1 Title: ups_test: Fix computation of time since last self test
2 Level: 2
3 Component: checks
4 Compatible: compat
5 Version: 1.2.6b1
6 Date: 1417776132
7 Class: fix
9 Instead of the time since the last self test of the battery, the check used
10 the time the last test has <i>lasted</i>. So this check did not trigger
11 an alarm every - just for the summary state of the last test.