4 Copyright (c) 2017-2019 Jiri Slaby
6 This document describes the new macros for annotation of data and code in
7 assembly. In particular, it contains information about ``SYM_FUNC_START``,
8 ``SYM_FUNC_END``, ``SYM_CODE_START``, and similar.
12 Some code like entries, trampolines, or boot code needs to be written in
13 assembly. The same as in C, such code is grouped into functions and
14 accompanied with data. Standard assemblers do not force users into precisely
15 marking these pieces as code, data, or even specifying their length.
16 Nevertheless, assemblers provide developers with such annotations to aid
17 debuggers throughout assembly. On top of that, developers also want to mark
18 some functions as *global* in order to be visible outside of their translation
21 Over time, the Linux kernel has adopted macros from various projects (like
22 ``binutils``) to facilitate such annotations. So for historic reasons,
23 developers have been using ``ENTRY``, ``END``, ``ENDPROC``, and other
24 annotations in assembly. Due to the lack of their documentation, the macros
25 are used in rather wrong contexts at some locations. Clearly, ``ENTRY`` was
26 intended to denote the beginning of global symbols (be it data or code).
27 ``END`` used to mark the end of data or end of special functions with
28 *non-standard* calling convention. In contrast, ``ENDPROC`` should annotate
29 only ends of *standard* functions.
31 When these macros are used correctly, they help assemblers generate a nice
32 object with both sizes and types set correctly. For example, the result of
33 ``arch/x86/lib/putuser.S``::
35 Num: Value Size Type Bind Vis Ndx Name
36 25: 0000000000000000 33 FUNC GLOBAL DEFAULT 1 __put_user_1
37 29: 0000000000000030 37 FUNC GLOBAL DEFAULT 1 __put_user_2
38 32: 0000000000000060 36 FUNC GLOBAL DEFAULT 1 __put_user_4
39 35: 0000000000000090 37 FUNC GLOBAL DEFAULT 1 __put_user_8
41 This is not only important for debugging purposes. When there are properly
42 annotated objects like this, tools can be run on them to generate more useful
43 information. In particular, on properly annotated objects, ``objtool`` can be
44 run to check and fix the object if needed. Currently, ``objtool`` can report
45 missing frame pointer setup/destruction in functions. It can also
46 automatically generate annotations for :doc:`ORC unwinder <x86/orc-unwinder>`
47 for most code. Both of these are especially important to support reliable
48 stack traces which are in turn necessary for :doc:`Kernel live patching
49 <livepatch/livepatch>`.
53 As one might realize, there were only three macros previously. That is indeed
54 insufficient to cover all the combinations of cases:
56 * standard/non-standard function
60 There was a discussion_ and instead of extending the current ``ENTRY/END*``
61 macros, it was decided that brand new macros should be introduced instead::
63 So how about using macro names that actually show the purpose, instead
64 of importing all the crappy, historic, essentially randomly chosen
65 debug symbol macro names from the binutils and older kernels?
67 .. _discussion: https://lkml.kernel.org/r/20170217104757.28588-1-jslaby@suse.cz
72 The new macros are prefixed with the ``SYM_`` prefix and can be divided into
75 1. ``SYM_FUNC_*`` -- to annotate C-like functions. This means functions with
76 standard C calling conventions, i.e. the stack contains a return address at
77 the predefined place and a return from the function can happen in a
78 standard way. When frame pointers are enabled, save/restore of frame
79 pointer shall happen at the start/end of a function, respectively, too.
81 Checking tools like ``objtool`` should ensure such marked functions conform
82 to these rules. The tools can also easily annotate these functions with
83 debugging information (like *ORC data*) automatically.
85 2. ``SYM_CODE_*`` -- special functions called with special stack. Be it
86 interrupt handlers with special stack content, trampolines, or startup
89 Checking tools mostly ignore checking of these functions. But some debug
90 information still can be generated automatically. For correct debug data,
91 this code needs hints like ``UNWIND_HINT_REGS`` provided by developers.
93 3. ``SYM_DATA*`` -- obviously data belonging to ``.data`` sections and not to
94 ``.text``. Data do not contain instructions, so they have to be treated
95 specially by the tools: they should not treat the bytes as instructions,
96 nor assign any debug information to them.
100 This section covers ``SYM_FUNC_*`` and ``SYM_CODE_*`` enumerated above.
102 * ``SYM_FUNC_START`` and ``SYM_FUNC_START_LOCAL`` are supposed to be **the
103 most frequent markings**. They are used for functions with standard calling
104 conventions -- global and local. Like in C, they both align the functions to
105 architecture specific ``__ALIGN`` bytes. There are also ``_NOALIGN`` variants
106 for special cases where developers do not want this implicit alignment.
