Used to compute the transitive closure of elaboration links for an
257 -- Elaborate_All pragma (Reason = Elab_All) or for an indication of
258 -- Elaborate_All_Desirable (Reason = Elab_All_Desirable). Unit After has
259 -- a pragma Elaborate_All or the front end has determined that a reference
260 -- probably requires Elaborate_All is required, and unit Before must be
261 -- previously elaborated. First a link is built making sure that unit
262 -- Before is elaborated before After, then a recursive call ensures that
263 -- we also build links for any units needed by Before (i.e. these units
264 -- must/should also be elaborated before After). Link is used to build
265 -- a chain of Elab_All_Entries to explain the reason for a link. The
266 -- value passed is the chain so far.
268 procedure Elab_Error_Msg (S : Successor_Id);
269 -- Given a successor link, outputs an error message of the form
270 -- "$ must be elaborated before $ ..." where ... is the reason.
272 procedure Gather_Dependencies;
273 -- Compute dependencies, building the Succ and UNR tables
275 function Is_Body_Unit (U : Unit_Id) return Boolean;
276 pragma Inline (Is_Body_Unit);
277 -- Determines if given unit is a body
279 function Is_Waiting_Body (U : Unit_Id) return Boolean;
280 pragma Inline (Is_Waiting_Body);
281 -- Determines if U is a waiting body, defined as a body which has
282 -- not been elaborated, but whose spec has been elaborated.
284 function Make_Elab_Entry
285 (Unam : Unit_Name_Type;
286 Link : Elab_All_Id) return Elab_All_Id;
287 -- Make an Elab_All_Entries table entry with the given Unam and Link
289 function Unit_Id_Of (Uname : Unit_Name_Type) return Unit_Id;
290 -- This function uses the Info field set in the names table to obtain
291 -- the unit Id of a unit, given its name id value.
293 function Worse_Choice (U1, U2 : Unit_Id) return Boolean;
294 -- This is like Better_Choice, and has the same interface, but returns
295 -- true if U1 is a worse choice than U2 in the sense of the -h (horrible
296 -- elaboration order) switch. We still have to obey Ada rules, so it is
297 -- not quite the direct inverse of Better_Choice.
299 procedure Write_Dependencies;
300 -- Write out dependencies (called only if appropriate option is set)
302 procedure Write_Elab_All_Chain (S : Successor_Id);
303 -- If the reason for the link S is Elaborate_All or Elaborate_Desirable,
304 -- then this routine will output the "needed by" explanation chain.
306 -------------------
307 -- Better_Choice --
308 -------------------
310 function Better_Choice (U1, U2 : Unit_Id) return Boolean is
311 UT1 : Unit_Record renames Units.Table (U1);
312 UT2 : Unit_Record renames Units.Table (U2);
314 begin
315 if Debug_Flag_B then
316 Write_Str ("Better_Choice (");
317 Write_Unit_Name (UT1.Uname);
318 Write_Str (", ");
319 Write_Unit_Name (UT2.Uname);
320 Write_Line (")");
321 end if;
323 -- Note: the checks here are applied in sequence, and the ordering is
324 -- significant (i.e. the more important criteria are applied first).
326 -- Prefer a waiting body to any other case
328 if Is_Waiting_Body (U1) and then not Is_Waiting_Body (U2) then
329 if Debug_Flag_B then
330 Write_Line (" True: u1 is waiting body, u2 is not");
331 end if;
333 return True;
335 elsif Is_Waiting_Body (U2) and then not Is_Waiting_Body (U1) then
336 if Debug_Flag_B then
337 Write_Line (" False: u2 is waiting body, u1 is not");
338 end if;
340 return False;
342 -- Prefer a predefined unit to a non-predefined unit
344 elsif UT1.Predefined and then not UT2.Predefined then
345 if Debug_Flag_B then
346 Write_Line (" True: u1 is predefined, u2 is not");
347 end if;
349 return True;
351 elsif UT2.Predefined and then not UT1.Predefined then
352 if Debug_Flag_B then
353 Write_Line (" False: u2 is predefined, u1 is not");
354 end if;
356 return False;
358 -- Prefer an internal unit to a non-internal unit
360 elsif UT1.Internal and then not UT2.Internal then
361 if Debug_Flag_B then
362 Write_Line (" True: u1 is internal, u2 is not");
363 end if;
364 return True;
366 elsif UT2.Internal and then not UT1.Internal then
367 if Debug_Flag_B then
368 Write_Line (" False: u2 is internal, u1 is not");
369 end if;
371 return False;
373 -- Prefer a body to a spec
375 elsif Is_Body_Unit (U1) and then not Is_Body_Unit (U2) then
376 if Debug_Flag_B then
377 Write_Line (" True: u1 is body, u2 is not");
378 end if;
380 return True;
382 elsif Is_Body_Unit (U2) and then not Is_Body_Unit (U1) then
383 if Debug_Flag_B then
384 Write_Line (" False: u2 is body, u1 is not");
385 end if;
387 return False;
389 -- If both are waiting bodies, then prefer the one whose spec is
390 -- more recently elaborated. Consider the following:
392 -- spec of A
393 -- spec of B
394 -- body of A or B?
396 -- The normal waiting body preference would have placed the body of
397 -- A before the spec of B if it could. Since it could not, there it
398 -- must be the case that A depends on B. It is therefore a good idea
399 -- to put the body of B first.
