1 ------------------------------------------------------------------------------
3 -- GNAT COMPILER COMPONENTS --
9 -- Copyright (C) 1996-2016, Free Software Foundation, Inc. --
11 -- GNAT is free software; you can redistribute it and/or modify it under --
12 -- terms of the GNU General Public License as published by the Free Soft- --
13 -- ware Foundation; either version 3, or (at your option) any later ver- --
14 -- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License --
17 -- for more details. You should have received a copy of the GNU General --
18 -- Public License distributed with GNAT; see file COPYING3. If not, go to --
19 -- http://www.gnu.org/licenses for a complete copy of the license. --
21 -- GNAT was originally developed by the GNAT team at New York University. --
22 -- Extensive contributions were provided by Ada Core Technologies Inc. --
24 ------------------------------------------------------------------------------
26 -- Gnatlink usage: please consult the gnat documentation
30 with Gnatvsn
; use Gnatvsn
;
31 with Indepsw
; use Indepsw
;
32 with Namet
; use Namet
;
34 with Osint
; use Osint
;
35 with Output
; use Output
;
37 with Switch
; use Switch
;
38 with System
; use System
;
40 with Targparm
; use Targparm
;
43 with Ada
.Command_Line
; use Ada
.Command_Line
;
44 with Ada
.Exceptions
; use Ada
.Exceptions
;
46 with System
.OS_Lib
; use System
.OS_Lib
;
49 with Interfaces
.C_Streams
; use Interfaces
.C_Streams
;
50 with Interfaces
.C
.Strings
; use Interfaces
.C
.Strings
;
53 pragma Ident
(Gnatvsn
.Gnat_Static_Version_String
);
55 Shared_Libgcc_String
: constant String := "-shared-libgcc";
56 Shared_Libgcc
: constant String_Access
:=
57 new String'(Shared_Libgcc_String);
58 -- Used to invoke gcc when the binder is invoked with -shared
60 Static_Libgcc_String : constant String := "-static-libgcc";
61 Static_Libgcc : constant String_Access :=
62 new String'(Static_Libgcc_String
);
63 -- Used to invoke gcc when shared libs are not used
65 package Gcc_Linker_Options
is new Table
.Table
(
66 Table_Component_Type
=> String_Access
,
67 Table_Index_Type
=> Integer,
70 Table_Increment
=> 100,
71 Table_Name
=> "Gnatlink.Gcc_Linker_Options");
72 -- Comments needed ???
74 package Libpath
is new Table
.Table
(
75 Table_Component_Type
=> Character,
76 Table_Index_Type
=> Integer,
78 Table_Initial
=> 4096,
79 Table_Increment
=> 100,
80 Table_Name
=> "Gnatlink.Libpath");
81 -- Comments needed ???
83 package Linker_Options
is new Table
.Table
(
84 Table_Component_Type
=> String_Access
,
85 Table_Index_Type
=> Integer,
88 Table_Increment
=> 100,
89 Table_Name
=> "Gnatlink.Linker_Options");
90 -- Comments needed ???
92 package Linker_Objects
is new Table
.Table
(
93 Table_Component_Type
=> String_Access
,
94 Table_Index_Type
=> Integer,
97 Table_Increment
=> 100,
98 Table_Name
=> "Gnatlink.Linker_Objects");
99 -- This table collects the objects file to be passed to the linker. In the
100 -- case where the linker command line is too long then programs objects
101 -- are put on the Response_File_Objects table. Note that the binder object
102 -- file and the user's objects remain in this table. This is very
103 -- important because on the GNU linker command line the -L switch is not
104 -- used to look for objects files but -L switch is used to look for
105 -- objects listed in the response file. This is not a problem with the
106 -- applications objects as they are specified with a full name.
108 package Response_File_Objects
is new Table
.Table
(
109 Table_Component_Type
=> String_Access
,
110 Table_Index_Type
=> Integer,
111 Table_Low_Bound
=> 1,
113 Table_Increment
=> 100,
114 Table_Name
=> "Gnatlink.Response_File_Objects");
115 -- This table collects the objects file that are to be put in the response
116 -- file. Only application objects are collected there (see details in
117 -- Linker_Objects table comments)
119 package Binder_Options_From_ALI
is new Table
.Table
(
120 Table_Component_Type
=> String_Access
,
121 Table_Index_Type
=> Integer,
122 Table_Low_Bound
=> 1, -- equals low bound of Argument_List for Spawn
124 Table_Increment
=> 100,
125 Table_Name
=> "Gnatlink.Binder_Options_From_ALI");
126 -- This table collects the switches from the ALI file of the main
129 package Binder_Options
is new Table
.Table
(
130 Table_Component_Type
=> String_Access
,
131 Table_Index_Type
=> Integer,
132 Table_Low_Bound
=> 1, -- equals low bound of Argument_List for Spawn
134 Table_Increment
=> 100,
135 Table_Name
=> "Gnatlink.Binder_Options");
136 -- This table collects the arguments to be passed to compile the binder
139 Gcc
: String_Access
:= Program_Name
("gcc", "gnatlink");
141 Read_Mode
: constant String := "r" & ASCII
.NUL
;
143 Begin_Info
: constant String := "-- BEGIN Object file/option list";
144 End_Info
: constant String := "-- END Object file/option list ";
146 Gcc_Path
: String_Access
;
147 Linker_Path
: String_Access
;
148 Output_File_Name
: String_Access
;
149 Ali_File_Name
: String_Access
;
150 Binder_Spec_Src_File
: String_Access
;
151 Binder_Body_Src_File
: String_Access
;
152 Binder_Ali_File
: String_Access
;
153 Binder_Obj_File
: String_Access
;
155 Base_Command_Name
: String_Access
;
157 Target_Debuggable_Suffix
: String_Access
;
159 Tname
: Temp_File_Name
;
160 Tname_FD
: File_Descriptor
:= Invalid_FD
;
161 -- Temporary file used by linker to pass list of object files on
162 -- certain systems with limitations on size of arguments.
164 Debug_Flag_Present
: Boolean := False;
165 Verbose_Mode
: Boolean := False;
166 Very_Verbose_Mode
: Boolean := False;
168 Standard_Gcc
: Boolean := True;
170 Compile_Bind_File
: Boolean := True;
171 -- Set to False if bind file is not to be compiled
173 Create_Map_File
: Boolean := False;
174 -- Set to True by switch -M. The map file name is derived from
175 -- the ALI file name (mainprog.ali => mainprog.map).
177 Object_List_File_Supported
: Boolean;
178 for Object_List_File_Supported
'Size use Character'Size;
180 (C
, Object_List_File_Supported
, "__gnat_objlist_file_supported");
181 -- Predicate indicating whether the linker has an option whereby the
182 -- names of object files can be passed to the linker in a file.
184 Object_File_Option_Ptr
: Interfaces
.C
.Strings
.chars_ptr
;
185 pragma Import
(C
, Object_File_Option_Ptr
, "__gnat_object_file_option");
186 -- Pointer to a string representing the linker option which specifies
187 -- the response file.
189 Object_File_Option
: constant String := Value
(Object_File_Option_Ptr
);
190 -- The linker option which specifies the response file as a string
192 Using_GNU_response_file
: constant Boolean :=
193 Object_File_Option
'Length > 0
194 and then Object_File_Option
(Object_File_Option
'Last) = '@';
195 -- Whether a GNU response file is used
197 Object_List_File_Required
: Boolean := False;
198 -- Set to True to force generation of a response file
200 Shared_Libgcc_Default
: Character;
201 for Shared_Libgcc_Default
'Size use Character'Size;
203 (C
, Shared_Libgcc_Default
, "__gnat_shared_libgcc_default");
204 -- Indicates wether libgcc should be statically linked (use 'T') or
205 -- dynamically linked (use 'H') by default.
