Properly demangle a global constructor symbol.
[binutils.git] / gas / doc / c-d30v.texi
blob731b3441e0f56433f75e85f33c431839b117dba3
1 @c Copyright (C) 1997 Free Software Foundation, Inc.
2 @c This is part of the GAS manual.
3 @c For copying conditions, see the file as.texinfo.
4 @ifset GENERIC
5 @page
6 @node D30V-Dependent
7 @chapter D30V Dependent Features
8 @end ifset
9 @ifclear GENERIC
10 @node Machine Dependencies
11 @chapter D30V Dependent Features
12 @end ifclear
14 @cindex D30V support
15 @menu
16 * D30V-Opts::                   D30V Options
17 * D30V-Syntax::                 Syntax
18 * D30V-Float::                  Floating Point
19 * D30V-Opcodes::                Opcodes
20 @end menu
22 @node D30V-Opts
23 @section D30V Options
24 @cindex options, D30V
25 @cindex D30V options
26 The Mitsubishi D30V version of @code{@value{AS}} has a few machine
27 dependent options.
29 @table @samp
30 @item -O
31 The D30V can often execute two sub-instructions in parallel. When this option
32 is used, @code{@value{AS}} will attempt to optimize its output by detecting when
33 instructions can be executed in parallel.
35 @item -n
36 When this option is used, @code{@value{AS}} will issue a warning every
37 time it adds a nop instruction.
39 @item -N
40 When this option is used, @code{@value{AS}} will issue a warning if it
41 needs to insert a nop after a 32-bit multiply before a load or 16-bit
42 multiply instruction.
43 @end table
45 @node D30V-Syntax
46 @section Syntax
47 @cindex D30V syntax
48 @cindex syntax, D30V
50 The D30V syntax is based on the syntax in Mitsubishi's D30V architecture manual.
51 The differences are detailed below.
53 @menu
54 * D30V-Size::                 Size Modifiers
55 * D30V-Subs::                 Sub-Instructions
56 * D30V-Chars::                Special Characters
57 * D30V-Guarded::              Guarded Execution
58 * D30V-Regs::                 Register Names
59 * D30V-Addressing::           Addressing Modes
60 @end menu
63 @node D30V-Size
64 @subsection Size Modifiers
65 @cindex D30V size modifiers
66 @cindex size modifiers, D30V
67 The D30V version of @code{@value{AS}} uses the instruction names in the D30V
68 Architecture Manual.  However, the names in the manual are sometimes ambiguous.
69 There are instruction names that can assemble to a short or long form opcode.
70 How does the assembler pick the correct form?  @code{@value{AS}} will always pick the
71 smallest form if it can.  When dealing with a symbol that is not defined yet when a
72 line is being assembled, it will always use the long form.  If you need to force the 
73 assembler to use either the short or long form of the instruction, you can append
74 either @samp{.s} (short) or @samp{.l} (long) to it.  For example, if you are writing 
75 an assembly program and you want to do a branch to a symbol that is defined later
76 in your program, you can write @samp{bra.s foo}. 
77 Objdump and GDB will always append @samp{.s} or @samp{.l} to instructions which
78 have both short and long forms.
80 @node D30V-Subs
81 @subsection Sub-Instructions
82 @cindex D30V sub-instructions
83 @cindex sub-instructions, D30V
84 The D30V assembler takes as input a series of instructions, either one-per-line,
85 or in the special two-per-line format described in the next section.  Some of these
86 instructions will be short-form or sub-instructions.  These sub-instructions can be packed
87 into a single instruction.  The assembler will do this automatically.  It will also detect
88 when it should not pack instructions.  For example, when a label is defined, the next
89 instruction will never be packaged with the previous one.  Whenever a branch and link
90 instruction is called, it will not be packaged with the next instruction so the return
91 address will be valid.  Nops are automatically inserted when necessary.
93 If you do not want the assembler automatically making these decisions, you can control
94 the packaging and execution type (parallel or sequential) with the special execution 
95 symbols described in the next section.  
97 @node D30V-Chars
98 @subsection Special Characters
99 @cindex line comment character, D30V
100 @cindex D30V line comment character
101 @samp{;} and @samp{#} are the line comment characters.
102 @cindex sub-instruction ordering, D30V
103 @cindex D30V sub-instruction ordering
104 Sub-instructions may be executed in order, in reverse-order, or in parallel.
105 Instructions listed in the standard one-per-line format will be executed
106 sequentially unless you use the @samp{-O} option.
108 To specify the executing order, use the following symbols: 
109 @table @samp
110 @item ->
111 Sequential with instruction on the left first.
113 @item <-
114 Sequential with instruction on the right first.
116 @item ||
117 Parallel
118 @end table
120 The D30V syntax allows either one instruction per line, one instruction per line with
121 the execution symbol, or two instructions per line.  For example
122 @table @code
123 @item abs r2,r3 -> abs r4,r5
124 Execute these sequentially.  The instruction on the right is in the right
125 container and is executed second.
127 @item abs r2,r3 <- abs r4,r5
128 Execute these reverse-sequentially.  The instruction on the right is in the right
129 container, and is executed first.
