isci: Convert SATA fis data structures to Linux native
[linux-2.6/x86.git] / drivers / scsi / isci / core / scic_phy.h
blob6fe39ccedf0b92d4843eef32b9793a9fea8069e4
1 /*
2 * This file is provided under a dual BSD/GPLv2 license. When using or
3 * redistributing this file, you may do so under either license.
5 * GPL LICENSE SUMMARY
7 * Copyright(c) 2008 - 2011 Intel Corporation. All rights reserved.
9 * This program is free software; you can redistribute it and/or modify
10 * it under the terms of version 2 of the GNU General Public License as
11 * published by the Free Software Foundation.
13 * This program is distributed in the hope that it will be useful, but
14 * WITHOUT ANY WARRANTY; without even the implied warranty of
15 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
16 * General Public License for more details.
18 * You should have received a copy of the GNU General Public License
19 * along with this program; if not, write to the Free Software
20 * Foundation, Inc., 51 Franklin St - Fifth Floor, Boston, MA 02110-1301 USA.
21 * The full GNU General Public License is included in this distribution
22 * in the file called LICENSE.GPL.
24 * BSD LICENSE
26 * Copyright(c) 2008 - 2011 Intel Corporation. All rights reserved.
27 * All rights reserved.
29 * Redistribution and use in source and binary forms, with or without
30 * modification, are permitted provided that the following conditions
31 * are met:
33 * * Redistributions of source code must retain the above copyright
34 * notice, this list of conditions and the following disclaimer.
35 * * Redistributions in binary form must reproduce the above copyright
36 * notice, this list of conditions and the following disclaimer in
37 * the documentation and/or other materials provided with the
38 * distribution.
39 * * Neither the name of Intel Corporation nor the names of its
40 * contributors may be used to endorse or promote products derived
41 * from this software without specific prior written permission.
43 * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
44 * "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
45 * LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
46 * A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
47 * OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
48 * SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
49 * LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
50 * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
51 * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
52 * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
53 * OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
56 #ifndef _SCIC_PHY_H_
57 #define _SCIC_PHY_H_
59 /**
60 * This file contains all of the interface methods that can be called by an
61 * SCIC user on a phy (SAS or SATA) object.
67 #include <scsi/sas.h>
68 #include <scsi/libsas.h>
69 #include "sci_status.h"
70 #include "intel_sata.h"
71 #include "intel_sas.h"
73 struct scic_sds_phy;
74 struct scic_sds_port;
77 enum sas_linkrate sci_phy_linkrate(struct scic_sds_phy *sci_phy);
79 /**
80 * struct scic_phy_properties - This structure defines the properties common to
81 * all phys that can be retrieved.
85 struct scic_phy_properties {
86 /**
87 * This field specifies the port that currently contains the
88 * supplied phy. This field may be set to NULL
89 * if the phy is not currently contained in a port.
91 struct scic_sds_port *owning_port;
93 /**
94 * This field specifies the link rate at which the phy is
95 * currently operating.
97 enum sas_linkrate negotiated_link_rate;
99 /**
100 * This field indicates the protocols supported by the phy.
102 struct sci_sas_identify_address_frame_protocols protocols;
105 * This field specifies the index of the phy in relation to other
106 * phys within the controller. This index is zero relative.
108 u8 index;
113 * struct scic_sas_phy_properties - This structure defines the properties,
114 * specific to a SAS phy, that can be retrieved.
118 struct scic_sas_phy_properties {
120 * This field delineates the Identify Address Frame received
121 * from the remote end point.
123 struct sci_sas_identify_address_frame received_iaf;
126 * This field delineates the Phy capabilities structure received
127 * from the remote end point.
129 struct sas_capabilities received_capabilities;
134 * struct scic_sata_phy_properties - This structure defines the properties,
135 * specific to a SATA phy, that can be retrieved.
139 struct scic_sata_phy_properties {
141 * This field delineates the signature FIS received from the
142 * attached target.
144 struct dev_to_host_fis signature_fis;
147 * This field specifies to the user if a port selector is connected
148 * on the specified phy.
150 bool is_port_selector_present;
155 * enum scic_phy_counter_id - This enumeration depicts the various pieces of
156 * optional information that can be retrieved for a specific phy.
160 enum scic_phy_counter_id {
162 * This PHY information field tracks the number of frames received.
164 SCIC_PHY_COUNTER_RECEIVED_FRAME,
167 * This PHY information field tracks the number of frames transmitted.
169 SCIC_PHY_COUNTER_TRANSMITTED_FRAME,
172 * This PHY information field tracks the number of DWORDs received.