207 function Base_Name
(File_Name
: String) return String;
208 -- Return just the file name part without the extension (if present)
210 procedure Check_Existing_Executable
(File_Name
: String);
211 -- Delete any existing executable to avoid accidentally updating the target
212 -- of a symbolic link, but produce a Fatail_Error if File_Name matches any
213 -- of the source file names. This avoids overwriting of extensionless
214 -- source files by accident on systems where executables do not have
217 procedure Delete
(Name
: String);
218 -- Wrapper to unlink as status is ignored by this application
220 procedure Error_Msg
(Message
: String);
221 -- Output the error or warning Message
223 procedure Exit_With_Error
(Error
: String);
224 -- Output Error and exit program with a fatal condition
226 procedure Process_Args
;
227 -- Go through all the arguments and build option tables
229 procedure Process_Binder_File
(Name
: String);
230 -- Reads the binder file and extracts linker arguments
235 procedure Write_Header
;
236 -- Show user the program name, version and copyright
238 procedure Write_Usage
;
239 -- Show user the program options
245 function Base_Name
(File_Name
: String) return String is
250 Findex1
:= File_Name
'First;
252 -- The file might be specified by a full path name. However,
253 -- we want the path to be stripped away.
255 for J
in reverse File_Name
'Range loop
256 if Is_Directory_Separator
(File_Name
(J
)) then
262 Findex2
:= File_Name
'Last;
263 while Findex2
> Findex1
and then File_Name
(Findex2
) /= '.' loop
264 Findex2
:= Findex2
- 1;
267 if Findex2
= Findex1
then
268 Findex2
:= File_Name
'Last + 1;
271 return File_Name
(Findex1
.. Findex2
- 1);
274 -------------------------------
275 -- Check_Existing_Executable --
276 -------------------------------
278 procedure Check_Existing_Executable
(File_Name
: String) is
279 Ename
: String := File_Name
;
280 Efile
: File_Name_Type
;
281 Sfile
: File_Name_Type
;
284 Canonical_Case_File_Name
(Ename
);
286 Add_Str_To_Name_Buffer
(Ename
);
289 for J
in Units
.Table
'First .. Units
.Last
loop
290 Sfile
:= Units
.Table
(J
).Sfile
;
291 if Sfile
= Efile
then
293 ("executable name """ & File_Name
& """ matches "
294 & "source file name """ & Get_Name_String
(Sfile
) & """");
299 end Check_Existing_Executable
;
305 procedure Delete
(Name
: String) is
307 pragma Unreferenced
(Status
);
309 Status
:= unlink
(Name
'Address);
310 -- Is it really right to ignore an error here ???
317 procedure Error_Msg
(Message
: String) is
319 Write_Str
(Base_Command_Name
.all);
325 ---------------------
326 -- Exit_With_Error --
327 ---------------------
329 procedure Exit_With_Error
(Error
: String) is
332 Exit_Program
(E_Fatal
);
339 procedure Process_Args
is
342 Skip_Next
: Boolean := False;
343 -- Set to true if the next argument is to be added into the list of
344 -- linker's argument without parsing it.
346 procedure Check_Version_And_Help
is new Check_Version_And_Help_G
(Usage
);
348 -- Start of processing for Process_Args
351 -- First, check for --version and --help
353 Check_Version_And_Help
("GNATLINK", "1996");
355 -- Loop through arguments of gnatlink command
359 exit when Next_Arg
> Argument_Count
;
361 Process_One_Arg
: declare
362 Arg
: constant String := Argument
(Next_Arg
);
365 -- Case of argument which is a switch
367 -- We definitely need section by section comments here ???
371 -- This argument must not be parsed, just add it to the
372 -- list of linker's options.
376 Linker_Options
.Increment_Last
;
377 Linker_Options
.Table
(Linker_Options
.Last
) :=
380 elsif Arg'Length /= 0 and then Arg (1) = '-' then
381 if Arg'Length > 4 and then Arg (2 .. 5) = "gnat" then
383 ("invalid switch: """ & Arg & """ (gnat not needed here)");
386 if Arg = "-Xlinker" then
388 -- Next argument should be sent directly to the linker.
389 -- We do not want to parse it here.
393 Linker_Options.Increment_Last;
394 Linker_Options.Table (Linker_Options.Last) :=
398 and then (Arg
'Length < 5 or else Arg
(2 .. 5) /= "gnat")
400 Debug_Flag_Present
:= True;
402 Linker_Options
.Increment_Last
;
403 Linker_Options
.Table
(Linker_Options
.Last
) :=
406 Binder_Options.Increment_Last;
407 Binder_Options.Table (Binder_Options.Last) :=
408 Linker_Options.Table (Linker_Options.Last);
410 elsif Arg'Length >= 3 and then Arg (2) = 'M
' then
412 Switches : String_List_Access;
415 Convert (Map_File, Arg (3 .. Arg'Last), Switches);
417 if Switches /= null then
418 for J in Switches'Range loop
419 Linker_Options.Increment_Last;
420 Linker_Options.Table (Linker_Options.Last) :=
426 elsif Arg'Length = 2 then
429 Linker_Options.Increment_Last;
430 Linker_Options.Table (Linker_Options.Last) :=
433 Binder_Options
.Increment_Last
;
434 Binder_Options
.Table
(Binder_Options
.Last
) :=
435 Linker_Options
.Table
(Linker_Options
.Last
);
437 Next_Arg
:= Next_Arg
+ 1;
439 if Next_Arg
> Argument_Count
then
440 Exit_With_Error
("Missing argument for -b");
443 Get_Machine_Name
: declare
444 Name_Arg
: constant String_Access
:=
445 new String'(Argument (Next_Arg));
448 Linker_Options.Increment_Last;
449 Linker_Options.Table (Linker_Options.Last) :=
452 Binder_Options.Increment_Last;
453 Binder_Options.Table (Binder_Options.Last) :=
456 end Get_Machine_Name;
459 if Object_List_File_Supported then
460 Object_List_File_Required := True;
463 ("Object list file not supported on this target");
467 Create_Map_File := True;
470 Compile_Bind_File := False;
473 Next_Arg := Next_Arg + 1;
475 if Next_Arg > Argument_Count then
476 Exit_With_Error ("Missing argument for -o");
480 new String'(Executable_Name
481 (Argument
(Next_Arg
),
482 Only_If_No_Suffix
=> True));
485 Opt
.CodePeer_Mode
:= True;
488 Opt
.Run_Path_Option
:= False;
492 -- Support "double" verbose mode. Second -v
493 -- gets sent to the linker and binder phases.
