3 http://www.grimes.demon.co.uk/DCOM/DCOMSpec.htm
7 The OXID Resolver can turn a OXID (Object Exporter ID) into a
8 RPC binding string that can be used to contact an object
13 import
"misc.idl", "orpc.idl";
16 uuid("99fcfec4-5260-101b-bbcb-00aa0021347a"),
17 helpstring("Object Exporter ID Resolver"),
18 endpoint("ncacn_np:[\\pipe\\epmapper]", "ncacn_ip_tcp:[135]", "ncalrpc:"),
19 pointer_default(unique)
21 interface IOXIDResolver
28 /* Method to get the protocol sequences, string bindings */
29 /* and machine id for an object server given its OXID. */
31 [idempotent
] WERROR ResolveOxid
(
33 [in] uint16 cRequestedProtseqs
,
34 [in, size_is(cRequestedProtseqs
)] uint16 arRequestedProtseqs
[],
35 [out] DUALSTRINGARRAY
**ppdsaOxidBindings
,
36 [out,ref] IPID
*pipidRemUnknown
,
37 [out,ref] uint32
*pAuthnHint
40 /* Simple ping is used to ping a Set. Client machines use this */
41 /* to inform the object exporter that it is still using the */
42 /* members of the set. */
43 /* Returns S_TRUE if the SetId is known by the object exporter, */
45 [idempotent
] WERROR SimplePing
(
46 [in] SETID
*SetId
/* Must not be zero */
49 /* Complex ping is used to create sets of OIDs to ping. The */
50 /* whole set can subsequently be pinged using SimplePing, */
51 /* thus reducing network traffic. */
52 [idempotent
] WERROR ComplexPing
(
53 [in,out,ref] SETID
*SetId
, /* In of 0 on first call for new set. */
54 [in] uint16 SequenceNum
,
55 [in] uint16 cAddToSet
,
56 [in] uint16 cDelFromSet
,
57 /* add these OIDs to the set */
58 [in, size_is(cAddToSet
)] OID AddToSet
[],
59 /*remove these OIDs from the set */
60 [in, size_is(cDelFromSet
)] OID DelFromSet
[],
61 [out,ref] uint16
*PingBackoffFactor
/* 2^factor = multipler */
64 /* In some cases the client maybe unsure that a particular */
65 /* binding will reach the server. (For example, when the oxid */
66 /* bindings have more than one TCP/IP binding) This call */
67 /* can be used to validate the binding */
68 /* from the client. */
69 [idempotent
] WERROR ServerAlive
();
71 /* Method to get the protocol sequences, string bindings, */
72 /* RemoteUnknown IPID and COM version for an object server */
73 /* given its OXID. Supported by DCOM */
74 /* version 5.2 and above. Looks like that means
75 * Windows 2003/XP and above */
76 [idempotent
] WERROR ResolveOxid2
(
78 [in] uint16 cRequestedProtseqs
,
79 [in, size_is(cRequestedProtseqs
)] uint16 arRequestedProtseqs
[],
80 [out] DUALSTRINGARRAY
**pdsaOxidBindings
,
81 [out,ref] IPID
*ipidRemUnknown
,
82 [out,ref] uint32
*AuthnHint
,
83 [out,ref] COMVERSION
*ComVersion
91 [idempotent
] WERROR ServerAlive2
(
92 [out,ref] COMINFO
*info
,
93 [out,ref] DUALSTRINGARRAY
**dualstring
,
94 [out,ref] uint8
*pReserved