block/nbd: on shutdown terminate connection attempt
On shutdown nbd driver may be in a connecting state. We should shutdown
it as well, otherwise we may hang in
nbd_teardown_connection, waiting for conneciton_co to finish in
BDRV_POLL_WHILE(bs, s->connection_co) loop if remote server is down.
How to reproduce the dead lock:
1. Create nbd-fault-injector.conf with the following contents:
[inject-error "mega1"]
event=data
io=readwrite
when=before
2. In one terminal run nbd-fault-injector in a loop, like this:
n=1; while true; do
echo $n; ((n++));
./nbd-fault-injector.py 127.0.0.1:10000 nbd-fault-injector.conf;
done
3. In another terminal run qemu-io in a loop, like this:
n=1; while true; do
echo $n; ((n++));
./qemu-io -c 'read 0 512' nbd://127.0.0.1:10000;
done
After some time, qemu-io will hang. Note, that this hang may be
triggered by another bug, so the whole case is fixed only together with
commit "block/nbd: allow drain during reconnect attempt".
Signed-off-by: Vladimir Sementsov-Ogievskiy <vsementsov@virtuozzo.com>
Reviewed-by: Eric Blake <eblake@redhat.com>
Message-Id: <
20200727184751.15704-4-vsementsov@virtuozzo.com>
Signed-off-by: Eric Blake <eblake@redhat.com>