2 # Block device driver configuration
6 bool "Multiple devices driver support (RAID and LVM)"
9 Support multiple physical spindles through a single logical device.
10 Required for RAID and logical volume management.
15 tristate "RAID support"
17 This driver lets you combine several hard disk partitions into one
18 logical block device. This can be used to simply append one
19 partition to another one or to combine several redundant hard disks
20 into a RAID1/4/5 device so as to provide protection against hard
21 disk failures. This is called "Software RAID" since the combining of
22 the partitions is done by the kernel. "Hardware RAID" means that the
23 combining is done by a dedicated controller; if you have such a
24 controller, you do not need to say Y here.
26 More information about Software RAID on Linux is contained in the
27 Software RAID mini-HOWTO, available from
28 <http://www.tldp.org/docs.html#howto>. There you will also learn
29 where to get the supporting user space utilities raidtools.
34 bool "Autodetect RAID arrays during kernel boot"
35 depends on BLK_DEV_MD=y
38 If you say Y here, then the kernel will try to autodetect raid
39 arrays as part of its boot process.
41 If you don't use raid and say Y, this autodetection can cause
42 a several-second delay in the boot time due to various
43 synchronisation steps that are part of this step.
48 tristate "Linear (append) mode"
51 If you say Y here, then your multiple devices driver will be able to
52 use the so-called linear mode, i.e. it will combine the hard disk
53 partitions by simply appending one to the other.
55 To compile this as a module, choose M here: the module
56 will be called linear.
61 tristate "RAID-0 (striping) mode"
64 If you say Y here, then your multiple devices driver will be able to
65 use the so-called raid0 mode, i.e. it will combine the hard disk
66 partitions into one logical device in such a fashion as to fill them
67 up evenly, one chunk here and one chunk there. This will increase
68 the throughput rate if the partitions reside on distinct disks.
70 Information about Software RAID on Linux is contained in the
71 Software-RAID mini-HOWTO, available from
72 <http://www.tldp.org/docs.html#howto>. There you will also
73 learn where to get the supporting user space utilities raidtools.
75 To compile this as a module, choose M here: the module
81 tristate "RAID-1 (mirroring) mode"
84 A RAID-1 set consists of several disk drives which are exact copies
85 of each other. In the event of a mirror failure, the RAID driver
86 will continue to use the operational mirrors in the set, providing
87 an error free MD (multiple device) to the higher levels of the
88 kernel. In a set with N drives, the available space is the capacity
89 of a single drive, and the set protects against a failure of (N - 1)
92 Information about Software RAID on Linux is contained in the
93 Software-RAID mini-HOWTO, available from
94 <http://www.tldp.org/docs.html#howto>. There you will also
95 learn where to get the supporting user space utilities raidtools.
97 If you want to use such a RAID-1 set, say Y. To compile this code
98 as a module, choose M here: the module will be called raid1.
103 tristate "RAID-10 (mirrored striping) mode"
104 depends on BLK_DEV_MD
106 RAID-10 provides a combination of striping (RAID-0) and
107 mirroring (RAID-1) with easier configuration and more flexible
109 Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110 be the same size (or at least, only as much as the smallest device
112 RAID-10 provides a variety of layouts that provide different levels
113 of redundancy and performance.
115 RAID-10 requires mdadm-1.7.0 or later, available at:
117 ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
122 tristate "RAID-4/RAID-5/RAID-6 mode"
123 depends on BLK_DEV_MD
128 select ASYNC_RAID6_RECOV
130 A RAID-5 set of N drives with a capacity of C MB per drive provides
131 the capacity of C * (N - 1) MB, and protects against a failure
132 of a single drive. For a given sector (row) number, (N - 1) drives
133 contain data sectors, and one drive contains the parity protection.
134 For a RAID-4 set, the parity blocks are present on a single drive,
135 while a RAID-5 set distributes the parity across the drives in one
136 of the available parity distribution methods.
138 A RAID-6 set of N drives with a capacity of C MB per drive
139 provides the capacity of C * (N - 2) MB, and protects
140 against a failure of any two drives. For a given sector
141 (row) number, (N - 2) drives contain data sectors, and two
142 drives contains two independent redundancy syndromes. Like
143 RAID-5, RAID-6 distributes the syndromes across the drives
144 in one of the available parity distribution methods.
146 Information about Software RAID on Linux is contained in the
147 Software-RAID mini-HOWTO, available from
148 <http://www.tldp.org/docs.html#howto>. There you will also
149 learn where to get the supporting user space utilities raidtools.
151 If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
152 compile this code as a module, choose M here: the module
153 will be called raid456.
