be2net: increase FW update completion timeout
[linux-2.6.git] / Documentation / networking / bonding.txt
blob91df678fb7f88428f3989da217647d676e7121de
2                 Linux Ethernet Bonding Driver HOWTO
4                 Latest update: 27 April 2011
6 Initial release : Thomas Davis <tadavis at lbl.gov>
7 Corrections, HA extensions : 2000/10/03-15 :
8   - Willy Tarreau <willy at meta-x.org>
9   - Constantine Gavrilov <const-g at xpert.com>
10   - Chad N. Tindel <ctindel at ieee dot org>
11   - Janice Girouard <girouard at us dot ibm dot com>
12   - Jay Vosburgh <fubar at us dot ibm dot com>
14 Reorganized and updated Feb 2005 by Jay Vosburgh
15 Added Sysfs information: 2006/04/24
16   - Mitch Williams <mitch.a.williams at intel.com>
18 Introduction
19 ============
21         The Linux bonding driver provides a method for aggregating
22 multiple network interfaces into a single logical "bonded" interface.
23 The behavior of the bonded interfaces depends upon the mode; generally
24 speaking, modes provide either hot standby or load balancing services.
25 Additionally, link integrity monitoring may be performed.
26         
27         The bonding driver originally came from Donald Becker's
28 beowulf patches for kernel 2.0. It has changed quite a bit since, and
29 the original tools from extreme-linux and beowulf sites will not work
30 with this version of the driver.
32         For new versions of the driver, updated userspace tools, and
33 who to ask for help, please follow the links at the end of this file.
35 Table of Contents
36 =================
38 1. Bonding Driver Installation
40 2. Bonding Driver Options
42 3. Configuring Bonding Devices
43 3.1     Configuration with Sysconfig Support
44 3.1.1           Using DHCP with Sysconfig
45 3.1.2           Configuring Multiple Bonds with Sysconfig
46 3.2     Configuration with Initscripts Support
47 3.2.1           Using DHCP with Initscripts
48 3.2.2           Configuring Multiple Bonds with Initscripts
49 3.3     Configuring Bonding Manually with Ifenslave
50 3.3.1           Configuring Multiple Bonds Manually
51 3.4     Configuring Bonding Manually via Sysfs
52 3.5     Configuration with Interfaces Support
53 3.6     Overriding Configuration for Special Cases
55 4. Querying Bonding Configuration
56 4.1     Bonding Configuration
57 4.2     Network Configuration
59 5. Switch Configuration
61 6. 802.1q VLAN Support
63 7. Link Monitoring
64 7.1     ARP Monitor Operation
65 7.2     Configuring Multiple ARP Targets
66 7.3     MII Monitor Operation
68 8. Potential Trouble Sources
69 8.1     Adventures in Routing
70 8.2     Ethernet Device Renaming
71 8.3     Painfully Slow Or No Failed Link Detection By Miimon
73 9. SNMP agents
75 10. Promiscuous mode
77 11. Configuring Bonding for High Availability
78 11.1    High Availability in a Single Switch Topology
79 11.2    High Availability in a Multiple Switch Topology
80 11.2.1          HA Bonding Mode Selection for Multiple Switch Topology
81 11.2.2          HA Link Monitoring for Multiple Switch Topology
83 12. Configuring Bonding for Maximum Throughput
84 12.1    Maximum Throughput in a Single Switch Topology
85 12.1.1          MT Bonding Mode Selection for Single Switch Topology
86 12.1.2          MT Link Monitoring for Single Switch Topology
87 12.2    Maximum Throughput in a Multiple Switch Topology
88 12.2.1          MT Bonding Mode Selection for Multiple Switch Topology
89 12.2.2          MT Link Monitoring for Multiple Switch Topology
91 13. Switch Behavior Issues
92 13.1    Link Establishment and Failover Delays
93 13.2    Duplicated Incoming Packets
95 14. Hardware Specific Considerations
96 14.1    IBM BladeCenter
98 15. Frequently Asked Questions
100 16. Resources and Links
103 1. Bonding Driver Installation
104 ==============================
106         Most popular distro kernels ship with the bonding driver
107 already available as a module and the ifenslave user level control
108 program installed and ready for use. If your distro does not, or you
109 have need to compile bonding from source (e.g., configuring and
110 installing a mainline kernel from kernel.org), you'll need to perform
111 the following steps:
113 1.1 Configure and build the kernel with bonding
114 -----------------------------------------------
116         The current version of the bonding driver is available in the
117 drivers/net/bonding subdirectory of the most recent kernel source
118 (which is available on http://kernel.org).  Most users "rolling their
119 own" will want to use the most recent kernel from kernel.org.
121         Configure kernel with "make menuconfig" (or "make xconfig" or
122 "make config"), then select "Bonding driver support" in the "Network
123 device support" section.  It is recommended that you configure the
124 driver as module since it is currently the only way to pass parameters
125 to the driver or configure more than one bonding device.
127         Build and install the new kernel and modules, then continue
128 below to install ifenslave.
130 1.2 Install ifenslave Control Utility
131 -------------------------------------
133         The ifenslave user level control program is included in the
134 kernel source tree, in the file Documentation/networking/ifenslave.c.
135 It is generally recommended that you use the ifenslave that
136 corresponds to the kernel that you are using (either from the same
137 source tree or supplied with the distro), however, ifenslave
138 executables from older kernels should function (but features newer
139 than the ifenslave release are not supported).  Running an ifenslave
140 that is newer than the kernel is not supported, and may or may not
141 work.
143         To install ifenslave, do the following:
145 # gcc -Wall -O -I/usr/src/linux/include ifenslave.c -o ifenslave
146 # cp ifenslave /sbin/ifenslave
148         If your kernel source is not in "/usr/src/linux," then replace
149 "/usr/src/linux/include" in the above with the location of your kernel
150 source include directory.
152         You may wish to back up any existing /sbin/ifenslave, or, for
153 testing or informal use, tag the ifenslave to the kernel version
154 (e.g., name the ifenslave executable /sbin/ifenslave-2.6.10).
156 IMPORTANT NOTE:
158         If you omit the "-I" or specify an incorrect directory, you
159 may end up with an ifenslave that is incompatible with the kernel
160 you're trying to build it for.  Some distros (e.g., Red Hat from 7.1
161 onwards) do not have /usr/include/linux symbolically linked to the
162 default kernel source include directory.
164 SECOND IMPORTANT NOTE:
165         If you plan to configure bonding using sysfs or using the
166 /etc/network/interfaces file, you do not need to use ifenslave.
168 2. Bonding Driver Options
169 =========================
171         Options for the bonding driver are supplied as parameters to the
172 bonding module at load time, or are specified via sysfs.
174         Module options may be given as command line arguments to the
175 insmod or modprobe command, but are usually specified in either the
176 /etc/modules.conf or /etc/modprobe.conf configuration file, or in a
177 distro-specific configuration file (some of which are detailed in the next
178 section).
180         Details on bonding support for sysfs is provided in the
181 "Configuring Bonding Manually via Sysfs" section, below.
183         The available bonding driver parameters are listed below. If a
184 parameter is not specified the default value is used.  When initially
185 configuring a bond, it is recommended "tail -f /var/log/messages" be
186 run in a separate window to watch for bonding driver error messages.
188         It is critical that either the miimon or arp_interval and
189 arp_ip_target parameters be specified, otherwise serious network
190 degradation will occur during link failures.  Very few devices do not
191 support at least miimon, so there is really no reason not to use it.
193         Options with textual values will accept either the text name
194 or, for backwards compatibility, the option value.  E.g.,
195 "mode=802.3ad" and "mode=4" set the same mode.
197         The parameters are as follows:
199 ad_select
201         Specifies the 802.3ad aggregation selection logic to use.  The
202         possible values and their effects are:
204         stable or 0
206                 The active aggregator is chosen by largest aggregate
207                 bandwidth.
209                 Reselection of the active aggregator occurs only when all
210                 slaves of the active aggregator are down or the active
211                 aggregator has no slaves.
213                 This is the default value.
215         bandwidth or 1
217                 The active aggregator is chosen by largest aggregate
218                 bandwidth.  Reselection occurs if:
220                 - A slave is added to or removed from the bond
222                 - Any slave's link state changes
224                 - Any slave's 802.3ad association state changes
226                 - The bond's administrative state changes to up
228         count or 2
230                 The active aggregator is chosen by the largest number of
231                 ports (slaves).  Reselection occurs as described under the
232                 "bandwidth" setting, above.
234         The bandwidth and count selection policies permit failover of
235         802.3ad aggregations when partial failure of the active aggregator
236         occurs.  This keeps the aggregator with the highest availability
237         (either in bandwidth or in number of ports) active at all times.
239         This option was added in bonding version 3.4.0.
241 all_slaves_active
243         Specifies that duplicate frames (received on inactive ports) should be
244         dropped (0) or delivered (1).
246         Normally, bonding will drop duplicate frames (received on inactive
247         ports), which is desirable for most users. But there are some times
248         it is nice to allow duplicate frames to be delivered.
250         The default value is 0 (drop duplicate frames received on inactive
251         ports).
253 arp_interval
255         Specifies the ARP link monitoring frequency in milliseconds.
257         The ARP monitor works by periodically checking the slave
258         devices to determine whether they have sent or received
259         traffic recently (the precise criteria depends upon the
260         bonding mode, and the state of the slave).  Regular traffic is
261         generated via ARP probes issued for the addresses specified by
262         the arp_ip_target option.
264         This behavior can be modified by the arp_validate option,
265         below.
267         If ARP monitoring is used in an etherchannel compatible mode
268         (modes 0 and 2), the switch should be configured in a mode
269         that evenly distributes packets across all links. If the
270         switch is configured to distribute the packets in an XOR
271         fashion, all replies from the ARP targets will be received on
272         the same link which could cause the other team members to
273         fail.  ARP monitoring should not be used in conjunction with
274         miimon.  A value of 0 disables ARP monitoring.  The default
275         value is 0.
277 arp_ip_target
279         Specifies the IP addresses to use as ARP monitoring peers when
280         arp_interval is > 0.  These are the targets of the ARP request
281         sent to determine the health of the link to the targets.
282         Specify these values in ddd.ddd.ddd.ddd format.  Multiple IP
283         addresses must be separated by a comma.  At least one IP
284         address must be given for ARP monitoring to function.  The
285         maximum number of targets that can be specified is 16.  The
286         default value is no IP addresses.
288 arp_validate
290         Specifies whether or not ARP probes and replies should be
291         validated in the active-backup mode.  This causes the ARP
292         monitor to examine the incoming ARP requests and replies, and
293         only consider a slave to be up if it is receiving the
294         appropriate ARP traffic.
296         Possible values are:
298         none or 0
300                 No validation is performed.  This is the default.
302         active or 1
304                 Validation is performed only for the active slave.
306         backup or 2
308                 Validation is performed only for backup slaves.
310         all or 3
312                 Validation is performed for all slaves.
314         For the active slave, the validation checks ARP replies to
315         confirm that they were generated by an arp_ip_target.  Since
316         backup slaves do not typically receive these replies, the
317         validation performed for backup slaves is on the ARP request
318         sent out via the active slave.  It is possible that some
319         switch or network configurations may result in situations
320         wherein the backup slaves do not receive the ARP requests; in
321         such a situation, validation of backup slaves must be
322         disabled.
324         This option is useful in network configurations in which
325         multiple bonding hosts are concurrently issuing ARPs to one or
326         more targets beyond a common switch.  Should the link between
327         the switch and target fail (but not the switch itself), the
328         probe traffic generated by the multiple bonding instances will
329         fool the standard ARP monitor into considering the links as
330         still up.  Use of the arp_validate option can resolve this, as
331         the ARP monitor will only consider ARP requests and replies
332         associated with its own instance of bonding.
334         This option was added in bonding version 3.1.0.
336 downdelay
338         Specifies the time, in milliseconds, to wait before disabling
339         a slave after a link failure has been detected.  This option
340         is only valid for the miimon link monitor.  The downdelay
341         value should be a multiple of the miimon value; if not, it
342         will be rounded down to the nearest multiple.  The default
343         value is 0.
345 fail_over_mac
347         Specifies whether active-backup mode should set all slaves to
348         the same MAC address at enslavement (the traditional
349         behavior), or, when enabled, perform special handling of the
350         bond's MAC address in accordance with the selected policy.
352         Possible values are:
354         none or 0
356                 This setting disables fail_over_mac, and causes
357                 bonding to set all slaves of an active-backup bond to
358                 the same MAC address at enslavement time.  This is the
359                 default.
361         active or 1
363                 The "active" fail_over_mac policy indicates that the
364                 MAC address of the bond should always be the MAC
365                 address of the currently active slave.  The MAC
366                 address of the slaves is not changed; instead, the MAC
367                 address of the bond changes during a failover.
369                 This policy is useful for devices that cannot ever
370                 alter their MAC address, or for devices that refuse
371                 incoming broadcasts with their own source MAC (which
372                 interferes with the ARP monitor).
