Refactoring: Changed remaining check parameters starting with an 's' to the new rules...
[check_mk.git] / .werks / 2434
blobfbe15b1923467f5629d5d3de3b657a58a9b43bf8
1 Title: NetApp monitoring: Cluster-Mode is now supported, changes in existing 7Mode checks
2 Level: 2
3 Component: checks
4 Class: feature
5 Compatible: incomp
6 State: unknown
7 Version: 1.2.7i4
8 Date: 1444823036
10 This update enables to monitor NetApp Filers running in Cluster-Mode.
11 The new <i>agent_netapp</i> is able to automatically detect whether the filer
12 is running in 7Mode or Cluster-Mode, so you only have to configure the
13 credentials in the datasource rule as usual.
15 Some of the existing 7Mode checks have been adjusted. Overall there are now less summary
16 checks available (e.g. fan, temperature, psu). You need to do a service discovery on each NetApp filer.
18 The following table shows the list of available checks and the currently
19 supported NetApp mode.
21 <table>
22 <tr><th>Check</th><th>Description</th><th>7Mode</th><th>Cluster-Mode</th></tr>
23 <tr> <td>netapp_api_aggr</td> <td>Used space and trend of aggregations</td> <td>X</td> <td>X</td></tr>
24 <tr> <td>netapp_api_volumes</td> <td>Used space an trend of volumes. Able to record detailed performance data for each protocol</td> <td>X</td> <td>X</td></tr>
25 <tr> <td>netapp_api_info</td> <td>Displays NetApp version</td> <td>X</td> <td>X</td></tr>
26 <tr> <td>netapp_api_cpu</td> <td>CPU utilization of nodes</td> <td></td> <td>X</td></tr>
27 <tr> <td>netapp_api_cpu.utilization</td> <td>CPU utilization for 7Mode filer</td> <td>X</td> <td></td></tr>
28 <tr> <td>netapp_api_cluster</td> <td>Cluster status</td> <td>X</td> <td></td></tr>
29 <tr> <td>netapp_api_cpu.nvram_bat</td> <td>NVRAM battery status</td> <td></td> <td>X</td></tr>
30 <tr> <td>netapp_api_disk.summary</td> <td>Disk summary check. Includes total raw capacity and info about broken/spare ratio</td> <td>X</td> <td>X</td></tr>
31 <tr> <td>netapp_api_fcp</td> <td>Fibrechannel interfaces traffic and latency</td> <td></td> <td>X</td></tr>
32 <tr> <td>netapp_api_if</td> <td>Ethernet interfaces</td> <td>X</td> <td>X</td></tr>
33 <tr> <td>netapp_api_protocol</td> <td>Read OPS / Write OPS for each protocol (nfs, nfsv4, cifs, fcp, iscsci)</td> <td>X</td> <td></td></tr>
34 <tr> <td>netapp_api_temp</td> <td>Temperature sensors, grouped by shelf</td> <td>X</td> <td>X</td></tr>
35 <tr> <td>netapp_api_psu</td> <td>Power supplies</td> <td>X</td> <td>X</td></tr>
36 <tr> <td>netapp_api_fan</td> <td>Fan status</td> <td>X</td> <td>X</td></tr>
37 <tr> <td>netapp_api_snapvault</td> <td>Snapvault Lag-time</td> <td>X</td> <td></td></tr>
38 <tr> <td>netapp_api_status</td> <td>Diagnosis status</td> <td>X</td> <td>X</td></tr>
39 <tr> <td>netapp_api_vf_stats.traffic</td> <td>vFiler traffic (Read/Write OPS, Net-Data Send/Recv, Read/Write Bytes)</td> <td>X</td> <td></td></tr>
40 <tr> <td>netapp_api_vf_stats</td> <td>CPU utilization of vFilers</td> <td>X</td> <td></td></tr>
41 <tr> <td>netapp_api_vf_status</td> <td>vFiler status, e.g running</td> <td>X</td> <td></td></tr>
42 <tr> <td>netapp_api_vs_status</td> <td>vServer status, e.g running</td> <td></td> <td>X</td></tr>
43 <tr> <td>netapp_api_vs_traffic</td> <td>vServer Traffic Summary</td> <td></td> <td>X</td></tr>