157 config MULTICORE_RAID456
158 bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)"
159 depends on MD_RAID456
161 depends on EXPERIMENTAL
163 Enable the raid456 module to dispatch per-stripe raid operations to a
169 tristate "Multipath I/O support"
170 depends on BLK_DEV_MD
172 MD_MULTIPATH provides a simple multi-path personality for use
173 the MD framework. It is not under active development. New
174 projects should consider using DM_MULTIPATH which has more
175 features and more testing.
180 tristate "Faulty test module for MD"
181 depends on BLK_DEV_MD
183 The "faulty" module allows for a block device that occasionally returns
184 read or write errors. It is useful for testing.
189 tristate "Device mapper support"
191 Device-mapper is a low level volume manager. It works by allowing
192 people to specify mappings for ranges of logical sectors. Various
193 mapping types are available, in addition people may write their own
194 modules containing custom mappings if they wish.
196 Higher level volume managers such as LVM2 use this driver.
198 To compile this as a module, choose M here: the module will be
204 boolean "Device mapper debugging support"
205 depends on BLK_DEV_DM
207 Enable this for messages that may help debug device-mapper problems.
212 tristate "Crypt target support"
213 depends on BLK_DEV_DM
217 This device-mapper target allows you to create a device that
218 transparently encrypts the data on it. You'll need to activate
219 the ciphers you're going to use in the cryptoapi configuration.
221 Information on how to use dm-crypt can be found on
223 <http://www.saout.de/misc/dm-crypt/>
225 To compile this code as a module, choose M here: the module will
231 tristate "Snapshot target"
232 depends on BLK_DEV_DM
234 Allow volume managers to take writable snapshots of a device.
237 tristate "Mirror target"
238 depends on BLK_DEV_DM
240 Allow volume managers to mirror logical volumes, also
241 needed for live data migration tools such as 'pvmove'.
244 tristate "RAID 1/4/5/6 target (EXPERIMENTAL)"
245 depends on BLK_DEV_DM && EXPERIMENTAL
250 A dm target that supports RAID1, RAID4, RAID5 and RAID6 mappings
252 A RAID-5 set of N drives with a capacity of C MB per drive provides
253 the capacity of C * (N - 1) MB, and protects against a failure
254 of a single drive. For a given sector (row) number, (N - 1) drives
255 contain data sectors, and one drive contains the parity protection.
256 For a RAID-4 set, the parity blocks are present on a single drive,
257 while a RAID-5 set distributes the parity across the drives in one
258 of the available parity distribution methods.
260 A RAID-6 set of N drives with a capacity of C MB per drive
261 provides the capacity of C * (N - 2) MB, and protects
262 against a failure of any two drives. For a given sector
263 (row) number, (N - 2) drives contain data sectors, and two
264 drives contains two independent redundancy syndromes. Like
265 RAID-5, RAID-6 distributes the syndromes across the drives
266 in one of the available parity distribution methods.
268 config DM_LOG_USERSPACE
269 tristate "Mirror userspace logging (EXPERIMENTAL)"
270 depends on DM_MIRROR && EXPERIMENTAL && NET
273 The userspace logging module provides a mechanism for
274 relaying the dm-dirty-log API to userspace. Log designs
275 which are more suited to userspace implementation (e.g.
276 shared storage logs) or experimental logs can be implemented
277 by leveraging this framework.
280 tristate "Zero target"
281 depends on BLK_DEV_DM
283 A target that discards writes, and returns all zeroes for
284 reads. Useful in some recovery situations.
287 tristate "Multipath target"
288 depends on BLK_DEV_DM
289 # nasty syntax but means make DM_MULTIPATH independent
290 # of SCSI_DH if the latter isn't defined but if
291 # it is, DM_MULTIPATH must depend on it. We get a build
292 # error if SCSI_DH=m and DM_MULTIPATH=y
293 depends on SCSI_DH || !SCSI_DH
295 Allow volume managers to support multipath hardware.
297 config DM_MULTIPATH_QL
298 tristate "I/O Path Selector based on the number of in-flight I/Os"
299 depends on DM_MULTIPATH
301 This path selector is a dynamic load balancer which selects
302 the path with the least number of in-flight I/Os.
306 config DM_MULTIPATH_ST
307 tristate "I/O Path Selector based on the service time"
308 depends on DM_MULTIPATH
310 This path selector is a dynamic load balancer which selects
311 the path expected to complete the incoming I/O in the shortest
317 tristate "I/O delaying target (EXPERIMENTAL)"
318 depends on BLK_DEV_DM && EXPERIMENTAL
320 A target that delays reads and/or writes and can send
321 them to different devices. Useful for testing.
326 bool "DM uevents (EXPERIMENTAL)"
327 depends on BLK_DEV_DM && EXPERIMENTAL
329 Generate udev events for DM events.
332 tristate "Flakey target (EXPERIMENTAL)"
333 depends on BLK_DEV_DM && EXPERIMENTAL
335 A target that intermittently fails I/O for debugging purposes.