374                 The down side of this policy is that every device on
375                 the network must be updated via gratuitous ARP,
376                 vs. just updating a switch or set of switches (which
377                 often takes place for any traffic, not just ARP
378                 traffic, if the switch snoops incoming traffic to
379                 update its tables) for the traditional method.  If the
380                 gratuitous ARP is lost, communication may be
381                 disrupted.
383                 When this policy is used in conjunction with the mii
384                 monitor, devices which assert link up prior to being
385                 able to actually transmit and receive are particularly
386                 susceptible to loss of the gratuitous ARP, and an
387                 appropriate updelay setting may be required.
389         follow or 2
391                 The "follow" fail_over_mac policy causes the MAC
392                 address of the bond to be selected normally (normally
393                 the MAC address of the first slave added to the bond).
394                 However, the second and subsequent slaves are not set
395                 to this MAC address while they are in a backup role; a
396                 slave is programmed with the bond's MAC address at
397                 failover time (and the formerly active slave receives
398                 the newly active slave's MAC address).
400                 This policy is useful for multiport devices that
401                 either become confused or incur a performance penalty
402                 when multiple ports are programmed with the same MAC
403                 address.
406         The default policy is none, unless the first slave cannot
407         change its MAC address, in which case the active policy is
408         selected by default.
410         This option may be modified via sysfs only when no slaves are
411         present in the bond.
413         This option was added in bonding version 3.2.0.  The "follow"
414         policy was added in bonding version 3.3.0.
416 lacp_rate
418         Option specifying the rate in which we'll ask our link partner
419         to transmit LACPDU packets in 802.3ad mode.  Possible values
420         are:
422         slow or 0
423                 Request partner to transmit LACPDUs every 30 seconds
425         fast or 1
426                 Request partner to transmit LACPDUs every 1 second
428         The default is slow.
430 max_bonds
432         Specifies the number of bonding devices to create for this
433         instance of the bonding driver.  E.g., if max_bonds is 3, and
434         the bonding driver is not already loaded, then bond0, bond1
435         and bond2 will be created.  The default value is 1.  Specifying
436         a value of 0 will load bonding, but will not create any devices.
438 miimon
440         Specifies the MII link monitoring frequency in milliseconds.
441         This determines how often the link state of each slave is
442         inspected for link failures.  A value of zero disables MII
443         link monitoring.  A value of 100 is a good starting point.
444         The use_carrier option, below, affects how the link state is
445         determined.  See the High Availability section for additional
446         information.  The default value is 0.
448 min_links
450         Specifies the minimum number of links that must be active before
451         asserting carrier. It is similar to the Cisco EtherChannel min-links
452         feature. This allows setting the minimum number of member ports that
453         must be up (link-up state) before marking the bond device as up
454         (carrier on). This is useful for situations where higher level services
455         such as clustering want to ensure a minimum number of low bandwidth
456         links are active before switchover. This option only affect 802.3ad
457         mode.
459         The default value is 0. This will cause carrier to be asserted (for
460         802.3ad mode) whenever there is an active aggregator, regardless of the
461         number of available links in that aggregator. Note that, because an
462         aggregator cannot be active without at least one available link,
463         setting this option to 0 or to 1 has the exact same effect.
465 mode
467         Specifies one of the bonding policies. The default is
468         balance-rr (round robin).  Possible values are:
470         balance-rr or 0
472                 Round-robin policy: Transmit packets in sequential
473                 order from the first available slave through the
474                 last.  This mode provides load balancing and fault
475                 tolerance.
477         active-backup or 1
479                 Active-backup policy: Only one slave in the bond is
480                 active.  A different slave becomes active if, and only
481                 if, the active slave fails.  The bond's MAC address is
482                 externally visible on only one port (network adapter)
483                 to avoid confusing the switch.
485                 In bonding version 2.6.2 or later, when a failover
486                 occurs in active-backup mode, bonding will issue one
487                 or more gratuitous ARPs on the newly active slave.
488                 One gratuitous ARP is issued for the bonding master
489                 interface and each VLAN interfaces configured above
490                 it, provided that the interface has at least one IP
491                 address configured.  Gratuitous ARPs issued for VLAN
492                 interfaces are tagged with the appropriate VLAN id.
494                 This mode provides fault tolerance.  The primary
495                 option, documented below, affects the behavior of this
496                 mode.
498         balance-xor or 2
500                 XOR policy: Transmit based on the selected transmit
501                 hash policy.  The default policy is a simple [(source
502                 MAC address XOR'd with destination MAC address) modulo
503                 slave count].  Alternate transmit policies may be
504                 selected via the xmit_hash_policy option, described
505                 below.
507                 This mode provides load balancing and fault tolerance.
509         broadcast or 3
511                 Broadcast policy: transmits everything on all slave
512                 interfaces.  This mode provides fault tolerance.
514         802.3ad or 4
516                 IEEE 802.3ad Dynamic link aggregation.  Creates
517                 aggregation groups that share the same speed and
518                 duplex settings.  Utilizes all slaves in the active
519                 aggregator according to the 802.3ad specification.
521                 Slave selection for outgoing traffic is done according
522                 to the transmit hash policy, which may be changed from
523                 the default simple XOR policy via the xmit_hash_policy
524                 option, documented below.  Note that not all transmit
525                 policies may be 802.3ad compliant, particularly in
526                 regards to the packet mis-ordering requirements of
527                 section 43.2.4 of the 802.3ad standard.  Differing
528                 peer implementations will have varying tolerances for
529                 noncompliance.
531                 Prerequisites:
533                 1. Ethtool support in the base drivers for retrieving
534                 the speed and duplex of each slave.
536                 2. A switch that supports IEEE 802.3ad Dynamic link
537                 aggregation.
539                 Most switches will require some type of configuration
540                 to enable 802.3ad mode.
542         balance-tlb or 5
544                 Adaptive transmit load balancing: channel bonding that
545                 does not require any special switch support.  The
546                 outgoing traffic is distributed according to the
547                 current load (computed relative to the speed) on each
548                 slave.  Incoming traffic is received by the current
549                 slave.  If the receiving slave fails, another slave
550                 takes over the MAC address of the failed receiving
551                 slave.
553                 Prerequisite:
555                 Ethtool support in the base drivers for retrieving the
556                 speed of each slave.
558         balance-alb or 6
560                 Adaptive load balancing: includes balance-tlb plus
561                 receive load balancing (rlb) for IPV4 traffic, and
562                 does not require any special switch support.  The
563                 receive load balancing is achieved by ARP negotiation.
564                 The bonding driver intercepts the ARP Replies sent by
565                 the local system on their way out and overwrites the
566                 source hardware address with the unique hardware
567                 address of one of the slaves in the bond such that
568                 different peers use different hardware addresses for
569                 the server.
571                 Receive traffic from connections created by the server
572                 is also balanced.  When the local system sends an ARP
573                 Request the bonding driver copies and saves the peer's
574                 IP information from the ARP packet.  When the ARP
575                 Reply arrives from the peer, its hardware address is
576                 retrieved and the bonding driver initiates an ARP
577                 reply to this peer assigning it to one of the slaves
578                 in the bond.  A problematic outcome of using ARP
579                 negotiation for balancing is that each time that an
580                 ARP request is broadcast it uses the hardware address
581                 of the bond.  Hence, peers learn the hardware address
582                 of the bond and the balancing of receive traffic
583                 collapses to the current slave.  This is handled by
584                 sending updates (ARP Replies) to all the peers with
585                 their individually assigned hardware address such that
586                 the traffic is redistributed.  Receive traffic is also
587                 redistributed when a new slave is added to the bond
588                 and when an inactive slave is re-activated.  The
589                 receive load is distributed sequentially (round robin)
590                 among the group of highest speed slaves in the bond.
592                 When a link is reconnected or a new slave joins the
593                 bond the receive traffic is redistributed among all
594                 active slaves in the bond by initiating ARP Replies
595                 with the selected MAC address to each of the
596                 clients. The updelay parameter (detailed below) must
597                 be set to a value equal or greater than the switch's
598                 forwarding delay so that the ARP Replies sent to the
599                 peers will not be blocked by the switch.
601                 Prerequisites:
603                 1. Ethtool support in the base drivers for retrieving
604                 the speed of each slave.
606                 2. Base driver support for setting the hardware
607                 address of a device while it is open.  This is
608                 required so that there will always be one slave in the
609                 team using the bond hardware address (the
610                 curr_active_slave) while having a unique hardware
611                 address for each slave in the bond.  If the
612                 curr_active_slave fails its hardware address is
613                 swapped with the new curr_active_slave that was
614                 chosen.
616 num_grat_arp
617 num_unsol_na
619         Specify the number of peer notifications (gratuitous ARPs and
620         unsolicited IPv6 Neighbor Advertisements) to be issued after a
621         failover event.  As soon as the link is up on the new slave
622         (possibly immediately) a peer notification is sent on the
623         bonding device and each VLAN sub-device.  This is repeated at
624         each link monitor interval (arp_interval or miimon, whichever
625         is active) if the number is greater than 1.
627         The valid range is 0 - 255; the default value is 1.  These options
628         affect only the active-backup mode.  These options were added for
629         bonding versions 3.3.0 and 3.4.0 respectively.
631         From Linux 3.0 and bonding version 3.7.1, these notifications
632         are generated by the ipv4 and ipv6 code and the numbers of
633         repetitions cannot be set independently.
635 primary
637         A string (eth0, eth2, etc) specifying which slave is the
638         primary device.  The specified device will always be the
639         active slave while it is available.  Only when the primary is
640         off-line will alternate devices be used.  This is useful when
641         one slave is preferred over another, e.g., when one slave has
642         higher throughput than another.
644         The primary option is only valid for active-backup mode.
646 primary_reselect
648         Specifies the reselection policy for the primary slave.  This
649         affects how the primary slave is chosen to become the active slave
650         when failure of the active slave or recovery of the primary slave
651         occurs.  This option is designed to prevent flip-flopping between
652         the primary slave and other slaves.  Possible values are:
654         always or 0 (default)
656                 The primary slave becomes the active slave whenever it
657                 comes back up.
659         better or 1
661                 The primary slave becomes the active slave when it comes
662                 back up, if the speed and duplex of the primary slave is
663                 better than the speed and duplex of the current active
664                 slave.
666         failure or 2
668                 The primary slave becomes the active slave only if the
669                 current active slave fails and the primary slave is up.
671         The primary_reselect setting is ignored in two cases:
673                 If no slaves are active, the first slave to recover is
674                 made the active slave.
676                 When initially enslaved, the primary slave is always made
677                 the active slave.
679         Changing the primary_reselect policy via sysfs will cause an
680         immediate selection of the best active slave according to the new
681         policy.  This may or may not result in a change of the active
682         slave, depending upon the circumstances.
684         This option was added for bonding version 3.6.0.
686 updelay
688         Specifies the time, in milliseconds, to wait before enabling a
689         slave after a link recovery has been detected.  This option is
690         only valid for the miimon link monitor.  The updelay value
691         should be a multiple of the miimon value; if not, it will be
692         rounded down to the nearest multiple.  The default value is 0.
694 use_carrier
696         Specifies whether or not miimon should use MII or ETHTOOL
697         ioctls vs. netif_carrier_ok() to determine the link
698         status. The MII or ETHTOOL ioctls are less efficient and
699         utilize a deprecated calling sequence within the kernel.  The
700         netif_carrier_ok() relies on the device driver to maintain its
701         state with netif_carrier_on/off; at this writing, most, but
702         not all, device drivers support this facility.
704         If bonding insists that the link is up when it should not be,
705         it may be that your network device driver does not support
706         netif_carrier_on/off.  The default state for netif_carrier is
707         "carrier on," so if a driver does not support netif_carrier,
708         it will appear as if the link is always up.  In this case,
709         setting use_carrier to 0 will cause bonding to revert to the
710         MII / ETHTOOL ioctl method to determine the link state.
712         A value of 1 enables the use of netif_carrier_ok(), a value of
713         0 will use the deprecated MII / ETHTOOL ioctls.  The default
714         value is 1.
716 xmit_hash_policy
718         Selects the transmit hash policy to use for slave selection in
719         balance-xor and 802.3ad modes.  Possible values are:
721         layer2
723                 Uses XOR of hardware MAC addresses to generate the
724                 hash.  The formula is
726                 (source MAC XOR destination MAC) modulo slave count
728                 This algorithm will place all traffic to a particular
729                 network peer on the same slave.
731                 This algorithm is 802.3ad compliant.
733         layer2+3
735                 This policy uses a combination of layer2 and layer3
736                 protocol information to generate the hash.
738                 Uses XOR of hardware MAC addresses and IP addresses to
739                 generate the hash.  The formula is
741                 (((source IP XOR dest IP) AND 0xffff) XOR
742                         ( source MAC XOR destination MAC ))
743                                 modulo slave count
745                 This algorithm will place all traffic to a particular
746                 network peer on the same slave.  For non-IP traffic,
747                 the formula is the same as for the layer2 transmit
748                 hash policy.