496 Very_Verbose_Mode
:= True;
498 Linker_Options
.Increment_Last
;
499 Linker_Options
.Table
(Linker_Options
.Last
) :=
502 Binder_Options.Increment_Last;
503 Binder_Options.Table (Binder_Options.Last) :=
504 Linker_Options.Table (Linker_Options.Last);
507 Verbose_Mode := True;
512 Linker_Options.Increment_Last;
513 Linker_Options.Table (Linker_Options.Last) :=
518 elsif Arg
(2) = 'B' then
519 Linker_Options
.Increment_Last
;
520 Linker_Options
.Table
(Linker_Options
.Last
) :=
523 Binder_Options.Increment_Last;
524 Binder_Options.Table (Binder_Options.Last) :=
525 Linker_Options.Table (Linker_Options.Last);
527 elsif Arg'Length >= 7 and then Arg (1 .. 7) = "--LINK=" then
528 if Arg'Length = 7 then
529 Exit_With_Error ("Missing argument for --LINK=");
533 System.OS_Lib.Locate_Exec_On_Path (Arg (8 .. Arg'Last));
535 if Linker_Path = null then
537 ("Could not locate linker: " & Arg (8 .. Arg'Last));
540 elsif Arg'Length > 6 and then Arg (1 .. 6) = "--GCC=" then
542 Program_Args : constant Argument_List_Access :=
543 Argument_String_To_List
544 (Arg (7 .. Arg'Last));
547 if Program_Args.all (1).all /= Gcc.all then
548 Gcc := new String'(Program_Args
.all (1).all);
549 Standard_Gcc
:= False;
552 -- Set appropriate flags for switches passed
554 for J
in 2 .. Program_Args
.all'Last loop
556 Arg
: constant String := Program_Args
.all (J
).all;
557 AF
: constant Integer := Arg
'First;
560 if Arg
'Length /= 0 and then Arg
(AF
) = '-' then
561 if Arg
(AF
+ 1) = 'g'
562 and then (Arg
'Length = 2
563 or else Arg
(AF
+ 2) in '0' .. '3'
564 or else Arg
(AF
+ 2 .. Arg
'Last) = "coff")
566 Debug_Flag_Present
:= True;
570 -- Add directory to source search dirs so that
571 -- Get_Target_Parameters can find system.ads
573 if Arg
(AF
.. AF
+ 1) = "-I"
574 and then Arg
'Length > 2
576 Add_Src_Search_Dir
(Arg
(AF
+ 2 .. Arg
'Last));
579 -- Pass to gcc for compiling binder generated file
580 -- No use passing libraries, it will just generate
583 if not (Arg
(AF
.. AF
+ 1) = "-l"
584 or else Arg
(AF
.. AF
+ 1) = "-L")
586 Binder_Options
.Increment_Last
;
587 Binder_Options
.Table
(Binder_Options
.Last
) :=
591 -- Pass to gcc for linking program
593 Gcc_Linker_Options.Increment_Last;
594 Gcc_Linker_Options.Table
595 (Gcc_Linker_Options.Last) := new String'(Arg
);
600 -- Send all multi-character switches not recognized as
601 -- a special case by gnatlink to the linker/loader stage.
604 Linker_Options
.Increment_Last
;
605 Linker_Options
.Table
(Linker_Options
.Last
) :=
609 -- Here if argument is a file name rather than a switch
612 -- If explicit ali file, capture it
615 and then Arg (Arg'Last - 3 .. Arg'Last) = ".ali"
617 if Ali_File_Name = null then
618 Ali_File_Name := new String'(Arg
);
620 Exit_With_Error
("cannot handle more than one ALI file");
623 -- If target object file, record object file
625 elsif Arg
'Length > Get_Target_Object_Suffix
.all'Length
628 Get_Target_Object_Suffix
.all'Length + 1 .. Arg
'Last)
629 = Get_Target_Object_Suffix
.all
631 Linker_Objects
.Increment_Last
;
632 Linker_Objects
.Table
(Linker_Objects
.Last
) :=
635 -- If host object file, record object file
637 elsif Arg'Length > Get_Object_Suffix.all'Length
639 (Arg'Last - Get_Object_Suffix.all'Length + 1 .. Arg'Last)
640 = Get_Object_Suffix.all
642 Linker_Objects.Increment_Last;
643 Linker_Objects.Table (Linker_Objects.Last) :=
646 -- If corresponding ali file exists, capture it
648 elsif Ali_File_Name
= null
649 and then Is_Regular_File
(Arg
& ".ali")
651 Ali_File_Name
:= new String'(Arg & ".ali");
653 -- Otherwise assume this is a linker options entry, but
654 -- see below for interesting adjustment to this assumption.
657 Linker_Options.Increment_Last;
658 Linker_Options.Table (Linker_Options.Last) :=
664 Next_Arg
:= Next_Arg
+ 1;
667 -- Compile the bind file with warnings suppressed, because
668 -- otherwise the with of the main program may cause junk warnings.
670 Binder_Options
.Increment_Last
;
671 Binder_Options
.Table
(Binder_Options
.Last
) := new String'("-gnatws");
673 -- If we did not get an ali file at all, and we had at least one
674 -- linker option, then assume that was the intended ali file after
675 -- all, so that we get a nicer message later on.
677 if Ali_File_Name = null
678 and then Linker_Options.Last >= Linker_Options.First
681 new String'(Linker_Options
.Table
(Linker_Options
.First
).all
686 -------------------------
687 -- Process_Binder_File --
688 -------------------------
690 procedure Process_Binder_File
(Name
: String) is
692 -- Binder file's descriptor
694 Link_Bytes
: Integer := 0;
695 -- Projected number of bytes for the linker command line
698 pragma Import
(C
, Link_Max
, "__gnat_link_max");
699 -- Maximum number of bytes on the command line supported by the OS
700 -- linker. Passed this limit the response file mechanism must be used
703 Next_Line
: String (1 .. 1000);
704 -- Current line value
708 -- Current line slice (the slice does not contain line terminator)
711 -- Current line last character for shared libraries (without version)
713 Objs_Begin
: Integer := 0;
714 -- First object file index in Linker_Objects table
716 Objs_End
: Integer := 0;
717 -- Last object file index in Linker_Objects table
720 pragma Warnings
(Off
, Status
);
721 -- Used for various Interfaces.C_Streams calls
723 Closing_Status
: Boolean;
724 pragma Warnings
(Off
, Closing_Status
);
727 GNAT_Static
: Boolean := False;
728 -- Save state of -static option
730 GNAT_Shared
: Boolean := False;
731 -- Save state of -shared option
733 Xlinker_Was_Previous
: Boolean := False;
734 -- Indicate that "-Xlinker" was the option preceding the current option.
735 -- If True, then the current option is never suppressed.
739 -- These data items are used to store current binder file context. The
740 -- context is composed of the file descriptor position and the current
741 -- line together with the slice indexes (first and last position) for
742 -- this line. The rollback data are used by the Store_File_Context and
743 -- Rollback_File_Context routines below. The file context mechanism
744 -- interact only with the Get_Next_Line call. For example:
746 -- Store_File_Context;
748 -- Rollback_File_Context;
751 -- Both Get_Next_Line calls above will read the exact same data from
752 -- the file. In other words, Next_Line, Nfirst and Nlast variables
753 -- will be set with the exact same values.
755 RB_File_Pos
: long
; -- File position
756 RB_Next_Line
: String (1 .. 1000); -- Current line content
757 RB_Nlast
: Integer; -- Slice last index
758 RB_Nfirst
: Integer; -- Slice first index
760 Run_Path_Option_Ptr
: Interfaces
.C
.Strings
.chars_ptr
;
761 pragma Import
(C
, Run_Path_Option_Ptr
, "__gnat_run_path_option");
762 -- Pointer to string representing the native linker option which
763 -- specifies the path where the dynamic loader should find shared
764 -- libraries. Equal to null string if this system doesn't support it.
766 Libgcc_Subdir_Ptr
: Interfaces
.C
.Strings
.chars_ptr
;
767 pragma Import
(C
, Libgcc_Subdir_Ptr
, "__gnat_default_libgcc_subdir");
768 -- Pointer to string indicating the installation subdirectory where
769 -- a default shared libgcc might be found.