401 elsif Is_Waiting_Body (U1) and then Is_Waiting_Body (U2) then
402 declare
403 Result : constant Boolean :=
404 UNR.Table (Corresponding_Spec (U1)).Elab_Position >
405 UNR.Table (Corresponding_Spec (U2)).Elab_Position;
406 begin
407 if Debug_Flag_B then
408 if Result then
409 Write_Line (" True: based on waiting body elab positions");
410 else
411 Write_Line (" False: based on waiting body elab positions");
412 end if;
413 end if;
415 return Result;
416 end;
417 end if;
419 -- Remaining choice rules are disabled by Debug flag -do
421 if not Debug_Flag_O then
423 -- The following deal with the case of specs which have been marked
424 -- as Elaborate_Body_Desirable. We generally want to delay these
425 -- specs as long as possible, so that the bodies have a better chance
426 -- of being elaborated closer to the specs.
428 -- If we have two units, one of which is a spec for which this flag
429 -- is set, and the other is not, we prefer to delay the spec for
430 -- which the flag is set.
432 if not UT1.Elaborate_Body_Desirable
433 and then UT2.Elaborate_Body_Desirable
434 then
435 if Debug_Flag_B then
436 Write_Line (" True: u1 is elab body desirable, u2 is not");
437 end if;
439 return True;
441 elsif not UT2.Elaborate_Body_Desirable
442 and then UT1.Elaborate_Body_Desirable
443 then
444 if Debug_Flag_B then
445 Write_Line (" False: u1 is elab body desirable, u2 is not");
446 end if;
448 return False;
450 -- If we have two specs that are both marked as Elaborate_Body
451 -- desirable, we prefer the one whose body is nearer to being able
452 -- to be elaborated, based on the Num_Pred count. This helps to
453 -- ensure bodies are as close to specs as possible.
455 elsif UT1.Elaborate_Body_Desirable
456 and then UT2.Elaborate_Body_Desirable
457 then
458 declare
459 Result : constant Boolean :=
460 UNR.Table (Corresponding_Body (U1)).Num_Pred <
461 UNR.Table (Corresponding_Body (U2)).Num_Pred;
462 begin
463 if Debug_Flag_B then
464 if Result then
465 Write_Line (" True based on Num_Pred compare");
466 else
467 Write_Line (" False based on Num_Pred compare");
468 end if;
469 end if;
471 return Result;
472 end;
473 end if;
474 end if;
476 -- If we fall through, it means that no preference rule applies, so we
477 -- use alphabetical order to at least give a deterministic result.
479 if Debug_Flag_B then
480 Write_Line (" choose on alpha order");
481 end if;
483 return Uname_Less (UT1.Uname, UT2.Uname);
484 end Better_Choice;
486 ----------------
487 -- Build_Link --
488 ----------------
490 procedure Build_Link
491 (Before : Unit_Id;
492 After : Unit_Id;
493 R : Succ_Reason;
494 Ea_Id : Elab_All_Id := No_Elab_All_Link)
496 Cspec : Unit_Id;
498 begin
499 Succ.Increment_Last;
500 Succ.Table (Succ.Last).Before := Before;
501 Succ.Table (Succ.Last).Next := UNR.Table (Before).Successors;
502 UNR.Table (Before).Successors := Succ.Last;
503 Succ.Table (Succ.Last).Reason := R;
504 Succ.Table (Succ.Last).Reason_Unit := Cur_Unit;
505 Succ.Table (Succ.Last).Elab_All_Link := Ea_Id;
507 -- Deal with special Elab_Body case. If the After of this link is
508 -- a body whose spec has Elaborate_All set, and this is not the link
509 -- directly from the body to the spec, then we make the After of the
510 -- link reference its spec instead, marking the link appropriately.
512 if Units.Table (After).Utype = Is_Body then
513 Cspec := Corresponding_Spec (After);
515 if Units.Table (Cspec).Elaborate_Body
516 and then Cspec /= Before
517 then
518 Succ.Table (Succ.Last).After := Cspec;
519 Succ.Table (Succ.Last).Elab_Body := True;
520 UNR.Table (Cspec).Num_Pred := UNR.Table (Cspec).Num_Pred + 1;
521 return;
522 end if;
523 end if;
525 -- Fall through on normal case
527 Succ.Table (Succ.Last).After := After;
528 Succ.Table (Succ.Last).Elab_Body := False;
529 UNR.Table (After).Num_Pred := UNR.Table (After).Num_Pred + 1;
530 end Build_Link;
532 ------------
533 -- Choose --
534 ------------
536 procedure Choose (Chosen : Unit_Id) is
537 S : Successor_Id;
538 U : Unit_Id;
540 begin
541 if Debug_Flag_C then
542 Write_Str ("Choosing Unit ");
543 Write_Unit_Name (Units.Table (Chosen).Uname);
544 Write_Eol;
545 end if;
547 -- Add to elaboration order. Note that units having no elaboration
548 -- code are not treated specially yet. The special casing of this
549 -- is in Bindgen, where Gen_Elab_Calls skips over them. Meanwhile
550 -- we need them here, because the object file list is also driven
551 -- by the contents of the Elab_Order table.
553 Elab_Order.Increment_Last;
554 Elab_Order.Table (Elab_Order.Last) := Chosen;
556 -- Remove from No_Pred list. This is a little inefficient and may
557 -- be we should doubly link the list, but it will do for now!