750                 This policy is intended to provide a more balanced
751                 distribution of traffic than layer2 alone, especially
752                 in environments where a layer3 gateway device is
753                 required to reach most destinations.
755                 This algorithm is 802.3ad compliant.
757         layer3+4
759                 This policy uses upper layer protocol information,
760                 when available, to generate the hash.  This allows for
761                 traffic to a particular network peer to span multiple
762                 slaves, although a single connection will not span
763                 multiple slaves.
765                 The formula for unfragmented TCP and UDP packets is
767                 ((source port XOR dest port) XOR
768                          ((source IP XOR dest IP) AND 0xffff)
769                                 modulo slave count
771                 For fragmented TCP or UDP packets and all other IP
772                 protocol traffic, the source and destination port
773                 information is omitted.  For non-IP traffic, the
774                 formula is the same as for the layer2 transmit hash
775                 policy.
777                 This policy is intended to mimic the behavior of
778                 certain switches, notably Cisco switches with PFC2 as
779                 well as some Foundry and IBM products.
781                 This algorithm is not fully 802.3ad compliant.  A
782                 single TCP or UDP conversation containing both
783                 fragmented and unfragmented packets will see packets
784                 striped across two interfaces.  This may result in out
785                 of order delivery.  Most traffic types will not meet
786                 this criteria, as TCP rarely fragments traffic, and
787                 most UDP traffic is not involved in extended
788                 conversations.  Other implementations of 802.3ad may
789                 or may not tolerate this noncompliance.
791         The default value is layer2.  This option was added in bonding
792         version 2.6.3.  In earlier versions of bonding, this parameter
793         does not exist, and the layer2 policy is the only policy.  The
794         layer2+3 value was added for bonding version 3.2.2.
796 resend_igmp
798         Specifies the number of IGMP membership reports to be issued after
799         a failover event. One membership report is issued immediately after
800         the failover, subsequent packets are sent in each 200ms interval.
802         The valid range is 0 - 255; the default value is 1. A value of 0
803         prevents the IGMP membership report from being issued in response
804         to the failover event.
806         This option is useful for bonding modes balance-rr (0), active-backup
807         (1), balance-tlb (5) and balance-alb (6), in which a failover can
808         switch the IGMP traffic from one slave to another.  Therefore a fresh
809         IGMP report must be issued to cause the switch to forward the incoming
810         IGMP traffic over the newly selected slave.
812         This option was added for bonding version 3.7.0.
814 3. Configuring Bonding Devices
815 ==============================
817         You can configure bonding using either your distro's network
818 initialization scripts, or manually using either ifenslave or the
819 sysfs interface.  Distros generally use one of three packages for the
820 network initialization scripts: initscripts, sysconfig or interfaces.
821 Recent versions of these packages have support for bonding, while older
822 versions do not.
824         We will first describe the options for configuring bonding for
825 distros using versions of initscripts, sysconfig and interfaces with full
826 or partial support for bonding, then provide information on enabling
827 bonding without support from the network initialization scripts (i.e.,
828 older versions of initscripts or sysconfig).
830         If you're unsure whether your distro uses sysconfig,
831 initscripts or interfaces, or don't know if it's new enough, have no fear.
832 Determining this is fairly straightforward.
834         First, look for a file called interfaces in /etc/network directory.
835 If this file is present in your system, then your system use interfaces. See
836 Configuration with Interfaces Support.
838         Else, issue the command:
840 $ rpm -qf /sbin/ifup
842         It will respond with a line of text starting with either
843 "initscripts" or "sysconfig," followed by some numbers.  This is the
844 package that provides your network initialization scripts.
846         Next, to determine if your installation supports bonding,
847 issue the command:
849 $ grep ifenslave /sbin/ifup
851         If this returns any matches, then your initscripts or
852 sysconfig has support for bonding.
854 3.1 Configuration with Sysconfig Support
855 ----------------------------------------
857         This section applies to distros using a version of sysconfig
858 with bonding support, for example, SuSE Linux Enterprise Server 9.
860         SuSE SLES 9's networking configuration system does support
861 bonding, however, at this writing, the YaST system configuration
862 front end does not provide any means to work with bonding devices.
863 Bonding devices can be managed by hand, however, as follows.
865         First, if they have not already been configured, configure the
866 slave devices.  On SLES 9, this is most easily done by running the
867 yast2 sysconfig configuration utility.  The goal is for to create an
868 ifcfg-id file for each slave device.  The simplest way to accomplish
869 this is to configure the devices for DHCP (this is only to get the
870 file ifcfg-id file created; see below for some issues with DHCP).  The
871 name of the configuration file for each device will be of the form:
873 ifcfg-id-xx:xx:xx:xx:xx:xx
875         Where the "xx" portion will be replaced with the digits from
876 the device's permanent MAC address.
878         Once the set of ifcfg-id-xx:xx:xx:xx:xx:xx files has been
879 created, it is necessary to edit the configuration files for the slave
880 devices (the MAC addresses correspond to those of the slave devices).
881 Before editing, the file will contain multiple lines, and will look
882 something like this:
884 BOOTPROTO='dhcp'
885 STARTMODE='on'
886 USERCTL='no'
887 UNIQUE='XNzu.WeZGOGF+4wE'
888 _nm_name='bus-pci-0001:61:01.0'
890         Change the BOOTPROTO and STARTMODE lines to the following:
892 BOOTPROTO='none'
893 STARTMODE='off'
895         Do not alter the UNIQUE or _nm_name lines.  Remove any other
896 lines (USERCTL, etc).
898         Once the ifcfg-id-xx:xx:xx:xx:xx:xx files have been modified,
899 it's time to create the configuration file for the bonding device
900 itself.  This file is named ifcfg-bondX, where X is the number of the
901 bonding device to create, starting at 0.  The first such file is
902 ifcfg-bond0, the second is ifcfg-bond1, and so on.  The sysconfig
903 network configuration system will correctly start multiple instances
904 of bonding.
906         The contents of the ifcfg-bondX file is as follows:
908 BOOTPROTO="static"
909 BROADCAST="10.0.2.255"
910 IPADDR="10.0.2.10"
911 NETMASK="255.255.0.0"
912 NETWORK="10.0.2.0"
913 REMOTE_IPADDR=""
914 STARTMODE="onboot"
915 BONDING_MASTER="yes"
916 BONDING_MODULE_OPTS="mode=active-backup miimon=100"
917 BONDING_SLAVE0="eth0"
918 BONDING_SLAVE1="bus-pci-0000:06:08.1"
920         Replace the sample BROADCAST, IPADDR, NETMASK and NETWORK
921 values with the appropriate values for your network.
923         The STARTMODE specifies when the device is brought online.
924 The possible values are:
926         onboot:  The device is started at boot time.  If you're not
927                  sure, this is probably what you want.
929         manual:  The device is started only when ifup is called
930                  manually.  Bonding devices may be configured this
931                  way if you do not wish them to start automatically
932                  at boot for some reason.
934         hotplug: The device is started by a hotplug event.  This is not
935                  a valid choice for a bonding device.
937         off or ignore: The device configuration is ignored.
939         The line BONDING_MASTER='yes' indicates that the device is a
940 bonding master device.  The only useful value is "yes."
942         The contents of BONDING_MODULE_OPTS are supplied to the
943 instance of the bonding module for this device.  Specify the options
944 for the bonding mode, link monitoring, and so on here.  Do not include
945 the max_bonds bonding parameter; this will confuse the configuration
946 system if you have multiple bonding devices.
948         Finally, supply one BONDING_SLAVEn="slave device" for each
949 slave.  where "n" is an increasing value, one for each slave.  The
950 "slave device" is either an interface name, e.g., "eth0", or a device
951 specifier for the network device.  The interface name is easier to
952 find, but the ethN names are subject to change at boot time if, e.g.,
953 a device early in the sequence has failed.  The device specifiers
954 (bus-pci-0000:06:08.1 in the example above) specify the physical
955 network device, and will not change unless the device's bus location
956 changes (for example, it is moved from one PCI slot to another).  The
957 example above uses one of each type for demonstration purposes; most
958 configurations will choose one or the other for all slave devices.
960         When all configuration files have been modified or created,
961 networking must be restarted for the configuration changes to take
962 effect.  This can be accomplished via the following:
964 # /etc/init.d/network restart
966         Note that the network control script (/sbin/ifdown) will
967 remove the bonding module as part of the network shutdown processing,
968 so it is not necessary to remove the module by hand if, e.g., the
969 module parameters have changed.
971         Also, at this writing, YaST/YaST2 will not manage bonding
972 devices (they do not show bonding interfaces on its list of network
973 devices).  It is necessary to edit the configuration file by hand to
974 change the bonding configuration.
976         Additional general options and details of the ifcfg file
977 format can be found in an example ifcfg template file:
979 /etc/sysconfig/network/ifcfg.template
981         Note that the template does not document the various BONDING_
982 settings described above, but does describe many of the other options.
984 3.1.1 Using DHCP with Sysconfig
985 -------------------------------
987         Under sysconfig, configuring a device with BOOTPROTO='dhcp'
988 will cause it to query DHCP for its IP address information.  At this
989 writing, this does not function for bonding devices; the scripts
990 attempt to obtain the device address from DHCP prior to adding any of
991 the slave devices.  Without active slaves, the DHCP requests are not
992 sent to the network.
994 3.1.2 Configuring Multiple Bonds with Sysconfig
995 -----------------------------------------------
997         The sysconfig network initialization system is capable of
998 handling multiple bonding devices.  All that is necessary is for each
999 bonding instance to have an appropriately configured ifcfg-bondX file
1000 (as described above).  Do not specify the "max_bonds" parameter to any
1001 instance of bonding, as this will confuse sysconfig.  If you require
1002 multiple bonding devices with identical parameters, create multiple
1003 ifcfg-bondX files.
1005         Because the sysconfig scripts supply the bonding module
1006 options in the ifcfg-bondX file, it is not necessary to add them to
1007 the system /etc/modules.conf or /etc/modprobe.conf configuration file.
1009 3.2 Configuration with Initscripts Support
1010 ------------------------------------------
1012         This section applies to distros using a recent version of
1013 initscripts with bonding support, for example, Red Hat Enterprise Linux
1014 version 3 or later, Fedora, etc.  On these systems, the network
1015 initialization scripts have knowledge of bonding, and can be configured to
1016 control bonding devices.  Note that older versions of the initscripts
1017 package have lower levels of support for bonding; this will be noted where
1018 applicable.
1020         These distros will not automatically load the network adapter
1021 driver unless the ethX device is configured with an IP address.
1022 Because of this constraint, users must manually configure a
1023 network-script file for all physical adapters that will be members of
1024 a bondX link.  Network script files are located in the directory:
1026 /etc/sysconfig/network-scripts
1028         The file name must be prefixed with "ifcfg-eth" and suffixed
1029 with the adapter's physical adapter number.  For example, the script
1030 for eth0 would be named /etc/sysconfig/network-scripts/ifcfg-eth0.
1031 Place the following text in the file:
1033 DEVICE=eth0
1034 USERCTL=no
1035 ONBOOT=yes
1036 MASTER=bond0
1037 SLAVE=yes
1038 BOOTPROTO=none
1040         The DEVICE= line will be different for every ethX device and
1041 must correspond with the name of the file, i.e., ifcfg-eth1 must have
1042 a device line of DEVICE=eth1.  The setting of the MASTER= line will
1043 also depend on the final bonding interface name chosen for your bond.
1044 As with other network devices, these typically start at 0, and go up
1045 one for each device, i.e., the first bonding instance is bond0, the
1046 second is bond1, and so on.
1048         Next, create a bond network script.  The file name for this
1049 script will be /etc/sysconfig/network-scripts/ifcfg-bondX where X is
1050 the number of the bond.  For bond0 the file is named "ifcfg-bond0",
1051 for bond1 it is named "ifcfg-bond1", and so on.  Within that file,
1052 place the following text:
1054 DEVICE=bond0
1055 IPADDR=192.168.1.1
1056 NETMASK=255.255.255.0
1057 NETWORK=192.168.1.0
1058 BROADCAST=192.168.1.255
1059 ONBOOT=yes
1060 BOOTPROTO=none
1061 USERCTL=no
1063         Be sure to change the networking specific lines (IPADDR,
1064 NETMASK, NETWORK and BROADCAST) to match your network configuration.
1066         For later versions of initscripts, such as that found with Fedora
1067 7 (or later) and Red Hat Enterprise Linux version 5 (or later), it is possible,
1068 and, indeed, preferable, to specify the bonding options in the ifcfg-bond0
1069 file, e.g. a line of the format:
1071 BONDING_OPTS="mode=active-backup arp_interval=60 arp_ip_target=192.168.1.254"
1073         will configure the bond with the specified options.  The options
1074 specified in BONDING_OPTS are identical to the bonding module parameters
1075 except for the arp_ip_target field when using versions of initscripts older
1076 than and 8.57 (Fedora 8) and 8.45.19 (Red Hat Enterprise Linux 5.2).  When
1077 using older versions each target should be included as a separate option and
1078 should be preceded by a '+' to indicate it should be added to the list of
1079 queried targets, e.g.,
1081         arp_ip_target=+192.168.1.1 arp_ip_target=+192.168.1.2
1083         is the proper syntax to specify multiple targets.  When specifying
1084 options via BONDING_OPTS, it is not necessary to edit /etc/modules.conf or
1085 /etc/modprobe.conf.
