[SCSI] libfc: do not change the fh_rx_id of a recevied frame
[linux-2.6/mini2440.git] / Documentation / i2c / smbus-protocol
blob9df47441f0e73063c39f39fe22acc1fb3a753416
1 SMBus Protocol Summary
2 ======================
4 The following is a summary of the SMBus protocol. It applies to
5 all revisions of the protocol (1.0, 1.1, and 2.0).
6 Certain protocol features which are not supported by
7 this package are briefly described at the end of this document.
9 Some adapters understand only the SMBus (System Management Bus) protocol,
10 which is a subset from the I2C protocol. Fortunately, many devices use
11 only the same subset, which makes it possible to put them on an SMBus.
13 If you write a driver for some I2C device, please try to use the SMBus
14 commands if at all possible (if the device uses only that subset of the
15 I2C protocol). This makes it possible to use the device driver on both
16 SMBus adapters and I2C adapters (the SMBus command set is automatically
17 translated to I2C on I2C adapters, but plain I2C commands can not be
18 handled at all on most pure SMBus adapters).
20 Below is a list of SMBus protocol operations, and the functions executing
21 them.  Note that the names used in the SMBus protocol specifications usually
22 don't match these function names.  For some of the operations which pass a
23 single data byte, the functions using SMBus protocol operation names execute
24 a different protocol operation entirely.
27 Key to symbols
28 ==============
30 S     (1 bit) : Start bit
31 P     (1 bit) : Stop bit
32 Rd/Wr (1 bit) : Read/Write bit. Rd equals 1, Wr equals 0.
33 A, NA (1 bit) : Accept and reverse accept bit. 
34 Addr  (7 bits): I2C 7 bit address. Note that this can be expanded as usual to 
35                 get a 10 bit I2C address.
36 Comm  (8 bits): Command byte, a data byte which often selects a register on
37                 the device.
38 Data  (8 bits): A plain data byte. Sometimes, I write DataLow, DataHigh
39                 for 16 bit data.
40 Count (8 bits): A data byte containing the length of a block operation.
42 [..]: Data sent by I2C device, as opposed to data sent by the host adapter.
45 SMBus Quick Command
46 ===================
48 This sends a single bit to the device, at the place of the Rd/Wr bit.
50 A Addr Rd/Wr [A] P
53 SMBus Receive Byte:  i2c_smbus_read_byte()
54 ==========================================
56 This reads a single byte from a device, without specifying a device
57 register. Some devices are so simple that this interface is enough; for
58 others, it is a shorthand if you want to read the same register as in
59 the previous SMBus command.
61 S Addr Rd [A] [Data] NA P
64 SMBus Send Byte:  i2c_smbus_write_byte()
65 ========================================
67 This operation is the reverse of Receive Byte: it sends a single byte
68 to a device.  See Receive Byte for more information.
70 S Addr Wr [A] Data [A] P
73 SMBus Read Byte:  i2c_smbus_read_byte_data()
74 ============================================
76 This reads a single byte from a device, from a designated register.
77 The register is specified through the Comm byte.
79 S Addr Wr [A] Comm [A] S Addr Rd [A] [Data] NA P
82 SMBus Read Word:  i2c_smbus_read_word_data()
83 ============================================
85 This operation is very like Read Byte; again, data is read from a
86 device, from a designated register that is specified through the Comm
87 byte. But this time, the data is a complete word (16 bits).
89 S Addr Wr [A] Comm [A] S Addr Rd [A] [DataLow] A [DataHigh] NA P
92 SMBus Write Byte:  i2c_smbus_write_byte_data()
93 ==============================================
95 This writes a single byte to a device, to a designated register. The
96 register is specified through the Comm byte. This is the opposite of
97 the Read Byte operation.
99 S Addr Wr [A] Comm [A] Data [A] P
102 SMBus Write Word:  i2c_smbus_write_word_data()
103 ==============================================
105 This is the opposite of the Read Word operation. 16 bits
106 of data is written to a device, to the designated register that is
107 specified through the Comm byte. 
