powerpc: Add new CPU feature: CPU_FTR_CP_USE_DCBTZ
[linux-2.6/mini2440.git] / drivers / md / Kconfig
blob07d92c11b5d8d935887f0b8361626faaf1abfd46
2 # Block device driver configuration
5 menuconfig MD
6         bool "Multiple devices driver support (RAID and LVM)"
7         depends on BLOCK
8         help
9           Support multiple physical spindles through a single logical device.
10           Required for RAID and logical volume management.
12 if MD
14 config BLK_DEV_MD
15         tristate "RAID support"
16         ---help---
17           This driver lets you combine several hard disk partitions into one
18           logical block device. This can be used to simply append one
19           partition to another one or to combine several redundant hard disks
20           into a RAID1/4/5 device so as to provide protection against hard
21           disk failures. This is called "Software RAID" since the combining of
22           the partitions is done by the kernel. "Hardware RAID" means that the
23           combining is done by a dedicated controller; if you have such a
24           controller, you do not need to say Y here.
26           More information about Software RAID on Linux is contained in the
27           Software RAID mini-HOWTO, available from
28           <http://www.tldp.org/docs.html#howto>. There you will also learn
29           where to get the supporting user space utilities raidtools.
31           If unsure, say N.
33 config MD_LINEAR
34         tristate "Linear (append) mode"
35         depends on BLK_DEV_MD
36         ---help---
37           If you say Y here, then your multiple devices driver will be able to
38           use the so-called linear mode, i.e. it will combine the hard disk
39           partitions by simply appending one to the other.
41           To compile this as a module, choose M here: the module
42           will be called linear.
44           If unsure, say Y.
46 config MD_RAID0
47         tristate "RAID-0 (striping) mode"
48         depends on BLK_DEV_MD
49         ---help---
50           If you say Y here, then your multiple devices driver will be able to
51           use the so-called raid0 mode, i.e. it will combine the hard disk
52           partitions into one logical device in such a fashion as to fill them
53           up evenly, one chunk here and one chunk there. This will increase
54           the throughput rate if the partitions reside on distinct disks.
56           Information about Software RAID on Linux is contained in the
57           Software-RAID mini-HOWTO, available from
58           <http://www.tldp.org/docs.html#howto>. There you will also
59           learn where to get the supporting user space utilities raidtools.
61           To compile this as a module, choose M here: the module
62           will be called raid0.
64           If unsure, say Y.
66 config MD_RAID1
67         tristate "RAID-1 (mirroring) mode"
68         depends on BLK_DEV_MD
69         ---help---
70           A RAID-1 set consists of several disk drives which are exact copies
71           of each other.  In the event of a mirror failure, the RAID driver
72           will continue to use the operational mirrors in the set, providing
73           an error free MD (multiple device) to the higher levels of the
74           kernel.  In a set with N drives, the available space is the capacity
75           of a single drive, and the set protects against a failure of (N - 1)
76           drives.
78           Information about Software RAID on Linux is contained in the
79           Software-RAID mini-HOWTO, available from
80           <http://www.tldp.org/docs.html#howto>.  There you will also
81           learn where to get the supporting user space utilities raidtools.
83           If you want to use such a RAID-1 set, say Y.  To compile this code
84           as a module, choose M here: the module will be called raid1.
86           If unsure, say Y.
88 config MD_RAID10
89         tristate "RAID-10 (mirrored striping) mode (EXPERIMENTAL)"
90         depends on BLK_DEV_MD && EXPERIMENTAL
91         ---help---
92           RAID-10 provides a combination of striping (RAID-0) and
93           mirroring (RAID-1) with easier configuration and more flexible
94           layout.
95           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
96           be the same size (or at least, only as much as the smallest device
97           will be used).
98           RAID-10 provides a variety of layouts that provide different levels
99           of redundancy and performance.
101           RAID-10 requires mdadm-1.7.0 or later, available at:
103           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
105           If unsure, say Y.
107 config MD_RAID456
108         tristate "RAID-4/RAID-5/RAID-6 mode"
109         depends on BLK_DEV_MD
110         select ASYNC_MEMCPY
111         select ASYNC_XOR
112         ---help---
113           A RAID-5 set of N drives with a capacity of C MB per drive provides
114           the capacity of C * (N - 1) MB, and protects against a failure
115           of a single drive. For a given sector (row) number, (N - 1) drives
116           contain data sectors, and one drive contains the parity protection.
117           For a RAID-4 set, the parity blocks are present on a single drive,
118           while a RAID-5 set distributes the parity across the drives in one
119           of the available parity distribution methods.
121           A RAID-6 set of N drives with a capacity of C MB per drive
122           provides the capacity of C * (N - 2) MB, and protects
123           against a failure of any two drives. For a given sector
124           (row) number, (N - 2) drives contain data sectors, and two
125           drives contains two independent redundancy syndromes.  Like
126           RAID-5, RAID-6 distributes the syndromes across the drives
127           in one of the available parity distribution methods.