1087         For even older versions of initscripts that do not support
1088 BONDING_OPTS, it is necessary to edit /etc/modules.conf (or
1089 /etc/modprobe.conf, depending upon your distro) to load the bonding module
1090 with your desired options when the bond0 interface is brought up.  The
1091 following lines in /etc/modules.conf (or modprobe.conf) will load the
1092 bonding module, and select its options:
1094 alias bond0 bonding
1095 options bond0 mode=balance-alb miimon=100
1097         Replace the sample parameters with the appropriate set of
1098 options for your configuration.
1100         Finally run "/etc/rc.d/init.d/network restart" as root.  This
1101 will restart the networking subsystem and your bond link should be now
1102 up and running.
1104 3.2.1 Using DHCP with Initscripts
1105 ---------------------------------
1107         Recent versions of initscripts (the versions supplied with Fedora
1108 Core 3 and Red Hat Enterprise Linux 4, or later versions, are reported to
1109 work) have support for assigning IP information to bonding devices via
1110 DHCP.
1112         To configure bonding for DHCP, configure it as described
1113 above, except replace the line "BOOTPROTO=none" with "BOOTPROTO=dhcp"
1114 and add a line consisting of "TYPE=Bonding".  Note that the TYPE value
1115 is case sensitive.
1117 3.2.2 Configuring Multiple Bonds with Initscripts
1118 -------------------------------------------------
1120         Initscripts packages that are included with Fedora 7 and Red Hat
1121 Enterprise Linux 5 support multiple bonding interfaces by simply
1122 specifying the appropriate BONDING_OPTS= in ifcfg-bondX where X is the
1123 number of the bond.  This support requires sysfs support in the kernel,
1124 and a bonding driver of version 3.0.0 or later.  Other configurations may
1125 not support this method for specifying multiple bonding interfaces; for
1126 those instances, see the "Configuring Multiple Bonds Manually" section,
1127 below.
1129 3.3 Configuring Bonding Manually with Ifenslave
1130 -----------------------------------------------
1132         This section applies to distros whose network initialization
1133 scripts (the sysconfig or initscripts package) do not have specific
1134 knowledge of bonding.  One such distro is SuSE Linux Enterprise Server
1135 version 8.
1137         The general method for these systems is to place the bonding
1138 module parameters into /etc/modules.conf or /etc/modprobe.conf (as
1139 appropriate for the installed distro), then add modprobe and/or
1140 ifenslave commands to the system's global init script.  The name of
1141 the global init script differs; for sysconfig, it is
1142 /etc/init.d/boot.local and for initscripts it is /etc/rc.d/rc.local.
1144         For example, if you wanted to make a simple bond of two e100
1145 devices (presumed to be eth0 and eth1), and have it persist across
1146 reboots, edit the appropriate file (/etc/init.d/boot.local or
1147 /etc/rc.d/rc.local), and add the following:
1149 modprobe bonding mode=balance-alb miimon=100
1150 modprobe e100
1151 ifconfig bond0 192.168.1.1 netmask 255.255.255.0 up
1152 ifenslave bond0 eth0
1153 ifenslave bond0 eth1
1155         Replace the example bonding module parameters and bond0
1156 network configuration (IP address, netmask, etc) with the appropriate
1157 values for your configuration.
1159         Unfortunately, this method will not provide support for the
1160 ifup and ifdown scripts on the bond devices.  To reload the bonding
1161 configuration, it is necessary to run the initialization script, e.g.,
1163 # /etc/init.d/boot.local
1165         or
1167 # /etc/rc.d/rc.local
1169         It may be desirable in such a case to create a separate script
1170 which only initializes the bonding configuration, then call that
1171 separate script from within boot.local.  This allows for bonding to be
1172 enabled without re-running the entire global init script.
1174         To shut down the bonding devices, it is necessary to first
1175 mark the bonding device itself as being down, then remove the
1176 appropriate device driver modules.  For our example above, you can do
1177 the following:
1179 # ifconfig bond0 down
1180 # rmmod bonding
1181 # rmmod e100
1183         Again, for convenience, it may be desirable to create a script
1184 with these commands.
1187 3.3.1 Configuring Multiple Bonds Manually
1188 -----------------------------------------
1190         This section contains information on configuring multiple
1191 bonding devices with differing options for those systems whose network
1192 initialization scripts lack support for configuring multiple bonds.
1194         If you require multiple bonding devices, but all with the same
1195 options, you may wish to use the "max_bonds" module parameter,
1196 documented above.
1198         To create multiple bonding devices with differing options, it is
1199 preferrable to use bonding parameters exported by sysfs, documented in the
1200 section below.
1202         For versions of bonding without sysfs support, the only means to
1203 provide multiple instances of bonding with differing options is to load
1204 the bonding driver multiple times.  Note that current versions of the
1205 sysconfig network initialization scripts handle this automatically; if
1206 your distro uses these scripts, no special action is needed.  See the
1207 section Configuring Bonding Devices, above, if you're not sure about your
1208 network initialization scripts.
1210         To load multiple instances of the module, it is necessary to
1211 specify a different name for each instance (the module loading system
1212 requires that every loaded module, even multiple instances of the same
1213 module, have a unique name).  This is accomplished by supplying multiple
1214 sets of bonding options in /etc/modprobe.conf, for example:
1216 alias bond0 bonding
1217 options bond0 -o bond0 mode=balance-rr miimon=100
1219 alias bond1 bonding
1220 options bond1 -o bond1 mode=balance-alb miimon=50
1222         will load the bonding module two times.  The first instance is
1223 named "bond0" and creates the bond0 device in balance-rr mode with an
1224 miimon of 100.  The second instance is named "bond1" and creates the
1225 bond1 device in balance-alb mode with an miimon of 50.
1227         In some circumstances (typically with older distributions),
1228 the above does not work, and the second bonding instance never sees
1229 its options.  In that case, the second options line can be substituted
1230 as follows:
1232 install bond1 /sbin/modprobe --ignore-install bonding -o bond1 \
1233         mode=balance-alb miimon=50
1235         This may be repeated any number of times, specifying a new and
1236 unique name in place of bond1 for each subsequent instance.
1238         It has been observed that some Red Hat supplied kernels are unable
1239 to rename modules at load time (the "-o bond1" part).  Attempts to pass
1240 that option to modprobe will produce an "Operation not permitted" error.
1241 This has been reported on some Fedora Core kernels, and has been seen on
1242 RHEL 4 as well.  On kernels exhibiting this problem, it will be impossible
1243 to configure multiple bonds with differing parameters (as they are older
1244 kernels, and also lack sysfs support).
1246 3.4 Configuring Bonding Manually via Sysfs
1247 ------------------------------------------
1249         Starting with version 3.0.0, Channel Bonding may be configured
1250 via the sysfs interface.  This interface allows dynamic configuration
1251 of all bonds in the system without unloading the module.  It also
1252 allows for adding and removing bonds at runtime.  Ifenslave is no
1253 longer required, though it is still supported.
1255         Use of the sysfs interface allows you to use multiple bonds
1256 with different configurations without having to reload the module.
1257 It also allows you to use multiple, differently configured bonds when
1258 bonding is compiled into the kernel.
1260         You must have the sysfs filesystem mounted to configure
1261 bonding this way.  The examples in this document assume that you
1262 are using the standard mount point for sysfs, e.g. /sys.  If your
1263 sysfs filesystem is mounted elsewhere, you will need to adjust the
1264 example paths accordingly.
1266 Creating and Destroying Bonds
1267 -----------------------------
1268 To add a new bond foo:
1269 # echo +foo > /sys/class/net/bonding_masters
1271 To remove an existing bond bar:
1272 # echo -bar > /sys/class/net/bonding_masters
1274 To show all existing bonds:
1275 # cat /sys/class/net/bonding_masters
1277 NOTE: due to 4K size limitation of sysfs files, this list may be
1278 truncated if you have more than a few hundred bonds.  This is unlikely
1279 to occur under normal operating conditions.
1281 Adding and Removing Slaves
1282 --------------------------
1283         Interfaces may be enslaved to a bond using the file
1284 /sys/class/net/<bond>/bonding/slaves.  The semantics for this file
1285 are the same as for the bonding_masters file.
1287 To enslave interface eth0 to bond bond0:
1288 # ifconfig bond0 up
1289 # echo +eth0 > /sys/class/net/bond0/bonding/slaves
1291 To free slave eth0 from bond bond0:
1292 # echo -eth0 > /sys/class/net/bond0/bonding/slaves
1294         When an interface is enslaved to a bond, symlinks between the
1295 two are created in the sysfs filesystem.  In this case, you would get
1296 /sys/class/net/bond0/slave_eth0 pointing to /sys/class/net/eth0, and
1297 /sys/class/net/eth0/master pointing to /sys/class/net/bond0.
1299         This means that you can tell quickly whether or not an
1300 interface is enslaved by looking for the master symlink.  Thus:
1301 # echo -eth0 > /sys/class/net/eth0/master/bonding/slaves
1302 will free eth0 from whatever bond it is enslaved to, regardless of
1303 the name of the bond interface.
1305 Changing a Bond's Configuration
1306 -------------------------------
1307         Each bond may be configured individually by manipulating the
1308 files located in /sys/class/net/<bond name>/bonding
1310         The names of these files correspond directly with the command-
1311 line parameters described elsewhere in this file, and, with the
1312 exception of arp_ip_target, they accept the same values.  To see the
1313 current setting, simply cat the appropriate file.
1315         A few examples will be given here; for specific usage
1316 guidelines for each parameter, see the appropriate section in this
1317 document.
1319 To configure bond0 for balance-alb mode:
1320 # ifconfig bond0 down
1321 # echo 6 > /sys/class/net/bond0/bonding/mode
1322  - or -
1323 # echo balance-alb > /sys/class/net/bond0/bonding/mode
1324         NOTE: The bond interface must be down before the mode can be
1325 changed.
1327 To enable MII monitoring on bond0 with a 1 second interval:
1328 # echo 1000 > /sys/class/net/bond0/bonding/miimon
1329         NOTE: If ARP monitoring is enabled, it will disabled when MII
1330 monitoring is enabled, and vice-versa.
1332 To add ARP targets:
1333 # echo +192.168.0.100 > /sys/class/net/bond0/bonding/arp_ip_target
1334 # echo +192.168.0.101 > /sys/class/net/bond0/bonding/arp_ip_target
1335         NOTE:  up to 16 target addresses may be specified.
1337 To remove an ARP target:
1338 # echo -192.168.0.100 > /sys/class/net/bond0/bonding/arp_ip_target
1340 Example Configuration
1341 ---------------------
1342         We begin with the same example that is shown in section 3.3,
1343 executed with sysfs, and without using ifenslave.
1345         To make a simple bond of two e100 devices (presumed to be eth0
1346 and eth1), and have it persist across reboots, edit the appropriate
1347 file (/etc/init.d/boot.local or /etc/rc.d/rc.local), and add the
1348 following:
1350 modprobe bonding
1351 modprobe e100
1352 echo balance-alb > /sys/class/net/bond0/bonding/mode
1353 ifconfig bond0 192.168.1.1 netmask 255.255.255.0 up
1354 echo 100 > /sys/class/net/bond0/bonding/miimon
1355 echo +eth0 > /sys/class/net/bond0/bonding/slaves
1356 echo +eth1 > /sys/class/net/bond0/bonding/slaves
1358         To add a second bond, with two e1000 interfaces in
1359 active-backup mode, using ARP monitoring, add the following lines to
1360 your init script:
1362 modprobe e1000
1363 echo +bond1 > /sys/class/net/bonding_masters
1364 echo active-backup > /sys/class/net/bond1/bonding/mode
1365 ifconfig bond1 192.168.2.1 netmask 255.255.255.0 up
1366 echo +192.168.2.100 /sys/class/net/bond1/bonding/arp_ip_target
1367 echo 2000 > /sys/class/net/bond1/bonding/arp_interval
1368 echo +eth2 > /sys/class/net/bond1/bonding/slaves
1369 echo +eth3 > /sys/class/net/bond1/bonding/slaves
1371 3.5 Configuration with Interfaces Support
1372 -----------------------------------------
1374         This section applies to distros which use /etc/network/interfaces file
1375 to describe network interface configuration, most notably Debian and it's
1376 derivatives.
1378         The ifup and ifdown commands on Debian don't support bonding out of
1379 the box. The ifenslave-2.6 package should be installed to provide bonding
1380 support.  Once installed, this package will provide bond-* options to be used
1381 into /etc/network/interfaces.
1383         Note that ifenslave-2.6 package will load the bonding module and use
1384 the ifenslave command when appropriate.
1386 Example Configurations
1387 ----------------------
1389 In /etc/network/interfaces, the following stanza will configure bond0, in
1390 active-backup mode, with eth0 and eth1 as slaves.