559 if No_Pred = Chosen then
560 No_Pred := UNR.Table (Chosen).Nextnp;
562 else
563 -- Note that we just ignore the situation where it does not
564 -- appear in the No_Pred list, this happens in calls from the
565 -- Diagnose_Elaboration_Problem routine, where cycles are being
566 -- removed arbitrarily from the graph.
568 U := No_Pred;
569 while U /= No_Unit_Id loop
570 if UNR.Table (U).Nextnp = Chosen then
571 UNR.Table (U).Nextnp := UNR.Table (Chosen).Nextnp;
572 exit;
573 end if;
575 U := UNR.Table (U).Nextnp;
576 end loop;
577 end if;
579 -- For all successors, decrement the number of predecessors, and
580 -- if it becomes zero, then add to no predecessor list.
582 S := UNR.Table (Chosen).Successors;
583 while S /= No_Successor loop
584 U := Succ.Table (S).After;
585 UNR.Table (U).Num_Pred := UNR.Table (U).Num_Pred - 1;
587 if Debug_Flag_N then
588 Write_Str (" decrementing Num_Pred for unit ");
589 Write_Unit_Name (Units.Table (U).Uname);
590 Write_Str (" new value = ");
591 Write_Int (Int (UNR.Table (U).Num_Pred));
592 Write_Eol;
593 end if;
595 if UNR.Table (U).Num_Pred = 0 then
596 UNR.Table (U).Nextnp := No_Pred;
597 No_Pred := U;
598 end if;
600 S := Succ.Table (S).Next;
601 end loop;
603 -- All done, adjust number of units left count and set elaboration pos
605 Num_Left := Num_Left - 1;
606 Num_Chosen := Num_Chosen + 1;
607 UNR.Table (Chosen).Elab_Position := Num_Chosen;
608 Units.Table (Chosen).Elab_Position := Num_Chosen;
610 -- If we just chose a spec with Elaborate_Body set, then we
611 -- must immediately elaborate the body, before any other units.
613 if Units.Table (Chosen).Elaborate_Body then
615 -- If the unit is a spec only, then there is no body. This is a bit
616 -- odd given that Elaborate_Body is here, but it is valid in an
617 -- RCI unit, where we only have the interface in the stub bind.
619 if Units.Table (Chosen).Utype = Is_Spec_Only
620 and then Units.Table (Chosen).RCI
621 then
622 null;
623 else
624 Choose (Corresponding_Body (Chosen));
625 end if;
626 end if;
627 end Choose;
629 ------------------------
630 -- Corresponding_Body --
631 ------------------------
633 -- Currently if the body and spec are separate, then they appear as
634 -- two separate units in the same ALI file, with the body appearing
635 -- first and the spec appearing second.
637 function Corresponding_Body (U : Unit_Id) return Unit_Id is
638 begin
639 pragma Assert (Units.Table (U).Utype = Is_Spec);
640 return U - 1;
641 end Corresponding_Body;
643 ------------------------
644 -- Corresponding_Spec --
645 ------------------------
647 -- Currently if the body and spec are separate, then they appear as
648 -- two separate units in the same ALI file, with the body appearing
649 -- first and the spec appearing second.
651 function Corresponding_Spec (U : Unit_Id) return Unit_Id is
652 begin
653 pragma Assert (Units.Table (U).Utype = Is_Body);
654 return U + 1;
655 end Corresponding_Spec;
657 ----------------------------------
658 -- Diagnose_Elaboration_Problem --
659 ----------------------------------
661 procedure Diagnose_Elaboration_Problem is
663 function Find_Path (Ufrom, Uto : Unit_Id; ML : Nat) return Boolean;
664 -- Recursive routine used to find a path from node Ufrom to node Uto.
665 -- If a path exists, returns True and outputs an appropriate set of
666 -- error messages giving the path. Also calls Choose for each of the
667 -- nodes so that they get removed from the remaining set. There are
668 -- two cases of calls, either Ufrom = Uto for an attempt to find a
669 -- cycle, or Ufrom is a spec and Uto the corresponding body for the
670 -- case of an unsatisfiable Elaborate_Body pragma. ML is the minimum
671 -- acceptable length for a path.
673 ---------------
674 -- Find_Path --
675 ---------------
677 function Find_Path (Ufrom, Uto : Unit_Id; ML : Nat) return Boolean is
679 function Find_Link (U : Unit_Id; PL : Nat) return Boolean;
680 -- This is the inner recursive routine, it determines if a path
681 -- exists from U to Uto, and if so returns True and outputs the
682 -- appropriate set of error messages. PL is the path length
684 ---------------
685 -- Find_Link --
686 ---------------
688 function Find_Link (U : Unit_Id; PL : Nat) return Boolean is
689 S : Successor_Id;
691 begin
692 -- Recursion ends if we are at terminating node and the path
693 -- is sufficiently long, generate error message and return True.