771 Object_Library_Ext_Ptr
: Interfaces
.C
.Strings
.chars_ptr
;
773 (C
, Object_Library_Ext_Ptr
, "__gnat_object_library_extension");
774 -- Pointer to string specifying the default extension for
775 -- object libraries, e.g. Unix uses ".a".
777 Separate_Run_Path_Options
: Boolean;
778 for Separate_Run_Path_Options
'Size use Character'Size;
780 (C
, Separate_Run_Path_Options
, "__gnat_separate_run_path_options");
781 -- Whether separate rpath options should be emitted for each directory
783 procedure Get_Next_Line
;
784 -- Read the next line from the binder file without the line
787 function Index
(S
, Pattern
: String) return Natural;
788 -- Return the last occurrence of Pattern in S, or 0 if none
790 procedure Store_File_Context
;
791 -- Store current file context, Fd position and current line data.
792 -- The file context is stored into the rollback data above (RB_*).
793 -- Store_File_Context can be called at any time, only the last call
794 -- will be used (i.e. this routine overwrites the file context).
796 procedure Rollback_File_Context
;
797 -- Restore file context from rollback data. This routine must be called
798 -- after Store_File_Context. The binder file context will be restored
799 -- with the data stored by the last Store_File_Context call.
801 procedure Write_RF
(S
: String);
802 -- Write a string to the response file and check if it was successful.
803 -- Fail the program if it was not successful (disk full).
809 procedure Get_Next_Line
is
813 Fchars
:= fgets
(Next_Line
'Address, Next_Line
'Length, Fd
);
815 if Fchars
= System
.Null_Address
then
816 Exit_With_Error
("Error reading binder output");
819 Nfirst
:= Next_Line
'First;
821 while Nlast
<= Next_Line
'Last
822 and then Next_Line
(Nlast
) /= ASCII
.LF
823 and then Next_Line
(Nlast
) /= ASCII
.CR
835 function Index
(S
, Pattern
: String) return Natural is
836 Len
: constant Natural := Pattern
'Length;
839 for J
in reverse S
'First .. S
'Last - Len
+ 1 loop
840 if Pattern
= S
(J
.. J
+ Len
- 1) then
848 ---------------------------
849 -- Rollback_File_Context --
850 ---------------------------
852 procedure Rollback_File_Context
is
854 Next_Line
:= RB_Next_Line
;
857 Status
:= fseek
(Fd
, RB_File_Pos
, Interfaces
.C_Streams
.SEEK_SET
);
860 Exit_With_Error
("Error setting file position");
862 end Rollback_File_Context
;
864 ------------------------
865 -- Store_File_Context --
866 ------------------------
868 procedure Store_File_Context
is
869 use type System
.CRTL
.long
;
872 RB_Next_Line
:= Next_Line
;
875 RB_File_Pos
:= ftell
(Fd
);
877 if RB_File_Pos
= -1 then
878 Exit_With_Error
("Error getting file position");
880 end Store_File_Context
;
886 procedure Write_RF
(S
: String) is
887 Success
: Boolean := True;
888 Back_Slash
: constant Character := '\';
891 -- If a GNU response file is used, space and backslash need to be
892 -- escaped because they are interpreted as a string separator and
893 -- an escape character respectively by the underlying mechanism.
894 -- On the other hand, quote and double-quote are not escaped since
895 -- they are interpreted as string delimiters on both sides.
897 if Using_GNU_response_file
then
898 for J
in S
'Range loop
899 if S
(J
) = ' ' or else S
(J
) = '\' then
900 if Write
(Tname_FD
, Back_Slash
'Address, 1) /= 1 then
905 if Write
(Tname_FD
, S
(J
)'Address, 1) /= 1 then
911 if Write
(Tname_FD
, S
'Address, S
'Length) /= S
'Length then
916 if Write
(Tname_FD
, ASCII
.LF
'Address, 1) /= 1 then
921 Exit_With_Error
("Error generating response file: disk full");
925 -- Start of processing for Process_Binder_File
928 Fd
:= fopen
(Name
'Address, Read_Mode
'Address);
930 if Fd
= NULL_Stream
then
931 Exit_With_Error
("Failed to open binder output");
934 -- Skip up to the Begin Info line
938 exit when Next_Line
(Nfirst
.. Nlast
) = Begin_Info
;
944 -- Go to end when end line is reached (this will happen in
945 -- High_Integrity_Mode where no -L switches are generated)
947 exit when Next_Line
(Nfirst
.. Nlast
) = End_Info
;
949 Next_Line
(Nfirst
.. Nlast
- 8) := Next_Line
(Nfirst
+ 8 .. Nlast
);
952 -- Go to next section when switches are reached
954 exit when Next_Line
(1) = '-';
956 -- Otherwise we have another object file to collect
958 Linker_Objects
.Increment_Last
;
960 -- Mark the positions of first and last object files in case they
961 -- need to be placed with a named file on systems having linker
964 if Objs_Begin
= 0 then
965 Objs_Begin
:= Linker_Objects
.Last
;
968 Linker_Objects
.Table
(Linker_Objects
.Last
) :=
969 new String'(Next_Line (Nfirst .. Nlast));
971 -- Nlast - Nfirst + 1, for the size, plus one for the space between
974 Link_Bytes := Link_Bytes + Nlast - Nfirst + 2;
977 Objs_End := Linker_Objects.Last;
979 -- Continue to compute the Link_Bytes, the linker options are part of
980 -- command line length.
984 while Next_Line (Nfirst .. Nlast) /= End_Info loop
985 Link_Bytes := Link_Bytes + Nlast - Nfirst + 2;
989 Rollback_File_Context;
991 -- On systems that have limitations on handling very long linker lines
992 -- we make use of the system linker option which takes a list of object
993 -- file names from a file instead of the command line itself. What we do
994 -- is to replace the list of object files by the special linker option
995 -- which then reads the object file list from a file instead. The option
996 -- to read from a file instead of the command line is only triggered if
997 -- a conservative threshold is passed.
999 if Object_List_File_Required
1000 or else (Object_List_File_Supported
1001 and then Link_Bytes > Link_Max)
1003 -- Create a temporary file containing the Ada user object files
1004 -- needed by the link. This list is taken from the bind file and is
1005 -- output one object per line for maximal compatibility with linkers
1006 -- supporting this option.
1008 Create_Temp_File (Tname_FD, Tname);
1010 -- ??? File descriptor should be checked to not be Invalid_FD.
1011 -- ??? Status of Write and Close operations should be checked, and
1012 -- failure should occur if a status is wrong.
1014 for J in Objs_Begin .. Objs_End loop
1015 Write_RF (Linker_Objects.Table (J).all);
1017 Response_File_Objects.Increment_Last;
1018 Response_File_Objects.Table (Response_File_Objects.Last) :=
1019 Linker_Objects.Table (J);
1022 Close (Tname_FD, Closing_Status);
1024 -- Add the special objects list file option together with the name
1025 -- of the temporary file (removing the null character) to the objects
1028 Linker_Objects.Table (Objs_Begin) :=
1029 new String'(Object_File_Option
&
1030 Tname
(Tname
'First .. Tname
'Last - 1));
1032 -- The slots containing these object file names are then removed
1033 -- from the objects table so they do not appear in the link. They are
1034 -- removed by moving up the linker options and non-Ada object files
1035 -- appearing after the Ada object list in the table.