1392 auto bond0
1393 iface bond0 inet dhcp
1394         bond-slaves eth0 eth1
1395         bond-mode active-backup
1396         bond-miimon 100
1397         bond-primary eth0 eth1
1399 If the above configuration doesn't work, you might have a system using
1400 upstart for system startup. This is most notably true for recent
1401 Ubuntu versions. The following stanza in /etc/network/interfaces will
1402 produce the same result on those systems.
1404 auto bond0
1405 iface bond0 inet dhcp
1406         bond-slaves none
1407         bond-mode active-backup
1408         bond-miimon 100
1410 auto eth0
1411 iface eth0 inet manual
1412         bond-master bond0
1413         bond-primary eth0 eth1
1415 auto eth1
1416 iface eth1 inet manual
1417         bond-master bond0
1418         bond-primary eth0 eth1
1420 For a full list of bond-* supported options in /etc/network/interfaces and some
1421 more advanced examples tailored to you particular distros, see the files in
1422 /usr/share/doc/ifenslave-2.6.
1424 3.6 Overriding Configuration for Special Cases
1425 ----------------------------------------------
1427 When using the bonding driver, the physical port which transmits a frame is
1428 typically selected by the bonding driver, and is not relevant to the user or
1429 system administrator.  The output port is simply selected using the policies of
1430 the selected bonding mode.  On occasion however, it is helpful to direct certain
1431 classes of traffic to certain physical interfaces on output to implement
1432 slightly more complex policies.  For example, to reach a web server over a
1433 bonded interface in which eth0 connects to a private network, while eth1
1434 connects via a public network, it may be desirous to bias the bond to send said
1435 traffic over eth0 first, using eth1 only as a fall back, while all other traffic
1436 can safely be sent over either interface.  Such configurations may be achieved
1437 using the traffic control utilities inherent in linux.
1439 By default the bonding driver is multiqueue aware and 16 queues are created
1440 when the driver initializes (see Documentation/networking/multiqueue.txt
1441 for details).  If more or less queues are desired the module parameter
1442 tx_queues can be used to change this value.  There is no sysfs parameter
1443 available as the allocation is done at module init time.
1445 The output of the file /proc/net/bonding/bondX has changed so the output Queue
1446 ID is now printed for each slave:
1448 Bonding Mode: fault-tolerance (active-backup)
1449 Primary Slave: None
1450 Currently Active Slave: eth0
1451 MII Status: up
1452 MII Polling Interval (ms): 0
1453 Up Delay (ms): 0
1454 Down Delay (ms): 0
1456 Slave Interface: eth0
1457 MII Status: up
1458 Link Failure Count: 0
1459 Permanent HW addr: 00:1a:a0:12:8f:cb
1460 Slave queue ID: 0
1462 Slave Interface: eth1
1463 MII Status: up
1464 Link Failure Count: 0
1465 Permanent HW addr: 00:1a:a0:12:8f:cc
1466 Slave queue ID: 2
1468 The queue_id for a slave can be set using the command:
1470 # echo "eth1:2" > /sys/class/net/bond0/bonding/queue_id
1472 Any interface that needs a queue_id set should set it with multiple calls
1473 like the one above until proper priorities are set for all interfaces.  On
1474 distributions that allow configuration via initscripts, multiple 'queue_id'
1475 arguments can be added to BONDING_OPTS to set all needed slave queues.
1477 These queue id's can be used in conjunction with the tc utility to configure
1478 a multiqueue qdisc and filters to bias certain traffic to transmit on certain
1479 slave devices.  For instance, say we wanted, in the above configuration to
1480 force all traffic bound to 192.168.1.100 to use eth1 in the bond as its output
1481 device. The following commands would accomplish this:
1483 # tc qdisc add dev bond0 handle 1 root multiq
1485 # tc filter add dev bond0 protocol ip parent 1: prio 1 u32 match ip dst \
1486         192.168.1.100 action skbedit queue_mapping 2
1488 These commands tell the kernel to attach a multiqueue queue discipline to the
1489 bond0 interface and filter traffic enqueued to it, such that packets with a dst
1490 ip of 192.168.1.100 have their output queue mapping value overwritten to 2.
1491 This value is then passed into the driver, causing the normal output path
1492 selection policy to be overridden, selecting instead qid 2, which maps to eth1.
1494 Note that qid values begin at 1.  Qid 0 is reserved to initiate to the driver
1495 that normal output policy selection should take place.  One benefit to simply
1496 leaving the qid for a slave to 0 is the multiqueue awareness in the bonding
1497 driver that is now present.  This awareness allows tc filters to be placed on
1498 slave devices as well as bond devices and the bonding driver will simply act as
1499 a pass-through for selecting output queues on the slave device rather than 
1500 output port selection.
1502 This feature first appeared in bonding driver version 3.7.0 and support for
1503 output slave selection was limited to round-robin and active-backup modes.
1505 4 Querying Bonding Configuration
1506 =================================
1508 4.1 Bonding Configuration
1509 -------------------------
1511         Each bonding device has a read-only file residing in the
1512 /proc/net/bonding directory.  The file contents include information
1513 about the bonding configuration, options and state of each slave.
1515         For example, the contents of /proc/net/bonding/bond0 after the
1516 driver is loaded with parameters of mode=0 and miimon=1000 is
1517 generally as follows:
1519         Ethernet Channel Bonding Driver: 2.6.1 (October 29, 2004)
1520         Bonding Mode: load balancing (round-robin)
1521         Currently Active Slave: eth0
1522         MII Status: up
1523         MII Polling Interval (ms): 1000
1524         Up Delay (ms): 0
1525         Down Delay (ms): 0
1527         Slave Interface: eth1
1528         MII Status: up
1529         Link Failure Count: 1
1531         Slave Interface: eth0
1532         MII Status: up
1533         Link Failure Count: 1
1535         The precise format and contents will change depending upon the
1536 bonding configuration, state, and version of the bonding driver.
1538 4.2 Network configuration
1539 -------------------------
1541         The network configuration can be inspected using the ifconfig
1542 command.  Bonding devices will have the MASTER flag set; Bonding slave
1543 devices will have the SLAVE flag set.  The ifconfig output does not
1544 contain information on which slaves are associated with which masters.
1546         In the example below, the bond0 interface is the master
1547 (MASTER) while eth0 and eth1 are slaves (SLAVE). Notice all slaves of
1548 bond0 have the same MAC address (HWaddr) as bond0 for all modes except
1549 TLB and ALB that require a unique MAC address for each slave.
1551 # /sbin/ifconfig
1552 bond0     Link encap:Ethernet  HWaddr 00:C0:F0:1F:37:B4
1553           inet addr:XXX.XXX.XXX.YYY  Bcast:XXX.XXX.XXX.255  Mask:255.255.252.0
1554           UP BROADCAST RUNNING MASTER MULTICAST  MTU:1500  Metric:1
1555           RX packets:7224794 errors:0 dropped:0 overruns:0 frame:0
1556           TX packets:3286647 errors:1 dropped:0 overruns:1 carrier:0
1557           collisions:0 txqueuelen:0
1559 eth0      Link encap:Ethernet  HWaddr 00:C0:F0:1F:37:B4
1560           UP BROADCAST RUNNING SLAVE MULTICAST  MTU:1500  Metric:1
1561           RX packets:3573025 errors:0 dropped:0 overruns:0 frame:0
1562           TX packets:1643167 errors:1 dropped:0 overruns:1 carrier:0
1563           collisions:0 txqueuelen:100
1564           Interrupt:10 Base address:0x1080
1566 eth1      Link encap:Ethernet  HWaddr 00:C0:F0:1F:37:B4
1567           UP BROADCAST RUNNING SLAVE MULTICAST  MTU:1500  Metric:1
1568           RX packets:3651769 errors:0 dropped:0 overruns:0 frame:0
1569           TX packets:1643480 errors:0 dropped:0 overruns:0 carrier:0
1570           collisions:0 txqueuelen:100
1571           Interrupt:9 Base address:0x1400
1573 5. Switch Configuration
1574 =======================
1576         For this section, "switch" refers to whatever system the
1577 bonded devices are directly connected to (i.e., where the other end of
1578 the cable plugs into).  This may be an actual dedicated switch device,
1579 or it may be another regular system (e.g., another computer running
1580 Linux),
1582         The active-backup, balance-tlb and balance-alb modes do not
1583 require any specific configuration of the switch.
1585         The 802.3ad mode requires that the switch have the appropriate
1586 ports configured as an 802.3ad aggregation.  The precise method used
1587 to configure this varies from switch to switch, but, for example, a
1588 Cisco 3550 series switch requires that the appropriate ports first be
1589 grouped together in a single etherchannel instance, then that
1590 etherchannel is set to mode "lacp" to enable 802.3ad (instead of
1591 standard EtherChannel).
1593         The balance-rr, balance-xor and broadcast modes generally
1594 require that the switch have the appropriate ports grouped together.
1595 The nomenclature for such a group differs between switches, it may be
1596 called an "etherchannel" (as in the Cisco example, above), a "trunk
1597 group" or some other similar variation.  For these modes, each switch
1598 will also have its own configuration options for the switch's transmit
1599 policy to the bond.  Typical choices include XOR of either the MAC or
1600 IP addresses.  The transmit policy of the two peers does not need to
1601 match.  For these three modes, the bonding mode really selects a
1602 transmit policy for an EtherChannel group; all three will interoperate
1603 with another EtherChannel group.
1606 6. 802.1q VLAN Support
1607 ======================
1609         It is possible to configure VLAN devices over a bond interface
1610 using the 8021q driver.  However, only packets coming from the 8021q
1611 driver and passing through bonding will be tagged by default.  Self
1612 generated packets, for example, bonding's learning packets or ARP
1613 packets generated by either ALB mode or the ARP monitor mechanism, are
1614 tagged internally by bonding itself.  As a result, bonding must
1615 "learn" the VLAN IDs configured above it, and use those IDs to tag
1616 self generated packets.
1618         For reasons of simplicity, and to support the use of adapters
1619 that can do VLAN hardware acceleration offloading, the bonding
1620 interface declares itself as fully hardware offloading capable, it gets
1621 the add_vid/kill_vid notifications to gather the necessary
1622 information, and it propagates those actions to the slaves.  In case
1623 of mixed adapter types, hardware accelerated tagged packets that
1624 should go through an adapter that is not offloading capable are
1625 "un-accelerated" by the bonding driver so the VLAN tag sits in the
1626 regular location.
1628         VLAN interfaces *must* be added on top of a bonding interface
1629 only after enslaving at least one slave.  The bonding interface has a
1630 hardware address of 00:00:00:00:00:00 until the first slave is added.
1631 If the VLAN interface is created prior to the first enslavement, it
1632 would pick up the all-zeroes hardware address.  Once the first slave
1633 is attached to the bond, the bond device itself will pick up the
1634 slave's hardware address, which is then available for the VLAN device.
1636         Also, be aware that a similar problem can occur if all slaves
1637 are released from a bond that still has one or more VLAN interfaces on
1638 top of it.  When a new slave is added, the bonding interface will
1639 obtain its hardware address from the first slave, which might not
1640 match the hardware address of the VLAN interfaces (which was
1641 ultimately copied from an earlier slave).
1643         There are two methods to insure that the VLAN device operates
1644 with the correct hardware address if all slaves are removed from a
1645 bond interface:
1647         1. Remove all VLAN interfaces then recreate them
1649         2. Set the bonding interface's hardware address so that it
1650 matches the hardware address of the VLAN interfaces.
1652         Note that changing a VLAN interface's HW address would set the
1653 underlying device -- i.e. the bonding interface -- to promiscuous
1654 mode, which might not be what you want.
1657 7. Link Monitoring
1658 ==================
1660         The bonding driver at present supports two schemes for
1661 monitoring a slave device's link state: the ARP monitor and the MII
1662 monitor.
1664         At the present time, due to implementation restrictions in the
1665 bonding driver itself, it is not possible to enable both ARP and MII
1666 monitoring simultaneously.
1668 7.1 ARP Monitor Operation
1669 -------------------------
1671         The ARP monitor operates as its name suggests: it sends ARP
1672 queries to one or more designated peer systems on the network, and
1673 uses the response as an indication that the link is operating.  This
1674 gives some assurance that traffic is actually flowing to and from one
1675 or more peers on the local network.
1677         The ARP monitor relies on the device driver itself to verify
1678 that traffic is flowing.  In particular, the driver must keep up to
1679 date the last receive time, dev->last_rx, and transmit start time,
1680 dev->trans_start.  If these are not updated by the driver, then the
1681 ARP monitor will immediately fail any slaves using that driver, and
1682 those slaves will stay down.  If networking monitoring (tcpdump, etc)
1683 shows the ARP requests and replies on the network, then it may be that
1684 your device driver is not updating last_rx and trans_start.
