W1: w1_therm.c ds18b20 decode freezing temperatures correctly
Correct the decoding of negative C temperatures. The code did a binary OR
of two bytes to make a 16 bit value, but assignd it to an integer. This
caused the value to not be sign extended and to loose that it was a
negative number in the assignment.
Before the patch (in my freezer),
w1_slave
ed fe 4b 46 7f ff 03 10 e4 : crc=e4 YES
ed fe 4b 46 7f ff 03 10 e4 t=4078
With the patch,
e3 fe 4b 46 7f ff 0d 10 81 : crc=81 YES
e3 fe 4b 46 7f ff 0d 10 81 t=-17
Signed-off-by: David Fries <david@fries.net>
Acked-by: Evgeniy Polyakov <johnpol@2ka.mipt.ru>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>