1041 N
:= Objs_End
- Objs_Begin
+ 1;
1043 for J
in Objs_End
+ 1 .. Linker_Objects
.Last
loop
1044 Linker_Objects
.Table
(J
- N
+ 1) := Linker_Objects
.Table
(J
);
1047 Linker_Objects
.Set_Last
(Linker_Objects
.Last
- N
+ 1);
1051 -- Process switches and options
1053 if Next_Line
(Nfirst
.. Nlast
) /= End_Info
then
1054 Xlinker_Was_Previous
:= False;
1057 if Xlinker_Was_Previous
1058 or else Next_Line
(Nfirst
.. Nlast
) = "-Xlinker"
1060 Linker_Options
.Increment_Last
;
1061 Linker_Options
.Table
(Linker_Options
.Last
) :=
1062 new String'(Next_Line (Nfirst .. Nlast));
1064 elsif Next_Line (Nfirst .. Nlast) = "-static" then
1065 GNAT_Static := True;
1067 elsif Next_Line (Nfirst .. Nlast) = "-shared" then
1068 GNAT_Shared := True;
1070 -- Add binder options only if not already set on the command line.
1071 -- This rule is a way to control the linker options order.
1074 if Nlast > Nfirst + 2 and then
1075 Next_Line (Nfirst .. Nfirst + 1) = "-L"
1077 -- Construct a library search path for use later to locate
1078 -- static gnatlib libraries.
1080 if Libpath.Last > 1 then
1081 Libpath.Increment_Last;
1082 Libpath.Table (Libpath.Last) := Path_Separator;
1085 for I in Nfirst + 2 .. Nlast loop
1086 Libpath.Increment_Last;
1087 Libpath.Table (Libpath.Last) := Next_Line (I);
1090 Linker_Options.Increment_Last;
1092 Linker_Options.Table (Linker_Options.Last) :=
1093 new String'(Next_Line
(Nfirst
.. Nlast
));
1095 elsif Next_Line
(Nfirst
.. Nlast
) = "-lgnarl"
1096 or else Next_Line
(Nfirst
.. Nlast
) = "-lgnat"
1099 (1 .. Natural'Min (Nlast
, 8 + Library_Version
'Length)) =
1100 Shared_Lib
("gnarl")
1103 (1 .. Natural'Min (Nlast
, 7 + Library_Version
'Length)) =
1106 -- If it is a shared library, remove the library version.
1107 -- We will be looking for the static version of the library
1108 -- as it is in the same directory as the shared version.
1110 if Next_Line
(Nlast
- Library_Version
'Length + 1 .. Nlast
) =
1113 -- Set Last to point to last character before the
1116 Last
:= Nlast
- Library_Version
'Length - 1;
1121 -- Given a Gnat standard library, search the library path to
1122 -- find the library location.
1124 -- Shouldn't we abstract a proc here, we are getting awfully
1125 -- heavily nested ???
1128 File_Path
: String_Access
;
1130 Object_Lib_Extension
: constant String :=
1131 Value
(Object_Library_Ext_Ptr
);
1133 File_Name
: constant String := "lib" &
1134 Next_Line
(Nfirst
+ 2 .. Last
) & Object_Lib_Extension
;
1136 Run_Path_Opt
: constant String :=
1137 Value
(Run_Path_Option_Ptr
);
1139 GCC_Index
: Natural;
1140 Run_Path_Opt_Index
: Natural := 0;
1144 Locate_Regular_File
(File_Name
,
1145 String (Libpath
.Table
(1 .. Libpath
.Last
)));
1147 if File_Path
/= null then
1150 -- If static gnatlib found, explicitly specify to
1151 -- overcome possible linker default usage of shared
1154 Linker_Options
.Increment_Last
;
1156 Linker_Options
.Table
(Linker_Options
.Last
) :=
1157 new String'(File_Path.all);
1159 elsif GNAT_Shared then
1160 if Opt.Run_Path_Option then
1162 -- If shared gnatlib desired, add appropriate
1163 -- system specific switch so that it can be
1164 -- located at runtime.
1166 if Run_Path_Opt'Length /= 0 then
1168 -- Output the system specific linker command
1169 -- that allows the image activator to find
1170 -- the shared library at runtime. Also add
1171 -- path to find libgcc_s.so, if relevant.
1174 Path : String (1 .. File_Path'Length + 15);
1176 Path_Last : constant Natural :=
1180 Path (1 .. File_Path'Length) :=
1183 -- To find the location of the shared version
1184 -- of libgcc, we look for "gcc-lib" in the
1185 -- path of the library. However, this
1186 -- subdirectory is no longer present in
1187 -- recent versions of GCC. So, we look for
1188 -- the last subdirectory "lib" in the path.
1191 Index (Path (1 .. Path_Last), "gcc-lib");
1193 if GCC_Index /= 0 then
1195 -- The shared version of libgcc is
1196 -- located in the parent directory.
1198 GCC_Index := GCC_Index - 1;
1203 (Path (1 .. Path_Last),
1206 if GCC_Index = 0 then
1208 Index (Path (1 .. Path_Last),
1209 Directory_Separator & "lib"
1210 & Directory_Separator);
1213 -- If we have found a "lib" subdir in
1214 -- the path to libgnat, the possible
1215 -- shared libgcc of interest by default
1216 -- is in libgcc_subdir at the same
1219 if GCC_Index /= 0 then
1221 Subdir : constant String :=
1222 Value (Libgcc_Subdir_Ptr);
1226 GCC_Index + Subdir'Length) :=
1229 GCC_Index + Subdir'Length;
1234 -- Look for an eventual run_path_option in
1235 -- the linker switches.
1237 if Separate_Run_Path_Options then
1238 Linker_Options.Increment_Last;
1239 Linker_Options.Table
1240 (Linker_Options.Last) :=
1244 (1 .. File_Path
'Length
1245 - File_Name
'Length));
1247 if GCC_Index
/= 0 then
1248 Linker_Options
.Increment_Last
;
1249 Linker_Options
.Table
1250 (Linker_Options
.Last
) :=
1253 & Path (1 .. GCC_Index));
1258 1 .. Linker_Options.Last
1260 if Linker_Options.Table (J) /= null
1262 Linker_Options.Table (J)'Length
1263 > Run_Path_Opt'Length
1265 Linker_Options.Table (J)
1266 (1 .. Run_Path_Opt'Length) =
1269 -- We have found an already
1270 -- specified run_path_option:
1271 -- we will add to this
1272 -- switch, because only one
1273 -- run_path_option should be
1276 Run_Path_Opt_Index := J;
1281 -- If there is no run_path_option, we
1284 if Run_Path_Opt_Index = 0 then
1285 Linker_Options.Increment_Last;
1288 if GCC_Index = 0 then
1289 if Run_Path_Opt_Index = 0 then
1290 Linker_Options.Table
1291 (Linker_Options.Last) :=
1295 (1 .. File_Path
'Length
1296 - File_Name
'Length));
1299 Linker_Options
.Table
1300 (Run_Path_Opt_Index
) :=
1302 (Linker_Options.Table
1303 (Run_Path_Opt_Index).all
1306 (1 .. File_Path'Length
1307 - File_Name'Length));
1311 if Run_Path_Opt_Index = 0 then
1312 Linker_Options.Table
1313 (Linker_Options.Last) :=
1317 (1 .. File_Path
'Length
1320 & Path
(1 .. GCC_Index
));
1323 Linker_Options
.Table
1324 (Run_Path_Opt_Index
) :=
1326 (Linker_Options.Table
1327 (Run_Path_Opt_Index).all
1330 (1 .. File_Path'Length
1333 & Path (1 .. GCC_Index));
1341 -- Then we add the appropriate -l switch
1343 Linker_Options.Increment_Last;
1344 Linker_Options.Table (Linker_Options.Last) :=
1345 new String'(Next_Line
(Nfirst
.. Nlast
));
1349 -- If gnatlib library not found, then add it anyway in
1350 -- case some other mechanism may find it.
