Refactoring: Changed remaining check parameters starting with an 's' to the new rules...
[check_mk.git] / .werks / 7500
blobbe882fae52f2d73a8f6adcc5e405c8b58e3a849e
1 Title: Being more robust against duplicat engineIDs when monitoring SNMPv3 devices
2 Level: 1
3 Component: inline-snmp
4 Compatible: compat
5 Version: 1.2.7i2
6 Date: 1433506248
7 Class: fix
9 The engineID is defined to be a globally unique identifier of a SNMPv3 device, but it happens
10 that users configure the same engineID multiple times for different devices, which made
11 Check_MK only talk to one of them and reporting "No Response from host (Timeout 0/-24)" for
12 the other devices. This has been changed now that Check_MK disregards the misconfiguration
13 and works as usual.