695 if U = Uto and then PL >= ML then
696 Choose (U);
697 return True;
699 -- All done if already visited, otherwise mark as visited
701 elsif UNR.Table (U).Visited then
702 return False;
704 -- Otherwise mark as visited and look at all successors
706 else
707 UNR.Table (U).Visited := True;
709 S := UNR.Table (U).Successors;
710 while S /= No_Successor loop
711 if Find_Link (Succ.Table (S).After, PL + 1) then
712 Elab_Error_Msg (S);
713 Choose (U);
714 return True;
715 end if;
717 S := Succ.Table (S).Next;
718 end loop;
720 -- Falling through means this does not lead to a path
722 return False;
723 end if;
724 end Find_Link;
726 -- Start of processing for Find_Path
728 begin
729 -- Initialize all non-chosen nodes to not visisted yet
731 for U in Units.First .. Units.Last loop
732 UNR.Table (U).Visited := UNR.Table (U).Elab_Position /= 0;
733 end loop;
735 -- Now try to find the path
737 return Find_Link (Ufrom, 0);
738 end Find_Path;
740 -- Start of processing for Diagnose_Elaboration_Error
742 begin
743 Set_Standard_Error;
745 -- Output state of things if debug flag N set
747 if Debug_Flag_N then
748 declare
749 NP : Int;
751 begin
752 Write_Eol;
753 Write_Eol;
754 Write_Str ("Diagnose_Elaboration_Problem called");
755 Write_Eol;
756 Write_Str ("List of remaining unchosen units and predecessors");
757 Write_Eol;
759 for U in Units.First .. Units.Last loop
760 if UNR.Table (U).Elab_Position = 0 then
761 NP := UNR.Table (U).Num_Pred;
762 Write_Eol;
763 Write_Str (" Unchosen unit: #");
764 Write_Int (Int (U));
765 Write_Str (" ");
766 Write_Unit_Name (Units.Table (U).Uname);
767 Write_Str (" (Num_Pred = ");
768 Write_Int (NP);
769 Write_Char (')');
770 Write_Eol;
772 if NP = 0 then
773 if Units.Table (U).Elaborate_Body then
774 Write_Str
775 (" (not chosen because of Elaborate_Body)");
776 Write_Eol;
777 else
778 Write_Str (" ****************** why not chosen?");
779 Write_Eol;
780 end if;
781 end if;
783 -- Search links list to find unchosen predecessors
785 for S in Succ.First .. Succ.Last loop
786 declare
787 SL : Successor_Link renames Succ.Table (S);
789 begin
790 if SL.After = U
791 and then UNR.Table (SL.Before).Elab_Position = 0
792 then
793 Write_Str (" unchosen predecessor: #");
794 Write_Int (Int (SL.Before));
795 Write_Str (" ");
796 Write_Unit_Name (Units.Table (SL.Before).Uname);
797 Write_Eol;
798 NP := NP - 1;
799 end if;
800 end;
801 end loop;
803 if NP /= 0 then
804 Write_Str (" **************** Num_Pred value wrong!");
805 Write_Eol;
806 end if;
807 end if;
808 end loop;
809 end;
810 end if;
812 -- Output the header for the error, and manually increment the
813 -- error count. We are using Error_Msg_Output rather than Error_Msg
814 -- here for two reasons:
816 -- This is really only one error, not one for each line
817 -- We want this output on standard output since it is voluminous
819 -- But we do need to deal with the error count manually in this case
821 Errors_Detected := Errors_Detected + 1;
822 Error_Msg_Output ("elaboration circularity detected", Info => False);
824 -- Try to find cycles starting with any of the remaining nodes that have
825 -- not yet been chosen. There must be at least one (there is some reason
826 -- we are being called!)
828 for U in Units.First .. Units.Last loop
829 if UNR.Table (U).Elab_Position = 0 then
830 if Find_Path (U, U, 1) then
831 raise Unrecoverable_Error;
832 end if;
833 end if;
834 end loop;
836 -- We should never get here, since we were called for some reason,
837 -- and we should have found and eliminated at least one bad path.
839 raise Program_Error;
840 end Diagnose_Elaboration_Problem;
842 --------------------
843 -- Elab_All_Links --
844 --------------------
846 procedure Elab_All_Links
847 (Before : Unit_Id;
848 After : Unit_Id;
849 Reason : Succ_Reason;
850 Link : Elab_All_Id)
852 begin
853 if UNR.Table (Before).Visited then
854 return;
855 end if;
857 -- Build the direct link for Before
859 UNR.Table (Before).Visited := True;
860 Build_Link (Before, After, Reason, Link);
862 -- Process all units with'ed by Before recursively
864 for W in
865 Units.Table (Before).First_With .. Units.Table (Before).Last_With
866 loop
867 -- Skip if this with is an interface to a stand-alone library.
868 -- Skip also if no ALI file for this WITH, happens for language
869 -- defined generics while bootstrapping the compiler (see body of
870 -- Lib.Writ.Write_With_Lines). Finally, skip if it is a limited
871 -- with clause, which does not impose an elaboration link.
873 if not Withs.Table (W).SAL_Interface
874 and then Withs.Table (W).Afile /= No_File
875 and then not Withs.Table (W).Limited_With
876 then
877 declare
878 Info : constant Int :=
879 Get_Name_Table_Info
880 (Withs.Table (W).Uname);
882 begin
883 -- If the unit is unknown, for some unknown reason, fail
884 -- graciously explaining that the unit is unknown. Without
885 -- this check, gnatbind will crash in Unit_Id_Of.