1352 Linker_Options
.Increment_Last
;
1353 Linker_Options
.Table
(Linker_Options
.Last
) :=
1354 new String'(Next_Line (Nfirst .. Nlast));
1358 Linker_Options.Increment_Last;
1359 Linker_Options.Table (Linker_Options.Last) :=
1360 new String'(Next_Line
(Nfirst
.. Nlast
));
1364 Xlinker_Was_Previous
:= Next_Line
(Nfirst
.. Nlast
) = "-Xlinker";
1367 exit when Next_Line
(Nfirst
.. Nlast
) = End_Info
;
1369 Next_Line
(Nfirst
.. Nlast
- 8) := Next_Line
(Nfirst
+ 8 .. Nlast
);
1374 -- If -shared was specified, invoke gcc with -shared-libgcc
1377 Linker_Options
.Increment_Last
;
1378 Linker_Options
.Table
(Linker_Options
.Last
) := Shared_Libgcc
;
1381 Status
:= fclose
(Fd
);
1382 end Process_Binder_File
;
1390 Write_Str
("Usage: ");
1391 Write_Str
(Base_Command_Name
.all);
1392 Write_Str
(" switches mainprog.ali [non-Ada-objects] [linker-options]");
1395 Write_Line
(" mainprog.ali the ALI file of the main program");
1398 Display_Usage_Version_And_Help
;
1399 Write_Line
(" -f Force object file list to be generated");
1400 Write_Line
(" -g Compile binder source file with debug information");
1401 Write_Line
(" -n Do not compile the binder source file");
1402 Write_Line
(" -P Process files for use by CodePeer");
1403 Write_Line
(" -R Do not use a run_path_option");
1404 Write_Line
(" -v Verbose mode");
1405 Write_Line
(" -v -v Very verbose mode");
1407 Write_Line
(" -o nam Use 'nam' as the name of the executable");
1408 Write_Line
(" -b target Compile the binder source to run on target");
1409 Write_Line
(" -Bdir Load compiler executables from dir");
1411 if Is_Supported
(Map_File
) then
1412 Write_Line
(" -Mmap Create map file map");
1413 Write_Line
(" -M Create map file mainprog.map");
1416 Write_Line
(" --GCC=comp Use comp as the compiler");
1417 Write_Line
(" --LINK=nam Use 'nam' for the linking rather than 'gcc'");
1419 Write_Line
(" [non-Ada-objects] list of non Ada object files");
1420 Write_Line
(" [linker-options] other options for the linker");
1427 procedure Write_Header
is
1429 if Verbose_Mode
then
1431 Display_Version
("GNATLINK", "1995");
1439 procedure Write_Usage
is
1445 -- Start of processing for Gnatlink
1448 -- Add the directory where gnatlink is invoked in front of the path, if
1449 -- gnatlink is invoked with directory information.
1452 Command
: constant String := Command_Name
;
1454 for Index
in reverse Command
'Range loop
1455 if Command
(Index
) = Directory_Separator
then
1457 Absolute_Dir
: constant String :=
1459 (Command
(Command
'First .. Index
));
1461 PATH
: constant String :=
1464 Getenv
("PATH").all;
1467 Setenv
("PATH", PATH
);
1475 Base_Command_Name
:= new String'(Base_Name (Command_Name));
1478 if Argument_Count = 0
1479 or else (Verbose_Mode and then Argument_Count = 1)
1482 Exit_Program (E_Fatal);
1485 -- Initialize packages to be used
1490 -- We always compile with -c
1492 Binder_Options_From_ALI.Increment_Last;
1493 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1496 if Ali_File_Name
= null then
1497 Exit_With_Error
("no ali file given for link");
1500 if not Is_Regular_File
(Ali_File_Name
.all) then
1501 Exit_With_Error
(Ali_File_Name
.all & " not found");
1504 -- Read the ALI file of the main subprogram if the binder generated file
1505 -- needs to be compiled and no --GCC= switch has been specified. Fetch the
1506 -- back end switches from this ALI file and use these switches to compile
1507 -- the binder generated file
1509 if Compile_Bind_File
and then Standard_Gcc
then
1511 Name_Len
:= Ali_File_Name
'Length;
1512 Name_Buffer
(1 .. Name_Len
) := Ali_File_Name
.all;
1516 F
: constant File_Name_Type
:= Name_Find
;
1517 T
: Text_Buffer_Ptr
;
1521 -- Load the ALI file
1523 T
:= Read_Library_Info
(F
, True);
1525 -- Read it. Note that we ignore errors, since we only want very
1526 -- limited information from the ali file, and likely a slightly
1527 -- wrong version will be just fine, though in normal operation
1528 -- we don't expect this to happen.
1535 Ignore_Errors
=> True);
1537 if A
/= No_ALI_Id
then
1539 Index
in Units
.Table
(ALIs
.Table
(A
).First_Unit
).First_Arg
..
1540 Units
.Table
(ALIs
.Table
(A
).First_Unit
).Last_Arg
1542 -- Do not compile with the front end switches. However, --RTS
1543 -- is to be dealt with specially because it needs to be passed
1544 -- to compile the file generated by the binder.
1547 Arg
: String_Ptr
renames Args
.Table
(Index
);
1549 if not Is_Front_End_Switch
(Arg
.all) then
1550 Binder_Options_From_ALI
.Increment_Last
;
1551 Binder_Options_From_ALI
.Table
1552 (Binder_Options_From_ALI
.Last
) := String_Access
(Arg
);
1554 -- GNAT doesn't support GCC's multilib mechanism when it
1555 -- is configured with --disable-libada. This means that,
1556 -- when a multilib switch is used to request a particular
1557 -- compilation mode, the corresponding --RTS switch must
1558 -- also be specified. It is convenient to eliminate the
1559 -- redundancy by keying the compilation mode on a single
1560 -- switch, namely --RTS, and have the compiler reinstate
1561 -- the multilib switch (see gcc-interface/lang-specs.h).
1562 -- This switch must be passed to the driver at link time.
1565 and then Arg
(Arg
'First + 1 .. Arg
'First + 4) = "mrtp"
1567 Linker_Options
.Increment_Last
;
1568 Linker_Options
.Table
1569 (Linker_Options
.Last
) := String_Access
(Arg
);
1572 elsif Arg
'Length > 5
1573 and then Arg
(Arg
'First + 2 .. Arg
'First + 5) = "RTS="
1575 Binder_Options_From_ALI
.Increment_Last
;
1576 Binder_Options_From_ALI
.Table
1577 (Binder_Options_From_ALI
.Last
) := String_Access
(Arg
);
1579 -- Set the RTS_*_Path_Name variables, so that
1580 -- the correct directories will be set when
1581 -- Osint.Add_Default_Search_Dirs will be called later.
