NFSv4: Fix a bug when the server returns NFS4ERR_RESOURCE
[linux-2.6/kvm.git] / drivers / md / Kconfig
blob2158377a13593a45938278ac860d5de3db8a06fa
2 # Block device driver configuration
5 menuconfig MD
6         bool "Multiple devices driver support (RAID and LVM)"
7         depends on BLOCK
8         help
9           Support multiple physical spindles through a single logical device.
10           Required for RAID and logical volume management.
12 if MD
14 config BLK_DEV_MD
15         tristate "RAID support"
16         ---help---
17           This driver lets you combine several hard disk partitions into one
18           logical block device. This can be used to simply append one
19           partition to another one or to combine several redundant hard disks
20           into a RAID1/4/5 device so as to provide protection against hard
21           disk failures. This is called "Software RAID" since the combining of
22           the partitions is done by the kernel. "Hardware RAID" means that the
23           combining is done by a dedicated controller; if you have such a
24           controller, you do not need to say Y here.
26           More information about Software RAID on Linux is contained in the
27           Software RAID mini-HOWTO, available from
28           <http://www.tldp.org/docs.html#howto>. There you will also learn
29           where to get the supporting user space utilities raidtools.
31           If unsure, say N.
33 config MD_AUTODETECT
34         bool "Autodetect RAID arrays during kernel boot"
35         depends on BLK_DEV_MD=y
36         default y
37         ---help---
38           If you say Y here, then the kernel will try to autodetect raid
39           arrays as part of its boot process. 
41           If you don't use raid and say Y, this autodetection can cause 
42           a several-second delay in the boot time due to various
43           synchronisation steps that are part of this step.
45           If unsure, say Y.
47 config MD_LINEAR
48         tristate "Linear (append) mode"
49         depends on BLK_DEV_MD
50         ---help---
51           If you say Y here, then your multiple devices driver will be able to
52           use the so-called linear mode, i.e. it will combine the hard disk
53           partitions by simply appending one to the other.
55           To compile this as a module, choose M here: the module
56           will be called linear.
58           If unsure, say Y.
60 config MD_RAID0
61         tristate "RAID-0 (striping) mode"
62         depends on BLK_DEV_MD
63         ---help---
64           If you say Y here, then your multiple devices driver will be able to
65           use the so-called raid0 mode, i.e. it will combine the hard disk
66           partitions into one logical device in such a fashion as to fill them
67           up evenly, one chunk here and one chunk there. This will increase
68           the throughput rate if the partitions reside on distinct disks.
70           Information about Software RAID on Linux is contained in the
71           Software-RAID mini-HOWTO, available from
72           <http://www.tldp.org/docs.html#howto>. There you will also
73           learn where to get the supporting user space utilities raidtools.
75           To compile this as a module, choose M here: the module
76           will be called raid0.
78           If unsure, say Y.
80 config MD_RAID1
81         tristate "RAID-1 (mirroring) mode"
82         depends on BLK_DEV_MD
83         ---help---
84           A RAID-1 set consists of several disk drives which are exact copies
85           of each other.  In the event of a mirror failure, the RAID driver
86           will continue to use the operational mirrors in the set, providing
87           an error free MD (multiple device) to the higher levels of the
88           kernel.  In a set with N drives, the available space is the capacity
89           of a single drive, and the set protects against a failure of (N - 1)
90           drives.
92           Information about Software RAID on Linux is contained in the
93           Software-RAID mini-HOWTO, available from
94           <http://www.tldp.org/docs.html#howto>.  There you will also
95           learn where to get the supporting user space utilities raidtools.
97           If you want to use such a RAID-1 set, say Y.  To compile this code
98           as a module, choose M here: the module will be called raid1.
100           If unsure, say Y.
102 config MD_RAID10
103         tristate "RAID-10 (mirrored striping) mode (EXPERIMENTAL)"
104         depends on BLK_DEV_MD && EXPERIMENTAL
105         ---help---
106           RAID-10 provides a combination of striping (RAID-0) and
107           mirroring (RAID-1) with easier configuration and more flexible
108           layout.
109           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110           be the same size (or at least, only as much as the smallest device
111           will be used).
112           RAID-10 provides a variety of layouts that provide different levels
113           of redundancy and performance.
115           RAID-10 requires mdadm-1.7.0 or later, available at:
117           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
119           If unsure, say Y.
121 config MD_RAID456
122         tristate "RAID-4/RAID-5/RAID-6 mode"
123         depends on BLK_DEV_MD
124         select MD_RAID6_PQ
125         select ASYNC_MEMCPY
126         select ASYNC_XOR
127         select ASYNC_PQ
128         select ASYNC_RAID6_RECOV
129         ---help---
130           A RAID-5 set of N drives with a capacity of C MB per drive provides
131           the capacity of C * (N - 1) MB, and protects against a failure
132           of a single drive. For a given sector (row) number, (N - 1) drives
133           contain data sectors, and one drive contains the parity protection.
134           For a RAID-4 set, the parity blocks are present on a single drive,
135           while a RAID-5 set distributes the parity across the drives in one
136           of the available parity distribution methods.
138           A RAID-6 set of N drives with a capacity of C MB per drive
139           provides the capacity of C * (N - 2) MB, and protects
140           against a failure of any two drives. For a given sector
141           (row) number, (N - 2) drives contain data sectors, and two
142           drives contains two independent redundancy syndromes.  Like
143           RAID-5, RAID-6 distributes the syndromes across the drives
144           in one of the available parity distribution methods.
146           Information about Software RAID on Linux is contained in the
147           Software-RAID mini-HOWTO, available from
148           <http://www.tldp.org/docs.html#howto>. There you will also
149           learn where to get the supporting user space utilities raidtools.
