From cf312e077662ec3a07529551ab6e885828ccfb1d Mon Sep 17 00:00:00 2001 From: Jean Delvare Date: Mon, 16 Nov 2009 12:45:39 +0100 Subject: [PATCH] hwmon: (adt7475) Fix temperature fault flags The logic of temperature fault flags is wrong, it shows faults when there are none and vice versa. Fix it. I can't believe this has been broken since the driver was added, 8 months ago, basically breaking temp1 and temp3, and nobody ever complained. Signed-off-by: Jean Delvare Acked-by: Hans de Goede Cc: Jordan Crouse --- drivers/hwmon/adt7475.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/drivers/hwmon/adt7475.c b/drivers/hwmon/adt7475.c index d39877a7da6..d15819b4fe5 100644 --- a/drivers/hwmon/adt7475.c +++ b/drivers/hwmon/adt7475.c @@ -350,8 +350,7 @@ static ssize_t show_temp(struct device *dev, struct device_attribute *attr, case FAULT: /* Note - only for remote1 and remote2 */ - out = data->alarms & (sattr->index ? 0x8000 : 0x4000); - out = out ? 0 : 1; + out = !!(data->alarms & (sattr->index ? 0x8000 : 0x4000)); break; default: -- 2.11.4.GIT