1583 Opt
.RTS_Src_Path_Name
:=
1585 (Arg
(Arg
'First + 6 .. Arg
'Last), Include
);
1587 Opt
.RTS_Lib_Path_Name
:=
1589 (Arg
(Arg
'First + 6 .. Arg
'Last), Objects
);
1597 -- Get target parameters
1599 Osint
.Add_Default_Search_Dirs
;
1600 Targparm
.Get_Target_Parameters
;
1602 -- Compile the bind file with the following switches:
1604 -- -gnatA stops reading gnat.adc, since we don't know what
1605 -- pragmas would work, and we do not need it anyway.
1607 -- -gnatWb allows brackets coding for wide characters
1609 -- -gnatiw allows wide characters in identifiers. This is needed
1610 -- because bindgen uses brackets encoding for all upper
1611 -- half and wide characters in identifier names.
1613 -- In addition, in CodePeer mode compile with -x adascil -gnatcC
1615 Binder_Options_From_ALI
.Increment_Last
;
1616 Binder_Options_From_ALI
.Table
(Binder_Options_From_ALI
.Last
) :=
1617 new String'("-gnatA");
1618 Binder_Options_From_ALI.Increment_Last;
1619 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1620 new String'("-gnatWb");
1621 Binder_Options_From_ALI
.Increment_Last
;
1622 Binder_Options_From_ALI
.Table
(Binder_Options_From_ALI
.Last
) :=
1623 new String'("-gnatiw");
1625 if Opt.CodePeer_Mode then
1626 Binder_Options_From_ALI.Increment_Last;
1627 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1629 Binder_Options_From_ALI
.Increment_Last
;
1630 Binder_Options_From_ALI
.Table
(Binder_Options_From_ALI
.Last
) :=
1631 new String'("adascil");
1632 Binder_Options_From_ALI.Increment_Last;
1633 Binder_Options_From_ALI.Table (Binder_Options_From_ALI.Last) :=
1634 new String'("-gnatcC");
1637 -- Locate all the necessary programs and verify required files are present
1639 Gcc_Path
:= System
.OS_Lib
.Locate_Exec_On_Path
(Gcc
.all);
1641 if Gcc_Path
= null then
1642 Exit_With_Error
("Couldn't locate " & Gcc
.all);
1645 if Linker_Path
= null then
1646 Linker_Path
:= Gcc_Path
;
1651 Target_Debuggable_Suffix
:= Get_Target_Debuggable_Suffix
;
1653 -- If no output name specified, then use the base name of .ali file name
1655 if Output_File_Name
= null then
1657 new String'(Base_Name (Ali_File_Name.all)
1658 & Target_Debuggable_Suffix.all);
1661 Linker_Options.Increment_Last;
1662 Linker_Options.Table (Linker_Options.Last) := new String'("-o");
1664 Linker_Options
.Increment_Last
;
1665 Linker_Options
.Table
(Linker_Options
.Last
) :=
1666 new String'(Output_File_Name.all);
1668 Check_Existing_Executable (Output_File_Name.all);
1670 -- Warn if main program is called "test", as that may be a built-in command
1671 -- on Unix. On non-Unix systems executables have a suffix, so the warning
1672 -- will not appear. However, do not warn in the case of a cross compiler.
1674 -- Assume this is a cross tool if the executable name is not gnatlink.
1675 -- Note that the executable name is also gnatlink on windows, but in that
1676 -- case the output file name will be test.exe rather than test.
1678 if Base_Command_Name.all = "gnatlink"
1679 and then Output_File_Name.all = "test"
1681 Error_Msg ("warning: executable name """ & Output_File_Name.all
1682 & """ may conflict with shell command");
1685 -- Special warnings for worrisome file names on windows
1687 -- Recent versions of Windows by default cause privilege escalation if an
1688 -- executable file name contains substrings "install", "setup", "update"
1689 -- or "patch". A console application will typically fail to load as a
1690 -- result, so we should warn the user.
1692 Bad_File_Names_On_Windows : declare
1693 FN : String := Output_File_Name.all;
1695 procedure Check_File_Name (S : String);
1696 -- Warn if file name has the substring S
1698 procedure Check_File_Name (S : String) is
1700 for J in 1 .. FN'Length - (S'Length - 1) loop
1701 if FN (J .. J + (S'Length - 1)) = S then
1703 ("warning: executable file name """ & Output_File_Name.all
1704 & """ contains substring """ & S & '"');
1706 ("admin privileges may be required to run this file
");
1709 end Check_File_Name;
1711 -- Start of processing for Bad_File_Names_On_Windows
1714 for J in FN'Range loop
1715 FN (J) := Csets.Fold_Lower (FN (J));
1718 -- For now we detect Windows by its executable suffix of .exe
1720 if Target_Debuggable_Suffix.all = ".exe
" then
1721 Check_File_Name ("install
");
1722 Check_File_Name ("setup
");
1723 Check_File_Name ("update
");
1724 Check_File_Name ("patch
");
1726 end Bad_File_Names_On_Windows;
1728 -- If -M switch was specified, add the switches to create the map file
1730 if Create_Map_File then
1732 Map_Name : constant String := Base_Name (Ali_File_Name.all) & ".map
";
1733 Switches : String_List_Access;
1736 Convert (Map_File, Map_Name, Switches);
1738 if Switches /= null then
1739 for J in Switches'Range loop
1740 Linker_Options.Increment_Last;
1741 Linker_Options.Table (Linker_Options.Last) := Switches (J);
1747 -- Perform consistency checks
1749 -- Transform the .ali file name into the binder output file name
1751 Make_Binder_File_Names : declare
1752 Fname : constant String := Base_Name (Ali_File_Name.all);
1753 Fname_Len : Integer := Fname'Length;
1755 function Get_Maximum_File_Name_Length return Integer;
1756 pragma Import (C, Get_Maximum_File_Name_Length,
1757 "__gnat_get_maximum_file_name_length
");
1759 Maximum_File_Name_Length : constant Integer :=
1760 Get_Maximum_File_Name_Length;
1762 Bind_File_Prefix : Types.String_Ptr;
1763 -- Contains prefix used for bind files
1768 Bind_File_Prefix := new String'("b~
");
1770 -- If the length of the binder file becomes too long due to
1771 -- the addition of the "b?
" prefix, then truncate it.
1773 if Maximum_File_Name_Length > 0 then
1775 Maximum_File_Name_Length - Bind_File_Prefix.all'Length
1777 Fname_Len := Fname_Len - 1;
1782 Fnam : constant String :=
1783 Bind_File_Prefix.all &
1784 Fname (Fname'First .. Fname'First + Fname_Len - 1);
1787 Binder_Spec_Src_File := new String'(Fnam & ".ads
");
1788 Binder_Body_Src_File := new String'(Fnam & ".adb
");
1789 Binder_Ali_File := new String'(Fnam & ".ali
");
1791 Binder_Obj_File := new String'(Fnam & Get_Target_Object_Suffix.all);
1794 if Fname_Len /= Fname'Length then
1795 Binder_Options.Increment_Last;
1796 Binder_Options.Table (Binder_Options.Last) := new String'("-o
");
1797 Binder_Options.Increment_Last;
1798 Binder_Options.Table (Binder_Options.Last) := Binder_Obj_File;
1800 end Make_Binder_File_Names;
1802 Process_Binder_File (Binder_Body_Src_File.all & ASCII.NUL);
1804 -- Compile the binder file. This is fast, so we always do it, unless
1805 -- specifically told not to by the -n switch
1807 if Compile_Bind_File then
1811 Args : Argument_List
1812 (1 .. Binder_Options_From_ALI.Last + Binder_Options.Last + 1);
1815 for J in 1 .. Binder_Options_From_ALI.Last loop
1816 Args (J) := Binder_Options_From_ALI.Table (J);
1819 for J in 1 .. Binder_Options.Last loop
1820 Args (Binder_Options_From_ALI.Last + J) :=
1821 Binder_Options.Table (J);
1824 -- Use the full path of the binder generated source, so that it is
1825 -- guaranteed that the debugger will find this source, even with
1829 new String'(Normalize_Pathname (Binder_Body_Src_File.all));
1831 if Verbose_Mode then
1832 Write_Str (Base_Name (Gcc_Path.all));
1834 for J in Args'Range loop
1836 Write_Str (Args (J).all);
1842 System.OS_Lib.Spawn (Gcc_Path.all, Args, Success);
1845 Exit_Program (E_Fatal);
1850 -- In CodePeer mode, there's nothing left to do after the binder file has
1853 if Opt.CodePeer_Mode then
1854 if Tname_FD /= Invalid_FD then
1861 -- Now, actually link the program
1864 Num_Args : Natural :=
1865 (Linker_Options.Last - Linker_Options.First + 1) +
1866 (Gcc_Linker_Options.Last - Gcc_Linker_Options.First + 1) +
1867 (Linker_Objects.Last - Linker_Objects.First + 1);
1868 Stack_Op : Boolean := False;
1871 -- Remove duplicate stack size setting from the Linker_Options table.