1686 7.2 Configuring Multiple ARP Targets
1687 ------------------------------------
1689         While ARP monitoring can be done with just one target, it can
1690 be useful in a High Availability setup to have several targets to
1691 monitor.  In the case of just one target, the target itself may go
1692 down or have a problem making it unresponsive to ARP requests.  Having
1693 an additional target (or several) increases the reliability of the ARP
1694 monitoring.
1696         Multiple ARP targets must be separated by commas as follows:
1698 # example options for ARP monitoring with three targets
1699 alias bond0 bonding
1700 options bond0 arp_interval=60 arp_ip_target=192.168.0.1,192.168.0.3,192.168.0.9
1702         For just a single target the options would resemble:
1704 # example options for ARP monitoring with one target
1705 alias bond0 bonding
1706 options bond0 arp_interval=60 arp_ip_target=192.168.0.100
1709 7.3 MII Monitor Operation
1710 -------------------------
1712         The MII monitor monitors only the carrier state of the local
1713 network interface.  It accomplishes this in one of three ways: by
1714 depending upon the device driver to maintain its carrier state, by
1715 querying the device's MII registers, or by making an ethtool query to
1716 the device.
1718         If the use_carrier module parameter is 1 (the default value),
1719 then the MII monitor will rely on the driver for carrier state
1720 information (via the netif_carrier subsystem).  As explained in the
1721 use_carrier parameter information, above, if the MII monitor fails to
1722 detect carrier loss on the device (e.g., when the cable is physically
1723 disconnected), it may be that the driver does not support
1724 netif_carrier.
1726         If use_carrier is 0, then the MII monitor will first query the
1727 device's (via ioctl) MII registers and check the link state.  If that
1728 request fails (not just that it returns carrier down), then the MII
1729 monitor will make an ethtool ETHOOL_GLINK request to attempt to obtain
1730 the same information.  If both methods fail (i.e., the driver either
1731 does not support or had some error in processing both the MII register
1732 and ethtool requests), then the MII monitor will assume the link is
1735 8. Potential Sources of Trouble
1736 ===============================
1738 8.1 Adventures in Routing
1739 -------------------------
1741         When bonding is configured, it is important that the slave
1742 devices not have routes that supersede routes of the master (or,
1743 generally, not have routes at all).  For example, suppose the bonding
1744 device bond0 has two slaves, eth0 and eth1, and the routing table is
1745 as follows:
1747 Kernel IP routing table
1748 Destination     Gateway         Genmask         Flags   MSS Window  irtt Iface
1749 10.0.0.0        0.0.0.0         255.255.0.0     U        40 0          0 eth0
1750 10.0.0.0        0.0.0.0         255.255.0.0     U        40 0          0 eth1
1751 10.0.0.0        0.0.0.0         255.255.0.0     U        40 0          0 bond0
1752 127.0.0.0       0.0.0.0         255.0.0.0       U        40 0          0 lo
1754         This routing configuration will likely still update the
1755 receive/transmit times in the driver (needed by the ARP monitor), but
1756 may bypass the bonding driver (because outgoing traffic to, in this
1757 case, another host on network 10 would use eth0 or eth1 before bond0).
1759         The ARP monitor (and ARP itself) may become confused by this
1760 configuration, because ARP requests (generated by the ARP monitor)
1761 will be sent on one interface (bond0), but the corresponding reply
1762 will arrive on a different interface (eth0).  This reply looks to ARP
1763 as an unsolicited ARP reply (because ARP matches replies on an
1764 interface basis), and is discarded.  The MII monitor is not affected
1765 by the state of the routing table.
1767         The solution here is simply to insure that slaves do not have
1768 routes of their own, and if for some reason they must, those routes do
1769 not supersede routes of their master.  This should generally be the
1770 case, but unusual configurations or errant manual or automatic static
1771 route additions may cause trouble.
1773 8.2 Ethernet Device Renaming
1774 ----------------------------
1776         On systems with network configuration scripts that do not
1777 associate physical devices directly with network interface names (so
1778 that the same physical device always has the same "ethX" name), it may
1779 be necessary to add some special logic to either /etc/modules.conf or
1780 /etc/modprobe.conf (depending upon which is installed on the system).
1782         For example, given a modules.conf containing the following:
1784 alias bond0 bonding
1785 options bond0 mode=some-mode miimon=50
1786 alias eth0 tg3
1787 alias eth1 tg3
1788 alias eth2 e1000
1789 alias eth3 e1000
1791         If neither eth0 and eth1 are slaves to bond0, then when the
1792 bond0 interface comes up, the devices may end up reordered.  This
1793 happens because bonding is loaded first, then its slave device's
1794 drivers are loaded next.  Since no other drivers have been loaded,
1795 when the e1000 driver loads, it will receive eth0 and eth1 for its
1796 devices, but the bonding configuration tries to enslave eth2 and eth3
1797 (which may later be assigned to the tg3 devices).
1799         Adding the following:
1801 add above bonding e1000 tg3
1803         causes modprobe to load e1000 then tg3, in that order, when
1804 bonding is loaded.  This command is fully documented in the
1805 modules.conf manual page.
1807         On systems utilizing modprobe.conf (or modprobe.conf.local),
1808 an equivalent problem can occur.  In this case, the following can be
1809 added to modprobe.conf (or modprobe.conf.local, as appropriate), as
1810 follows (all on one line; it has been split here for clarity):
1812 install bonding /sbin/modprobe tg3; /sbin/modprobe e1000;
1813         /sbin/modprobe --ignore-install bonding
1815         This will, when loading the bonding module, rather than
1816 performing the normal action, instead execute the provided command.
1817 This command loads the device drivers in the order needed, then calls
1818 modprobe with --ignore-install to cause the normal action to then take
1819 place.  Full documentation on this can be found in the modprobe.conf
1820 and modprobe manual pages.
1822 8.3. Painfully Slow Or No Failed Link Detection By Miimon
1823 ---------------------------------------------------------
1825         By default, bonding enables the use_carrier option, which
1826 instructs bonding to trust the driver to maintain carrier state.
1828         As discussed in the options section, above, some drivers do
1829 not support the netif_carrier_on/_off link state tracking system.
1830 With use_carrier enabled, bonding will always see these links as up,
1831 regardless of their actual state.
1833         Additionally, other drivers do support netif_carrier, but do
1834 not maintain it in real time, e.g., only polling the link state at
1835 some fixed interval.  In this case, miimon will detect failures, but
1836 only after some long period of time has expired.  If it appears that
1837 miimon is very slow in detecting link failures, try specifying
1838 use_carrier=0 to see if that improves the failure detection time.  If
1839 it does, then it may be that the driver checks the carrier state at a
1840 fixed interval, but does not cache the MII register values (so the
1841 use_carrier=0 method of querying the registers directly works).  If
1842 use_carrier=0 does not improve the failover, then the driver may cache
1843 the registers, or the problem may be elsewhere.
1845         Also, remember that miimon only checks for the device's
1846 carrier state.  It has no way to determine the state of devices on or
1847 beyond other ports of a switch, or if a switch is refusing to pass
1848 traffic while still maintaining carrier on.
1850 9. SNMP agents
1851 ===============
1853         If running SNMP agents, the bonding driver should be loaded
1854 before any network drivers participating in a bond.  This requirement
1855 is due to the interface index (ipAdEntIfIndex) being associated to
1856 the first interface found with a given IP address.  That is, there is
1857 only one ipAdEntIfIndex for each IP address.  For example, if eth0 and
1858 eth1 are slaves of bond0 and the driver for eth0 is loaded before the
1859 bonding driver, the interface for the IP address will be associated
1860 with the eth0 interface.  This configuration is shown below, the IP
1861 address 192.168.1.1 has an interface index of 2 which indexes to eth0
1862 in the ifDescr table (ifDescr.2).
1864      interfaces.ifTable.ifEntry.ifDescr.1 = lo
1865      interfaces.ifTable.ifEntry.ifDescr.2 = eth0
1866      interfaces.ifTable.ifEntry.ifDescr.3 = eth1
1867      interfaces.ifTable.ifEntry.ifDescr.4 = eth2
1868      interfaces.ifTable.ifEntry.ifDescr.5 = eth3
1869      interfaces.ifTable.ifEntry.ifDescr.6 = bond0
1870      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.10.10.10 = 5
1871      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.192.168.1.1 = 2
1872      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.74.20.94 = 4
1873      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.127.0.0.1 = 1
1875         This problem is avoided by loading the bonding driver before
1876 any network drivers participating in a bond.  Below is an example of
1877 loading the bonding driver first, the IP address 192.168.1.1 is
1878 correctly associated with ifDescr.2.
1880      interfaces.ifTable.ifEntry.ifDescr.1 = lo
1881      interfaces.ifTable.ifEntry.ifDescr.2 = bond0
1882      interfaces.ifTable.ifEntry.ifDescr.3 = eth0
1883      interfaces.ifTable.ifEntry.ifDescr.4 = eth1
1884      interfaces.ifTable.ifEntry.ifDescr.5 = eth2
1885      interfaces.ifTable.ifEntry.ifDescr.6 = eth3
1886      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.10.10.10 = 6
1887      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.192.168.1.1 = 2
1888      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.74.20.94 = 5
1889      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.127.0.0.1 = 1
1891         While some distributions may not report the interface name in
1892 ifDescr, the association between the IP address and IfIndex remains
1893 and SNMP functions such as Interface_Scan_Next will report that
1894 association.
1896 10. Promiscuous mode
1897 ====================
1899         When running network monitoring tools, e.g., tcpdump, it is
1900 common to enable promiscuous mode on the device, so that all traffic
1901 is seen (instead of seeing only traffic destined for the local host).
1902 The bonding driver handles promiscuous mode changes to the bonding
1903 master device (e.g., bond0), and propagates the setting to the slave
1904 devices.
1906         For the balance-rr, balance-xor, broadcast, and 802.3ad modes,
1907 the promiscuous mode setting is propagated to all slaves.
1909         For the active-backup, balance-tlb and balance-alb modes, the
1910 promiscuous mode setting is propagated only to the active slave.
1912         For balance-tlb mode, the active slave is the slave currently
1913 receiving inbound traffic.
1915         For balance-alb mode, the active slave is the slave used as a
1916 "primary."  This slave is used for mode-specific control traffic, for
1917 sending to peers that are unassigned or if the load is unbalanced.
1919         For the active-backup, balance-tlb and balance-alb modes, when
1920 the active slave changes (e.g., due to a link failure), the
1921 promiscuous setting will be propagated to the new active slave.
1923 11. Configuring Bonding for High Availability
1924 =============================================
1926         High Availability refers to configurations that provide
1927 maximum network availability by having redundant or backup devices,
1928 links or switches between the host and the rest of the world.  The
1929 goal is to provide the maximum availability of network connectivity
1930 (i.e., the network always works), even though other configurations
1931 could provide higher throughput.
1933 11.1 High Availability in a Single Switch Topology
1934 --------------------------------------------------
1936         If two hosts (or a host and a single switch) are directly
1937 connected via multiple physical links, then there is no availability
1938 penalty to optimizing for maximum bandwidth.  In this case, there is
1939 only one switch (or peer), so if it fails, there is no alternative
1940 access to fail over to.  Additionally, the bonding load balance modes
1941 support link monitoring of their members, so if individual links fail,
1942 the load will be rebalanced across the remaining devices.
1944         See Section 13, "Configuring Bonding for Maximum Throughput"
1945 for information on configuring bonding with one peer device.
1947 11.2 High Availability in a Multiple Switch Topology
1948 ----------------------------------------------------
1950         With multiple switches, the configuration of bonding and the
1951 network changes dramatically.  In multiple switch topologies, there is
1952 a trade off between network availability and usable bandwidth.
1954         Below is a sample network, configured to maximize the
1955 availability of the network:
1957                 |                                     |
1958                 |port3                           port3|
1959           +-----+----+                          +-----+----+
1960           |          |port2       ISL      port2|          |
1961           | switch A +--------------------------+ switch B |
1962           |          |                          |          |
1963           +-----+----+                          +-----++---+
1964                 |port1                           port1|
1965                 |             +-------+               |
1966                 +-------------+ host1 +---------------+
1967                          eth0 +-------+ eth1
1969         In this configuration, there is a link between the two
1970 switches (ISL, or inter switch link), and multiple ports connecting to
1971 the outside world ("port3" on each switch).  There is no technical
1972 reason that this could not be extended to a third switch.
1974 11.2.1 HA Bonding Mode Selection for Multiple Switch Topology
1975 -------------------------------------------------------------
1977         In a topology such as the example above, the active-backup and
1978 broadcast modes are the only useful bonding modes when optimizing for
1979 availability; the other modes require all links to terminate on the
1980 same peer for them to behave rationally.
1982 active-backup: This is generally the preferred mode, particularly if
1983         the switches have an ISL and play together well.  If the
1984         network configuration is such that one switch is specifically
1985         a backup switch (e.g., has lower capacity, higher cost, etc),
1986         then the primary option can be used to insure that the
1987         preferred link is always used when it is available.
