ocfs2: Add metaecc for ocfs2_refcount_block.
[linux-2.6/linux-acpi-2.6/ibm-acpi-2.6.git] / drivers / md / Kconfig
blob020f9573fd82011babb4ad666a2966a44d088aba
2 # Block device driver configuration
5 menuconfig MD
6         bool "Multiple devices driver support (RAID and LVM)"
7         depends on BLOCK
8         help
9           Support multiple physical spindles through a single logical device.
10           Required for RAID and logical volume management.
12 if MD
14 config BLK_DEV_MD
15         tristate "RAID support"
16         ---help---
17           This driver lets you combine several hard disk partitions into one
18           logical block device. This can be used to simply append one
19           partition to another one or to combine several redundant hard disks
20           into a RAID1/4/5 device so as to provide protection against hard
21           disk failures. This is called "Software RAID" since the combining of
22           the partitions is done by the kernel. "Hardware RAID" means that the
23           combining is done by a dedicated controller; if you have such a
24           controller, you do not need to say Y here.
26           More information about Software RAID on Linux is contained in the
27           Software RAID mini-HOWTO, available from
28           <http://www.tldp.org/docs.html#howto>. There you will also learn
29           where to get the supporting user space utilities raidtools.
31           If unsure, say N.
33 config MD_AUTODETECT
34         bool "Autodetect RAID arrays during kernel boot"
35         depends on BLK_DEV_MD=y
36         default y
37         ---help---
38           If you say Y here, then the kernel will try to autodetect raid
39           arrays as part of its boot process. 
41           If you don't use raid and say Y, this autodetection can cause 
42           a several-second delay in the boot time due to various
43           synchronisation steps that are part of this step.
45           If unsure, say Y.
47 config MD_LINEAR
48         tristate "Linear (append) mode"
49         depends on BLK_DEV_MD
50         ---help---
51           If you say Y here, then your multiple devices driver will be able to
52           use the so-called linear mode, i.e. it will combine the hard disk
53           partitions by simply appending one to the other.
55           To compile this as a module, choose M here: the module
56           will be called linear.
58           If unsure, say Y.
60 config MD_RAID0
61         tristate "RAID-0 (striping) mode"
62         depends on BLK_DEV_MD
63         ---help---
64           If you say Y here, then your multiple devices driver will be able to
65           use the so-called raid0 mode, i.e. it will combine the hard disk
66           partitions into one logical device in such a fashion as to fill them
67           up evenly, one chunk here and one chunk there. This will increase
68           the throughput rate if the partitions reside on distinct disks.
70           Information about Software RAID on Linux is contained in the
71           Software-RAID mini-HOWTO, available from
72           <http://www.tldp.org/docs.html#howto>. There you will also
73           learn where to get the supporting user space utilities raidtools.
75           To compile this as a module, choose M here: the module
76           will be called raid0.
78           If unsure, say Y.
80 config MD_RAID1
81         tristate "RAID-1 (mirroring) mode"
82         depends on BLK_DEV_MD
83         ---help---
84           A RAID-1 set consists of several disk drives which are exact copies
85           of each other.  In the event of a mirror failure, the RAID driver
86           will continue to use the operational mirrors in the set, providing
87           an error free MD (multiple device) to the higher levels of the
88           kernel.  In a set with N drives, the available space is the capacity
89           of a single drive, and the set protects against a failure of (N - 1)
90           drives.
92           Information about Software RAID on Linux is contained in the
93           Software-RAID mini-HOWTO, available from
94           <http://www.tldp.org/docs.html#howto>.  There you will also
95           learn where to get the supporting user space utilities raidtools.
97           If you want to use such a RAID-1 set, say Y.  To compile this code
98           as a module, choose M here: the module will be called raid1.
100           If unsure, say Y.
102 config MD_RAID10
103         tristate "RAID-10 (mirrored striping) mode (EXPERIMENTAL)"
104         depends on BLK_DEV_MD && EXPERIMENTAL
105         ---help---
106           RAID-10 provides a combination of striping (RAID-0) and
107           mirroring (RAID-1) with easier configuration and more flexible
108           layout.
109           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110           be the same size (or at least, only as much as the smallest device
111           will be used).
112           RAID-10 provides a variety of layouts that provide different levels
113           of redundancy and performance.
115           RAID-10 requires mdadm-1.7.0 or later, available at:
117           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
119           If unsure, say Y.
121 config MD_RAID456
122         tristate "RAID-4/RAID-5/RAID-6 mode"
123         depends on BLK_DEV_MD
124         select MD_RAID6_PQ
125         select ASYNC_MEMCPY
126         select ASYNC_XOR
127         ---help---
128           A RAID-5 set of N drives with a capacity of C MB per drive provides
129           the capacity of C * (N - 1) MB, and protects against a failure
130           of a single drive. For a given sector (row) number, (N - 1) drives
131           contain data sectors, and one drive contains the parity protection.
132           For a RAID-4 set, the parity blocks are present on a single drive,
133           while a RAID-5 set distributes the parity across the drives in one
134           of the available parity distribution methods.