1872 -- The stack setting option "-Xlinker
--stack=R,C" can be found
1873 -- in one line when set by a pragma Linker_Options or in two lines
1874 -- ("-Xlinker" then "--stack=R,C") when set on the command line. We
1875 -- also check for the "-Wl,--stack=R" style option.
1877 -- We must remove the second stack setting option instance because
1878 -- the one on the command line will always be the first one. And any
1879 -- subsequent stack setting option will overwrite the previous one.
1880 -- This is done especially for GNAT/NT where we set the stack size
1881 -- for tasking programs by a pragma in the NT specific tasking
1882 -- package System.Task_Primitives.Operations.
1884 -- Note: This is not a FOR loop that runs from Linker_Options.First
1885 -- to Linker_Options.Last, since operations within the loop can
1886 -- modify the length of the table.
1888 Clean_Link_Option_Set
: declare
1890 Shared_Libgcc_Seen
: Boolean := False;
1893 J
:= Linker_Options
.First
;
1894 while J
<= Linker_Options
.Last
loop
1895 if Linker_Options
.Table
(J
).all = "-Xlinker"
1896 and then J
< Linker_Options
.Last
1897 and then Linker_Options
.Table
(J
+ 1)'Length > 8
1898 and then Linker_Options
.Table
(J
+ 1) (1 .. 8) = "--stack="
1901 Linker_Options
.Table
(J
.. Linker_Options
.Last
- 2) :=
1902 Linker_Options
.Table
(J
+ 2 .. Linker_Options
.Last
);
1903 Linker_Options
.Decrement_Last
;
1904 Linker_Options
.Decrement_Last
;
1905 Num_Args
:= Num_Args
- 2;
1912 -- Remove duplicate -shared-libgcc switch
1914 if Linker_Options
.Table
(J
).all = Shared_Libgcc_String
then
1915 if Shared_Libgcc_Seen
then
1916 Linker_Options
.Table
(J
.. Linker_Options
.Last
- 1) :=
1917 Linker_Options
.Table
(J
+ 1 .. Linker_Options
.Last
);
1918 Linker_Options
.Decrement_Last
;
1919 Num_Args
:= Num_Args
- 1;
1922 Shared_Libgcc_Seen
:= True;
1926 -- Here we just check for a canonical form that matches the
1927 -- pragma Linker_Options set in the NT runtime.
1929 if (Linker_Options
.Table
(J
)'Length > 17
1930 and then Linker_Options
.Table
(J
) (1 .. 17) =
1931 "-Xlinker --stack=")
1933 (Linker_Options
.Table
(J
)'Length > 12
1934 and then Linker_Options
.Table
(J
) (1 .. 12) =
1938 Linker_Options
.Table
(J
.. Linker_Options
.Last
- 1) :=
1939 Linker_Options
.Table
(J
+ 1 .. Linker_Options
.Last
);
1940 Linker_Options
.Decrement_Last
;
1941 Num_Args
:= Num_Args
- 1;
1951 if Linker_Path
= Gcc_Path
then
1953 -- For systems where the default is to link statically with
1954 -- libgcc, if gcc is not called with -shared-libgcc, call it
1955 -- with -static-libgcc, as there are some platforms where one
1956 -- of these two switches is compulsory to link.
1958 if Shared_Libgcc_Default
= 'T'
1959 and then not Shared_Libgcc_Seen
1961 Linker_Options
.Increment_Last
;
1962 Linker_Options
.Table
(Linker_Options
.Last
) := Static_Libgcc
;
1963 Num_Args
:= Num_Args
+ 1;
1966 end Clean_Link_Option_Set
;
1968 -- Prepare arguments for call to linker
1970 Call_Linker
: declare
1972 Args
: Argument_List
(1 .. Num_Args
+ 1);
1973 Index
: Integer := Args
'First;
1976 Args
(Index
) := Binder_Obj_File
;
1978 -- Add the object files and any -largs libraries
1980 for J
in Linker_Objects
.First
.. Linker_Objects
.Last
loop
1982 Args
(Index
) := Linker_Objects
.Table
(J
);
1985 -- Add the linker options from the binder file
1987 for J
in Linker_Options
.First
.. Linker_Options
.Last
loop
1989 Args
(Index
) := Linker_Options
.Table
(J
);
1992 -- Finally add the libraries from the --GCC= switch
1994 for J
in Gcc_Linker_Options
.First
.. Gcc_Linker_Options
.Last
loop
1996 Args
(Index
) := Gcc_Linker_Options
.Table
(J
);
1999 if Verbose_Mode
then
2000 Write_Str
(Linker_Path
.all);
2002 for J
in Args
'Range loop
2004 Write_Str
(Args
(J
).all);
2009 -- If we are on very verbose mode (-v -v) and a response file
2010 -- is used we display its content.
2012 if Very_Verbose_Mode
and then Tname_FD
/= Invalid_FD
then
2014 Write_Str
("Response file (" &
2015 Tname
(Tname
'First .. Tname
'Last - 1) &
2020 Response_File_Objects
.First
.. Response_File_Objects
.Last
2022 Write_Str
(Response_File_Objects
.Table
(J
).all);
2030 System
.OS_Lib
.Spawn
(Linker_Path
.all, Args
, Success
);
2032 -- Delete the temporary file used in conjunction with linking if one
2033 -- was created. See Process_Bind_File for details.
2035 if Tname_FD
/= Invalid_FD
then
2040 Error_Msg
("error when calling " & Linker_Path
.all);
2041 Exit_Program
(E_Fatal
);
2046 -- Only keep the binder output file and it's associated object
2047 -- file if compiling with the -g option. These files are only
2048 -- useful if debugging.
2050 if not Debug_Flag_Present
then
2051 Delete
(Binder_Ali_File
.all & ASCII
.NUL
);
2052 Delete
(Binder_Spec_Src_File
.all & ASCII
.NUL
);
2053 Delete
(Binder_Body_Src_File
.all & ASCII
.NUL
);
2054 Delete
(Binder_Obj_File
.all & ASCII
.NUL
);
2057 Exit_Program
(E_Success
);
2061 Write_Line
(Exception_Information
(X
));
2062 Exit_With_Error
("INTERNAL ERROR. Please report");