1989 broadcast: This mode is really a special purpose mode, and is suitable
1990         only for very specific needs.  For example, if the two
1991         switches are not connected (no ISL), and the networks beyond
1992         them are totally independent.  In this case, if it is
1993         necessary for some specific one-way traffic to reach both
1994         independent networks, then the broadcast mode may be suitable.
1996 11.2.2 HA Link Monitoring Selection for Multiple Switch Topology
1997 ----------------------------------------------------------------
1999         The choice of link monitoring ultimately depends upon your
2000 switch.  If the switch can reliably fail ports in response to other
2001 failures, then either the MII or ARP monitors should work.  For
2002 example, in the above example, if the "port3" link fails at the remote
2003 end, the MII monitor has no direct means to detect this.  The ARP
2004 monitor could be configured with a target at the remote end of port3,
2005 thus detecting that failure without switch support.
2007         In general, however, in a multiple switch topology, the ARP
2008 monitor can provide a higher level of reliability in detecting end to
2009 end connectivity failures (which may be caused by the failure of any
2010 individual component to pass traffic for any reason).  Additionally,
2011 the ARP monitor should be configured with multiple targets (at least
2012 one for each switch in the network).  This will insure that,
2013 regardless of which switch is active, the ARP monitor has a suitable
2014 target to query.
2016         Note, also, that of late many switches now support a functionality
2017 generally referred to as "trunk failover."  This is a feature of the
2018 switch that causes the link state of a particular switch port to be set
2019 down (or up) when the state of another switch port goes down (or up).
2020 Its purpose is to propagate link failures from logically "exterior" ports
2021 to the logically "interior" ports that bonding is able to monitor via
2022 miimon.  Availability and configuration for trunk failover varies by
2023 switch, but this can be a viable alternative to the ARP monitor when using
2024 suitable switches.
2026 12. Configuring Bonding for Maximum Throughput
2027 ==============================================
2029 12.1 Maximizing Throughput in a Single Switch Topology
2030 ------------------------------------------------------
2032         In a single switch configuration, the best method to maximize
2033 throughput depends upon the application and network environment.  The
2034 various load balancing modes each have strengths and weaknesses in
2035 different environments, as detailed below.
2037         For this discussion, we will break down the topologies into
2038 two categories.  Depending upon the destination of most traffic, we
2039 categorize them into either "gatewayed" or "local" configurations.
2041         In a gatewayed configuration, the "switch" is acting primarily
2042 as a router, and the majority of traffic passes through this router to
2043 other networks.  An example would be the following:
2046      +----------+                     +----------+
2047      |          |eth0            port1|          | to other networks
2048      | Host A   +---------------------+ router   +------------------->
2049      |          +---------------------+          | Hosts B and C are out
2050      |          |eth1            port2|          | here somewhere
2051      +----------+                     +----------+
2053         The router may be a dedicated router device, or another host
2054 acting as a gateway.  For our discussion, the important point is that
2055 the majority of traffic from Host A will pass through the router to
2056 some other network before reaching its final destination.
2058         In a gatewayed network configuration, although Host A may
2059 communicate with many other systems, all of its traffic will be sent
2060 and received via one other peer on the local network, the router.
2062         Note that the case of two systems connected directly via
2063 multiple physical links is, for purposes of configuring bonding, the
2064 same as a gatewayed configuration.  In that case, it happens that all
2065 traffic is destined for the "gateway" itself, not some other network
2066 beyond the gateway.
2068         In a local configuration, the "switch" is acting primarily as
2069 a switch, and the majority of traffic passes through this switch to
2070 reach other stations on the same network.  An example would be the
2071 following:
2073     +----------+            +----------+       +--------+
2074     |          |eth0   port1|          +-------+ Host B |
2075     |  Host A  +------------+  switch  |port3  +--------+
2076     |          +------------+          |                  +--------+
2077     |          |eth1   port2|          +------------------+ Host C |
2078     +----------+            +----------+port4             +--------+
2081         Again, the switch may be a dedicated switch device, or another
2082 host acting as a gateway.  For our discussion, the important point is
2083 that the majority of traffic from Host A is destined for other hosts
2084 on the same local network (Hosts B and C in the above example).
2086         In summary, in a gatewayed configuration, traffic to and from
2087 the bonded device will be to the same MAC level peer on the network
2088 (the gateway itself, i.e., the router), regardless of its final
2089 destination.  In a local configuration, traffic flows directly to and
2090 from the final destinations, thus, each destination (Host B, Host C)
2091 will be addressed directly by their individual MAC addresses.
2093         This distinction between a gatewayed and a local network
2094 configuration is important because many of the load balancing modes
2095 available use the MAC addresses of the local network source and
2096 destination to make load balancing decisions.  The behavior of each
2097 mode is described below.
2100 12.1.1 MT Bonding Mode Selection for Single Switch Topology
2101 -----------------------------------------------------------
2103         This configuration is the easiest to set up and to understand,
2104 although you will have to decide which bonding mode best suits your
2105 needs.  The trade offs for each mode are detailed below:
2107 balance-rr: This mode is the only mode that will permit a single
2108         TCP/IP connection to stripe traffic across multiple
2109         interfaces. It is therefore the only mode that will allow a
2110         single TCP/IP stream to utilize more than one interface's
2111         worth of throughput.  This comes at a cost, however: the
2112         striping generally results in peer systems receiving packets out
2113         of order, causing TCP/IP's congestion control system to kick
2114         in, often by retransmitting segments.
2116         It is possible to adjust TCP/IP's congestion limits by
2117         altering the net.ipv4.tcp_reordering sysctl parameter.  The
2118         usual default value is 3, and the maximum useful value is 127.
2119         For a four interface balance-rr bond, expect that a single
2120         TCP/IP stream will utilize no more than approximately 2.3
2121         interface's worth of throughput, even after adjusting
2122         tcp_reordering.
2124         Note that the fraction of packets that will be delivered out of
2125         order is highly variable, and is unlikely to be zero.  The level
2126         of reordering depends upon a variety of factors, including the
2127         networking interfaces, the switch, and the topology of the
2128         configuration.  Speaking in general terms, higher speed network
2129         cards produce more reordering (due to factors such as packet
2130         coalescing), and a "many to many" topology will reorder at a
2131         higher rate than a "many slow to one fast" configuration.
2133         Many switches do not support any modes that stripe traffic
2134         (instead choosing a port based upon IP or MAC level addresses);
2135         for those devices, traffic for a particular connection flowing
2136         through the switch to a balance-rr bond will not utilize greater
2137         than one interface's worth of bandwidth.
2139         If you are utilizing protocols other than TCP/IP, UDP for
2140         example, and your application can tolerate out of order
2141         delivery, then this mode can allow for single stream datagram
2142         performance that scales near linearly as interfaces are added
2143         to the bond.
2145         This mode requires the switch to have the appropriate ports
2146         configured for "etherchannel" or "trunking."
2148 active-backup: There is not much advantage in this network topology to
2149         the active-backup mode, as the inactive backup devices are all
2150         connected to the same peer as the primary.  In this case, a
2151         load balancing mode (with link monitoring) will provide the
2152         same level of network availability, but with increased
2153         available bandwidth.  On the plus side, active-backup mode
2154         does not require any configuration of the switch, so it may
2155         have value if the hardware available does not support any of
2156         the load balance modes.
2158 balance-xor: This mode will limit traffic such that packets destined
2159         for specific peers will always be sent over the same
2160         interface.  Since the destination is determined by the MAC
2161         addresses involved, this mode works best in a "local" network
2162         configuration (as described above), with destinations all on
2163         the same local network.  This mode is likely to be suboptimal
2164         if all your traffic is passed through a single router (i.e., a
2165         "gatewayed" network configuration, as described above).
2167         As with balance-rr, the switch ports need to be configured for
2168         "etherchannel" or "trunking."
2170 broadcast: Like active-backup, there is not much advantage to this
2171         mode in this type of network topology.
2173 802.3ad: This mode can be a good choice for this type of network
2174         topology.  The 802.3ad mode is an IEEE standard, so all peers
2175         that implement 802.3ad should interoperate well.  The 802.3ad
2176         protocol includes automatic configuration of the aggregates,
2177         so minimal manual configuration of the switch is needed
2178         (typically only to designate that some set of devices is
2179         available for 802.3ad).  The 802.3ad standard also mandates
2180         that frames be delivered in order (within certain limits), so
2181         in general single connections will not see misordering of
2182         packets.  The 802.3ad mode does have some drawbacks: the
2183         standard mandates that all devices in the aggregate operate at
2184         the same speed and duplex.  Also, as with all bonding load
2185         balance modes other than balance-rr, no single connection will
2186         be able to utilize more than a single interface's worth of
2187         bandwidth.  
2189         Additionally, the linux bonding 802.3ad implementation
2190         distributes traffic by peer (using an XOR of MAC addresses),
2191         so in a "gatewayed" configuration, all outgoing traffic will
2192         generally use the same device.  Incoming traffic may also end
2193         up on a single device, but that is dependent upon the
2194         balancing policy of the peer's 8023.ad implementation.  In a
2195         "local" configuration, traffic will be distributed across the
2196         devices in the bond.
2198         Finally, the 802.3ad mode mandates the use of the MII monitor,
2199         therefore, the ARP monitor is not available in this mode.
2201 balance-tlb: The balance-tlb mode balances outgoing traffic by peer.
2202         Since the balancing is done according to MAC address, in a
2203         "gatewayed" configuration (as described above), this mode will
2204         send all traffic across a single device.  However, in a
2205         "local" network configuration, this mode balances multiple
2206         local network peers across devices in a vaguely intelligent
2207         manner (not a simple XOR as in balance-xor or 802.3ad mode),
2208         so that mathematically unlucky MAC addresses (i.e., ones that
2209         XOR to the same value) will not all "bunch up" on a single
2210         interface.
2212         Unlike 802.3ad, interfaces may be of differing speeds, and no
2213         special switch configuration is required.  On the down side,
2214         in this mode all incoming traffic arrives over a single
2215         interface, this mode requires certain ethtool support in the
2216         network device driver of the slave interfaces, and the ARP
2217         monitor is not available.
2219 balance-alb: This mode is everything that balance-tlb is, and more.
2220         It has all of the features (and restrictions) of balance-tlb,
2221         and will also balance incoming traffic from local network
2222         peers (as described in the Bonding Module Options section,
2223         above).
2225         The only additional down side to this mode is that the network
2226         device driver must support changing the hardware address while
2227         the device is open.
2229 12.1.2 MT Link Monitoring for Single Switch Topology
2230 ----------------------------------------------------
2232         The choice of link monitoring may largely depend upon which
2233 mode you choose to use.  The more advanced load balancing modes do not
2234 support the use of the ARP monitor, and are thus restricted to using
2235 the MII monitor (which does not provide as high a level of end to end
2236 assurance as the ARP monitor).
2238 12.2 Maximum Throughput in a Multiple Switch Topology
2239 -----------------------------------------------------
2241         Multiple switches may be utilized to optimize for throughput
2242 when they are configured in parallel as part of an isolated network
2243 between two or more systems, for example:
2245                        +-----------+
2246                        |  Host A   | 
2247                        +-+---+---+-+
2248                          |   |   |
2249                 +--------+   |   +---------+
2250                 |            |             |
2251          +------+---+  +-----+----+  +-----+----+
2252          | Switch A |  | Switch B |  | Switch C |
2253          +------+---+  +-----+----+  +-----+----+
2254                 |            |             |
2255                 +--------+   |   +---------+
2256                          |   |   |
2257                        +-+---+---+-+
2258                        |  Host B   | 
2259                        +-----------+
2261         In this configuration, the switches are isolated from one
2262 another.  One reason to employ a topology such as this is for an
2263 isolated network with many hosts (a cluster configured for high
2264 performance, for example), using multiple smaller switches can be more
2265 cost effective than a single larger switch, e.g., on a network with 24
2266 hosts, three 24 port switches can be significantly less expensive than
2267 a single 72 port switch.
2269         If access beyond the network is required, an individual host
2270 can be equipped with an additional network device connected to an
2271 external network; this host then additionally acts as a gateway.
2273 12.2.1 MT Bonding Mode Selection for Multiple Switch Topology
2274 -------------------------------------------------------------
2276         In actual practice, the bonding mode typically employed in
2277 configurations of this type is balance-rr.  Historically, in this
2278 network configuration, the usual caveats about out of order packet
2279 delivery are mitigated by the use of network adapters that do not do
2280 any kind of packet coalescing (via the use of NAPI, or because the
2281 device itself does not generate interrupts until some number of
2282 packets has arrived).  When employed in this fashion, the balance-rr
2283 mode allows individual connections between two hosts to effectively
2284 utilize greater than one interface's bandwidth.
2286 12.2.2 MT Link Monitoring for Multiple Switch Topology
2287 ------------------------------------------------------
2289         Again, in actual practice, the MII monitor is most often used
2290 in this configuration, as performance is given preference over
2291 availability.  The ARP monitor will function in this topology, but its
2292 advantages over the MII monitor are mitigated by the volume of probes
2293 needed as the number of systems involved grows (remember that each
2294 host in the network is configured with bonding).
