i2c-algo-pca: Let PCA9564 recover from unacked data byte (state 0x30)
commit2196d1cf4afab93fb64c2e5b417096e49b661612
authorEnrik Berkhan <Enrik.Berkhan@ge.com>
Tue, 5 May 2009 06:39:25 +0000 (5 08:39 +0200)
committerJean Delvare <khali@linux-fr.org>
Tue, 5 May 2009 06:39:25 +0000 (5 08:39 +0200)
treeb9534b056eeb3a2e43620ef8ea52dd519ba50ba6
parent0cdba07bb23cdd3e0d64357ec3d983e6b75e541f
i2c-algo-pca: Let PCA9564 recover from unacked data byte (state 0x30)

Currently, the i2c-algo-pca driver does nothing if the chip enters state
0x30 (Data byte in I2CDAT has been transmitted; NOT ACK has been
received).  Thus, the i2c bus connected to the controller gets stuck
afterwards.

I have seen this kind of error on a custom board in certain load
situations most probably caused by interference or noise.

A possible reaction is to let the controller generate a STOP condition.
This is documented in the PCA9564 data sheet (2006-09-01) and the same
is done for other NACK states as well.

Further, state 0x38 isn't handled completely, either. Try to do another
START in this case like the data sheet says. As this couldn't be tested,
I've added a comment to try to reset the chip if the START doesn't help
as suggested by Wolfram Sang.

Signed-off-by: Enrik Berkhan <Enrik.Berkhan@ge.com>
Reviewed-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
drivers/i2c/algos/i2c-algo-pca.c