Corrected value of electric conversion factor f in the manual
commit36035fb031565bd2e938e6d7db304f7a7e2a9046
authorCarsten Kutzner <ckutzne@gwdg.de>
Mon, 4 Apr 2016 11:39:15 +0000 (4 13:39 +0200)
committerMark Abraham <mark.j.abraham@gmail.com>
Thu, 14 Apr 2016 08:42:53 +0000 (14 10:42 +0200)
tree80db210c2689e5ccc17848b5ec65ae8ff98d7484
parent3ba329a9f728a3e4477a91a777ac2de3faad8544
Corrected value of electric conversion factor f in the manual

- As suggested by Christopher Neale
- Made a new latex command for the value so that it can appear
  consistently throughout all uses in the .tex manual
- changed the value to f = 138.935 458(9), which is value and
  standard deviation calculated from NIST 2010 CODATA, as also
  used by GROMACS in units.h (full value calculated from
  numbers in units.h is f = 138.935 457 839 ... )
- If I calculated correctly, the pre-June-2015 value of the std-dev
  was correct, just the last two digits of the value itself
  were swapped in some places 58(9) <-> 85(9)
- I believe commit 1ee3b15530a5 accidentally overwrote the std-dev
  with digits from the value itself

Change-Id: I293768b657a81af0a4dc0865db8c4a1b0eebd4ad
docs/manual/defunits.tex
docs/manual/forcefield.tex
docs/manual/macros.tex