887 if Info = 0 or else Unit_Id (Info) = No_Unit_Id then
888 declare
889 Withed : String :=
890 Get_Name_String (Withs.Table (W).Uname);
891 Last_Withed : Natural := Withed'Last;
892 Withing : String :=
893 Get_Name_String
894 (Units.Table (Before).Uname);
895 Last_Withing : Natural := Withing'Last;
896 Spec_Body : String := " (Spec)";
898 begin
899 To_Mixed (Withed);
900 To_Mixed (Withing);
902 if Last_Withed > 2 and then
903 Withed (Last_Withed - 1) = '%'
904 then
905 Last_Withed := Last_Withed - 2;
906 end if;
908 if Last_Withing > 2 and then
909 Withing (Last_Withing - 1) = '%'
910 then
911 Last_Withing := Last_Withing - 2;
912 end if;
914 if Units.Table (Before).Utype = Is_Body or else
915 Units.Table (Before).Utype = Is_Body_Only
916 then
917 Spec_Body := " (Body)";
918 end if;
920 Osint.Fail
921 ("could not find unit "
922 & Withed (Withed'First .. Last_Withed) & " needed by "
923 & Withing (Withing'First .. Last_Withing) & Spec_Body);
924 end;
925 end if;
927 Elab_All_Links
928 (Unit_Id_Of (Withs.Table (W).Uname),
929 After,
930 Reason,
931 Make_Elab_Entry (Withs.Table (W).Uname, Link));
932 end;
933 end if;
934 end loop;
936 -- Process corresponding body, if there is one
938 if Units.Table (Before).Utype = Is_Spec then
939 Elab_All_Links
940 (Corresponding_Body (Before),
941 After, Reason,
942 Make_Elab_Entry
943 (Units.Table (Corresponding_Body (Before)).Uname, Link));
944 end if;
945 end Elab_All_Links;
947 --------------------
948 -- Elab_Error_Msg --
949 --------------------
951 procedure Elab_Error_Msg (S : Successor_Id) is
952 SL : Successor_Link renames Succ.Table (S);
954 begin
955 -- Nothing to do if internal unit involved and no -da flag
957 if not Debug_Flag_A
958 and then
959 (Is_Internal_File_Name (Units.Table (SL.Before).Sfile)
960 or else
961 Is_Internal_File_Name (Units.Table (SL.After).Sfile))
962 then
963 return;
964 end if;
966 -- Here we want to generate output
968 Error_Msg_Unit_1 := Units.Table (SL.Before).Uname;
970 if SL.Elab_Body then
971 Error_Msg_Unit_2 := Units.Table (Corresponding_Body (SL.After)).Uname;
972 else
973 Error_Msg_Unit_2 := Units.Table (SL.After).Uname;
974 end if;
976 Error_Msg_Output (" $ must be elaborated before $", Info => True);
978 Error_Msg_Unit_1 := Units.Table (SL.Reason_Unit).Uname;
980 case SL.Reason is
981 when Withed =>
982 Error_Msg_Output
983 (" reason: with clause",
984 Info => True);
986 when Elab =>
987 Error_Msg_Output
988 (" reason: pragma Elaborate in unit $",
989 Info => True);
991 when Elab_All =>
992 Error_Msg_Output
993 (" reason: pragma Elaborate_All in unit $",
994 Info => True);
996 when Elab_All_Desirable =>
997 Error_Msg_Output
998 (" reason: implicit Elaborate_All in unit $",
999 Info => True);
1001 Error_Msg_Output
1002 (" recompile $ with -gnatwl for full details",
1003 Info => True);
1005 when Elab_Desirable =>
1006 Error_Msg_Output
1007 (" reason: implicit Elaborate in unit $",
1008 Info => True);
1010 Error_Msg_Output
1011 (" recompile $ with -gnatwl for full details",
1012 Info => True);
1014 when Spec_First =>
1015 Error_Msg_Output
1016 (" reason: spec always elaborated before body",
1017 Info => True);
1018 end case;
1020 Write_Elab_All_Chain (S);
1022 if SL.Elab_Body then
1023 Error_Msg_Unit_1 := Units.Table (SL.Before).Uname;
1024 Error_Msg_Unit_2 := Units.Table (SL.After).Uname;
1025 Error_Msg_Output
1026 (" $ must therefore be elaborated before $",
1027 True);
1029 Error_Msg_Unit_1 := Units.Table (SL.After).Uname;
1030 Error_Msg_Output
1031 (" (because $ has a pragma Elaborate_Body)",
1032 True);
1033 end if;
1035 if not Zero_Formatting then
1036 Write_Eol;
1037 end if;
1038 end Elab_Error_Msg;
1040 ---------------------
1041 -- Find_Elab_Order --
1042 ---------------------
1044 procedure Find_Elab_Order is
1045 U : Unit_Id;
1046 Best_So_Far : Unit_Id;
1048 begin
1049 Succ.Init;
1050 Num_Left := Int (Units.Last - Units.First + 1);
1052 -- Initialize unit table for elaboration control
1054 for U in Units.First .. Units.Last loop
1055 UNR.Increment_Last;
1056 UNR.Table (UNR.Last).Successors := No_Successor;
1057 UNR.Table (UNR.Last).Num_Pred := 0;
1058 UNR.Table (UNR.Last).Nextnp := No_Unit_Id;
1059 UNR.Table (UNR.Last).Elab_Order := 0;
1060 UNR.Table (UNR.Last).Elab_Position := 0;
1061 end loop;
1063 -- Output warning if -p used with no -gnatE units
1065 if Pessimistic_Elab_Order
1066 and not Dynamic_Elaboration_Checks_Specified
1067 then
1068 if OpenVMS_On_Target then
1069 Error_Msg ("?use of /PESSIMISTIC_ELABORATION questionable");
1070 else
1071 Error_Msg ("?use of -p switch questionable");
1072 end if;
1074 Error_Msg ("?since all units compiled with static elaboration model");
1075 end if;
1077 -- Gather dependencies and output them if option set
1079 Gather_Dependencies;
1081 -- Output elaboration dependencies if option is set
1083 if Elab_Dependency_Output or Debug_Flag_E then
1084 Write_Dependencies;
1085 end if;
1087 -- Initialize the no predecessor list
1089 No_Pred := No_Unit_Id;
1091 for U in UNR.First .. UNR.Last loop
1092 if UNR.Table (U).Num_Pred = 0 then
1093 UNR.Table (U).Nextnp := No_Pred;
1094 No_Pred := U;
1095 end if;
1096 end loop;
1098 -- OK, now we determine the elaboration order proper. All we do is to
1099 -- select the best choice from the no predecessor list until all the
1100 -- nodes have been chosen.
