watchdog: sp805: Don't write 0 to the load value register.
commitda3e515024ba32aaf0d524518ce39a8fb77332cd
authorNick Bowler <nbowler@elliptictech.com>
Fri, 15 Jul 2011 15:04:01 +0000 (15 11:04 -0400)
committerWim Van Sebroeck <wim@iguana.be>
Tue, 26 Jul 2011 21:19:43 +0000 (26 21:19 +0000)
tree89d186e442b76d75ae76ed14b321f5f1adaa012a
parentf5a427eedeead2be82561497a12788bd1f0c07d3
watchdog: sp805: Don't write 0 to the load value register.

At least on the Versatile Express' V2M, calling wdt_disable followed by
wdt_enable, for instance by running the following sequence:

  echo V > /dev/watchdog; echo V > /dev/watchdog

results in an immediate reset.  The wdt_disable function writes 0 to the
load register; while the watchdog interrupts are disabled at this point,
this special value is defined to trigger an interrupt immediately.  It
appears that in this instance, the reset happens when the interrupts
are subsequently enabled by wdt_enable.

Putting in a short delay after writing a new load value in wdt_enable
solves the issue, but it seems cleaner to simply never write 0 to the
load register at all: according to the hardware docs, writing 0 to the
control register suffices to stop the counter, and the write of 0 to
the load register is questionable anyway since this register resets to
0xffffffff.

Signed-off-by: Nick Bowler <nbowler@elliptictech.com>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
drivers/watchdog/sp805_wdt.c