mm: vmscan: immediately reclaim end-of-LRU dirty pages when writeback completes
[linux-2.6.git] / Documentation / hwmon / ntc_thermistor
blob3bfda94096fd3893c431370b182c156ae5ade126
1 Kernel driver ntc_thermistor
2 =================
4 Supported thermistors:
5 * Murata NTC Thermistors NCP15WB473, NCP18WB473, NCP21WB473, NCP03WB473, NCP15WL333
6   Prefixes: 'ncp15wb473', 'ncp18wb473', 'ncp21wb473', 'ncp03wb473', 'ncp15wl333'
7   Datasheet: Publicly available at Murata
9 Other NTC thermistors can be supported simply by adding compensation
10 tables; e.g., NCP15WL333 support is added by the table ncpXXwl333.
12 Authors:
13         MyungJoo Ham <myungjoo.ham@samsung.com>
15 Description
16 -----------
18 The NTC thermistor is a simple thermistor that requires users to provide the
19 resistance and lookup the corresponding compensation table to get the
20 temperature input.
22 The NTC driver provides lookup tables with a linear approximation function
23 and four circuit models with an option not to use any of the four models.
25 The four circuit models provided are:
27         $: resister, [TH]: the thermistor
29  1. connect = NTC_CONNECTED_POSITIVE, pullup_ohm > 0
31    [pullup_uV]
32        |    |
33       [TH]  $ (pullup_ohm)
34        |    |
35        +----+-----------------------[read_uV]
36        |
37        $ (pulldown_ohm)
38        |
39       --- (ground)
41  2. connect = NTC_CONNECTED_POSITIVE, pullup_ohm = 0 (not-connected)
43    [pullup_uV]
44        |
45       [TH]
46        |
47        +----------------------------[read_uV]
48        |
49        $ (pulldown_ohm)
50        |
51       --- (ground)
53  3. connect = NTC_CONNECTED_GROUND, pulldown_ohm > 0
55    [pullup_uV]
56        |
57        $ (pullup_ohm)
58        |
59        +----+-----------------------[read_uV]
60        |    |
61       [TH]  $ (pulldown_ohm)
62        |    |
63       -------- (ground)
65  4. connect = NTC_CONNECTED_GROUND, pulldown_ohm = 0 (not-connected)
67    [pullup_uV]
68        |
69        $ (pullup_ohm)
70        |
71        +----------------------------[read_uV]
72        |
73       [TH]
74        |
75       --- (ground)
77 When one of the four circuit models is used, read_uV, pullup_uV, pullup_ohm,
78 pulldown_ohm, and connect should be provided. When none of the four models
79 are suitable or the user can get the resistance directly, the user should
80 provide read_ohm and _not_ provide the others.
82 Sysfs Interface
83 ---------------
84 name            the mandatory global attribute, the thermistor name.
86 temp1_type      always 4 (thermistor)
87                 RO
89 temp1_input     measure the temperature and provide the measured value.
90                 (reading this file initiates the reading procedure.)
91                 RO
93 Note that each NTC thermistor has only _one_ thermistor; thus, only temp1 exists.