1102 Outer : loop
1104 -- If there are no nodes with predecessors, then either we are
1105 -- done, as indicated by Num_Left being set to zero, or we have
1106 -- a circularity. In the latter case, diagnose the circularity,
1107 -- removing it from the graph and continue
1109 Get_No_Pred : while No_Pred = No_Unit_Id loop
1110 exit Outer when Num_Left < 1;
1111 Diagnose_Elaboration_Problem;
1112 end loop Get_No_Pred;
1114 U := No_Pred;
1115 Best_So_Far := No_Unit_Id;
1117 -- Loop to choose best entry in No_Pred list
1119 No_Pred_Search : loop
1120 if Debug_Flag_N then
1121 Write_Str (" considering choice of ");
1122 Write_Unit_Name (Units.Table (U).Uname);
1123 Write_Eol;
1125 if Units.Table (U).Elaborate_Body then
1126 Write_Str
1127 (" Elaborate_Body = True, Num_Pred for body = ");
1128 Write_Int
1129 (Int (UNR.Table (Corresponding_Body (U)).Num_Pred));
1130 else
1131 Write_Str
1132 (" Elaborate_Body = False");
1133 end if;
1135 Write_Eol;
1136 end if;
1138 -- This is a candididate to be considered for choice
1140 if Best_So_Far = No_Unit_Id
1141 or else ((not Pessimistic_Elab_Order)
1142 and then Better_Choice (U, Best_So_Far))
1143 or else (Pessimistic_Elab_Order
1144 and then Worse_Choice (U, Best_So_Far))
1145 then
1146 if Debug_Flag_N then
1147 Write_Str (" tentatively chosen (best so far)");
1148 Write_Eol;
1149 end if;
1151 Best_So_Far := U;
1152 end if;
1154 U := UNR.Table (U).Nextnp;
1155 exit No_Pred_Search when U = No_Unit_Id;
1156 end loop No_Pred_Search;
1158 -- If no candididate chosen, it means that no unit has No_Pred = 0,
1159 -- but there are units left, hence we have a circular dependency,
1160 -- which we will get Diagnose_Elaboration_Problem to diagnose it.
1162 if Best_So_Far = No_Unit_Id then
1163 Diagnose_Elaboration_Problem;
1165 -- Otherwise choose the best candidate found
1167 else
1168 Choose (Best_So_Far);
1169 end if;
1170 end loop Outer;
1171 end Find_Elab_Order;
1173 -------------------------
1174 -- Gather_Dependencies --
1175 -------------------------
1177 procedure Gather_Dependencies is
1178 Withed_Unit : Unit_Id;
1180 begin
1181 -- Loop through all units
1183 for U in Units.First .. Units.Last loop
1184 Cur_Unit := U;
1186 -- If this is not an interface to a stand-alone library and
1187 -- there is a body and a spec, then spec must be elaborated first
1188 -- Note that the corresponding spec immediately follows the body
1190 if not Units.Table (U).SAL_Interface
1191 and then Units.Table (U).Utype = Is_Body
1192 then
1193 Build_Link (Corresponding_Spec (U), U, Spec_First);
1194 end if;
1196 -- If this unit is not an interface to a stand-alone library,
1197 -- process WITH references for this unit ignoring generic units and
1198 -- interfaces to stand-alone libraries.
1200 if not Units.Table (U).SAL_Interface then
1202 W in Units.Table (U).First_With .. Units.Table (U).Last_With
1203 loop
1204 if Withs.Table (W).Sfile /= No_File
1205 and then (not Withs.Table (W).SAL_Interface)
1206 then
1207 -- Check for special case of withing a unit that does not
1208 -- exist any more. If the unit was completely missing we
1209 -- would already have detected this, but a nasty case arises
1210 -- when we have a subprogram body with no spec, and some
1211 -- obsolete unit with's a previous (now disappeared) spec.
1213 if Get_Name_Table_Info (Withs.Table (W).Uname) = 0 then
1214 Error_Msg_File_1 := Units.Table (U).Sfile;
1215 Error_Msg_Unit_1 := Withs.Table (W).Uname;
1216 Error_Msg ("{ depends on $ which no longer exists");
1217 goto Next_With;
1218 end if;
1220 Withed_Unit :=
1221 Unit_Id (Unit_Id_Of (Withs.Table (W).Uname));
1223 -- Pragma Elaborate_All case, for this we use the recursive
1224 -- Elab_All_Links procedure to establish the links.
1226 if Withs.Table (W).Elaborate_All then
1228 -- Reset flags used to stop multiple visits to a given
1229 -- node.