131 @item abs r2,r3 || abs r4,r5
132 Execute these in parallel.
134 @item ldw r2,@@(r3,r4) ||
135 @itemx mulx r6,r8,r9
136 Two-line format. Execute these in parallel.
138 @item mulx a0,r8,r9
139 @itemx stw r2,@@(r3,r4)
140 Two-line format. Execute these sequentially unless @samp{-O} option is
141 used.  If the @samp{-O} option is used, the assembler will determine if
142 the instructions could be done in parallel (the above two instructions
143 can be done in parallel), and if so, emit them as parallel instructions.
144 The assembler will put them in the proper containers.  In the above
145 example, the assembler will put the @samp{stw} instruction in left
146 container and the @samp{mulx} instruction in the right container.
148 @item stw r2,@@(r3,r4) ->
149 @itemx mulx a0,r8,r9
150 Two-line format.  Execute the @samp{stw} instruction followed by the
151 @samp{mulx} instruction sequentially.  The first instruction goes in the
152 left container and the second instruction goes into right container.
153 The assembler will give an error if the machine ordering constraints are
154 violated.
156 @item stw r2,@@(r3,r4) <-
157 @itemx mulx a0,r8,r9
158 Same as previous example, except that the @samp{mulx} instruction is
159 executed before the @samp{stw} instruction.
160 @end table
162 @cindex symbol names, @samp{$} in
163 @cindex @code{$} in symbol names
164 Since @samp{$} has no special meaning, you may use it in symbol names.
166 @node D30V-Guarded
167 @subsection Guarded Execution
168 @cindex D30V Guarded Execution
169 @code{@value{AS}} supports the full range of guarded execution
170 directives for each instruction.  Just append the directive after the
171 instruction proper.  The directives are:
173 @table @samp
174 @item /tx
175 Execute the instruction if flag f0 is true.
176 @item /fx
177 Execute the instruction if flag f0 is false.
178 @item /xt
179 Execute the instruction if flag f1 is true.
180 @item /xf
181 Execute the instruction if flag f1 is false.
182 @item /tt
183 Execute the instruction if both flags f0 and f1 are true.
184 @item /tf
185 Execute the instruction if flag f0 is true and flag f1 is false.
186 @end table
188 @node D30V-Regs
189 @subsection Register Names
190 @cindex D30V registers
191 @cindex registers, D30V
192 You can use the predefined symbols @samp{r0} through @samp{r63} to refer
193 to the D30V registers.  You can also use @samp{sp} as an alias for
194 @samp{r63} and @samp{link} as an alias for @samp{r62}.  The accumulators
195 are @samp{a0} and @samp{a1}.
197 The D30V also has predefined symbols for these control registers and status bits:
198 @table @code
199 @item psw
200 Processor Status Word
201 @item bpsw
202 Backup Processor Status Word
203 @item pc
204 Program Counter
205 @item bpc
206 Backup Program Counter
207 @item rpt_c
208 Repeat Count
209 @item rpt_s
210 Repeat Start address
211 @item rpt_e
212 Repeat End address
213 @item mod_s
214 Modulo Start address
215 @item mod_e
216 Modulo End address
217 @item iba
218 Instruction Break Address
219 @item f0
220 Flag 0
221 @item f1
222 Flag 1
223 @item f2
224 Flag 2
225 @item f3
226 Flag 3
227 @item f4
228 Flag 4
229 @item f5
230 Flag 5
231 @item f6
232 Flag 6
233 @item f7
234 Flag 7
235 @item s
236 Same as flag 4 (saturation flag)
237 @item v
238 Same as flag 5 (overflow flag)
239 @item va
240 Same as flag 6 (sticky overflow flag)
241 @item c
242 Same as flag 7 (carry/borrow flag)
243 @item b
244 Same as flag 7 (carry/borrow flag)
245 @end table
246         
247 @node D30V-Addressing
248 @subsection Addressing Modes
249 @cindex addressing modes, D30V
250 @cindex D30V addressing modes
251 @code{@value{AS}} understands the following addressing modes for the D30V.
252 @code{R@var{n}} in the following refers to any of the numbered
253 registers, but @emph{not} the control registers.
254 @table @code
255 @item R@var{n}
256 Register direct
257 @item @@R@var{n}
258 Register indirect
259 @item @@R@var{n}+
260 Register indirect with post-increment
261 @item @@R@var{n}-
262 Register indirect with post-decrement
263 @item @@-SP
264 Register indirect with pre-decrement
265 @item @@(@var{disp}, R@var{n})
266 Register indirect with displacement
267 @item @var{addr}
268 PC relative address (for branch or rep). 
269 @item #@var{imm}
270 Immediate data (the @samp{#} is optional and ignored)
271 @end table
273 @node D30V-Float
274 @section Floating Point
275 @cindex floating point, D30V
276 @cindex D30V floating point
277 The D30V has no hardware floating point, but the @code{.float} and @code{.double}
278 directives generates @sc{ieee} floating-point numbers for compatibility
279 with other development tools. 
281 @node D30V-Opcodes
282 @section Opcodes
283 @cindex D30V opcode summary
284 @cindex opcode summary, D30V
285 @cindex mnemonics, D30V
286 @cindex instruction summary, D30V
287 For detailed information on the D30V machine instruction set, see
288 @cite{D30V Architecture: A VLIW Microprocessor for Multimedia Applications} 
289 (Mitsubishi Electric Corp.).
290 @code{@value{AS}} implements all the standard D30V opcodes.  The only changes are those
291 described in the section on size modifiers