151           If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
152           compile this code as a module, choose M here: the module
153           will be called raid456.
155           If unsure, say Y.
157 config MULTICORE_RAID456
158         bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)"
159         depends on MD_RAID456
160         depends on SMP
161         depends on EXPERIMENTAL
162         ---help---
163           Enable the raid456 module to dispatch per-stripe raid operations to a
164           thread pool.
166           If unsure, say N.
168 config MD_RAID6_PQ
169         tristate
171 config ASYNC_RAID6_TEST
172         tristate "Self test for hardware accelerated raid6 recovery"
173         depends on MD_RAID6_PQ
174         select ASYNC_RAID6_RECOV
175         ---help---
176           This is a one-shot self test that permutes through the
177           recovery of all the possible two disk failure scenarios for a
178           N-disk array.  Recovery is performed with the asynchronous
179           raid6 recovery routines, and will optionally use an offload
180           engine if one is available.
182           If unsure, say N.
184 config MD_MULTIPATH
185         tristate "Multipath I/O support"
186         depends on BLK_DEV_MD
187         help
188           Multipath-IO is the ability of certain devices to address the same
189           physical disk over multiple 'IO paths'. The code ensures that such
190           paths can be defined and handled at runtime, and ensures that a
191           transparent failover to the backup path(s) happens if a IO errors
192           arrives on the primary path.
194           If unsure, say N.
196 config MD_FAULTY
197         tristate "Faulty test module for MD"
198         depends on BLK_DEV_MD
199         help
200           The "faulty" module allows for a block device that occasionally returns
201           read or write errors.  It is useful for testing.
203           In unsure, say N.
205 config BLK_DEV_DM
206         tristate "Device mapper support"
207         ---help---
208           Device-mapper is a low level volume manager.  It works by allowing
209           people to specify mappings for ranges of logical sectors.  Various
210           mapping types are available, in addition people may write their own
211           modules containing custom mappings if they wish.
213           Higher level volume managers such as LVM2 use this driver.
215           To compile this as a module, choose M here: the module will be
216           called dm-mod.
218           If unsure, say N.
220 config DM_DEBUG
221         boolean "Device mapper debugging support"
222         depends on BLK_DEV_DM
223         ---help---
224           Enable this for messages that may help debug device-mapper problems.
226           If unsure, say N.
228 config DM_CRYPT
229         tristate "Crypt target support"
230         depends on BLK_DEV_DM
231         select CRYPTO
232         select CRYPTO_CBC
233         ---help---
234           This device-mapper target allows you to create a device that
235           transparently encrypts the data on it. You'll need to activate
236           the ciphers you're going to use in the cryptoapi configuration.
238           Information on how to use dm-crypt can be found on
240           <http://www.saout.de/misc/dm-crypt/>
242           To compile this code as a module, choose M here: the module will
243           be called dm-crypt.
245           If unsure, say N.
247 config DM_SNAPSHOT
248        tristate "Snapshot target"
249        depends on BLK_DEV_DM
250        ---help---
251          Allow volume managers to take writable snapshots of a device.
253 config DM_MIRROR
254        tristate "Mirror target"
255        depends on BLK_DEV_DM
256        ---help---
257          Allow volume managers to mirror logical volumes, also
258          needed for live data migration tools such as 'pvmove'.
260 config DM_LOG_USERSPACE
261         tristate "Mirror userspace logging (EXPERIMENTAL)"
262         depends on DM_MIRROR && EXPERIMENTAL && NET
263         select CONNECTOR
264         ---help---
265           The userspace logging module provides a mechanism for
266           relaying the dm-dirty-log API to userspace.  Log designs
267           which are more suited to userspace implementation (e.g.
268           shared storage logs) or experimental logs can be implemented
269           by leveraging this framework.
271 config DM_ZERO
272         tristate "Zero target"
273         depends on BLK_DEV_DM
274         ---help---
275           A target that discards writes, and returns all zeroes for
276           reads.  Useful in some recovery situations.
278 config DM_MULTIPATH
279         tristate "Multipath target"
280         depends on BLK_DEV_DM
281         # nasty syntax but means make DM_MULTIPATH independent
282         # of SCSI_DH if the latter isn't defined but if
283         # it is, DM_MULTIPATH must depend on it.  We get a build
284         # error if SCSI_DH=m and DM_MULTIPATH=y
285         depends on SCSI_DH || !SCSI_DH
286         ---help---
287           Allow volume managers to support multipath hardware.
289 config DM_MULTIPATH_QL
290         tristate "I/O Path Selector based on the number of in-flight I/Os"
291         depends on DM_MULTIPATH
292         ---help---
293           This path selector is a dynamic load balancer which selects
294           the path with the least number of in-flight I/Os.
296           If unsure, say N.
298 config DM_MULTIPATH_ST
299         tristate "I/O Path Selector based on the service time"
300         depends on DM_MULTIPATH
301         ---help---
302           This path selector is a dynamic load balancer which selects
303           the path expected to complete the incoming I/O in the shortest
304           time.
306           If unsure, say N.
308 config DM_DELAY
309         tristate "I/O delaying target (EXPERIMENTAL)"
310         depends on BLK_DEV_DM && EXPERIMENTAL
311         ---help---
312         A target that delays reads and/or writes and can send
313         them to different devices.  Useful for testing.
315         If unsure, say N.
317 config DM_UEVENT
318         bool "DM uevents (EXPERIMENTAL)"
319         depends on BLK_DEV_DM && EXPERIMENTAL
320         ---help---
321         Generate udev events for DM events.
323 endif # MD