174 SCIC_PHY_COUNTER_RECEIVED_FRAME_WORD,
177 * This PHY information field tracks the number of DWORDs transmitted.
179 SCIC_PHY_COUNTER_TRANSMITTED_FRAME_DWORD,
182 * This PHY information field tracks the number of times DWORD
183 * synchronization was lost.
185 SCIC_PHY_COUNTER_LOSS_OF_SYNC_ERROR,
188 * This PHY information field tracks the number of received DWORDs with
189 * running disparity errors.
191 SCIC_PHY_COUNTER_RECEIVED_DISPARITY_ERROR,
194 * This PHY information field tracks the number of received frames with a
195 * CRC error (not including short or truncated frames).
197 SCIC_PHY_COUNTER_RECEIVED_FRAME_CRC_ERROR,
200 * This PHY information field tracks the number of DONE (ACK/NAK TIMEOUT)
201 * primitives received.
203 SCIC_PHY_COUNTER_RECEIVED_DONE_ACK_NAK_TIMEOUT,
206 * This PHY information field tracks the number of DONE (ACK/NAK TIMEOUT)
207 * primitives transmitted.
209 SCIC_PHY_COUNTER_TRANSMITTED_DONE_ACK_NAK_TIMEOUT,
212 * This PHY information field tracks the number of times the inactivity
213 * timer for connections on the phy has been utilized.
215 SCIC_PHY_COUNTER_INACTIVITY_TIMER_EXPIRED,
218 * This PHY information field tracks the number of DONE (CREDIT TIMEOUT)
219 * primitives received.
221 SCIC_PHY_COUNTER_RECEIVED_DONE_CREDIT_TIMEOUT,
224 * This PHY information field tracks the number of DONE (CREDIT TIMEOUT)
225 * primitives transmitted.
227 SCIC_PHY_COUNTER_TRANSMITTED_DONE_CREDIT_TIMEOUT,
230 * This PHY information field tracks the number of CREDIT BLOCKED
231 * primitives received.
232 * @note Depending on remote device implementation, credit blocks
233 * may occur regularly.
235 SCIC_PHY_COUNTER_RECEIVED_CREDIT_BLOCKED,
238 * This PHY information field contains the number of short frames
239 * received. A short frame is simply a frame smaller then what is
240 * allowed by either the SAS or SATA specification.
242 SCIC_PHY_COUNTER_RECEIVED_SHORT_FRAME,
245 * This PHY information field contains the number of frames received after
246 * credit has been exhausted.
248 SCIC_PHY_COUNTER_RECEIVED_FRAME_WITHOUT_CREDIT,
251 * This PHY information field contains the number of frames received after
252 * a DONE has been received.
254 SCIC_PHY_COUNTER_RECEIVED_FRAME_AFTER_DONE,
257 * This PHY information field contains the number of times the phy
258 * failed to achieve DWORD synchronization during speed negotiation.
260 SCIC_PHY_COUNTER_SN_DWORD_SYNC_ERROR
265 * scic_sas_phy_get_properties() - This method will enable the user to retrieve
266 * information specific to a SAS phy, such as: the received identify address
267 * frame, received phy capabilities, etc.
268 * @phy: this parameter specifies the phy for which to retrieve properties.
269 * @properties: This parameter specifies the properties structure into which to
270 * copy the requested information.
272 * This method returns an indication as to whether the SAS phy properties were
273 * successfully retrieved. SCI_SUCCESS This value is returned if the SAS
274 * properties are successfully retrieved. SCI_FAILURE This value is returned if
275 * the SAS properties are not successfully retrieved (e.g. It's not a SAS Phy).
277 enum sci_status scic_sas_phy_get_properties(
278 struct scic_sds_phy *phy,
279 struct scic_sas_phy_properties *properties);
282 * scic_sata_phy_get_properties() - This method will enable the user to
283 * retrieve information specific to a SATA phy, such as: the received
284 * signature FIS, if a port selector is present, etc.
285 * @phy: this parameter specifies the phy for which to retrieve properties.
286 * @properties: This parameter specifies the properties structure into which to
287 * copy the requested information.
289 * This method returns an indication as to whether the SATA phy properties were
290 * successfully retrieved. SCI_SUCCESS This value is returned if the SATA
291 * properties are successfully retrieved. SCI_FAILURE This value is returned if
292 * the SATA properties are not successfully retrieved (e.g. It's not a SATA
293 * Phy).
295 enum sci_status scic_sata_phy_get_properties(
296 struct scic_sds_phy *phy,
297 struct scic_sata_phy_properties *properties);
305 #endif /* _SCIC_PHY_H_ */