MFC:
[dragonfly.git] / share / man / man4 / nataraid.4
bloba6e2f60b15f498bbc969bd7b65ba0d6725db802e
1 .\" Copyright (c) 2005 Christian Brueffer
2 .\" All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD: src/share/man/man4/ataraid.4,v 1.10 2006/09/18 15:24:18 ru Exp $
26 .\" $DragonFly: src/share/man/man4/nataraid.4,v 1.2 2007/06/24 17:42:58 swildner Exp $
27 .\"
28 .Dd June 24, 2007
29 .Dt NATARAID 4
30 .Os
31 .Sh NAME
32 .Nm nataraid ,
33 .Nm ar
34 .Nd "ATA software RAID support"
35 .Sh SYNOPSIS
36 .Cd "device nata"
37 .Cd "device nataraid"
38 .Sh DESCRIPTION
39 The
40 .Nm
41 driver provides support for so-called software RAID
42 (sometimes referred to as fake RAID or pseudo RAID).
43 .Pp
44 When a controller that supports software RAID is instructed to
45 create a RAID array, its BIOS writes data structures in a specific
46 metadata format to the disks.
47 These data structures are picked up by the
48 .Nm
49 driver, so that
50 .Dx
51 can work with the array.
52 The
53 .Nm
54 driver has to understand the specific metadata format of a
55 controller BIOS in order to support its RAID capabilities.
56 .Pp
57 Read-only support for a metadata format means that
58 .Dx
59 can use the given RAID array for normal read/write operations.
60 Creation and rebuild of such arrays has to be done from the
61 controller BIOS.
62 .Pp
63 Read and write support for a metadata format means that
64 .Dx
65 can use the given RAID array for normal read/write operations.
66 Additionally, the
67 .Xr natacontrol 8
68 utility can be used to create, rebuild, update and fail such
69 RAID arrays.
70 .Pp
71 The
72 .Nm
73 driver can read the following metadata formats:
74 .Pp
75 .Bl -bullet -compact
76 .It
77 Adaptec HostRAID
78 .It
79 Highpoint V2 RocketRAID
80 .It
81 Highpoint V3 RocketRAID
82 .It
83 Intel MatrixRAID
84 .It
85 Integrated Technology Express (ITE)
86 .It
87 JMicron
88 .It
89 LSI Logic V2 MegaRAID
90 .It
91 LSI Logic V3 MegaRAID
92 .It
93 NVIDIA MediaShield
94 .It
95 Promise FastTrak
96 .It
97 Silicon Image Medley
98 .It
99 Silicon Integrated Systems (SiS)
101 VIA Tech V-RAID
103 FreeBSD PseudoRAID
108 driver can write the following metadata formats:
110 .Bl -bullet -compact
112 Highpoint V2 RocketRAID
114 Intel MatrixRAID
116 JMicron
118 Promise FastTrak
120 Silicon Integrated Systems (SiS)
122 VIA Tech V-RAID
124 FreeBSD PseudoRAID
127 It is also possible to use software RAID on controllers
128 that do not have special software RAID capabilities.
130 .Xr natacontrol 8
131 for details.
132 .Sh FILES
133 .Bl -tag -width ".Pa /dev/ar*" -compact
134 .It Pa /dev/ar*
135 ATA RAID device nodes
137 .Sh SEE ALSO
138 .Xr nata 4 ,
139 .Xr natacontrol 8
140 .Sh CAVEATS
141 RAID5 is not supported at this time.
142 Code exists, but it neither uses nor maintains parity information.
143 .Sh AUTHORS
144 .An -nosplit
147 driver was written by
148 .An S\(/oren Schmidt Aq sos@FreeBSD.org .
149 This manual page was written by
150 .An Christian Brueffer Aq brueffer@FreeBSD.org .