1 Kernel driver sht21
2 ===================
4 Supported chips:
5   * Sensirion SHT21
6     Prefix: 'sht21'
7     Addresses scanned: none
8     Datasheet: Publicly available at the Sensirion website
9     http://www.sensirion.com/en/pdf/product_information/Datasheet-humidity-sensor-SHT21.pdf
11   * Sensirion SHT25
12     Prefix: 'sht21'
13     Addresses scanned: none
14     Datasheet: Publicly available at the Sensirion website
15     http://www.sensirion.com/en/pdf/product_information/Datasheet-humidity-sensor-SHT25.pdf
17 Author:
18   Urs Fleisch <urs.fleisch@sensirion.com>
20 Description
21 -----------
23 The SHT21 and SHT25 are humidity and temperature sensors in a DFN package of
24 only 3 x 3 mm footprint and 1.1 mm height. The difference between the two
25 devices is the higher level of precision of the SHT25 (1.8% relative humidity,
26 0.2 degree Celsius) compared with the SHT21 (2.0% relative humidity,
27 0.3 degree Celsius).
29 The devices communicate with the I2C protocol. All sensors are set to the same
30 I2C address 0x40, so an entry with I2C_BOARD_INFO("sht21", 0x40) can be used
31 in the board setup code.
33 sysfs-Interface
34 ---------------
36 temp1_input - temperature input
37 humidity1_input - humidity input
39 Notes
40 -----
42 The driver uses the default resolution settings of 12 bit for humidity and 14
43 bit for temperature, which results in typical measurement times of 22 ms for
44 humidity and 66 ms for temperature. To keep self heating below 0.1 degree
45 Celsius, the device should not be active for more than 10% of the time,
46 e.g. maximum two measurements per second at the given resolution.
48 Different resolutions, the on-chip heater, using the CRC checksum and reading
49 the serial number are not supported yet.