1 title: Adva FSP 3000 Optical Transport: Optical Interface Status
2 catalog: hw/network/adva
7 This checks monitors the state and laser parameters of interfaces of the
8 ADVA FSP 3000 scalable optical transport solution.
10 State information is collected from the SNMP IF-MIB parameters {ifAdminStatus} and
11 {ifOperStatus}. Laser information is collected from the FspR7-MIB parameters
12 {currentPmSnapshotOutputPower} and {currentPmSnapshotInputPower}.
14 Lower and upper critical limits can be configured for the input (received)
15 and output (transmit) power of the laser. Per default, not limits are imposed,
16 since meaningful values depend on the type of interface.
18 A {WARN} state is triggered if no laser power information can be found.
19 Service interfaces (item name beginning with "S") do not have laser power
20 information, so that non-existent laser power information is ignored for these
24 There are three allowed ways to specify an interface: {1}: the last component
25 of the SNMP OID number (as string), the {ifDescr} of the port or the {ifAlias}
26 of the port. If you are using the alias, you have to make sure that it is
27 unique by configuring useful aliases in the switch. Check_MK does not check
29 The default is to use the {ifDescr}.
32 The inventory creates one service for each interface that fulfills
33 configurable conditions. Per default these are interfaces which currently
34 are {up} and are of type {1} (other), {6} (ethernetCsmacd), and {56}