Stay in GETCOORDS if there are more coord prompts.
[geda-gaf/berndj.git] / symbols / documentation / nc.doc
blobcef6cd4a0aa05acb1aa7a766ef8947564b693b39
1 .\" $Id$
2 .\"
3 .\" Example documentation for "No connection"
4 .\" don't take it too seriously ;-)"
5 .\"
6 .so geda.pic
7 .SH
8 No Connection Short Form Data Sheet
9 .\"
10 .SH
11 General Description
12 .LP
13 The 
14 .B "No Connection"
15 component is a mono-pole with unique properties.
16 .\"--------------------------------------------------
17 .SH
18 Applications
19 .IP "\(sq"
21 Digital circuits
22 .IP "\(sq"
24 Analog circuits
25 .IP "\(sq"
27 Mixed signal circuits
28 .IP "\(sq"
30 Consumer products
31 .IP "\(sq"
33 Industry products
34 .\"--------------------------------------------------
35 .SH
36 Features
37 .IP "\(bu"
38 ESD tolerant
39 .IP "\(bu"
40 Latchup free
41 .IP "\(bu"
42 Operates with zero power supplies
43 .IP "\(bu"
44 Simple connection
45 .\"--------------------------------------------------
46 .SH
47 Electrical Characteristics
49 .TS
50 tab(!);
51 | l            | l      | l          | n     n     n    | l    |.
53 \fBParameter\fP!\fBSymbol\fP!\fBConditions\fP!\fBMin\fP!\fBTyp\fP!\fBMax\fP!\fBUnits\fP
55 Supply Voltage ! Vcc    ! Any        !  0  !     ! \(if ! V
57 Supply Current ! Icc    ! Any        !  0  !  0  !  0   ! mA
59 .TE
60 .\"--------------------------------------------------
61 .SH
62 Pin Descriptions
64 .TS
65 tab(!);
66 | n              | l          | l         |.
68 \fBPin\fP        ! \fBName\fP ! \fBFunction\fP  !
70 1                ! NC         ! None whatsoever !
72 .TE
73 .\"--------------------------------------------------
74 .SH
75 Detailed Description
76 .LP
77 The component really does nothing, except making it perfectly clear
78 that when it is connected to pins on other components, they should
79 not, or at least need not, be connected to anything else.
80 .\"--------------------------------------------------
81 .SH
82 Ordering Information
84 .TS
85 tab(!);
86 | l              | l                          | l            | l             |.
88 \fBPart\fP       ! \fBTemp. Range \fP       ! \fBTerminal\fP ! \fBPackage\fP !
90 nc-left          ! -273.16\(deC to +\(if\(deC ! Left         ! None          !
91 nc-right         ! -273.16\(deC to +\(if\(deC ! Right        ! None          !
92 nc-top           ! -273.16\(deC to +\(if\(deC ! Top          ! None          !
93 nc-bottom        ! -273.16\(deC to +\(if\(deC ! Bottom       ! None          !
95 .TE
96 .\"--------------------------------------------------
97 .SH
98 References
99 .LP
101 http://www.geda.seul.org/symlibrary/symbols/misc/