1231 for Uref in UNR.First .. UNR.Last loop
1232 UNR.Table (Uref).Visited := False;
1233 end loop;
1235 -- Now establish all the links we need
1237 Elab_All_Links
1238 (Withed_Unit, U, Elab_All,
1239 Make_Elab_Entry
1240 (Withs.Table (W).Uname, No_Elab_All_Link));
1242 -- Elaborate_All_Desirable case, for this we establish the
1243 -- same links as above, but with a different reason.
1245 elsif Withs.Table (W).Elab_All_Desirable then
1247 -- Reset flags used to stop multiple visits to a given
1248 -- node.
1250 for Uref in UNR.First .. UNR.Last loop
1251 UNR.Table (Uref).Visited := False;
1252 end loop;
1254 -- Now establish all the links we need
1256 Elab_All_Links
1257 (Withed_Unit, U, Elab_All_Desirable,
1258 Make_Elab_Entry
1259 (Withs.Table (W).Uname, No_Elab_All_Link));
1261 -- Pragma Elaborate case. We must build a link for the
1262 -- withed unit itself, and also the corresponding body if
1263 -- there is one.
1265 -- However, skip this processing if there is no ALI file for
1266 -- the WITH entry, because this means it is a generic (even
1267 -- when we fix the generics so that an ALI file is present,
1268 -- we probably still will have no ALI file for unchecked and
1269 -- other special cases).
1271 elsif Withs.Table (W).Elaborate
1272 and then Withs.Table (W).Afile /= No_File
1273 then
1274 Build_Link (Withed_Unit, U, Withed);
1276 if Units.Table (Withed_Unit).Utype = Is_Spec then
1277 Build_Link
1278 (Corresponding_Body (Withed_Unit), U, Elab);
1279 end if;
1281 -- Elaborate_Desirable case, for this we establish
1282 -- the same links as above, but with a different reason.
1284 elsif Withs.Table (W).Elab_Desirable then
1285 Build_Link (Withed_Unit, U, Withed);
1287 if Units.Table (Withed_Unit).Utype = Is_Spec then
1288 Build_Link
1289 (Corresponding_Body (Withed_Unit),
1290 U, Elab_Desirable);
1291 end if;
1293 -- A limited_with does not establish an elaboration
1294 -- dependence (that's the whole point!).
1296 elsif Withs.Table (W).Limited_With then
1297 null;
1299 -- Case of normal WITH with no elaboration pragmas, just
1300 -- build the single link to the directly referenced unit
1302 else
1303 Build_Link (Withed_Unit, U, Withed);
1304 end if;
1305 end if;
1307 <<Next_With>>
1308 null;
1309 end loop;
1310 end if;
1311 end loop;
1312 end Gather_Dependencies;
1314 ------------------
1315 -- Is_Body_Unit --
1316 ------------------
1318 function Is_Body_Unit (U : Unit_Id) return Boolean is
1319 begin
1320 return Units.Table (U).Utype = Is_Body
1321 or else Units.Table (U).Utype = Is_Body_Only;
1322 end Is_Body_Unit;
1324 ---------------------
1325 -- Is_Waiting_Body --
1326 ---------------------
1328 function Is_Waiting_Body (U : Unit_Id) return Boolean is
1329 begin
1330 return Units.Table (U).Utype = Is_Body
1331 and then UNR.Table (Corresponding_Spec (U)).Elab_Position /= 0;
1332 end Is_Waiting_Body;
1334 ---------------------
1335 -- Make_Elab_Entry --
1336 ---------------------
1338 function Make_Elab_Entry
1339 (Unam : Unit_Name_Type;
1340 Link : Elab_All_Id) return Elab_All_Id
1342 begin
1343 Elab_All_Entries.Increment_Last;
1344 Elab_All_Entries.Table (Elab_All_Entries.Last).Needed_By := Unam;
1345 Elab_All_Entries.Table (Elab_All_Entries.Last).Next_Elab := Link;
1346 return Elab_All_Entries.Last;
1347 end Make_Elab_Entry;
1349 ----------------
1350 -- Unit_Id_Of --
1351 ----------------
1353 function Unit_Id_Of (Uname : Unit_Name_Type) return Unit_Id is
1354 Info : constant Int := Get_Name_Table_Info (Uname);
1355 begin
1356 pragma Assert (Info /= 0 and then Unit_Id (Info) /= No_Unit_Id);
1357 return Unit_Id (Info);
1358 end Unit_Id_Of;
1360 ------------------
1361 -- Worse_Choice --
1362 ------------------
1364 function Worse_Choice (U1, U2 : Unit_Id) return Boolean is
1365 UT1 : Unit_Record renames Units.Table (U1);
1366 UT2 : Unit_Record renames Units.Table (U2);
1368 begin
1369 -- Note: the checks here are applied in sequence, and the ordering is
1370 -- significant (i.e. the more important criteria are applied first).
1372 -- If either unit is internal, then use Better_Choice, since the
1373 -- language requires that predefined units not mess up in the choice
1374 -- of elaboration order, and for internal units, any problems are
1375 -- ours and not the programmers.
1377 if UT1.Internal or else UT2.Internal then
1378 return Better_Choice (U1, U2);
1380 -- Prefer anything else to a waiting body (!)
1382 elsif Is_Waiting_Body (U1) and then not Is_Waiting_Body (U2) then
1383 return False;
1385 elsif Is_Waiting_Body (U2) and then not Is_Waiting_Body (U1) then
1386 return True;
1388 -- Prefer a spec to a body (!)
