1 title: UCS C-Series Rack Server: PSU (voltage)
2 agents: agent_ucs_bladecenter
3 catalog: hw/server/cisco
7 This check provides information about the voltage status of an UCS C-Series Rack Servers racks power supply unit (PSU).
9 This check supports the following C-Series Rack Server models providing XML API 2.0
10 [Cisco UCS Rack-Mount Servers Cisco IMC XML API 2.0]:
12 - Cisco UCS C220 M5 Rack Server
14 - Cisco UCS C240 M5 Rack Server
16 - Cisco UCS C480 M5 Rack Server
18 - Cisco UCS C480 ML M5 Rack Server
20 - Cisco UCS C220 M4 Rack Server
22 - Cisco UCS C240 M4 Rack Server
24 - Cisco UCS C460 M4 Rack Server
26 This check does not support the C-Series Rack Server model "Cisco UCS C125 M5 Rack Server Node"
27 which is used as part of a "Cisco UCS C4200 Series Rack Server Chassis".
31 - {OK} is case the voltage status is one of:
34 - {WARN} in case the voltage status is one of:
35 lower-non-critical, upper-non-critical, not-supported
37 - {CRIT} is case ethe voltage status is one of:
38 lower-critical, lower-non-recoverable, upper-non-recoverable, upper-critical
40 - {UNKNOWN} in case the voltage status is one of:
44 All server racks included in the agent plugin output are found automatically.
47 One item per server rack PSU.