Gigabeat S: Extend the upper temperature range for battery charging to 50C: OK and...
commit1393187c91fb2a2f67c21e5a7835ceb0a846dbbb
authorjethead71 <jethead71@a1c6a512-1295-4272-9138-f99709370657>
Wed, 7 Apr 2010 06:26:18 +0000 (7 06:26 +0000)
committerjethead71 <jethead71@a1c6a512-1295-4272-9138-f99709370657>
Wed, 7 Apr 2010 06:26:18 +0000 (7 06:26 +0000)
treee84e6d3d869580dfb1ccc9abc66bf05ad9cbbe42
parent7040d1463e46b1ef043cd258b5f6db5e6cd9f9c4
Gigabeat S: Extend the upper temperature range for battery charging to 50C: OK and 45C: Resume. Currently extended disk activity can cause it to detect overtemp which doesn't quite seem correct. Add macros for the range so that they may be target-specific.

git-svn-id: svn://svn.rockbox.org/rockbox/trunk@25508 a1c6a512-1295-4272-9138-f99709370657
firmware/target/arm/imx31/gigabeat-s/powermgmt-imx31.c