1 Kernel driver lm87
2 ==================
4 Supported chips:
5   * National Semiconductor LM87
6     Prefix: 'lm87'
7     Addresses scanned: I2C 0x2c - 0x2e
8     Datasheet: http://www.national.com/pf/LM/LM87.html
9   * Analog Devices ADM1024
10     Prefix: 'adm1024'
11     Addresses scanned: I2C 0x2c - 0x2e
12     Datasheet: http://www.analog.com/en/prod/0,2877,ADM1024,00.html
14 Authors:
15         Frodo Looijaard <frodol@dds.nl>,
16         Philip Edelbrock <phil@netroedge.com>,
17         Mark Studebaker <mdsxyz123@yahoo.com>,
18         Stephen Rousset <stephen.rousset@rocketlogix.com>,
19         Dan Eaton <dan.eaton@rocketlogix.com>,
20         Jean Delvare <khali@linux-fr.org>,
21         Original 2.6 port Jeff Oliver
23 Description
24 -----------
26 This driver implements support for the National Semiconductor LM87
27 and the Analog Devices ADM1024.
29 The LM87 implements up to three temperature sensors, up to two fan
30 rotation speed sensors, up to seven voltage sensors, alarms, and some
31 miscellaneous stuff. The ADM1024 is fully compatible.
33 Temperatures are measured in degrees Celsius. Each input has a high
34 and low alarm settings. A high limit produces an alarm when the value
35 goes above it, and an alarm is also produced when the value goes below
36 the low limit.
38 Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
39 triggered if the rotation speed has dropped below a programmable limit. Fan
40 readings can be divided by a programmable divider (1, 2, 4 or 8) to give
41 the readings more range or accuracy. Not all RPM values can accurately be
42 represented, so some rounding is done. With a divider of 2, the lowest
43 representable value is around 2600 RPM.
45 Voltage sensors (also known as IN sensors) report their values in
46 volts. An alarm is triggered if the voltage has crossed a programmable
47 minimum or maximum limit. Note that minimum in this case always means
48 'closest to zero'; this is important for negative voltage measurements.
50 If an alarm triggers, it will remain triggered until the hardware register
51 is read at least once. This means that the cause for the alarm may
52 already have disappeared! Note that in the current implementation, all
53 hardware registers are read whenever any data is read (unless it is less
54 than 1.0 seconds since the last update). This means that you can easily
55 miss once-only alarms.
57 The lm87 driver only updates its values each 1.0 seconds; reading it more
58 often will do no harm, but will return 'old' values.
61 Hardware Configurations
62 -----------------------
64 The LM87 has four pins which can serve one of two possible functions,
65 depending on the hardware configuration.
67 Some functions share pins, so not all functions are available at the same
68 time. Which are depends on the hardware setup. This driver normally
69 assumes that firmware configured the chip correctly. Where this is not
70 the case, platform code must set the I2C client's platform_data to point
71 to a u8 value to be written to the channel register.
73 For reference, here is the list of exclusive functions:
74  - in0+in5 (default) or temp3
75  - fan1 (default) or in6
76  - fan2 (default) or in7
77  - VID lines (default) or IRQ lines (not handled by this driver)