vlan: Rename VLAN_GROUP_ARRAY_LEN to VLAN_N_VID.
[linux-2.6/linux-acpi-2.6/ibm-acpi-2.6.git] / include / linux / cciss_defs.h
blob316b670d4e3354d7af46e7a7697ac16062306bcd
1 #ifndef CCISS_DEFS_H
2 #define CCISS_DEFS_H
4 #include <linux/types.h>
6 /* general boundary definitions */
7 #define SENSEINFOBYTES 32 /* note that this value may vary
8 between host implementations */
10 /* Command Status value */
11 #define CMD_SUCCESS 0x0000
12 #define CMD_TARGET_STATUS 0x0001
13 #define CMD_DATA_UNDERRUN 0x0002
14 #define CMD_DATA_OVERRUN 0x0003
15 #define CMD_INVALID 0x0004
16 #define CMD_PROTOCOL_ERR 0x0005
17 #define CMD_HARDWARE_ERR 0x0006
18 #define CMD_CONNECTION_LOST 0x0007
19 #define CMD_ABORTED 0x0008
20 #define CMD_ABORT_FAILED 0x0009
21 #define CMD_UNSOLICITED_ABORT 0x000A
22 #define CMD_TIMEOUT 0x000B
23 #define CMD_UNABORTABLE 0x000C
25 /* transfer direction */
26 #define XFER_NONE 0x00
27 #define XFER_WRITE 0x01
28 #define XFER_READ 0x02
29 #define XFER_RSVD 0x03
31 /* task attribute */
32 #define ATTR_UNTAGGED 0x00
33 #define ATTR_SIMPLE 0x04
34 #define ATTR_HEADOFQUEUE 0x05
35 #define ATTR_ORDERED 0x06
36 #define ATTR_ACA 0x07
38 /* cdb type */
39 #define TYPE_CMD 0x00
40 #define TYPE_MSG 0x01
42 /* Type defs used in the following structs */
43 #define BYTE __u8
44 #define WORD __u16
45 #define HWORD __u16
46 #define DWORD __u32
48 #define CISS_MAX_LUN 1024
50 #define LEVEL2LUN 1 /* index into Target(x) structure, due to byte swapping */
51 #define LEVEL3LUN 0
53 #pragma pack(1)
55 /* Command List Structure */
56 typedef union _SCSI3Addr_struct {
57 struct {
58 BYTE Dev;
59 BYTE Bus:6;
60 BYTE Mode:2; /* b00 */
61 } PeripDev;
62 struct {
63 BYTE DevLSB;
64 BYTE DevMSB:6;
65 BYTE Mode:2; /* b01 */
66 } LogDev;
67 struct {
68 BYTE Dev:5;
69 BYTE Bus:3;
70 BYTE Targ:6;
71 BYTE Mode:2; /* b10 */
72 } LogUnit;
73 } SCSI3Addr_struct;
75 typedef struct _PhysDevAddr_struct {
76 DWORD TargetId:24;
77 DWORD Bus:6;
78 DWORD Mode:2;
79 SCSI3Addr_struct Target[2]; /* 2 level target device addr */
80 } PhysDevAddr_struct;
82 typedef struct _LogDevAddr_struct {
83 DWORD VolId:30;
84 DWORD Mode:2;
85 BYTE reserved[4];
86 } LogDevAddr_struct;
88 typedef union _LUNAddr_struct {
89 BYTE LunAddrBytes[8];
90 SCSI3Addr_struct SCSI3Lun[4];
91 PhysDevAddr_struct PhysDev;
92 LogDevAddr_struct LogDev;
93 } LUNAddr_struct;
95 typedef struct _RequestBlock_struct {
96 BYTE CDBLen;
97 struct {
98 BYTE Type:3;
99 BYTE Attribute:3;
100 BYTE Direction:2;
101 } Type;
102 HWORD Timeout;
103 BYTE CDB[16];
104 } RequestBlock_struct;
106 typedef union _MoreErrInfo_struct{
107 struct {
108 BYTE Reserved[3];
109 BYTE Type;
110 DWORD ErrorInfo;
111 } Common_Info;
112 struct{
113 BYTE Reserved[2];
114 BYTE offense_size; /* size of offending entry */
115 BYTE offense_num; /* byte # of offense 0-base */
116 DWORD offense_value;
117 } Invalid_Cmd;
118 } MoreErrInfo_struct;
119 typedef struct _ErrorInfo_struct {
120 BYTE ScsiStatus;
121 BYTE SenseLen;
122 HWORD CommandStatus;
123 DWORD ResidualCnt;
124 MoreErrInfo_struct MoreErrInfo;
125 BYTE SenseInfo[SENSEINFOBYTES];
126 } ErrorInfo_struct;
128 #pragma pack()
130 #endif /* CCISS_DEFS_H */