1390 elsif Is_Body_Unit (U1) and then not Is_Body_Unit (U2) then
1391 return False;
1393 elsif Is_Body_Unit (U2) and then not Is_Body_Unit (U1) then
1394 return True;
1396 -- If both are waiting bodies, then prefer the one whose spec is
1397 -- less recently elaborated. Consider the following:
1399 -- spec of A
1400 -- spec of B
1401 -- body of A or B?
1403 -- The normal waiting body preference would have placed the body of
1404 -- A before the spec of B if it could. Since it could not, there it
1405 -- must be the case that A depends on B. It is therefore a good idea
1406 -- to put the body of B last so that if there is an elaboration order
1407 -- problem, we will find it (that's what horrible order is about)
1409 elsif Is_Waiting_Body (U1) and then Is_Waiting_Body (U2) then
1410 return
1411 UNR.Table (Corresponding_Spec (U1)).Elab_Position <
1412 UNR.Table (Corresponding_Spec (U2)).Elab_Position;
1413 end if;
1415 -- Remaining choice rules are disabled by Debug flag -do
1417 if not Debug_Flag_O then
1419 -- The following deal with the case of specs which have been marked
1420 -- as Elaborate_Body_Desirable. In the normal case, we generally want
1421 -- to delay the elaboration of these specs as long as possible, so
1422 -- that bodies have better chance of being elaborated closer to the
1423 -- specs. Worse_Choice as usual wants to do the opposite and
1424 -- elaborate such specs as early as possible.
1426 -- If we have two units, one of which is a spec for which this flag
1427 -- is set, and the other is not, we normally prefer to delay the spec
1428 -- for which the flag is set, and so Worse_Choice does the opposite.
1430 if not UT1.Elaborate_Body_Desirable
1431 and then UT2.Elaborate_Body_Desirable
1432 then
1433 return False;
1435 elsif not UT2.Elaborate_Body_Desirable
1436 and then UT1.Elaborate_Body_Desirable
1437 then
1438 return True;
1440 -- If we have two specs that are both marked as Elaborate_Body
1441 -- desirable, we normally prefer the one whose body is nearer to
1442 -- being able to be elaborated, based on the Num_Pred count. This
1443 -- helps to ensure bodies are as close to specs as possible. As
1444 -- usual, Worse_Choice does the opposite.
1446 elsif UT1.Elaborate_Body_Desirable
1447 and then UT2.Elaborate_Body_Desirable
1448 then
1449 return UNR.Table (Corresponding_Body (U1)).Num_Pred >=
1450 UNR.Table (Corresponding_Body (U2)).Num_Pred;
1451 end if;
1452 end if;
1454 -- If we fall through, it means that no preference rule applies, so we
1455 -- use alphabetical order to at least give a deterministic result. Since
1456 -- Worse_Choice is in the business of stirring up the order, we will
1457 -- use reverse alphabetical ordering.
1459 return Uname_Less (UT2.Uname, UT1.Uname);
1460 end Worse_Choice;
1462 ------------------------
1463 -- Write_Dependencies --
1464 ------------------------
1466 procedure Write_Dependencies is
1467 begin
1468 if not Zero_Formatting then
1469 Write_Eol;
1470 Write_Str (" ELABORATION ORDER DEPENDENCIES");
1471 Write_Eol;
1472 Write_Eol;
1473 end if;
1475 Info_Prefix_Suppress := True;
1477 for S in Succ_First .. Succ.Last loop
1478 Elab_Error_Msg (S);
1479 end loop;
1481 Info_Prefix_Suppress := False;
1483 if not Zero_Formatting then
1484 Write_Eol;
1485 end if;
1486 end Write_Dependencies;
1488 --------------------------
1489 -- Write_Elab_All_Chain --
1490 --------------------------
1492 procedure Write_Elab_All_Chain (S : Successor_Id) is
1493 ST : constant Successor_Link := Succ.Table (S);
1494 After : constant Unit_Name_Type := Units.Table (ST.After).Uname;
1496 L : Elab_All_Id;
1497 Nam : Unit_Name_Type;
1499 First_Name : Boolean := True;
1501 begin
1502 if ST.Reason in Elab_All .. Elab_All_Desirable then
1503 L := ST.Elab_All_Link;
1504 while L /= No_Elab_All_Link loop
1505 Nam := Elab_All_Entries.Table (L).Needed_By;
1506 Error_Msg_Unit_1 := Nam;
1507 Error_Msg_Output (" $", Info => True);
1509 Get_Name_String (Nam);
1511 if Name_Buffer (Name_Len) = 'b' then
1512 if First_Name then
1513 Error_Msg_Output
1514 (" must be elaborated along with its spec:",
1515 Info => True);
1517 else
1518 Error_Msg_Output
1519 (" which must be elaborated " &
1520 "along with its spec:",
1521 Info => True);
1522 end if;
1524 else
1525 if First_Name then
1526 Error_Msg_Output
1527 (" is withed by:",
1528 Info => True);
1530 else
1531 Error_Msg_Output
1532 (" which is withed by:",
1533 Info => True);
1534 end if;
1535 end if;
1537 First_Name := False;
1539 L := Elab_All_Entries.Table (L).Next_Elab;
1540 end loop;
1542 Error_Msg_Unit_1 := After;
1543 Error_Msg_Output (" $", Info => True);
1544 end if;
1545 end Write_Elab_All_Chain;
1547 end Binde;