2296 13. Switch Behavior Issues
2297 ==========================
2299 13.1 Link Establishment and Failover Delays
2300 -------------------------------------------
2302         Some switches exhibit undesirable behavior with regard to the
2303 timing of link up and down reporting by the switch.
2305         First, when a link comes up, some switches may indicate that
2306 the link is up (carrier available), but not pass traffic over the
2307 interface for some period of time.  This delay is typically due to
2308 some type of autonegotiation or routing protocol, but may also occur
2309 during switch initialization (e.g., during recovery after a switch
2310 failure).  If you find this to be a problem, specify an appropriate
2311 value to the updelay bonding module option to delay the use of the
2312 relevant interface(s).
2314         Second, some switches may "bounce" the link state one or more
2315 times while a link is changing state.  This occurs most commonly while
2316 the switch is initializing.  Again, an appropriate updelay value may
2317 help.
2319         Note that when a bonding interface has no active links, the
2320 driver will immediately reuse the first link that goes up, even if the
2321 updelay parameter has been specified (the updelay is ignored in this
2322 case).  If there are slave interfaces waiting for the updelay timeout
2323 to expire, the interface that first went into that state will be
2324 immediately reused.  This reduces down time of the network if the
2325 value of updelay has been overestimated, and since this occurs only in
2326 cases with no connectivity, there is no additional penalty for
2327 ignoring the updelay.
2329         In addition to the concerns about switch timings, if your
2330 switches take a long time to go into backup mode, it may be desirable
2331 to not activate a backup interface immediately after a link goes down.
2332 Failover may be delayed via the downdelay bonding module option.
2334 13.2 Duplicated Incoming Packets
2335 --------------------------------
2337         NOTE: Starting with version 3.0.2, the bonding driver has logic to
2338 suppress duplicate packets, which should largely eliminate this problem.
2339 The following description is kept for reference.
2341         It is not uncommon to observe a short burst of duplicated
2342 traffic when the bonding device is first used, or after it has been
2343 idle for some period of time.  This is most easily observed by issuing
2344 a "ping" to some other host on the network, and noticing that the
2345 output from ping flags duplicates (typically one per slave).
2347         For example, on a bond in active-backup mode with five slaves
2348 all connected to one switch, the output may appear as follows:
2350 # ping -n 10.0.4.2
2351 PING 10.0.4.2 (10.0.4.2) from 10.0.3.10 : 56(84) bytes of data.
2352 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.7 ms
2353 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2354 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2355 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2356 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2357 64 bytes from 10.0.4.2: icmp_seq=2 ttl=64 time=0.216 ms
2358 64 bytes from 10.0.4.2: icmp_seq=3 ttl=64 time=0.267 ms
2359 64 bytes from 10.0.4.2: icmp_seq=4 ttl=64 time=0.222 ms
2361         This is not due to an error in the bonding driver, rather, it
2362 is a side effect of how many switches update their MAC forwarding
2363 tables.  Initially, the switch does not associate the MAC address in
2364 the packet with a particular switch port, and so it may send the
2365 traffic to all ports until its MAC forwarding table is updated.  Since
2366 the interfaces attached to the bond may occupy multiple ports on a
2367 single switch, when the switch (temporarily) floods the traffic to all
2368 ports, the bond device receives multiple copies of the same packet
2369 (one per slave device).
2371         The duplicated packet behavior is switch dependent, some
2372 switches exhibit this, and some do not.  On switches that display this
2373 behavior, it can be induced by clearing the MAC forwarding table (on
2374 most Cisco switches, the privileged command "clear mac address-table
2375 dynamic" will accomplish this).
2377 14. Hardware Specific Considerations
2378 ====================================
2380         This section contains additional information for configuring
2381 bonding on specific hardware platforms, or for interfacing bonding
2382 with particular switches or other devices.
2384 14.1 IBM BladeCenter
2385 --------------------
2387         This applies to the JS20 and similar systems.
2389         On the JS20 blades, the bonding driver supports only
2390 balance-rr, active-backup, balance-tlb and balance-alb modes.  This is
2391 largely due to the network topology inside the BladeCenter, detailed
2392 below.
2394 JS20 network adapter information
2395 --------------------------------
2397         All JS20s come with two Broadcom Gigabit Ethernet ports
2398 integrated on the planar (that's "motherboard" in IBM-speak).  In the
2399 BladeCenter chassis, the eth0 port of all JS20 blades is hard wired to
2400 I/O Module #1; similarly, all eth1 ports are wired to I/O Module #2.
2401 An add-on Broadcom daughter card can be installed on a JS20 to provide
2402 two more Gigabit Ethernet ports.  These ports, eth2 and eth3, are
2403 wired to I/O Modules 3 and 4, respectively.
2405         Each I/O Module may contain either a switch or a passthrough
2406 module (which allows ports to be directly connected to an external
2407 switch).  Some bonding modes require a specific BladeCenter internal
2408 network topology in order to function; these are detailed below.
2410         Additional BladeCenter-specific networking information can be
2411 found in two IBM Redbooks (www.ibm.com/redbooks):
2413 "IBM eServer BladeCenter Networking Options"
2414 "IBM eServer BladeCenter Layer 2-7 Network Switching"
2416 BladeCenter networking configuration
2417 ------------------------------------
2419         Because a BladeCenter can be configured in a very large number
2420 of ways, this discussion will be confined to describing basic
2421 configurations.
2423         Normally, Ethernet Switch Modules (ESMs) are used in I/O
2424 modules 1 and 2.  In this configuration, the eth0 and eth1 ports of a
2425 JS20 will be connected to different internal switches (in the
2426 respective I/O modules).
2428         A passthrough module (OPM or CPM, optical or copper,
2429 passthrough module) connects the I/O module directly to an external
2430 switch.  By using PMs in I/O module #1 and #2, the eth0 and eth1
2431 interfaces of a JS20 can be redirected to the outside world and
2432 connected to a common external switch.
2434         Depending upon the mix of ESMs and PMs, the network will
2435 appear to bonding as either a single switch topology (all PMs) or as a
2436 multiple switch topology (one or more ESMs, zero or more PMs).  It is
2437 also possible to connect ESMs together, resulting in a configuration
2438 much like the example in "High Availability in a Multiple Switch
2439 Topology," above.
2441 Requirements for specific modes
2442 -------------------------------
2444         The balance-rr mode requires the use of passthrough modules
2445 for devices in the bond, all connected to an common external switch.
2446 That switch must be configured for "etherchannel" or "trunking" on the
2447 appropriate ports, as is usual for balance-rr.
2449         The balance-alb and balance-tlb modes will function with
2450 either switch modules or passthrough modules (or a mix).  The only
2451 specific requirement for these modes is that all network interfaces
2452 must be able to reach all destinations for traffic sent over the
2453 bonding device (i.e., the network must converge at some point outside
2454 the BladeCenter).
2456         The active-backup mode has no additional requirements.
2458 Link monitoring issues
2459 ----------------------
2461         When an Ethernet Switch Module is in place, only the ARP
2462 monitor will reliably detect link loss to an external switch.  This is
2463 nothing unusual, but examination of the BladeCenter cabinet would
2464 suggest that the "external" network ports are the ethernet ports for
2465 the system, when it fact there is a switch between these "external"
2466 ports and the devices on the JS20 system itself.  The MII monitor is
2467 only able to detect link failures between the ESM and the JS20 system.
2469         When a passthrough module is in place, the MII monitor does
2470 detect failures to the "external" port, which is then directly
2471 connected to the JS20 system.
2473 Other concerns
2474 --------------
2476         The Serial Over LAN (SoL) link is established over the primary
2477 ethernet (eth0) only, therefore, any loss of link to eth0 will result
2478 in losing your SoL connection.  It will not fail over with other
2479 network traffic, as the SoL system is beyond the control of the
2480 bonding driver.
2482         It may be desirable to disable spanning tree on the switch
2483 (either the internal Ethernet Switch Module, or an external switch) to
2484 avoid fail-over delay issues when using bonding.
2486         
2487 15. Frequently Asked Questions
2488 ==============================
2490 1.  Is it SMP safe?
2492         Yes. The old 2.0.xx channel bonding patch was not SMP safe.
2493 The new driver was designed to be SMP safe from the start.
2495 2.  What type of cards will work with it?
2497         Any Ethernet type cards (you can even mix cards - a Intel
2498 EtherExpress PRO/100 and a 3com 3c905b, for example).  For most modes,
2499 devices need not be of the same speed.
2501         Starting with version 3.2.1, bonding also supports Infiniband
2502 slaves in active-backup mode.
2504 3.  How many bonding devices can I have?
2506         There is no limit.
2508 4.  How many slaves can a bonding device have?
2510         This is limited only by the number of network interfaces Linux
2511 supports and/or the number of network cards you can place in your
2512 system.
2514 5.  What happens when a slave link dies?
2516         If link monitoring is enabled, then the failing device will be
2517 disabled.  The active-backup mode will fail over to a backup link, and
2518 other modes will ignore the failed link.  The link will continue to be
2519 monitored, and should it recover, it will rejoin the bond (in whatever
2520 manner is appropriate for the mode). See the sections on High
2521 Availability and the documentation for each mode for additional
2522 information.
2523         
2524         Link monitoring can be enabled via either the miimon or
2525 arp_interval parameters (described in the module parameters section,
2526 above).  In general, miimon monitors the carrier state as sensed by
2527 the underlying network device, and the arp monitor (arp_interval)
2528 monitors connectivity to another host on the local network.
2530         If no link monitoring is configured, the bonding driver will
2531 be unable to detect link failures, and will assume that all links are
2532 always available.  This will likely result in lost packets, and a
2533 resulting degradation of performance.  The precise performance loss
2534 depends upon the bonding mode and network configuration.
2536 6.  Can bonding be used for High Availability?
2538         Yes.  See the section on High Availability for details.
2540 7.  Which switches/systems does it work with?
2542         The full answer to this depends upon the desired mode.
2544         In the basic balance modes (balance-rr and balance-xor), it
2545 works with any system that supports etherchannel (also called
2546 trunking).  Most managed switches currently available have such
2547 support, and many unmanaged switches as well.
2549         The advanced balance modes (balance-tlb and balance-alb) do
2550 not have special switch requirements, but do need device drivers that
2551 support specific features (described in the appropriate section under
2552 module parameters, above).
2554         In 802.3ad mode, it works with systems that support IEEE
2555 802.3ad Dynamic Link Aggregation.  Most managed and many unmanaged
2556 switches currently available support 802.3ad.
2558         The active-backup mode should work with any Layer-II switch.
2560 8.  Where does a bonding device get its MAC address from?
2562         When using slave devices that have fixed MAC addresses, or when
2563 the fail_over_mac option is enabled, the bonding device's MAC address is
2564 the MAC address of the active slave.
2566         For other configurations, if not explicitly configured (with
2567 ifconfig or ip link), the MAC address of the bonding device is taken from
2568 its first slave device.  This MAC address is then passed to all following
2569 slaves and remains persistent (even if the first slave is removed) until
2570 the bonding device is brought down or reconfigured.
2572         If you wish to change the MAC address, you can set it with
2573 ifconfig or ip link:
2575 # ifconfig bond0 hw ether 00:11:22:33:44:55
2577 # ip link set bond0 address 66:77:88:99:aa:bb
2579         The MAC address can be also changed by bringing down/up the
2580 device and then changing its slaves (or their order):
2582 # ifconfig bond0 down ; modprobe -r bonding
2583 # ifconfig bond0 .... up
2584 # ifenslave bond0 eth...
2586         This method will automatically take the address from the next
2587 slave that is added.
2589         To restore your slaves' MAC addresses, you need to detach them
2590 from the bond (`ifenslave -d bond0 eth0'). The bonding driver will
2591 then restore the MAC addresses that the slaves had before they were
2592 enslaved.
2594 16. Resources and Links
2595 =======================
2597         The latest version of the bonding driver can be found in the latest
2598 version of the linux kernel, found on http://kernel.org
2600         The latest version of this document can be found in the latest kernel
2601 source (named Documentation/networking/bonding.txt).
2603         Discussions regarding the usage of the bonding driver take place on the
2604 bonding-devel mailing list, hosted at sourceforge.net. If you have questions or
2605 problems, post them to the list.  The list address is:
2607 bonding-devel@lists.sourceforge.net
2609         The administrative interface (to subscribe or unsubscribe) can
2610 be found at:
2612 https://lists.sourceforge.net/lists/listinfo/bonding-devel
2614         Discussions regarding the developpement of the bonding driver take place
2615 on the main Linux network mailing list, hosted at vger.kernel.org. The list
2616 address is:
2618 netdev@vger.kernel.org
2620         The administrative interface (to subscribe or unsubscribe) can
2621 be found at:
2623 http://vger.kernel.org/vger-lists.html#netdev
2625 Donald Becker's Ethernet Drivers and diag programs may be found at :
2626  - http://web.archive.org/web/*/http://www.scyld.com/network/ 
2628 You will also find a lot of information regarding Ethernet, NWay, MII,
2629 etc. at www.scyld.com.
2631 -- END --