deadbat-soft-start.patch

This patch sets the maximum USB fast charge current to 100mA instead of
1A. This is an attempt to reduce the inrush current of the battery and
circuits directly attached to the battery.

Without change, the comparably large capacitors on subsystems that are
directly supplied from the battery would cause a sharp drop of VB_SYS,
which prompted the PMU to reset.

Signed-off-by: Werner Almesberger <werner@openmoko.org>
board/neo1973/gta02/gta02.c
board/neo1973/gta02/pcf50633.c