129           Information about Software RAID on Linux is contained in the
130           Software-RAID mini-HOWTO, available from
131           <http://www.tldp.org/docs.html#howto>. There you will also
132           learn where to get the supporting user space utilities raidtools.
134           If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
135           compile this code as a module, choose M here: the module
136           will be called raid456.
138           If unsure, say Y.
140 config MD_RAID5_RESHAPE
141         bool "Support adding drives to a raid-5 array"
142         depends on MD_RAID456
143         default y
144         ---help---
145           A RAID-5 set can be expanded by adding extra drives. This
146           requires "restriping" the array which means (almost) every
147           block must be written to a different place.
149           This option allows such restriping to be done while the array
150           is online.
152           You will need mdadm version 2.4.1 or later to use this
153           feature safely.  During the early stage of reshape there is
154           a critical section where live data is being over-written.  A
155           crash during this time needs extra care for recovery.  The
156           newer mdadm takes a copy of the data in the critical section
157           and will restore it, if necessary, after a crash.
159           The mdadm usage is e.g.
160                mdadm --grow /dev/md1 --raid-disks=6
161           to grow '/dev/md1' to having 6 disks.
163           Note: The array can only be expanded, not contracted.
164           There should be enough spares already present to make the new
165           array workable.
167           If unsure, say Y.
169 config MD_MULTIPATH
170         tristate "Multipath I/O support"
171         depends on BLK_DEV_MD
172         help
173           Multipath-IO is the ability of certain devices to address the same
174           physical disk over multiple 'IO paths'. The code ensures that such
175           paths can be defined and handled at runtime, and ensures that a
176           transparent failover to the backup path(s) happens if a IO errors
177           arrives on the primary path.
179           If unsure, say N.
181 config MD_FAULTY
182         tristate "Faulty test module for MD"
183         depends on BLK_DEV_MD
184         help
185           The "faulty" module allows for a block device that occasionally returns
186           read or write errors.  It is useful for testing.
188           In unsure, say N.
190 config BLK_DEV_DM
191         tristate "Device mapper support"
192         ---help---
193           Device-mapper is a low level volume manager.  It works by allowing
194           people to specify mappings for ranges of logical sectors.  Various
195           mapping types are available, in addition people may write their own
196           modules containing custom mappings if they wish.
198           Higher level volume managers such as LVM2 use this driver.
200           To compile this as a module, choose M here: the module will be
201           called dm-mod.
203           If unsure, say N.
205 config DM_DEBUG
206         boolean "Device mapper debugging support"
207         depends on BLK_DEV_DM
208         ---help---
209           Enable this for messages that may help debug device-mapper problems.
211           If unsure, say N.
213 config DM_CRYPT
214         tristate "Crypt target support"
215         depends on BLK_DEV_DM
216         select CRYPTO
217         select CRYPTO_CBC
218         ---help---
219           This device-mapper target allows you to create a device that
220           transparently encrypts the data on it. You'll need to activate
221           the ciphers you're going to use in the cryptoapi configuration.
223           Information on how to use dm-crypt can be found on
225           <http://www.saout.de/misc/dm-crypt/>
227           To compile this code as a module, choose M here: the module will
228           be called dm-crypt.
230           If unsure, say N.
232 config DM_SNAPSHOT
233        tristate "Snapshot target"
234        depends on BLK_DEV_DM
235        ---help---
236          Allow volume managers to take writable snapshots of a device.
238 config DM_MIRROR
239        tristate "Mirror target"
240        depends on BLK_DEV_DM
241        ---help---
242          Allow volume managers to mirror logical volumes, also
243          needed for live data migration tools such as 'pvmove'.
245 config DM_ZERO
246         tristate "Zero target"
247         depends on BLK_DEV_DM
248         ---help---
249           A target that discards writes, and returns all zeroes for
250           reads.  Useful in some recovery situations.
252 config DM_MULTIPATH
253         tristate "Multipath target"
254         depends on BLK_DEV_DM
255         # nasty syntax but means make DM_MULTIPATH independent
256         # of SCSI_DH if the latter isn't defined but if
257         # it is, DM_MULTIPATH must depend on it.  We get a build
258         # error if SCSI_DH=m and DM_MULTIPATH=y
259         depends on SCSI_DH || !SCSI_DH
260         ---help---
261           Allow volume managers to support multipath hardware.
263 config DM_DELAY
264         tristate "I/O delaying target (EXPERIMENTAL)"
265         depends on BLK_DEV_DM && EXPERIMENTAL
266         ---help---
267         A target that delays reads and/or writes and can send
268         them to different devices.  Useful for testing.
270         If unsure, say N.
272 config DM_UEVENT
273         bool "DM uevents (EXPERIMENTAL)"
274         depends on BLK_DEV_DM && EXPERIMENTAL
275         ---help---
276         Generate udev events for DM events.
278 endif # MD