109 S Addr Wr [A] Comm [A] DataLow [A] DataHigh [A] P
112 SMBus Process Call:  i2c_smbus_process_call()
113 =============================================
115 This command selects a device register (through the Comm byte), sends
116 16 bits of data to it, and reads 16 bits of data in return.
118 S Addr Wr [A] Comm [A] DataLow [A] DataHigh [A] 
119                              S Addr Rd [A] [DataLow] A [DataHigh] NA P
122 SMBus Block Read:  i2c_smbus_read_block_data()
123 ==============================================
125 This command reads a block of up to 32 bytes from a device, from a 
126 designated register that is specified through the Comm byte. The amount
127 of data is specified by the device in the Count byte.
129 S Addr Wr [A] Comm [A] 
130            S Addr Rd [A] [Count] A [Data] A [Data] A ... A [Data] NA P
133 SMBus Block Write:  i2c_smbus_write_block_data()
134 ================================================
136 The opposite of the Block Read command, this writes up to 32 bytes to 
137 a device, to a designated register that is specified through the
138 Comm byte. The amount of data is specified in the Count byte.
140 S Addr Wr [A] Comm [A] Count [A] Data [A] Data [A] ... [A] Data [A] P
143 SMBus Block Write - Block Read Process Call
144 ===========================================
146 SMBus Block Write - Block Read Process Call was introduced in
147 Revision 2.0 of the specification.
149 This command selects a device register (through the Comm byte), sends
150 1 to 31 bytes of data to it, and reads 1 to 31 bytes of data in return.
152 S Addr Wr [A] Comm [A] Count [A] Data [A] ...
153                              S Addr Rd [A] [Count] A [Data] ... A P
156 SMBus Host Notify
157 =================
159 This command is sent from a SMBus device acting as a master to the
160 SMBus host acting as a slave.
161 It is the same form as Write Word, with the command code replaced by the
162 alerting device's address.
164 [S] [HostAddr] [Wr] A [DevAddr] A [DataLow] A [DataHigh] A [P]
167 Packet Error Checking (PEC)
168 ===========================
170 Packet Error Checking was introduced in Revision 1.1 of the specification.
172 PEC adds a CRC-8 error-checking byte to transfers using it, immediately
173 before the terminating STOP.
176 Address Resolution Protocol (ARP)
177 =================================
179 The Address Resolution Protocol was introduced in Revision 2.0 of
180 the specification. It is a higher-layer protocol which uses the
181 messages above.
183 ARP adds device enumeration and dynamic address assignment to
184 the protocol. All ARP communications use slave address 0x61 and
185 require PEC checksums.
188 I2C Block Transactions
189 ======================
191 The following I2C block transactions are supported by the
192 SMBus layer and are described here for completeness.
193 They are *NOT* defined by the SMBus specification.
195 I2C block transactions do not limit the number of bytes transferred
196 but the SMBus layer places a limit of 32 bytes.
199 I2C Block Read:  i2c_smbus_read_i2c_block_data()
200 ================================================
202 This command reads a block of bytes from a device, from a 
203 designated register that is specified through the Comm byte.
205 S Addr Wr [A] Comm [A] 
206            S Addr Rd [A] [Data] A [Data] A ... A [Data] NA P
209 I2C Block Read (2 Comm bytes)
210 =============================
212 This command reads a block of bytes from a device, from a 
213 designated register that is specified through the two Comm bytes.
215 S Addr Wr [A] Comm1 [A] Comm2 [A] 
216            S Addr Rd [A] [Data] A [Data] A ... A [Data] NA P
219 I2C Block Write:  i2c_smbus_write_i2c_block_data()
220 ==================================================
222 The opposite of the Block Read command, this writes bytes to 
223 a device, to a designated register that is specified through the
224 Comm byte. Note that command lengths of 0, 2, or more bytes are
225 supported as they are indistinguishable from data.
227 S Addr Wr [A] Comm [A] Data [A] Data [A] ... [A] Data [A] P