108 ``SYM_FUNC_START_WEAK`` and ``SYM_FUNC_START_WEAK_NOALIGN`` markings are
109 also offered as an assembler counterpart to the *weak* attribute known from
112 All of these **shall** be coupled with ``SYM_FUNC_END``. First, it marks
113 the sequence of instructions as a function and computes its size to the
114 generated object file. Second, it also eases checking and processing such
115 object files as the tools can trivially find exact function boundaries.
117 So in most cases, developers should write something like in the following
118 example, having some asm instructions in between the macros, of course::
120 SYM_FUNC_START(memset)
124 In fact, this kind of annotation corresponds to the now deprecated ``ENTRY``
125 and ``ENDPROC`` macros.
127 * ``SYM_FUNC_START_ALIAS`` and ``SYM_FUNC_START_LOCAL_ALIAS`` serve for those
128 who decided to have two or more names for one function. The typical use is::
130 SYM_FUNC_START_ALIAS(__memset)
131 SYM_FUNC_START(memset)
134 SYM_FUNC_END_ALIAS(__memset)
136 In this example, one can call ``__memset`` or ``memset`` with the same
137 result, except the debug information for the instructions is generated to
138 the object file only once -- for the non-``ALIAS`` case.
140 * ``SYM_CODE_START`` and ``SYM_CODE_START_LOCAL`` should be used only in
141 special cases -- if you know what you are doing. This is used exclusively
142 for interrupt handlers and similar where the calling convention is not the C
143 one. ``_NOALIGN`` variants exist too. The use is the same as for the ``FUNC``
146 SYM_CODE_START_LOCAL(bad_put_user)
148 SYM_CODE_END(bad_put_user)
150 Again, every ``SYM_CODE_START*`` **shall** be coupled by ``SYM_CODE_END``.
152 To some extent, this category corresponds to deprecated ``ENTRY`` and
153 ``END``. Except ``END`` had several other meanings too.
155 * ``SYM_INNER_LABEL*`` is used to denote a label inside some
156 ``SYM_{CODE,FUNC}_START`` and ``SYM_{CODE,FUNC}_END``. They are very similar
157 to C labels, except they can be made global. An example of use::
159 SYM_CODE_START(ftrace_caller)
160 /* save_mcount_regs fills in first two parameters */
163 SYM_INNER_LABEL(ftrace_caller_op_ptr, SYM_L_GLOBAL)
164 /* Load the ftrace_ops into the 3rd parameter */
167 SYM_INNER_LABEL(ftrace_call, SYM_L_GLOBAL)
171 SYM_CODE_END(ftrace_caller)
175 Similar to instructions, there is a couple of macros to describe data in the
178 * ``SYM_DATA_START`` and ``SYM_DATA_START_LOCAL`` mark the start of some data
179 and shall be used in conjunction with either ``SYM_DATA_END``, or
180 ``SYM_DATA_END_LABEL``. The latter adds also a label to the end, so that
181 people can use ``lstack`` and (local) ``lstack_end`` in the following
184 SYM_DATA_START_LOCAL(lstack)
186 SYM_DATA_END_LABEL(lstack, SYM_L_LOCAL, lstack_end)
188 * ``SYM_DATA`` and ``SYM_DATA_LOCAL`` are variants for simple, mostly one-line
191 SYM_DATA(HEAP, .long rm_heap)
192 SYM_DATA(heap_end, .long rm_stack)
194 In the end, they expand to ``SYM_DATA_START`` with ``SYM_DATA_END``
199 All the above reduce themselves to some invocation of ``SYM_START``,
200 ``SYM_END``, or ``SYM_ENTRY`` at last. Normally, developers should avoid using
203 Further, in the above examples, one could see ``SYM_L_LOCAL``. There are also
204 ``SYM_L_GLOBAL`` and ``SYM_L_WEAK``. All are intended to denote linkage of a
205 symbol marked by them. They are used either in ``_LABEL`` variants of the
206 earlier macros, or in ``SYM_START``.
211 Architecture can also override any of the macros in their own
212 ``asm/linkage.h``, including macros specifying the type of a symbol
213 (``SYM_T_FUNC``, ``SYM_T_OBJECT``, and ``SYM_T_NONE``). As every macro
214 described in this file is surrounded by ``#ifdef`` + ``#endif``, it is enough
215 to define the macros differently in the aforementioned architecture-dependent