136           A RAID-6 set of N drives with a capacity of C MB per drive
137           provides the capacity of C * (N - 2) MB, and protects
138           against a failure of any two drives. For a given sector
139           (row) number, (N - 2) drives contain data sectors, and two
140           drives contains two independent redundancy syndromes.  Like
141           RAID-5, RAID-6 distributes the syndromes across the drives
142           in one of the available parity distribution methods.
144           Information about Software RAID on Linux is contained in the
145           Software-RAID mini-HOWTO, available from
146           <http://www.tldp.org/docs.html#howto>. There you will also
147           learn where to get the supporting user space utilities raidtools.
149           If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
150           compile this code as a module, choose M here: the module
151           will be called raid456.
153           If unsure, say Y.
155 config MD_RAID6_PQ
156         tristate
158 config MD_MULTIPATH
159         tristate "Multipath I/O support"
160         depends on BLK_DEV_MD
161         help
162           Multipath-IO is the ability of certain devices to address the same
163           physical disk over multiple 'IO paths'. The code ensures that such
164           paths can be defined and handled at runtime, and ensures that a
165           transparent failover to the backup path(s) happens if a IO errors
166           arrives on the primary path.
168           If unsure, say N.
170 config MD_FAULTY
171         tristate "Faulty test module for MD"
172         depends on BLK_DEV_MD
173         help
174           The "faulty" module allows for a block device that occasionally returns
175           read or write errors.  It is useful for testing.
177           In unsure, say N.
179 config BLK_DEV_DM
180         tristate "Device mapper support"
181         ---help---
182           Device-mapper is a low level volume manager.  It works by allowing
183           people to specify mappings for ranges of logical sectors.  Various
184           mapping types are available, in addition people may write their own
185           modules containing custom mappings if they wish.
187           Higher level volume managers such as LVM2 use this driver.
189           To compile this as a module, choose M here: the module will be
190           called dm-mod.
192           If unsure, say N.
194 config DM_DEBUG
195         boolean "Device mapper debugging support"
196         depends on BLK_DEV_DM
197         ---help---
198           Enable this for messages that may help debug device-mapper problems.
200           If unsure, say N.
202 config DM_CRYPT
203         tristate "Crypt target support"
204         depends on BLK_DEV_DM
205         select CRYPTO
206         select CRYPTO_CBC
207         ---help---
208           This device-mapper target allows you to create a device that
209           transparently encrypts the data on it. You'll need to activate
210           the ciphers you're going to use in the cryptoapi configuration.
212           Information on how to use dm-crypt can be found on
214           <http://www.saout.de/misc/dm-crypt/>
216           To compile this code as a module, choose M here: the module will
217           be called dm-crypt.
219           If unsure, say N.
221 config DM_SNAPSHOT
222        tristate "Snapshot target"
223        depends on BLK_DEV_DM
224        ---help---
225          Allow volume managers to take writable snapshots of a device.
227 config DM_MIRROR
228        tristate "Mirror target"
229        depends on BLK_DEV_DM
230        ---help---
231          Allow volume managers to mirror logical volumes, also
232          needed for live data migration tools such as 'pvmove'.
234 config DM_LOG_USERSPACE
235         tristate "Mirror userspace logging (EXPERIMENTAL)"
236         depends on DM_MIRROR && EXPERIMENTAL && NET
237         select CONNECTOR
238         ---help---
239           The userspace logging module provides a mechanism for
240           relaying the dm-dirty-log API to userspace.  Log designs
241           which are more suited to userspace implementation (e.g.
242           shared storage logs) or experimental logs can be implemented
243           by leveraging this framework.
245 config DM_ZERO
246         tristate "Zero target"
247         depends on BLK_DEV_DM
248         ---help---
249           A target that discards writes, and returns all zeroes for
250           reads.  Useful in some recovery situations.
252 config DM_MULTIPATH
253         tristate "Multipath target"
254         depends on BLK_DEV_DM
255         # nasty syntax but means make DM_MULTIPATH independent
256         # of SCSI_DH if the latter isn't defined but if
257         # it is, DM_MULTIPATH must depend on it.  We get a build
258         # error if SCSI_DH=m and DM_MULTIPATH=y
259         depends on SCSI_DH || !SCSI_DH
260         ---help---
261           Allow volume managers to support multipath hardware.
263 config DM_MULTIPATH_QL
264         tristate "I/O Path Selector based on the number of in-flight I/Os"
265         depends on DM_MULTIPATH
266         ---help---
267           This path selector is a dynamic load balancer which selects
268           the path with the least number of in-flight I/Os.
270           If unsure, say N.
272 config DM_MULTIPATH_ST
273         tristate "I/O Path Selector based on the service time"
274         depends on DM_MULTIPATH
275         ---help---
276           This path selector is a dynamic load balancer which selects
277           the path expected to complete the incoming I/O in the shortest
278           time.
280           If unsure, say N.
282 config DM_DELAY
283         tristate "I/O delaying target (EXPERIMENTAL)"
284         depends on BLK_DEV_DM && EXPERIMENTAL
285         ---help---
286         A target that delays reads and/or writes and can send
287         them to different devices.  Useful for testing.
289         If unsure, say N.
291 config DM_UEVENT
292         bool "DM uevents (EXPERIMENTAL)"
293         depends on BLK_DEV_DM && EXPERIMENTAL
294         ---help---
295         Generate udev events for DM events.
297 endif # MD