pm: document use of RTC in pm_trace
[linux-2.6/linux-acpi-2.6/ibm-acpi-2.6.git] / include / linux / power_supply.h
blobea96ead1d39daa0ac621d12ae28633e30e4c7f71
1 /*
2 * Universal power supply monitor class
4 * Copyright © 2007 Anton Vorontsov <cbou@mail.ru>
5 * Copyright © 2004 Szabolcs Gyurko
6 * Copyright © 2003 Ian Molton <spyro@f2s.com>
8 * Modified: 2004, Oct Szabolcs Gyurko
10 * You may use this code as per GPL version 2
13 #ifndef __LINUX_POWER_SUPPLY_H__
14 #define __LINUX_POWER_SUPPLY_H__
16 #include <linux/device.h>
17 #include <linux/workqueue.h>
18 #include <linux/leds.h>
21 * All voltages, currents, charges, energies, time and temperatures in uV,
22 * µA, µAh, µWh, seconds and tenths of degree Celsius unless otherwise
23 * stated. It's driver's job to convert its raw values to units in which
24 * this class operates.
28 * For systems where the charger determines the maximum battery capacity
29 * the min and max fields should be used to present these values to user
30 * space. Unused/unknown fields will not appear in sysfs.
33 enum {
34 POWER_SUPPLY_STATUS_UNKNOWN = 0,
35 POWER_SUPPLY_STATUS_CHARGING,
36 POWER_SUPPLY_STATUS_DISCHARGING,
37 POWER_SUPPLY_STATUS_NOT_CHARGING,
38 POWER_SUPPLY_STATUS_FULL,
41 enum {
42 POWER_SUPPLY_HEALTH_UNKNOWN = 0,
43 POWER_SUPPLY_HEALTH_GOOD,
44 POWER_SUPPLY_HEALTH_OVERHEAT,
45 POWER_SUPPLY_HEALTH_DEAD,
46 POWER_SUPPLY_HEALTH_OVERVOLTAGE,
47 POWER_SUPPLY_HEALTH_UNSPEC_FAILURE,
50 enum {
51 POWER_SUPPLY_TECHNOLOGY_UNKNOWN = 0,
52 POWER_SUPPLY_TECHNOLOGY_NiMH,
53 POWER_SUPPLY_TECHNOLOGY_LION,
54 POWER_SUPPLY_TECHNOLOGY_LIPO,
55 POWER_SUPPLY_TECHNOLOGY_LiFe,
56 POWER_SUPPLY_TECHNOLOGY_NiCd,
57 POWER_SUPPLY_TECHNOLOGY_LiMn,
60 enum power_supply_property {
61 /* Properties of type `int' */
62 POWER_SUPPLY_PROP_STATUS = 0,
63 POWER_SUPPLY_PROP_HEALTH,
64 POWER_SUPPLY_PROP_PRESENT,
65 POWER_SUPPLY_PROP_ONLINE,
66 POWER_SUPPLY_PROP_TECHNOLOGY,
67 POWER_SUPPLY_PROP_VOLTAGE_MAX,
68 POWER_SUPPLY_PROP_VOLTAGE_MIN,
69 POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
70 POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
71 POWER_SUPPLY_PROP_VOLTAGE_NOW,
72 POWER_SUPPLY_PROP_VOLTAGE_AVG,
73 POWER_SUPPLY_PROP_CURRENT_NOW,
74 POWER_SUPPLY_PROP_CURRENT_AVG,
75 POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
76 POWER_SUPPLY_PROP_CHARGE_EMPTY_DESIGN,
77 POWER_SUPPLY_PROP_CHARGE_FULL,
78 POWER_SUPPLY_PROP_CHARGE_EMPTY,
79 POWER_SUPPLY_PROP_CHARGE_NOW,
80 POWER_SUPPLY_PROP_CHARGE_AVG,
81 POWER_SUPPLY_PROP_CHARGE_COUNTER,
82 POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
83 POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN,
84 POWER_SUPPLY_PROP_ENERGY_FULL,
85 POWER_SUPPLY_PROP_ENERGY_EMPTY,
86 POWER_SUPPLY_PROP_ENERGY_NOW,
87 POWER_SUPPLY_PROP_ENERGY_AVG,
88 POWER_SUPPLY_PROP_CAPACITY, /* in percents! */
89 POWER_SUPPLY_PROP_TEMP,
90 POWER_SUPPLY_PROP_TEMP_AMBIENT,
91 POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,
92 POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG,
93 POWER_SUPPLY_PROP_TIME_TO_FULL_NOW,
94 POWER_SUPPLY_PROP_TIME_TO_FULL_AVG,
95 /* Properties of type `const char *' */
96 POWER_SUPPLY_PROP_MODEL_NAME,
97 POWER_SUPPLY_PROP_MANUFACTURER,
98 POWER_SUPPLY_PROP_SERIAL_NUMBER,
101 enum power_supply_type {
102 POWER_SUPPLY_TYPE_BATTERY = 0,
103 POWER_SUPPLY_TYPE_UPS,
104 POWER_SUPPLY_TYPE_MAINS,
105 POWER_SUPPLY_TYPE_USB,
108 union power_supply_propval {
109 int intval;
110 const char *strval;
113 struct power_supply {
114 const char *name;
115 enum power_supply_type type;
116 enum power_supply_property *properties;
117 size_t num_properties;
119 char **supplied_to;
120 size_t num_supplicants;
122 int (*get_property)(struct power_supply *psy,
123 enum power_supply_property psp,
124 union power_supply_propval *val);
125 void (*external_power_changed)(struct power_supply *psy);
127 /* For APM emulation, think legacy userspace. */
128 int use_for_apm;
130 /* private */
131 struct device *dev;
132 struct work_struct changed_work;
134 #ifdef CONFIG_LEDS_TRIGGERS
135 struct led_trigger *charging_full_trig;
136 char *charging_full_trig_name;
137 struct led_trigger *charging_trig;
138 char *charging_trig_name;
139 struct led_trigger *full_trig;
140 char *full_trig_name;
141 struct led_trigger *online_trig;
142 char *online_trig_name;
143 #endif
147 * This is recommended structure to specify static power supply parameters.
148 * Generic one, parametrizable for different power supplies. Power supply
149 * class itself does not use it, but that's what implementing most platform
150 * drivers, should try reuse for consistency.
153 struct power_supply_info {
154 const char *name;
155 int technology;
156 int voltage_max_design;
157 int voltage_min_design;
158 int charge_full_design;
159 int charge_empty_design;
160 int energy_full_design;
161 int energy_empty_design;
162 int use_for_apm;
165 extern void power_supply_changed(struct power_supply *psy);
166 extern int power_supply_am_i_supplied(struct power_supply *psy);
168 extern int power_supply_register(struct device *parent,
169 struct power_supply *psy);
170 extern void power_supply_unregister(struct power_supply *psy);
172 /* For APM emulation, think legacy userspace. */
173 extern struct class *power_supply_class;
175 #endif /* __LINUX_POWER_SUPPLY_H__ */